Professional-Practice

Similar documents
Operating instructions III / 2004

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Luminaire installation box Surface-mounted box Ceiling installation box

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

15 Series - Dimmer

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies

R xx-C0900-J074

QTi DALI 2X14/24/ DIM

R Rxx-Vxxxx-L334-x

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Gamma instabus. Technical product information

STX Stairs lighting controller.

SceneStyle2 User Guide

LEDVANCE DOWNLIGHT LED

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

QTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Tri-level Control HF Sensor

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Ultra thin LED lamp for Pool & Spa OWNER S MANUAL

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Lumencove Family. The highest quality light from the tightest spaces

OP5. Preprogrammed, configurable controller for simple applications

2-output DALI controller

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

Figure 1: Device components

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

The systematic way to get more light In most cases, the lamp developments are effectively system developments as they also involve modern electronic

KNX Dimmer RGBW - User Manual

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Technical Information

Instruction manual. DALI Gateway art Installation manual

L xxx-C0720-K255

SAUTER flexotron RDT405 Manual

As versatile as your requirements.

Operating Instructions Dimmer for V Incandescent Lamps

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

SOFT LED 4 Vari-White INSTRUCTION MANUAL

CoreLine Panel the clear choice for LED

2X2 Panel. 1X2 Panel

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Dimming actuators GDA-4K KNX GDA-8K KNX

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Aspect 2 Circuit Digital Scene Control

SPECIFICATION SHEET lumencove

Catalogue Ignitors and power switches for HID

Efficiency Meets Lighting Quality LG LED Downlight

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Operation Manual. Model: CFR-2027 Dimmable Energy Saving Light bulb (Receiver built-in)

Operating Manual. Basic Control BC16. two-channel for eco moon

QUICKTRONIC INTELLIGENT DALI DIM T8

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

Simple all-in-one design style with front stereo speakers and natural ventilation system

Wi-Fi Lighting Controls ELECTRONIC GMBH

POWER LINE BAR SERIES DA PL6 WW NORA

feno before light and beyond

OPTOTRONIC Intelligent

Features. High Brightness SMD LED Light source

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Wi Fi Mood Lighting. As supplied

Label Applicator HERMA 400

Cyclo Series. user manual. MartinArchitectural

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Absolute Rotary Encoder E6CP

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LED MODULES READYLINE DL

Emergency lighting units EM powerled

Linealux L5 Linear Facade

USER MANUAL. Kramer Electronics, Ltd. Models:

The most cost-effective full window design delivering uniform light

2x2 DUAL COLOR LED SOFTLIGHT

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LED Driver Constant voltage

The body of this product adopts distinctive style design with smooth lines, fine appearance and so on. The whole lamps and lanterns look very good.

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Operating instructions Electronic preset counter Type series 717

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Emergency lighting units EM powerled

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Capacitance Limit Detection nivotester FTC 420/421/422

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Siteco Service Box User Manual 1/31

LED Backlight for Technics amplifiers

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED

SubstiTUBE Value ST8-HV5

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Transcription:

www.osram.com/ecg-lms Professional-Practice DALI MCU: Digital potentiometer with DALI Manual lighting control with the DALI MCU for rooms with grouped luminaires with as many as 50 ECG, with or without dividing wall Content 01 Application 02 Setup/Function of components 03 User benefits 04 Installation 05 Wiring for a conference room 06 Operation 07 Other fields of application 08 Technical data 1. Application Consider you want to switch on/off and dim the light in a room, a restaurant or bar, a foyer or lounge etc but you want to do it from either of its two doors, no matter which. For this to work, the two control points would have to operate synchronously in such a fashion that the lighting system responds immediately and harmoniously when the brightness level is changed at either of the control devices. With the DALI MCU digital potentiometer, it is easy to meet such requirements. The parallel connection between the two devices (control points), which would be required for our example to work, becomes super simple and it does not necessitate any demanding installations and/or additional control components. Each control circuit simultaneously affords the integration of as many as 50 luminaires and of up to 4 DALI MCU control devices (control points). And all that while allowing for the required comfortable, easy and complete control over the lighting levels at any time. 1

2. Setup/Function of components The components in our example (page 1) above comprise the following:: 12 ceiling lamps, fitted with DALI ECG (e.g. QTi DALI DIM) 2 DALI MCU control devices, which will be integrated in standard flush-mounting electrical boxes.. In installations with 2 to 4 parallel-connected DALI MCU control devices, the command triggered by the device last operated, will determine the current switching state and/or the brightness value in the room. At the same time, the command is transmitted to the other devices, which will automatically tune to the same value. Subsequent changes of lighting levels from another control point will therefore not cause any annoying side effects such as sudden changes in luminous power because of different switching positions of the other control points that may have been operated previously. Figure 2: DALI wiring layout 2

3. User benefits Lighting levels in the room can be controlled from any of the two control points. The control device most recently used will determine the current operating condition of the entire lighting system, i.e. of all luminaires and control devices integrated into that control circuit. Use of the control devices is really simple, because: switching the light on/of is by single pressure of the rotary knob and by turning the rotary knob to the left or right, you can set the required brightness value. Moreover, you can also ask the DALI MCU to store a particular brightness value by double-pressing the rotary knob (double-click). The next time the light is turned on, the system will then automatically return to this lighting level. The digital potentiometer has no mechanic turning limit in either direction and brightness values are set in small individual mechanical steps. Therefore, the required brightness can be set comfortably and accurately at a high resolution. 3

4. Installation The installation used in our example (figure 2) should be done as follows The mains supply to the luminaires and to one of the two DALI MCUs control devices may run through the same or through different phases (by means of a single conductor or by a 5-pole NYM cable). In our circuit, one of the two DALI MCUs control devices must be supplied with 230V mains power. The second control device will operate without a separate mains supply in the same control circuit. With this setup, you can control up to 25 ECG independent of their power consumption. Each DALI ECG comes with the interface that has a power consumption of approx. 2mA. The internal power supply of a DALI MCU connected to the mains will provide approx. 52mA enough to supply up to 25 ECG and another DALI MCU not connected to the mains.the following wiring diagram (figure 3), for example, shows that the control device labelled Door A has a mains connection. Likewise, the control device Door B could get the mains connection instead. This wiring diagram is based on the use of a 5-pole NYM cable and supply for the entire lighting system through one Phase (L and N). 4

5. Wiring Figure 3: Wiring scheme of a conference room You can control up to 25 ECG with this setup (figure 3). If you also connect the second control device to the 230V mains, you can operate up to 50 luminaires and two additional DALI MCUs without mains connection in one and the same control circuit (i.e. 4 control points in total figure 4). However, it is not permissible to connect more than two control devices in the same control circuit to the mains. 5

Figure 4: Wiring scheme with 4 control points for addressing up to 50 ECG Laying the control line in indoor installations is generally not difficult. For the two control wires (DALI signal), you can use two wires in the same 5-pole NYM cable that provides the mains supply. You may chose any arrangement for the parallel wiring, but a closed circuit of the control line is not permissible. Moreover, the total running length of the control line must not exceed 300m. It is important to observe correct polarity of the feed cables when connecting the control line with two or more DALI MCU control devices. Because each of the devices has its own power supply, the connections must not be mixed up i.e. the positive wire must be connected to Da+ and the negative wire must be connected to the Da- connector of the control device. Erroneous wiring, however, will not destroy the device, because the DALI MCU comes with an inverse-polarity protection feature however, correct operation will only resume when the wiring has been corrected to match device polarity. It is not necessary to observe control line polarity on the ECG side. 6

6. Operation The digital potentiometer comes with two different features: it responds to button pressure and left/right rotation without a mechanical end point (incremental encoder). Short pressure on the rotary knob will switch the light on/off, and anticlockwise rotation of the knob (turn to the left) will cause a reduction of brightness, while clockwise rotation (turn to the right) will increase brightness. Storing switch-on brightness As you switch the light off with a short pressure of the rotary knob, the DALI MCU will store the current brightness value. This value will be recalled when the light is switched back on the next time. However, the DALI MCU control device also allows you to store a fixed switch-on value, which will be recalled every time the light is switched on, irrespective of the value which the system was set to as the light was switched off. Storing the switch-on value is very easy: simply turn the knob to the required brightness and then store the value by briefly pressing the rotary knob twice (double-click). To confirm that the DALI MCU has stored the value, all connected lamps will briefly brighten once. Irrespective of the brightness value last used (but not stored) before the lights were switched off, the system will automatically set brightness to the level stored by the DALI MCU. Setting a basic brightness level We recommend setting a basic brightness level (minimum dim setting) of the lamps when using the system for the first time. To do so, take the following steps: Reduce brightness when the light is on until you can no longer determine any further reduction of the luminous power. Press the rotary knob for a longer time (approx. 10s) to tell the DALI MCU to store this value as the basic brightness level. Again the lamps will briefly brighten once to confirm that the value has been set. If you do not set a basic brightness level, the DALI MCU might under certain conditions trigger lighting levels that are outside the dimming range of the connected ECG. To increase the luminous power in such a case, you would have to turn the rotary knob way to the right until sufficient power is put out this can be a nuisance. RESET: If you want to reset the system to its default settings with a dimming range of 0 100 %, switch off the light by briefly tapping the rotary button and then press the knob for about 10 seconds while the lights are still off. Again all connected lamps will briefly brighten once to confirm that the DALI MCU has been reset. RESET: Of course you can also reset the system to its default setting in which the brightness value used before switching-off the light will be restored when the light is switched back on the next time. To do so, switch off the light by pressing the rotary knob once and double-click it while the lights are still off. Again all connected lamps will briefly brighten once to confirm that the DALI MCU has been reset. 7

7. Other fields of application Consider you have a similar room with a retractable dividing wall, such as a conference room, a public hall or a restaurant. When the dividing wall is closed, you want both sections of the room to be individually dimmable and you want to be able to switch lights off/on in either section independently. When the dividing wall is open, however, you want to control lighting synchronously across the entire room (both sections) from any of the control points. To achieve this, you would set up one DALI control circuit in each of the sections You would then connect one control device in each section (figure 5) to the mains, and optionally, you could also install a second control device without mains connection in each of the sections. One DALI MCU control device in each of the two sections must have a mains connection to make sure that it can supply its assigned control circuit when the dividing wall is closed. When the dividing wall is closed, the position switch is in open position, so the connection between the two control circuits is broken. Then, lighting can be controlled and dimmed in both sections independently. When the dividing wall is open, the position switch is in closed position and the control circuits in both sections and their corresponding control points are turned into one single parallel-connected control circuit. You will therefore be able to control all lamps in both sections simultaneously. Please pay special attention when connecting the control lines to the terminals of the DALI MCUs (polarity!). Single-pole interruption of the DALI control line via the position switch is generally permissible. It does not matter, which of the two control wires (Da+ or/and Da-) is used for switching or whether both are used. As soon as the previously closed dividing wall is opened connecting the previously interrupted DALI cable between the control devices in both sections illumination levels in both sections will adjust to a uniform brightness within approx. 10 seconds. The brightness level will match the level previously set in one of the sections. Turning the knob on any of the DALI MCUs will then change the lighting in the entire room based on this previous level. Figure. 5: DALI wiring layout in a dividable room 8

Figure. 6: Wring scheme of a room with partition Additional interesting uses of the DALI MCU include dimmable individual luminaires, groups of luminaires, custom settings in RGB colour mix systems with designer lamps or decorative lamps, and the control of fluorescent lamps with different colour temperatures in daylight luminous ceiling applications, LED colour tile systems or in illuminated displays (signage). 9

8. Technical data Designationg DALI MCU Order reference (EAN) 4008321189721 Power connection L, N Operating voaltage 230 V AC, 50-60 Hz Power consumption 3 W max. DALI connection da+/da-, max. 300 m cable legth,25 DALI ECG max. Perm. Cable cross-section 1 4 mm 2 Ambient temperature 0 +50 C Type of protection IP 20 Protection class II CE requirement EMC to EN 61547, low voltage to EN 60628 10