Pulse Biomedical QRS-Card Tango M2 Interface Notes

Similar documents
Philips StressVue Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Honeywell HomMed Wireless Scale Quick Reference Guide

IMPORTANT! This instruction guide explains how to install your CCTV system.

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Modbus for SKF IMx and Analyst

June/July 2016 Med Tips

RADIO FREQUENCY SYSTEMS

GWL/ Power Group Technology Solutions Stay Powered for the Future

R Series Quick Reference Guide

QUICK START GUIDE QT ANALOG HD CAMERA & DVR BUNDLE ENGLISH

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Amino. Digital Television. Sun City & Hilton Head Island

Camera Setup Instructions

Any feature not specifically noted as supported is not supported.

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

Audio Design Associates (ADA)

RF Solution for LED Display Screen

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Data Acquisition Instructions

COLOR TFT LCD MONITOR. Manual

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

QUICK START GUIDE. QT Analog HD Camera & DVR Bundle ENGLISH

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

2 Connect your video source

Quick Operation Guide of LTN7700/7600 Series NVR

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

DX-10 tm Digital Interface User s Guide

Med Tips. PRODUCT INFORMATION FreeStyle Battery Warranty. Q: What is the warranty for my FreeStyle Battery?

Transmitter Interface Program

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

CHAPTER 3 EXPERIMENTAL SETUP

Weschler AMT Software for the Enhanced Version Transformer Advantage

1 Synchronising Xsens with the Delsys Trigno EMG System

Electrocardiogram (ECG) Version Date: 2017-FEB-15 Document Effective Date: 2017-MAY-15

How-to Note: Quickstart: ITM9000 [This note applies to ITM9000 (handheld tester)] Contents. Overview. Materials Included

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

CCE900-IP-TR. User s Guide

insors Grid Room System Installation Guide

Quick Start Guide Building and Scheduling a Show

2 Connect your video source

PRECAUTIONS CONTENTS: Please follow these precautions:

Operating Instructions

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Game Show Physiology

Interface sheet - Edan ST-1212 Stress - CPET ergometer

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Installing the P80 Console Media Adapter

22" Touchscreen LED Monitor USER'S GUIDE

Video Server SED-2100R/S. Quick Installation Guide

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

EEG A1452 SCTE-104 Inserter Frame Card

IMPORTANT! This instruction guides you how to install surveillance system.

Installation Note. Agilent 89441A Option AYC Installation Kit

Quick Start Guide for Cisco Digital Media Encoder 2200

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

QUICK START GUIDE. IP Camera & NVR Bundle ENGLISH

SX Series with TRC6 Remote Control User Guide

Using LightSpace CMS for User Created Calibration LUTs

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

Instructions for Use: Video Inspection Scope with Display

U S E R G U I D E HD1000

Audio Integration Note

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

Integration of the Zetasizer µv and OmniFACE into an SEC system

Setup Guide. Klein K-10CP Colorimeter. Rev. 1.1

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

InfiniTV 4 Installation Instructions

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

SXGA096 DESIGN REFERENCE BOARD

CI-218 / CI-303 / CI430

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

medlab One Channel ECG OEM Module EG 01000

Cablecast Server. Setup Guide. c Tightrope Media Systems For Cablecast version Build 74

Agilent 87075C Multiport Test Set Product Overview

MVP. Instruction Manual MVP-50 MVP-100 MVP-150

ASSEMBLY AND CALIBRATION

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

Cisco MX200/MX300/EX90 User Guide

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

3-in 1- out DVI Switcher

Transcription:

Pulse Biomedical QRS-Card Tango M2 Interface Notes To setup Tango M2 with your stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with your stress system. This cable enables your stress system to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the stress system s display and reports. o SunTech Part Number = 91-0013-01 o Connection Ends: Stress System Connection 9 pin female Tango M2 Connection 9 pin female ECG Trigger Cable provides the ECG signal from the stress system to the Tango M2. o Contact Pulse Biomedical o Connection Ends: Stress System Connection RJ45 to 9 pin female Tango M2 Connection BNC male NO PICTURE PBI-QRS Card, Tango M2 Interface Notes Page 1 of 5

Tango M2 Monitor RS-232 Connection Part # 91-0013-01 ECG Trigger Connection Contact Pulse Biomedical 2. Connect the RS-232 Cable From: the RS-232 connection on the rear panel of the Tango M2. To: the serial port on the back of the stress system PC. * Note - For use with a USB port, you will need the USB to RS-232 Adapter Cable - SunTech Part Number = 98-0057-00. 3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the RJ45 splitter that is connected to the QRS-Card. 4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. PBI-QRS Card, Tango M2 Interface Notes Page 2 of 5

d. Using the UP or DOWN arrows, scroll through the list until QRS Card is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. QRS-Card System Setup Note: In order for the QRS-Card Tango interface to work, the software, QRS Card for Windows must have the most up to date version of the file, st_tango.bpd. You can check this using Windows Explorer. Go to the directory in which the software is installed and ensure that the file st_tango.bpd is dated after 7/12/2001. Download the patch from http://www.suntechmed.com/interfacenotes.htm and save the file in the directory where QRS Card for Windows in installed. a. From the file menu bar at the top of the screen, select Procedures > Stress > Setup. b. In the Configure Stress screen on the Stress tab, select Automatic for Blood Pressure, Type. c. Select the appropriate selection for Controlled Device (contact stress system manufacturer). d. Click the Test button under Controlled Device. The software will search the available ports for the Tango and controlled device chosen. You may have to attempt this search more than once in order for the devices to be recognized. e. When the devices are recognized, you can use the Blood Pressure icon to test that the interface between the computer and Tango are working properly. f. Click OK in the Configure Exercise Device window and again in the Configure Stress window to return to the main screen. g. From the file menu bar, select Procedures > Stress > Protocol Update. In the Protocol Update window, you can add BP measurements to the protocols that you use. In addition to the BP measurements that the stress system will prompt the Tango to take, you may prompt the Tango to take one by selecting the BPM icon or pressing B on your keyboard. See the QRS-Card manual for details on editing protocols and controlling the Tango using the QRS-Card software. FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. PBI-QRS Card, Tango M2 Interface Notes Page 3 of 5

c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. 2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). PBI-QRS Card, Tango M2 Interface Notes Page 4 of 5

3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com PBI-QRS Card, Tango M2 Interface Notes Page 5 of 5