High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Similar documents
Connectix Cabling Systems

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Mar11 Rev E

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

PREMIUM 5e F/UTP PRODUCTS

Follow The Leader In Shielded Technology

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

PATCH CORDS, PLUGS & CABLES

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

3M 8900 Single-mode SC Crimplok Connector

SMART CLASSix 24/48 UTP Patch Panels -

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Clarity Advanced Solutions6A

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SECTION 4 TABLE OF CONTENTS

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

ULTRA HIGH DENSITY SOLUTION GUIDE

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

Compact Module. Category 6 FTP Cabling System

HI-DEX PRODUCT SET DATASHEET

2-Port Hub Type 1 2-Port Hub Type 3 Unshielded 2-Port Hub Type 3 Shielded

CAT6Plus System. Brand-Rex Limited

Optimax Field Installable Connectors and Installation Tool Kits

SC Connector. Fiber Optic Connectors. MDR Electronics

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

STRUCTURED CABLING SYSTEMS (SCS)

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

CATEGORY 5e CABLING SOLUTIONS

Enterprise Networks. Comms Room and Backbone. in DETAIL

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

LONWORKS Fibre Optic Router

CATEGORY 6 CABLING SOLUTIONS

Belden IBDN System 10GX Enabling Technologies

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

Fibre optic router for TP/FT-10 LRW-112PP

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Copper Solution Contents Cabinets Fiber Optic Solution

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

SC Type Fiber Optic Connectors

QUEST C6 SOLUTIONS CAT 6 CONNECTIVITY PRODUCTS LAN CONNECTIVITY

onlinecomponents.com

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

ODW-621. RS-232 Point-to-point applications

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

For latest revision, visit our website at For Regional Customer Service, visit our website at

Belden IBDN System 10GX The next level of cabling performance

PRODUCT NUMBER: TMS-E1EH8-X61xx. Specification. 48Gbit/s Mini SAS HD. Active Optical Cable. Ordering Information

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

HARTING Ethernet cabling cables and connectors, 4 wire

FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits

SPECIFICATION. Spec No : VSS-1402-CS603B

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Cable matrix. strong in connectivity

T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic

FIBER OPTIC A/B SWITCH (Non-latching)

LONWORKS Fibre Optic Converter

Enterprise Solutions Catalog 2007/8

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

3A+G Technology & Turnkey Production Solution XFS COMMUNICATIONS, INC.

European Product Catalog2009 AMP NETCONNECT Building Networks

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

USB-0100TX USB Fast Ethernet Converter. User s Guide

DINTEK LAN Cabling Systems

about dktcomega DKTCOMEGA s mission

Keyed LC Connector Solution A LANscape Solutions Product

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

E3/DS3 Fibre Extender

DESIGN!!GUIDELINES!!!!!

LCS2 Cat. 6 RJ 45 Patch panels and units

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Cat.6 4 Pair UTP Cable

Model FS-4608R. Features. Overview

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

Category 6 Solutions

Non Magnetic Connectors Product Catalog

Cabling Systems for Data Centers

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Transcription:

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring John L. Hill AMP Incorporated July, 1998

High Performance Cable Assembly Characteristics Controlled/Matched Impedance Connectors and Cables High Speed Signals Data Rates of 0.5 to 1.0625 to 2.125 to? Gigabits per second Sub-nanosecond risetimes Low Skew Cable Low Crosstalk Fully Shielded for Emissions Control

High Performance Cable Assemblies Examples HSSDC (High Speed Serial Data Connector) DB9 IEEE 1394 High Performance Serial Bus Applications for High Performance Cable Assemblies Fibre Channel Serial Storage Architecture (SSA) Gigabit Ethernet

High Speed Serial Data Connector

Standards Already Including HSSDC X3T11 (FC-PH3) Approved X3T10.1 (SSA-PH2) Approved IEEE 802.3z Approved

HSSDC Available Products Cable Assemblies Low Skew Shielded Quad Cable (#22, #24, #28, #30 AWG) Equalized for long lengths Fully shielded, overmolded cable plugs Board Mount Receptacles Right Angle Surface Mount Straddle Mount Single & Dual Port Bulkhead Brackets

HSSDC Applications Fibre Channel, SSA, Gigabit Ethernet and Token Ring» Multi-user, mass storage retrieval» Video editing and video on demand» Data and design centers Storage, Servers, Workstations Hubs, Routers, Switches Host Bus Adapter and Network Interface Cards

MT-RJ Connector for 100Mbps Token Ring Ken Hall, RCDD LAN Specialist AMP Incorporated July 1998 1 075-

Why the MT-RJ? It is the best choice 2-fiber Connector Plug / Jack Design Snag-proof Plug Latch Design Drop-in Replacement for Copper Connectors Designed With Transceiver Manufacturers Half the port density of current connectors: ST & SC Growing Support by Network OEMs Singlemode & Multimode Capable 2 075-

Designed from the Outset as a True System Commercially Available Fiber Cable To Transceiver on Hub 3 On board Commercially Available Fiber Cable 075-

MT-RJ Multi-Source Team Fujikura Ltd. 4 075-

Low Complexity: Ease of Field Installation of MT-RJ No-Polish - No Epoxy Termination Reduced number of Tools - No special tooling No Excess Length Required at outlet or patch panel Ease of Field Testing Attenuation is easy Return Loss Field Verification is unnecessary. 5 075-

568SC: Duplex Plug-Adapter-Plug Interface. Specialized cut-outs Depth to cable transition = 1.95 Surface Mounted interface MT-RJ Plug / Jack Drop-In replacement for existing 8- position modular connectors Depth to cable transition =.926 Fits INTO J-Box Snagless Plug Design 6 075-

Field Installation - Bag of Parts Disposable Tool Dust Plug 1 Piece Polish-Free, Epoxyless Jack 7 075-

LAN Electronic MT-RJ Supporters Also Released lines: Bay Networks Transition Networks Others Releasing @ InterOp 8 075-

LAN Electronic MT-RJ Supporters "MTRJ transceivers are essential to delivering the power of Gigabit networking to next generation LAN backbones. Only through high density FDDI and Fast Ethernet connections can gigabits of data, voice and video reach users cost effectively." Bob Peyser, Director Product Management 9 075-

Multimode Performance: Factory Test Requirements: <0.75 db attenuation < -20 db return loss <0.3 db change Temp Life, Humidity & Low Temp <0.5 db change Cable Retention 10 Test Max Delta Change Final Measurement FOTP-171 Method B1 Insertion Loss N/A 0.11 db typ 0.19 db max FOTP 107 Return Loss N/A -42.5 db typ -36.3 db min FOTP-2 Impact 8 drops / 1.5 m N/A 0.14 db IL -41.3 db RL FOTP-1 Flex 0.5 kg N/A 0.18 db IL -41.3 db RL FOTP-36 Twist 15 N at 0 º N/A 0.20 db IL -41.2 db Rl FOTP-6 Cable Retention 66 N at 0 º 0.06 db 0.20 db IL -41.2 db RL FOTP-6 Cable Retention 19.4 N at 90 º 0.06 db 0.19 db IL -41.2 db RL FOTP-185 Coupling Mech 33 N at 0 º N/A 0.13 db IL -41.5 db RL FOTP-21 Durability 500 cycles NA 0.11 db IL -36.3 db RL FOTP-4 Temp Life 60ºC/14 days 0.01 db 0.08 db IL -39.0 db RL FOTP-5 Humidity 4 days @ 95% 0.15 db.09 db IL -38.9 db RL FOTP-188 Low Temperature -10 ºC/4 days 0.22 db 0.13 db IL -42.3 db RL 075-

Singlemode Performance: Factory Test Requirements: <0.75 db attenuation < -26 db return loss <0.3 db change Temp Life, Humidity & Low Temp <0.5 db change Cable Retention 11 Test Max Delta Change Final Measurements FOTP-171 Method B1 Insertion Loss N/A 0.24 db typ 0.52 db max FOTP 107 Return Loss N/A -44.4 db typ - 36.2 db min FOTP-2 Impact 8 drops/1.5 m N/A 0.38 db IL -40.6 db RL FOTP-1 Flex 0.5 kg N/A 0.40 db IL -40.1 db RL FOTP-36 Twist 15 N at 0 degrees N/A 0.37 db IL -40.2 db RL FOTP-6 Cable Retention 66 N at 0 º 0.20 db 0.39 db IL -42.3 db RL FOTP-6 Cable Retention 19.4 N at 90º 0.11 db 0.34 db IL -43.2 db RL FOTP-185 Coupling Mech 33 N at 0 º N/A 0.37 db IL -45.0 db RL FOTP-21 Durability 500 cycles N/A 0.35 db IL -40.5 db IL FOTP-4 Temp Life 60 ºC/14 days 0.24 db 0.29 db IL -44.2 db RL FOTP-5 Humidity 4 days @ 95% 0.10 db 0.30 db IL -43.9 db RL FOTP-188 Low Temperature -10 degrees C 0.18 db 0.29 db IL -44.1 db RL 075-

Susquehanna Pfaltzgraff Horizontal MM Installation The MT-RJ gave us the capability to utilize the existing cable plant and organize the copper and fiber at the faceplate. This connector technology is a vast improvement over the ST and SC connectors as it brings fiber optics into the same base system as our existing copper without having to specially adapt to the connector interface Clair Bang - Director MIS 12 Installation consisted of: At wall outlets: 3 Category 5, 1 pair fiber 24 MT-RJ duplex jacks 24 MT-RJ - ST 3m cords Field terminations performed by: KBK Communications In Equipment Room: 1 24-port MT-RJ patch panel 24 MT-RJ to ST 7m cords 075-

Penn National Insurance Backbone Installation The backward compatibility to copper will provide us the ability to save space both in the equipment room and at the desk in the future. After a short training review, my staff and I got involved in the installation of the connector and termination of the fiber. I was impressed with the ease of termination for the installation.... the termination of the MT-RJ is a method that we can easily use inhouse for our own maintenance and installations 13 Dan Morrison, Director MIS Installation consisted of: Main Equipment Room to TC - separate floor 1 24-port (48 fiber) 1u high patch panel per cross-connect Standard tight buffered cable 48 MT-RJ - ST 7m cords Field terminations performed by: Penn National Employees 075-

Performance: Field-Installed Testing ANSI/EIA/TIA-526-14-A Method B procedure. Attenuation Channel: Requirement <2.0 db Penn National.1.25 db typ/1.72 db max Pfaltzgraff.1.15 db typ/1.81 db max Connector Return Loss: Requirement <-20 db Penn National.-44.6 db typ/-43.7 db max Pfaltzgraff...-43.9 db typ/-42.1 db max 14 075-

Suppliers and Manufacturers of MT-RJ Based Products: 15 Mini-MT Ferrules Fujikura Furakawa Sumitomo USConec EurOptics AMP Siecor MT-RJ Transceivers: HP AMP Lytel Fujikura Sumitomo Siemens AG MT-RJ Connectors: AMP + 9 Licensees Globally Siecor Fujikura 075-

Intermateability Specs 16 MT Ferrule Intermateability IEC 1754-5 MT Interface 11/96 IEC 1754-7 MPO Interface 11/96 Mini-MT Intermateability IEC NWIP submitted 3/97 TIA FOCIS for Mini-MT submitted 1/97 MT-RJ Intermateability (TIA- FOCIS-12) PN 4172 work item approved - Jan 98 Draft document to be submitted to chairman - Apr 98 Letter ballot to be distributed to committee - May 98 Comments to be discussed - Jun 98 MT-RJ Team actively involved with TIA and IEC MT-RJ Team committed to rigorously and completely defining interface. 075-

MT-RJ Meets or exceeds all Testing Standards Multi-Level Multi-source Ferrules Transceivers Connectors Cable Assemblies Network Electronics Interface is familiar to end-users Backward compatible to copper-based connecting hardware Application-Independent, creating migration path to 100Mbps and 1Gbps Token Ring from existing platforms 17 075-