m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

Similar documents
Achieving More Efficient Data Review with OpenLAB CDS

Peak Detection with Varian Star Workstation for Varian 3800 and 450 Gas Chromatographs

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

Peak Detection with Varian MS Workstation for Varian 220 and 240 GCMS

Advanced Test Equipment Rentals ATEC (2832)

Sources of Error in Time Interval Measurements

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

PulseCounter Neutron & Gamma Spectrometry Software Manual

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

Time Domain Simulations

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

GCxGC Comprehensive Two-Dimensional Gas Chromatography

1 Introduction Steganography and Steganalysis as Empirical Sciences Objective and Approach Outline... 4

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

Overview and Interpretation of D7900/D7169 Merge Analysis

Dither Explained. An explanation and proof of the benefit of dither. for the audio engineer. By Nika Aldrich. April 25, 2002

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

Precision testing methods of Event Timer A032-ET

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Cycle-7 MAMA Pulse height distribution stability: Fold Analysis Measurement

Full Disclosure Monitoring

Analysis of WFS Measurements from first half of 2004

Practical Bit Error Rate Measurements on Fibre Optic Communications Links in Student Teaching Laboratories

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

The Measurement Tools and What They Do

4 MHz Lock-In Amplifier

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

base calling: PHRED...

GC/LC-MS: data acquisition rate and peak reconstruction

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Signal Stability Analyser

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Agilent 5345A Universal Counter, 500 MHz

DCI Requirements Image - Dynamics

Accuracy Delta Time Accuracy Resolution Jitter Noise Floor

TABLE OF CONTENTS. Instructions:

Lecture 2 Video Formation and Representation

DISTRIBUTION STATEMENT A 7001Ö

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

DETECTING ENVIRONMENTAL NOISE WITH BASIC TOOLS

Update on Antenna Elevation Pattern Estimation from Rain Forest Data

LHC Beam Instrumentation Further Discussion

Page I-ix / Lab Notebooks, Lab Reports, Graphs, Parts Per Thousand Information on Lab Notebooks, Lab Reports and Graphs

Student Laboratory Experiments Exploring Optical Fibre Communication Systems, Eye Diagrams and Bit Error Rates

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Python Quick-Look Utilities for Ground WFC3 Images

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

Characterisation of the far field pattern for plastic optical fibres

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Contents. xv xxi xxiii xxiv. 1 Introduction 1 References 4

BER MEASUREMENT IN THE NOISY CHANNEL

T sors, such that when the bias of a flip-flop circuit is

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

Tutorial on Technical and Performance Benefits of AD719x Family

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

MICROWAVE MEASURING INSTRUMENTS

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

MICROLINK 304x A-D Converter User Manual

Chapter 5 Flip-Flops and Related Devices

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Type-2 Fuzzy Logic Sensor Fusion for Fire Detection Robots

CHAPTER-9 DEVELOPMENT OF MODEL USING ANFIS

PICOSECOND TIMING USING FAST ANALOG SAMPLING

Analogue Inputs Resolution Assignment

RF (Wireless) Fundamentals 1- Day Seminar

Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling

SigPlay User s Guide

homework solutions for: Homework #4: Signal-to-Noise Ratio Estimation submitted to: Dr. Joseph Picone ECE 8993 Fundamentals of Speech Recognition

The Definition of 'db' and 'dbm'

Pre-processing of revolution speed data in ArtemiS SUITE 1

Scout 2.0 Software. Introductory Training

SC24 Magnetic Field Cancelling System

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Novel Digital Pileup Inspection Circuit for a Gamma Ray Spectroscopy System

BUREAU OF ENERGY EFFICIENCY

NENS 230 Assignment #2 Data Import, Manipulation, and Basic Plotting

Renishaw Ballbar Test - Plot Interpretation - Mills

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

SC24 Magnetic Field Cancelling System

AIM INTRODUCTION SIMPLIFIED WORKFLOW

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Chapter 6. Normal Distributions

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

Assessing and Measuring VCR Playback Image Quality, Part 1. Leo Backman/DigiOmmel & Co.

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

Transcription:

m RSC CHROMATOGRAPHY MONOGRAPHS Chromatographie Integration Methods Second Edition Norman Dyson Dyson Instruments Ltd., UK THE ROYAL SOCIETY OF CHEMISTRY

Chapter 1 Measurements and Models The Basic Measurements Measurements and Their Use Quantitation Peak Area and Peak Height Peak 'Volume' Retention Time and Solute Identity Column Hold-up Time Diagnostics and System Suitability Tests Baseline Noise Baseline Signal Level Peak Boundaries Peak Width and Column Efficiency Peak Asymmetry Peak Resolution Retention Time Stability Results Assessment Correct Peak Measurements Total Peak Area Correct Number of Peaks Coefficient of Variation and Relative Standard Deviation Comparison Against Standards Trend Analysis Performance Measurement Chromatograph Utilization Analyst Workload Cost per Analysis Chromatographie Peak Models The Gaussian Function The Function Peak Height Ratio of Area/Height Calculation of Peak Width at Various Heights Gaussian Peak Shape Tests The Points of Inflection 1 1 1 1 3 4 4 4 5 6 6 6 7 9 10 10 10 10 12 12 12 13 13 14 14 15 16 16 IX

Fractional Peak Area Bounded by Various Widths 17 Loss of Area from the Base of a Gaussian Peak 18 Gaussian Peak Maximum as an Approximate Parabola 18 The Exponentially Modified Gaussian Function 20 The Function 20 Practical Application of the EMG Function 22 EMG Peak Shape Tests 23 Statistical Moments of a Chromatographie Peak 23 Zeroeth Moment, m 0 24 First Moment, m\ 24 Second Moment, w 2 25 Third Moment, m 3 25 Fourtli Moment, m 4 26 Higher Odd Moments 27 Higher Even Moments 27 Measurement of Peak Moments 27 Practical Disadvantages and Uses 27 Manual Peak Area Measurement 28 Height XWidthatHalfHeight 28 The Condal-Bosch Area 29 Peak Area by Triangulation 30 Manual Measurement of Asymmetrie (EMG) Peaks 31 References 33 Chapter 2 Errors in Peak Area Measurement 35 1 Accuracy and Precision 35 Accuracy 35 Precision 35 Inaccuracy and Uncertainty 35 Repeatability 36 Reproducibility 36 Random Errors 37 Systematic Errors 37 Spurious Errors 37 Causes of Imprecision 37 Causes of Inaccuracy 37 Precision of Integrator Measurements 37 2 Accurate Representation of the Solute Profile 39 Additivity of Signals 40 Negative Detector Signals 41 Electronic Peak Distortion 41 3 Peak Area and Solute Quantity 43 Mass and Flow Sensitive Detectors 43

Flow Sensitive Detectors Mass Sensitive Detectors Detector Overload Linearity Detector Non-linearity Column Non-linearity Electronic Noise and Drift Sources of Peak Measurement Error Hardware Errors Noise Noise and Frequency Short-term Noise Long-term Noise Drift Errors Created by Noise Signal-to-noise Ratio: The Smallest Measurable Peak Limits of Detection and Quantitation A 'Good Baseline' Errors Created by Baseline Drift Drifting Baseline and Peak Measurement Baseline Drift and Retention Time Reduced Detector Operating Range Some Preliminary Conclusions Errors of Incomplete Peak Resolution Height of a Fused Peak Perpendicular Separation Effect of Overlap on Area Measurement Accuracy Error Correction Strategies Error Propagation through Overlapping Groups Peak Overlap and Calibration Tangent Skim Errors Errors of Perpendicular/Tangent Transition Overlapping Peaks on Sloping Baselihes Multiple Fused Peaks Mathematical Deconvolution of Overlapping Peaks The Isomer Test Errors from Peak Asymmetry Asymmetry and Peak Tailing Asymmetry and Base Broadening Asymmetry and Manual Peak Measurement Unequal Asymmetry The Achievement of Accuracy in Chromatographie Analyses Peak Area vs. Peak Height User Surveys References 44 45 47 48 49 49 50 50 50 53 54 55 55 56 56 58 59 60 60 62 62 64 67 68 70 71 72 72 74 76 77 78 78 80 80 81 82 83 85 86

xii Contents Chapter 3 Manual Measurement of Peaks 89 Representation of the Detector Signal by Chart Recorder Slow Response Time Non-linear Signal Response Pen Head Damping Amplifier Noise Manual Measurement of Noise Dead Band Chart Motor Control Attenuator Accuracy Measurement Strategies Counting Squares Cutting and Weighing Planimeters Measurements based on a Peak Model Pencil and Rule Methods Measurement of Peak Height Height vs. Area Measurements Triangulation Peak Height X Width at Half Height Condal-Bosch Variation The Foley Variations Measurement of Overlapping Asymmetrie Peaks Peak Shape Tests Errors of Manual Measurement Optimum Peak Shape Advantages and Disadvantages of Manual Peak Measurement References 89 89 89 90 90 91 91 92 92 92 93 93 94 94 95 95 95 96 97 98 99 101 101 101 103 105 105 Chapter 4 Digital Integrators 107 1 ABrief History of Integrators 107 Strip Chart Recorder Techniques 107 Electromechanical Counters 107 Electronic Integrators 0 TTL Instruments - The First Electronic Integrators 0 Microprocessor-based Integrators 1 Integrators with Printer Plotters 1 The Impact of the Microcomputer 2 2 Current Integrator Status 2 Standard Integrator Specification 3 Integrator Files 4 Analysis Parameters for Peak Measurement 4 Peak Width 5

Slope Sensitivity or Detection Threshold Baseline Drift Tolerance Time to Double Minimum Area or Height Threshold Analysis Duration Integrate Inhibit Forcing Tangent or Perpendicular Separation Forcing Baseline Detection Horizontal Baseline Projection Inverting Negative Peaks Instrument Control and Communications Sample Management, Calculations and Calibrations Peak and Solute Identity Relative Retention Times Standard Calculations Area% or Normalization Internal Standard Extemal Standard Sample Scheduling Calibration Report Preparation and Output Trends Report Distribution Validation of Integrators The Integrator as a Diagnostic Tool Specification, Installation, Operational, Performance Qualification Integrator Specification and Selection (SQ) Installation Checks (IQ) Operational Qualincation (OQ) Validation and Calibration: The Difference Records Performance Qualification (PQ): Regulär Testing of the Integrator Logging Results Validation of Software Standard Chromatograms Creation of Standard Chromatograms Computer-based Standard Chromatograms Specification of Standard Chromatograms Creation of Synthetic Chromatograms Baselines Baseline Noise Drift Traceability of Synthetic Chromatograms References 5 7 7 8 8 8 8 120 120 122 123 123 123 124 124 124 125 125 126 126 127 128 128 129 129 130 130 131 132 132 132 133 134 134 135 136 136 137 137 137 137 138 138 138

xiv Contents Chapter 5 Digital Measurement of Peak Areas 140 1 Signal Sampling 140 Analogue to Digital Conversion 140 Voltage to Frequency Conversion 140 Dual Slope, Integrating A/D Conversion 141 Resolution of A/D Converters 143 Auto-ranging of A/D Converters 143 Data Sampling Frequency 144 Sampling Frequency and Integrator Manufacture 144 Sampling Frequency and Data Processing Algorithms 144 Data Bunching 144 Baseline Bunching 145 Estimating the A/D Sampling Frequency and Bunch Size 146 Data Bunching and the Peak Width Parameter 148 Peak Width Parameter and Analysis Reprocessing 148 Peak Sampling Synchronization 149 Rounding or Truncation Errors 149 Aperture Time Jitter 149 2 Filtering and Smoothing the Chromatographie Signal 150 Filtering 150 Smoothing 150 Electronic Filters 150 Sampling Frequency and Mains Coupling 150 Smoothing Techniques 1 Digitizing and Integrating 1 Bunching 1 Moving Windows and Polynomial Curve Fitting 153 Optimum Filtering 154 Signal Subtraction 155 Chromatogram Plotting 157 Matched Filtering 15 7 3 Location and Measurement ofpeaks 158 Finding the Peaks 159 Retention Time 160 Peak Shape Test 160 Properties of the Smoothed Data 160 Data Integrals 161 Baseline Fluctuations and Slope Sensitivity 162 Programming Slope Sensitivity 162 Slope Sensitivity and Representative Baseline 162 Updating Peak Width and Slope Sensitivity during Analyses 163 Location of the Limits of Integration 163 Small Peak Filtering 165 Location of Peak End 165

Measurement of Peak Area 166 Baseline Convention 168 Measurement of Peak Height 168 Measurement of Retention Time 168 Measurement of Two Unresolved Peaks 169 Measurement of Individual Peak Areas 170 Peak Measurement Diagnostics 170 Measurement of FusedGroups 170 Shoulders 171 Measurement oftangent Peaks 172 Tangent Skimmed Groups 173 Small Peaks between Larger Ones 174 Tangents on Tangents 175 4 Baselines, A More Detailed Discussion 175 Baselme Drift Limit 175 False Starts 177 Formulating a Baseline Definition 177 Mis-timing 'Start' and 'End' 178 End of Tntegrate Inhibit' 178 Forcing Baseline 179 Incorrect Programming of Baseline Drift Tolerance 180 Fused Tangent Measurement 182 Single Peaks on a Rising Baseline 183 Valleys Between Fully-resolved Peaks 184 Negative Dips and Constructed Baselines 184 Assigning Baseline Beneath the Whole Chromatogram 187 Valley-Valley Skim 190 5 Conclusions 190 6 References 191 xv AuthorIndex 193 Subject Index 196