Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Similar documents
Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Capacitive sensor BCT5-S18-UP6X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Read/Write Head TNSLR-Q42TWD-H1147

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Read/Write Head TNLR-Q80L400-H1147L

Read/Write Head TN-CK40-H1147

Read/write head TN-CK40-H1147

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Read/Write Head TN-M30-H1147

Read/write head TN-M18-H1147

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

Process transmitter RMA422

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Pressure sensors with display

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

APPLICATIONS. Automatic warehouse. Trasportation lines

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Mobile data carrier TW-L49-46-F-B128

Quality products from a single source

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Inductive coupling. 10 mm +/-0.2 mm

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Capacitance Level Measurement Electronic insert FEC 12

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

EtherCAT Set in IP20 TI-BL20-E-EC-S-4

Process Transmitter RMA 422

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

DMP 331i / DMP 333i LMP 331 i

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

ATEX-manual for units

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

The full range of performance

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Photoelectrics Through-beam Type PA18C.T..., DC

Connectivity for Ethernet

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

TFRN Industrial RTD temperature sensor. CombiTemp TM

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

TFRN Industrial RTD temperature sensor. CombiTemp TM

APPLICATIONS. Automatic warehouse. Trasportation lines

PMG. Vibration Energy Harvesters

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

3 Cleaning. 4 Technical data

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Pressure transmitter For applications in hazardous areas Model IS-3

Datasheet - SRB-E-201ST

Quality products from a single source

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Set for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2

RSCC. Load cells. Special features. Data sheet

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

>Inductive and. REFERENCE guide. Capacitive Sensors

PROPORTIONAL VALVES Sentronic plus

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Transcription:

ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) Cable connection Wiring Diagram Type designation Ident no. 10560 Pass speed ð 10 m/s Repeatability ï ± 0.1 mm Temperature drift ð 0.1 mm Hysteresis ð 1 mm Ambient temperature -25 +70 C Output function Switching frequency Voltage Current consumption non-actuated Actuated current consumption Approval acc. to 2-wire, NAMUR 1 khz Nom. 8.2 VDC ð 1.2 ma ï 2.1 ma KEMA 02 ATEX 1090X Functional principle Magnetic field sensors are activated by magnetic fields and are especially suited for piston position detection in pneumatic cylinders. Based on the fact that magnetic fields can permeate non-magnetizable metals, it is possible to detect a permanent magnet attached to the piston through the aluminium wall of the cylinder. Design Dimensions Housing material Active area material Electrical connection Cable quality Rectangular, IKT 30 x 14.6 x 17 mm Metal, GD-Zn Plastic, PA12-GF30 Cable 5.2 mm, Blue, Lif9YYW, PVC, 2m Cable cross section 2 x 0.25 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Mounting on the following profiles. Cylindrical design F G H Switching state LED yellow 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Mounting instructions/description Active face in the middle 2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLI1 69710 Mounting on F tie-rod cylinders; cylinder diameter 32 100 mm; material: Die-cast zinc KLI3 69712 Mounting on F tie-rod cylinders; cylinder diameter 63 160 mm; material: Die-cast zinc KLI5Z 6971803 Mounting on F tie-rod cylinders; cylinder diameter 32 63 mm; material: Aluminum KLI6Z 6971806 Mounting on F tie-rod cylinders; cylinder diameter 50 125 mm; material: Aluminum KLI5 6971802 Mounting on G profile cylinder; cylinder diameter 32 50 mm; material: Aluminium 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLI6 6971805 Mounting on G profile cylinder; cylinder diameter 50 100 mm; material: Aluminium KLI7 6971810 Mounting on H profile cylinder with external dovetail grooves; diameter 32 200 mm; material: Aluminium IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 2 G and Ex ia IIC T6 Gb and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25 +70 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com