PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Similar documents
Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Overview: Specifications: Installation Instructions:

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

SSPT724A Timer Quick Start Guide

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

XTM72E & F Real-Time Clock Modules

XTM72 Exerciser Timer Module

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC Users Manual

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

INSTRUCTION MANUAL HN 50. Master clock MOBATIME BE

Installation and Operation Manual. YMP Series Signal Programmer

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Master Clock Controller. User Guide. pyramidtimesystems.com

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

Instruction Manual for Programmable Digital Timer

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

1 Channel Multi-Purpose Programmer User Instructions

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

Junior Max (JR Max ) Controller

Radio Thermostat Clock

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

Model 1476-C SuperQuad HR

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Installation Instructions

7 Day Digital Light Switch with Optional Dusk Start

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

ET BLU MIX RX-Condo-3

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

WDK-2500-STROBE. User Guide

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Intelligent Security and Fire Ltd

MSC+ Controller. Operation Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Operating instructions. Universal timer switch display

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Battery Operated Controllers

TDDFM14 OWNER S MANUAL

Innovative Air Systems ABN When Calling For Support Quote:.doc

Access Control Keypad for MK-DV, JB-DV

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

video door entry system - installation instructions

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Automatic Transfer Switch Control PLC Operator s Manual

Operations. BCU Operator Display BMTW-SVU02C-EN

REV 303 PROGRAMMABLE MULTIFUNCTIONAL TIMER. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics OPERATING MANUAL.

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

Installation & Programming Manual. Please read before using this timer.

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

NTC -17E INSTRUCTION MANUAL

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Using the More Advanced Features of the AUTOcard-SA System

QUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL

ST9100C User Guide. Features

Night Hawk Firing System User s Manual

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

KF200 PORTABLE MANUAL

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

MODEL 2018 OPERATION MANUAL Firmware Version

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

AUTOPILOT DLM Satellite Downlink Manager USER GUIDE

DMX OPERATOR PRO. User Manual

Digital Time Switch. Installation & Operating Instructions

ST625TX Digital Room Thermostat

SCENEMASTER 3F QUICK OPERATION

Radio-control universal dimmer (built-in type) Installation Instructions

Operation Guide 6022 ENGLISH

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Programmable time switches Multiple function - daily/weekly

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

7 Day Digital Time Switch

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Active UTP Transceiver Hub Installation Guide

Art M Digital codelock module

Transcription:

PT2724 - Two (2) Channel 365 Day 24 Hr. Timer/Controller Overview: This unit is an extremely versatile two channel 365 Day 24 Hour Timer / Controller designed to support a wide range of applications. Such applications include: Home and Building Automation, Security, Access Control, Lighting Control, Etc. The PT2724 is equipped with two independently controlled form C relay contact that provides many latching and/or momentary operations during a program schedule of your choice. The EE-Prom memory allows for programming of unit prior to/or during field installation. Events may be set for single or multiple operations on a daily and/or weekly schedule. The block programming feature enables repeating an event on any combination of consecutive days. PT2724 will compensate for daylight savings time if desired. It automatically adjusts for leap year and individually selected holiday exceptions can be programmed to over-ride regularly scheduled events. Specifications: 12 to 24 volts AC or DC operation. Stand-by current: 10mA (relay off) 50mA for each channel (relay on). Two (2) form C relay contacts are rated 10 amp @120VAC/28VDC. Tandem relay mode - allows both channels to activate simultaneously for all events. EE-Prom program memory protected against power loss. Accurate crystal controlled clock. Momentary and/or latching events. 50 individually programmed daily/weekly events per channel. Block programming capacity can accommodate a total of 350 events per week per channel. Ten (10) programmable Holiday dates per channel. First man in option. Alphanumeric LCD display simplifies programming. Standard or Daylight Savings Time settings. Automatic compensation for leap year. Built-in charger for 12VDC sealed lead acid or gel type batteries (Max charge current 100mA). Lithium battery backup maintains clock (optional) (Altronix part # LB2032). User friendly programming. Board dimensions (approximate): 5.25 W x 3.5 L x 1.5 D Installation Instructions: 1. Mount PT2724A in desired location. Carefully Review: Basic Operation (pg. 2) Terminal Identification Table (pg. 2) Push Button Layout and Description (pg. 3) Programming Instructions (pgs. 4-7) 2. Connect 12 to 24 Volts AC or DC to terminals marked [+ DC -- / ~AC~]. (when using DC carefully observe polarity). 3. Connect 12VDC battery (optional) to terminals marked [+ BAT -- / 12VDC].

4. Insert lithium battery (optional/not included. Order part LB2032) in battery holder as shown in (Fig. 1, pg. 3) with the (+) positive side facing up. 5. Connect devices to be controlled to the dry relay outputs of either Channel A or Channel B. Note: It is important when connecting DC powered electromechanical devices such as Mag Locks, Electric Strikes, Bells, Relays, etc. to install a catch diode across the pos (+) and neg (-) terminals of the device. Connect diode as close to the device as possible with the banded side facing the pos (+) terminal. This will reduce the possibility of interference. 6. Program clock and desired event schedule (see Programming Instructions, pgs. 4-7). Basic Operation: PT2724 controls two independently operated dry form C relays. Relays can be programmed to: turn on (latch), turn off (release latch) or pulse (momentary toggle) at a specified time and day (this is referred to as an event). Events are programmed via the push buttons and LCD display. Events may be programmed to occur on any day of the week at any time. In addition, events may be programmed as a block event which repeat at a specific time on two (2) or more consecutive days (i.e. MO-FR, SU-TH, etc) Multiple combinations of individual and block events may be programmed. Holiday exceptions are individually selected by date and will over-ride all regularly scheduled events. The four (4) output relay modes consist of: Relay OFF - De-energizes the relay until a relay ON event is detected Relay ON - Energizes the relay until a relay OFF event is detected. Disable - Used to cancel an existing programmed event. Pulse - Momentarily energizes the relay for a selectable time period of 1 sec. to 15 secs. Time is displayed in 24 hr. military format. Terminal Identification Table: Terminal Legend NO, C, NC, CH A NO, C, NC, CH B Function/Description Dry Contact outputs used to switch controlled devices. When these relays are energized (ON) the NC and C terminals are open and the NO and C terminals are closed. When this relay is de-energized (Off) the NC and C terminals are closed and the NO and C terminals are open. + DC -- AC or DC Input 12 to 24 volt. When using DC carefully observe polarity. ~ AC ~ + BAT -- 12VDC stand-by battery input (battery leads provided). 12VDC FM When this terminal is connected to DC neg. (-) the First Man in feature is enabled. Both relays will remain in their present position until this connection is terminated. At that time relays will resume normal operation and latest scheduled events will occur. - 2 -

Fig. 1 NO C NC NO C NC SW2 RELAY ON SU 01:01 SW3 + DC --- AC + BAT --- 12VDC FM SET ENTER UP DWN 12-24 Volt AC/DC input 3V Lithium Battery Socket (Altronix part # LB2032) Push Button Layout: SET ENTER UP DWN Push Button Description Table: Push Button SET ENTER UP DWN Function/Description Scrolls thru program fields. Escapes out of existing programming. Accepts programmed data. Scrolls up through data selections. Scrolls down through data selections. UP and DOWN keys can be used to select data entries. After scrolling to the correct entry, depress accept. SW2 clip SW SW3 slide SW Selects tandem or individual relay operation. Selects channel to be programmed. - 3 -

Programming Instructions: The flashing cursor denotes location of data entry selection to be made. If an entry was made in error or requires changing, depress SET to backspace, make the correct selection and depress accept data and advance the cursor. A. Setting Clock/Calendar: Upon initial power up CH ON SU 01:01 SET TIME 01/01/01 SU/01:01 Enter the current date, day of week and time (military) by depressing UP and DWN to make the selection then depress accept. To program Daylight Savings Time (refer to Setting Block Events (weekly repeat) and Daylight Savings Time - section C 2, page 6) To change or program clock/calendar simply repeat the steps above. B. Setting Events and Adding Events: 1. Setting Events SET EVENT A01 OFF SU 00:00 Note: A01 indicates Channel A event 01. When cursor appears you are able to scroll through events. until the flashing cursor appears under OFF (relay function) position in display. Now select type of operation required, by scrolling using the UP and DWN push buttons until either: ON - Relay ON (latching mode). OFF - Relay OFF (latching mode). PL - Relay Pulse ( momentary). appears in display and depressing ENTER will make selection. When selecting the pulse mode PL01 will appear in the display. It is now necessary to assign the length of time (duration of relay activation). The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons, then depressing accept. - 4 -

Note: If pulse duration is not selected relay output defaults to 1 second. Next select the individual day of the week by scrolling using UP and DWN push buttons and depress accept. Next select the hour and minutes the event is to occur by scrolling using UP and DWN push buttons and depress accept. You may continue to program events by repeating the previous steps or exit programming by depressing SET. Note: When programming additional events it is necessary to select the next consecutive event number following the last event program to continue. Note: When it is required to have the same event repeated on two (2) or more consecutive days of the week, the event must be programmed as a block by selecting BK in the day field. A01 OFF BK 00:00 Note: To program the consecutive days of the week refer to Setting Block Event (weekly repeat) and Daylight Savings Time - section C1 below. 2. Adding Events SET EVENT A01 OFF SU 00:00, if the event is not programmed, the cursor will move to the OFF (relay function) position. If the event is programmed the cursor will move to the position and the programmed information of the event will be displayed. At this point depress the UP button to step up through the programmed events. When an unprogrammed event is reached the cursor will move to the OFF (relay function position). (At this point refer to setting events or setting holiday events.) C. Setting Block Events (weekly repeat) and Daylight Savings Time: SET BK A=SA/SU TIME=DS 1. Block Event Programming Flashing cursor will appear at the location of the first day of the week desired. Depress UP and DWN to select day. Depress confirm selection, then cursor will appear at the location of the last day of the week desired. Depress UP and DWN to select day. Depress confirm selection. - 5 -

1) Monday through Thursday depress MO followed by TH. 2) Wednesday through Sunday depress WE followed SU. 2. Daylight Savings Programming The cursor will appear under DS (auto clock adjust daylight savings mode) in display. To change mode depress UP or DWN once ST (clock does not adjust standard time mode) Depress accept correct selection. Note: Select DS for areas that observe daylight savings or ST for areas that don t observe daylight savings. D. Setting Holiday Events: (These events will occur on programmed Holiday Dates - see Setting Holiday Dates below). Find the first unprogrammed event (refer to Adding Events - section B2 page 6). until the flashing cursor appears under OFF (relay function) position in display. Now select type of operation required, by scrolling using the UP and DWN push buttons until either: ON - Relay ON (latching mode). OFF - Relay OFF (latching mode). PL - Relay Pulse ( momentary). appears in display and depressing ENTER will make selection. When selecting the pulse mode PL01 will appear in the display. It is now necessary to assign the length of time (duration of relay activation). The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons, then depressing accept. Note: If pulse duration is not selected relay output defaults to 1 second. Next select HL (holiday) and time (military) by scrolling using UP and DWN push buttons and depress accept. You may continue to program events by repeating the previous steps or exit programming by depressing SET. E. Setting Holiday Dates: It is now necessary to assign these holiday events specific calendar dates which they are to occur. SET HOL A01 HOL SU 00:00-6 -

Enter the holiday date, day of week and year by depressing UP and DWN to make the selection then depress accept. Note: Holiday events will override all regularly programmed events that occur on a particular holiday date. F. Delete/Disable Events or Edit Events: Previously programmed regularly scheduled and/or holiday events may be deleted/ disabled without having to erase all events. SET EVENT A01 ON TU 00:00 Now scroll using UP and DWN push buttons to the event you wish to delete, depress move flashing cursor under relay option then depress UP and DWN push buttons until DIS is displayed, depress confirm. G. Delete All Events: This will delete all previously programmed events. CLR MEM CLEAR MEMORY? PRESS UP & ACCEPT Depressing UP push button will now clear all events previously programmed. If you wish to escape from this selection depress any of the other push buttons: SET, ENTER and DWN. H. Tandem Relay Mode: To operate in the Tandem Relay Mode, close switch SW2. This mode setting will allow events programmed for Channel A and Channel B to operate both relays simultaneously (1 DPDT relay output). This setting doubles the amount of programmable events. Note: When using the Tandem Relay mode, sequential ON/Off or OFF/ON events must be programmed in the same channel. (If there is a Channel Program conflict, such as CH A is set to ON and Channel B is set to OFF. The ON command will override the OFF and both relays will remain ON. - 7 -

Customer Event Log Event # Relay # Day/Block Holiday Dates Event Type Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIPT2724 Rev. 110205 K02E MEMBER - 8 -