Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Similar documents
CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

OSCILLOSCOPE AND DIGITAL MULTIMETER

The Cathode Ray Tube

Using an oscilloscope - The Hameg 203-6

CATHODE-RAY OSCILLOSCOPE (CRO)

CHAPTER 4 OSCILLOSCOPES

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

CATHODE RAY OSCILLOSCOPE (CRO)

Experiment 9A: Magnetism/The Oscilloscope

University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

MP212 Principles of Audio Technology II

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

4.9 BEAM BLANKING AND PULSING OPTIONS

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania

Cathode Ray Oscilloscope

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Elements of a Television System

THE OPERATION OF A CATHODE RAY TUBE

THE OPERATION OF A CATHODE RAY TUBE

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Agilent DSO5014A Oscilloscope Tutorial

Experiment # 4 Counters and Logic Analyzer

ELECTRICAL ENGINEERING DEPARTMENT California Polytechnic State University

Experiment 9 Analog/Digital Conversion

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

THE CATHODE -RAY OSCILLOSCOPE


BME 3512 Biomedical Laboratory Equipment List

Beginners How to Test DSO138mini

Activity P32: Variation of Light Intensity (Light Sensor)

Physics 123 Hints and Tips

BTV Tuesday 21 November 2006

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Presented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali. Supervised by: Dr.Mohamed Abd El Ghany

imso-104 Manual Revised August 5, 2011

Computer Graphics Hardware

LeCroy Digital Oscilloscopes

INSTRUCTION MANUAL Model 2522C. 20 MHz DIGITAL STORAGE/ANALOG OSCILLOSCOPE

Advanced Test Equipment Rentals ATEC (2832)

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Agilent Technologies 54522A

Time Varying Signals Part A Chemistry 838

4. ANALOG TV SIGNALS MEASUREMENT

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

3B SCIENTIFIC PHYSICS

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

Errata. Title & Document Type: Manual Part Number: Revision Date: HP References in this Manual

WVR500 Waveform/Vector Monitor

imso-104 Manual Revised July 19, 2012

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

OS Series Handheld Digital Storage. Oscilloscope & Multimeter. User Manual

PicoScope 6407 Digitizer

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70

Measuring with digital storage oscilloscopes

Digital Storage Oscilloscopes 2550 Series

An Efficient SOC approach to Design CRT controller on CPLD s

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Machinery Diagnostic Plots Part 2 ORBIT Back-to-Basics: What does the data really tell us?

Choosing an Oscilloscope

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Getting Started with the LabVIEW Sound and Vibration Toolkit

Analog Oscilloscope Operation Manual

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

MAIN PCA TEST PROCEDURE DOCUMENT NUMBER:

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

Spectrum Analyser Basics

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

These are used for producing a narrow and sharply focus beam of electrons.

VGA Port. Chapter 5. Pin 5 Pin 10. Pin 1. Pin 6. Pin 11. Pin 15. DB15 VGA Connector (front view) DB15 Connector. Red (R12) Green (T12) Blue (R11)

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us?

Expect to Make Waves.

MODULAR DIGITAL ELECTRONICS TRAINING SYSTEM

BER MEASUREMENT IN THE NOISY CHANNEL

T ips in measuring and reducing monitor jitter

. The vertical pull-in range is approximately 10 Hz at fv = 60 Hz.

What is sync? Why is sync important? How can sync signals be compromised within an A/V system?... 3

PicoScope 6407 Digitizer

Teltron Delection Tube D

ScopeMeter 190 Series Specifications

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

PC Scopes PCS500 PCS100 / K8031. CHECK THE Pc-Lab2000 TM GETTING STARTED GUIDE FOR SOFTWARE INSTALLATION

OWON HDS1022M Handheld Digital Storage Oscilloscope & Multimeter User s Manual

Introduction to the oscilloscope and digital data acquisition

Pole Zero Correction using OBSPY and PSN Data

MODIFYING A SMALL 12V OPEN FRAME INDUSTRIAL VIDEO MONITOR TO BECOME A 525/625 & 405 LINE MULTI - STANDARD MAINS POWERED UNIT. H. Holden. (Dec.

Transcription:

2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency and phase on a variety of displayed waveforms Introduction The oscilloscope is the basic instrument for the study of all types of waveforms. It is capable of generating a graph of an input signal versus time (Voltage-time mode), or a second variable (X-Y mode). It can be employed to measure such quantities as peak voltage, frequency or period, phase difference, pulse width, delay time, rise time and fall time. Essentially, an oscilloscope consists of a cathode-ray tube (CRT), and its associated control and input circuitry (a time-base generator, vertical and horizontal amplifiers) as shown in Fig.1. In a conventional CRT tube, there are an electron gun, deflection plates and the phosphorescent screen. Electron gun Vertical Deflection plate Horizontal Deflection plate Phosphorescent Screen Electron beam Y input Vertical amplifier Time base circuit X-Y mode switch Horizontal amplifier X input Fig. 1 Simple oscilloscope construction. Principle of operation The electron beam generated from an electron gun will be accelerated toward a phosphorous screen by a potential difference between the electron gun and the screen. As 1

the beam emerges from the gun, it passes through a set of parallel plates (the vertical deflection plates) oriented horizontally. The voltage to be displayed is amplified by a vertical amplifier, and applied across these plates producing an electric field which deflects the path of the electron vertically. The polarity of the signal of interest determines whether the deflections will be up or down and the magnitude of the signal determines the amount of vertical displacement of the electrons. Fig. 2 shows the deflection of an electron in a uniform electric field. Deflecting plate electron - - - - - - - - + + + + + + + + Deflecting plate Fig. 2 Deflection of an electron in a uniform electric field. After the beam has passed through the vertical deflection Plates, it passed through a second set of similar plates that are oriented vertically. A potential difference applied to these plates produce an electric field which deflects left or right. Under normal configuration (one common exception is XY mode to be discussed later), these horizontal deflection plates are connected to a time-base circuitry. This circuit can control how fast the electron beam sweeps from the left to right (use Sweep Knob). Adjusting the sweep speed, the resulting trace on the screen can be spread out or compressed. If the two deflection voltages were held constant, the electron beam would strike a fixed point on the phosphorescent film and a stationary point would be visible on the screen. However, most voltages of interested are time-varying and so the voltage applied to the Horizontal deflection plates is varied with time in such a way that the spot moves from left to right on the screen as time passes. Since the phosphorescent material has the property of emitting light for several milliseconds after the electrons have passed, the total effect is for the electrons to leave behind a visible trail a time-varying signal. The horizontal deflection voltage (of sweep voltage ) is also varied in such a way that when the beam reaches the right-hand edge of the screen, it starts over at the left-right side. If the signal to be displayed varies periodically in time, it is possible to synchronize the sweep voltage with the signal so that the curve appears motionless on the screen. This is done with the Trigger Level control which sets the oscilloscope to begin a trace when the voltage it measures reaches a certain value. If a trace that is running across the screen can usually be stabilized by adjusting the trigger level (as long as the waveform is periodic!). Waveform Display When an alternating voltage is applied to the vertical deflecting plates and no input is applied to the horizontal plates, the spot on the tube face moves up and down continuously. If a constantly increasing voltage is also applied to the horizontal deflecting plates, then as well 2

as moving vertically, the spot on the tube face moves horizontally. Consider fig. 3, in which sine wave is applied to the vertical deflecting plates and a sawtooth (or repetitive ramp) is applied to the horizontal plates. If the wave forms are perfectly synchronized (the trigger level has been set properly)., then at time t = 0, the vertical deflection voltage is zero and the horizontal deflecting voltage is -2 V. Therefore, assuming a deflecting sensitivity of 2 cm/v, the vertical deflection is zero and the horizontal deflection is 4 cm left from the center of the screen [point 1]. When t = 0.5 ms, the horizontal deflecting voltage has become -1.5 V; therefore, the horizontal deflection is 3 cm left from the screen center. The vertical deflecting voltage has now become +1.4 V, and this causes a vertical deflection +2.8 cm above the center of the screen. The spot is now 2.8 cm up and 3 cm left from the screen center, point 2 on Fig. 3. Fig. 3 The synchronization of a sine wave with a sawtooth wave resulting in a graphical display on the screen. 3

The following table gives deflection voltages and deflection at various is instants for the waveform in Fig. 3. t (ms) 1 1.5 2 2.5 3 3.5 4 Vertical voltage (V) +2 +1.4 0-1.4-2 -1.4 0 Vertical deflection (cm) +4 +2.8 0-2.8-4 -2.8 0 Horizontal voltage (V) -1-0.5 0 +0.5 +1 +1.5 +2 Horizontal deflection (cm) -2-1 0 +1 +2 +3 +4 Point 3 4 5 6 7 8 9 At point 9 the horizontal deflecting voltage rapidly goes to -2V again, so the beam returns to the left side of the screen. From here it is ready to repeat the waveform trace. It is seen that with a sawtooth applied to the horizontal deflecting plates, any waveform applied to the vertical plates will be displayed on the screen of the CRT. X-Y Mode Beside of showing a time-varying signal, the oscilloscope also lets you display an input signal rather than the time base on the horizontal axis. This setup is called XY mode because both the X and Y axis are tracing input voltage. As a note of interest, the waveform resulting from XY arrangement of two periodic signals of different periods in called Lissajous pattern, from the shape of Lissajous pattern, we can determine the information about the relative phases of the signals, as well as frequency ratio. 4

Common Oscilloscope Controls. Most oscilloscope comes with two input channels (Channel 1 and 2 or Channel A and B), therefore, two waveforms can display simultaneously on the screen. In this section, we will introduce the most common controls in an oscilloscope. VOLTS/DIV selector switch: (separate controls available for Channel 1 and 2) VERTICAL POSITION control: (separate controls available for Channel 1 and 2) INPUT SELECTOR switch: (AC, DC, GND) (separate controls available for Channel 1 and 2) HORIZONTAL TIME/DIV selector switch: (apply to both Channel 1 and 2) HORIZONTAL POSITION control: (apply to both Channel 1 and 2) TRIGGER LEVEL control: TRIGGER SOURCE selector switch: X-Y MODE selector switch Set the sensitivity of the display to input voltages, adjusting this control makes the displayed waveform to compress and expand in the vertical axis. Use to move each waveform vertically up or down the screen to set it in the best position for viewing Set at DC where all ac and dc components will be both displayed on the screen. Set at AC where a coupling capacitor passes the ac quantity and blocks the dc component. Set at GND to disconnect the input signal and grounds the input terminal. Adjust the rate at which a waveform is draw across the screen Use to move all waveforms horizontal left or right to set them in the best position for viewing Adjust the triggering point of the input wave Use to select the source of the triggering, normally select INT (internal trigger source), which means the time base is triggered from one of the input waveforms. Use to change between V-T and X-Y mode 5

Positions of Common Controls in CRO Used in the experiments Cursor control Trigger setting Time/div control Power on/off Controls for CH1 and CH2 Basic Measurement Procedures 1) Ground the input terminal or oscilloscope probe, set the position of each waveform to obtain the best viewing. 2) Connect the oscilloscope probe to the measuring point. Special care must be taken for the ground of the probe and the reference point of the circuit- under-test) 3) if the waveform is running across the screen, adjust TRIGGER SOURCE selector switch and/or TRIGGER LEVEL controls to stabilize the waveform. 4) Adjust VOLTS/DIV selector switch and/or HORIZONTAL TIME/DIV selector to obtain the proper view. Note: the sequence of the above guidelines can be changed or modify properly to obtain the best results. Consult the scope manual for more details or fine adjustments. 6

Experimental Instructions: Exp1 Waveform Monitoring & Measurement of Amplitude, Frequency and Period of an Alternative Signal 1) Set the INPUT SELECTOR of CH1 to the AC position. 2) Connect the function generator to the input terminal of CH1, set the function generator to give a sinusoidal wave. 3) Adjust the Oscilloscope control until the screen shows the best viewing of the sine wave with two or three periods. Exp2 Measurement of Amplitude, Frequency and Period of a Signal with both DC and AC Components 1) Set the INPUT SELECTOR of CH1 to the DC position. 2) Connect the function generator to the input terminal of CH1, set the function generator to give a sinusoidal wave and also set the DC offset to an appropriate value (the dc value should not be so different with the amplitude of the sine wave) 3) Adjust the Oscilloscope control until the screen shows the best viewing of the sine wave with two or three periods Exp 3 Measurement of Frequency Ratio (Lissajous Figures) 1) Set CRO to the X-Y Mode (normally X for CH1 and Y for CH2) 2) Applied the output from the step-down transformer to the X-input of CRO and the output from the function generator to the Y-input of CRO. The output from the transformer is about 6 V rms with the frequency of 50 Hz. Make sure that the function generator has been set give a sinusoidal wave and DC offset has been set to zero. 3) Set the frequency of the function to 50 Hz (read from the function generator) 4) Adjust the CRO control to obtain a clear figure on the screen. If the setting is proper, you will see an elliptic or circular or line pattern on the screen. (If no, repeat the previous process again) 5) Change the frequency of the function generator to 25, 50, 75 and 100 Hz. Record the graph on the screen for each case. 6) Verify that the frequency ratios obtained from the experiments are consistent with the theoretical values Exp 4 Measurement of Phase Difference (Lissajous Figures VS Voltage-Time) 1) Connect the function generator to the phase shift circuit as shown in Fig. 4. Set frequency to 1000 Hz, amplitude to 2-4 V peak and the output waveform to sinusoidal wave. 2) Use CRO to record the amplitude of the input voltage, the voltage drop across R and C respectively. (These values will be used to verify the experimental results) 7

3) Use the following table to connect the CRO probes to the circuit. 4) Record the displayed waveforms on the screen in both V-T and X-Y mode. In V- T mode, set the CRO to display CH 1 and 2 simultaneously. C Function Generator Sine wave 1 khz R C B Fig.4 Circuit used in the experiment Table 1: Probe connections Case CH 1 CH 2 CRO Ground I A A C II A B C III A C B IV Same as case III, Use the Invert switch for the CH 2 A The Lissajous figures can be used to calculate the phase difference of two sinusoidal with the same frequency as shown in Fig. 5. a b Phase difference = arcsin (a/b) Fig. 5 Calculation of phase difference using Lissajous figure 8

Student Name: ID: Date: Group: Instructor signature: Experimental Report Cathode-Ray Oscilloscope (CRO) Exp1 Waveform Monitoring & Measurement of Amplitude, Frequency and Period of an Alternative Signal CH1: VOLT/DIV switch = TIME/DIV switch = /div The peak-to-peak amplitude = V peak-peak The peak amplitude = V peak The root-mean-square amplitude = V rms (Calculated value) The root-mean-square amplitude = V rms (Read from a multi-meter) Period of the Displayed signal = Sec Frequency of the Displayed signal = Hz (Calculated value) Frequency read from function generator = Hz Frequency read from multi-meter = Hz Discussion 9

Exp2 Measurement of Amplitude, Frequency and Period of a Signal with both DC and AC Components INPUT SELECTOR at DC position CH1: VOLT/DIV switch = TIME/DIV switch = /div INPUT SELECTOR at AC position CH1: VOLT/DIV switch = TIME/DIV switch = /div The peak amplitude of the AC component = V peak The rms value of the AC component = V rms (Calculated value) The rms value read from a multi-meter = V rms The value of the DC component = V The DC value read from a multi-meter = V Discussion 10

Exp 3 Measurement of Frequency Ratio (Lissajous Figures) Case I: frequency of the function generator = 25 Hz Case III: frequency of the function generator = 75 Hz Case II: frequency of the function generator = 50 Hz Case IV: frequency of the function generator = 100 Hz CH1: VOLT/DIV switch = CH2: VOLT/DIV switch = Discussion 11

Exp 4 Measurement of Phase Difference (Lissajous Figures VS Voltage-Time) Case I: X-Y Mode Case I: V-T Mode Case II: X-Y Mode Case II: V-T Mode Case III: X-Y Mode Case III: V-T Mode 12

Case IV: X-Y Mode Case IV: V-T Mode X-Y Mode V-T Mode CH1: VOLT/DIV switch = CH1: VOLT/DIV switch = CH2: VOLT/DIV switch = CH2: VOLT/DIV switch = TIME/DIV switch = /div Discussion 13

Conclusions 14