Overview: Specifications: Installation Instructions:

Similar documents
SSPT724A Timer Quick Start Guide

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Installation and Operation Manual. YMP Series Signal Programmer

XTM72 Exerciser Timer Module

XTM72E & F Real-Time Clock Modules

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Master Time Clock MTC Users Manual

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Master Clock Controller. User Guide. pyramidtimesystems.com

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

Master Clock Controller. User Guide. pyramidtimesystems.com

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Master Clock Controller. User Guide. pyramidtimesystems.com

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

USER & ENGINEER INSTRUCTION MANUAL

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Model 1476-C SuperQuad HR

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

INSTRUCTION MANUAL HN 50. Master clock MOBATIME BE

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Automatic Transfer Switch Control PLC Operator s Manual

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Instruction Manual for Programmable Digital Timer

Innovative Air Systems ABN When Calling For Support Quote:.doc

Installation Instructions

Using the More Advanced Features of the AUTOcard-SA System

PicoBoo PLUS. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

OPERATION AND MAINTENANCE

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Junior Max (JR Max ) Controller

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

Multifunction Digital Timer

ET BLU MIX RX-Condo-3

Operation Guide 6022 ENGLISH

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

A Motor can be in many groups, by assigning additional channel# on it.

Battery Operated Controllers

video door entry system - installation instructions

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Intelligent Security and Fire Ltd

SAPLING WIRED SYSTEM

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

MODEL 2018 OPERATION MANUAL Firmware Version

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Inserting the batteries. Basic settings of the remote control

7 Day Digital Programmer 3 Channel Surface Mount

AP21 BELL / BUZZER SYSTEMS

VNS2210 Amplifier & Controller Installation Guide

7 Day Digital Programmer

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

USER MANUAL AL-Control 1 PRO

NTC -17E INSTRUCTION MANUAL

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

TDDFM14 OWNER S MANUAL

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

VNS2200 Amplifier & Controller Installation Guide

MSC+ Controller. Operation Manual

ST9100C User Guide. Features

1 Channel Multi-Purpose Programmer User Instructions

Operating instructions. Universal timer switch display

Orbit Marine LED Light with 24 hour Ramp Timer Pro LED Controller

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Ambiflex MF620 USER GUIDE

SELENA Multifunctional LED CLOCK

Single Axis Position Controller

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Radio Thermostat Clock

Transcription:

Overview: The SignalGuys.com Start/Stop Work Timer PT724A is an extremely versatile 24 Hour 365 Day Event Timers designed to support a wide range of applications. Such applications include: Start/Stop Work Time, Home and Building Automation, Security, Lighting Control, Etc. The PT724A timer board is equipped with an independently controlled form C relay contact that provides many latching and/or momentary operations during a program schedule of your choice. The EE prom memory allows for programming of unit prior to/or during field installation. Events may be set for single or multiple operations on a daily and/or weekly schedule. The block programming feature enables repeating an event on any combination of consecutive days. PT724A will compensate for daylight savings time if desired. Individually selected holiday exceptions can be programmed to over-ride regularly scheduled events. Specifications: 120 volts AC operation as wired from Factory. Standby current: 10mA (relay off) 50mA (relay on). Battery charging current: 100mA. Form C relay contacts are rated 10amp @120VAC/28VDC-factory wired for 120 Vac output on contact closure. EE Prom memory protects against loss of programming due to power failure. Accurate crystal controlled clock. Momentary and/or Latching Events. 50 individually programmed daily/weekly events. Block programming capacity can accommodate a total of 350 events per week. 10 programmable Holiday dates. First man in option. Alphanumeric LCD display simplifies programming. Standard or Daylight Savings Time settings. Automatic compensation for leap year. Built-in charger for 12VDC sealed lead acid or gel type batteries (Max charge current 100mA). Lithium battery backup maintains clock. Enclosure Dimensions (approximate): 8.5 H x 7.5 W x 3.5 D Installation Instructions: 1. Mount Unit in desired location. Carefully Review: Basic Operation (pg. 2-3) Terminal Identification Table (pg. 3) Push Button Layout and Description(pg. 3) Programming Instructions (pgs. 4-6) 2. Connect 120 volts AC using AC power cord, or hardwire as desired.. 3. Connect 12VDC battery (optional, for unique applications) to terminals marked [+ BAT -- 12VDC]. 4. Lithium battery is already installed. 5. Connect devices to be controlled to the 120 Volt AC outputs marked [NO, C,]. Note:Th device is wired for 120 Volt AC output to Horns, etc, When DC powered electromechanical devices such as Mag Locks, Electric Strikes, Relays, etc. are to be installed, install a catch diode across the pos (+) and neg (-) terminals of the device. Connect diode as close to the device as possible with the banded side facing the pos (+) terminal. This will reduce the possibility of interference. You must also remove the 120 VAC input connections to the Contacts. 6. Program clock and desired event schedule (see programming instructions pg. 4-6). Basic Operation: PT724A controls an independently operated dry form C relay output. Relay can be programmed to: turn on (latch), turn off (release latch) or pulse (momentary toggle), the PULSE is used for start stop work timer applications at a specified time and day (this is referred to as an event). Events are programmed via the push buttons and LCD display. Events may be programmed to occur on any day of the week at any time. In addition, events may be repeated at a specific time on two (2) or more consecutive days (i.e. M-F, Sun-Th, etc) Multiple combinations of individual and block events may be programmed. Holiday exceptions are individually selected by date and will over-ride all regularly scheduled events. - 2 -

The four (4) output relay modes consist of: Relay OFF - De-energizes the relay until a relay ON event is detected Relay ON - Energizes the relay until a relay OFF event is detected. Disable - Used to cancel an existing programmed event. Start/Stop Work Applications*** PULSE - Momentarily energizes the relay for a selectable time period of 1 sec. to 15 secs. Time is displayed in 24 hr. military format. Terminal Identification Table: Terminal Legend Function/Description NO, C, NC Dry Contact output used to switch controlled devices. When these relays are energized (ON) the NC and C terminals are open and the NO and C terminals are closed. When this relay is de-energized (Off) the NC and C terminals are closed and the NO and C terminals are open. + DC -- AC or DC Input 12 to 24 volt. When using DC carefully observe polarity. This is already wired. ~ AC ~ to the transformer by the factory--no changes are required-standard use + BAT -- 12VDC standby battery input (battery leads provided). Rare applications for this option 12VDC FM When this terminal is connected to DC neg. (-) the First Man in feature is enabled. The relay will remain in its present position until this connection is terminated. At that time the relay will resume normal operation and latest scheduled events will occur. Fig. 1 NO C NC RELAY ON SU 01:01 + DC --- AC + BAT --- 12VDC FM SET ENTER UP DWN AC Transformer Factroy Installed Lithium Battery Socket (2032) } Push Button Layout Push Button Description Table: Push Button SET ENTER UP DWN Function/Description Scrolling keys for programming. Escaping out of existing programming. Accepts selections made to programming. Scrolls through selections. Scrolls through selections. UP and DOWN keys can be used to select data entries. After scrolling to the correct entry, depress accept. - 3 -

Programming Instructions: A. Setting Clock/Calendar: Upon initial power up RLY OFF SU 01:01 Depress SET SET TIME 01/01/01 SU/01:01 Enter the current date, day of week and time (military) by depressing UP and DWN to make the selection then depress accept. Next select either DS (daylight savings mode) or ST (standard time mode) by depressing set until SET BK Depress scroll until flashing cursor appears under DS (daylight savings mode) in display. To change mode depress UP or DWN once ST (standard time mode) Depress accept correct selection. Note: The flashing cursor denotes location of data entry selection to be made. If an entry was made in error or requires changing, depress SET to backspace, make the correct selection and depress accept data and advance the cursor. To change or program clock/calendar simply repeat the steps above. B. Setting Events: #01 OFF SU 00:00 until the flashing cursor appears under OFF in display. Now select type of event required, by scrolling using the UP and DWN push buttons until either: ON - Relay ON (latching mode). OFF - Relay OFF (latching mode). PL - Relay Pulse ( momentary). appears in display and depressing ENTER will make selection. When selecting the pulse mode PL01 will appear in the display. It is now necessary to assign the length of time (duration of relay activation). The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons, then depressing accept. Note: If pulse duration is not selected relay output defaults to 1 second. Next select the day of the week and time (military) by scrolling using UP and DWN push buttons and depress accept. You may continue to program events by repeating the previous steps or exit programming by depressing SET. Note: When programming additional events it is necessary to select the next consecutive event number following the last event program to continue. Note: When it is required to have the same event repeated on two (2) or more consecutive days of the week (Block Programming), enter the first day followed by the last day by depressing SUN through SAT. Example: 1) Monday through Thursday depress MON followed by THURS. 2) Wednesday through Sunday depress WED followed SUN. - 4 -

C. Setting Block Events (weekly repeat): SET BK BK=SA/SU TIME=DS Flashing cursor will appear at the location of the first day of the week desired. Depress UP and DWN to select day. Depress confirm selection, then cursor will appear at the location of the last day of the week desired. Depress UP and DWN to select day. Depress confirm selection. again to escape. D. Setting Holiday Events: Depress SETuntil #01 ON HL 00:00 Next select HL to indicate as holiday event and time by scrolling using UP and DWN push buttons and depress accept. You may continue to program more holiday events by repeating the previous steps or exit programming by depressing SET. E. Setting Holiday Dates: It is now necessary to assign these holiday events specific calendar dates which they are to occur. To select Holiday events depress SET until SET HOL #01 HOL SU 00:00 Note: Holiday events will override all regularly programmed events. F. Delete/Disable Events or Edit Events: Previously programmed regularly scheduled and/or holiday events may be deleted/disabled without having to erase all events. #01 ON TU 00:00 Now scroll using UP and DWN push buttons to the event you wish to delete, depress move flashing cursor under relay option then depress UP and DWN push buttons until DIS is displayed, depress confirm. - 5 -

G. Delete All Events: All previously programmed events can be deleted by depressing SET until CLR MEM CLEAR MEMORY? PRESS UP & ACCEPT Depressing UP push button will now clear all events previously programmed. If you wish to escape from this selection depress any of the other push buttons: SET, ENTER and DWN.