Operating Manual for Clock / Auxiliary Displays for VHX systems

Similar documents
USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

UC1000 Universal Controller

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

SC-C1M SiriusConnect TM Vehicle Tuner

Home Roam TV Basic User Manual

minihomer TM User s Guide

MLA-XLR MIDI Line Amplifier

CABLE TESTER User Manual

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

Home Kit. Model XM101HK

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

LF-IRX. 12 Month Limited Warranty LF-IRX. Remote Control Extender. Owner s manual. For customer service and technical information::

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

AS Telecommunication Watch Dog. Version 2.70

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

MaxView Cinema Kit Quick Install Guide

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

INSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator

INSTRUCTION BOOK FOR. Special Needs Lecterns

Z100 / Z300 Z500 Z700 OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW ELLIPTICAL!

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Introduction. Package Contents. Installation Requirements

Instruction Guide. The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB. The Professionals Source For Hard-to-Find Computer Parts

FRQM-2 Frequency Counter & RF Multimeter

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

Designed in Colorado, USA. Bluetooth Cable. Quick Start Guide

Troubleshooting CS800/LC900 Bikes

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Installation & User s Manual

LIGHT COPILOT II. elationlighting.com Internet:

WaveRider Trouble Shooting Guide

NT-9600 Wireless Barcode Scanner. Introduction

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Introduction 2. Installation 3. Suggested Configuration 4. Using the Remote 5. Adjustment Mode 6. Technical Specifications 7. Technical Support 8

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

Optical Mobile Mouse. User s Manual

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

In-Wall Control Mount for ipod Touch

Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact us. This manual may contain technical or

By CHANNEL VISION. Flush Mount Amplifier A0350

ZIG-POEPRO-70A. HDBaseT HDMI Extender

AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T

INSTRUCTION BOOK FOR. Lectern

INSTRUCTION BOOK FOR. Lectern

For warranty service, please contact Microframe at: A technician will gladly assist you.

US Rev. E, Copyright 1 September 2008 CAUTION:

Table of contents. Opening the Overhead Monitor... 4 Precautions Care And Maintenance... 5 Operating OHM102/153 Monitor...

WCM-758G. user MANUAL

FDTV2A Owner s Manual

instruction manual x-y indicator model 620D

FDTV1a Owner s Manual

User Guide. 20 Widescreen LED Monitor NS-20EM50A13

AUDIO WIRELESS. with IR Extender Feature OWNER S MANUAL SENDER T CAT. NO

NS-3 RF Noise Source Operation Manual

Utility Amplifier GA6A Model

Thermo-Simple 1 version 2 (TS.1 ver.2) 2013

Table of Contents. Introduction...1

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

User Manual. VGA and Audio Cat-X AV Extender V1.0 AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR

Omnidirectional TV/FM Antenna

instruction manual model 315 video sync separator s/n

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

instruction manual video cross hair generator/converter model VC619

MAN FDAIP-CVH VER HDSDI

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

ES-450J2 Universal 2 Channel Jog/Shuttle Remote

2 Verify that the green light

AUDI WITH MMI A4/A5/A6/A8/Q7. -. Product Code : A4L

TALKBACK INTERCOM SYSTEM VC-2927 CLOCK CONTROL CARD FOR THE VC-24

Sport-TIMER 3000 TM Instruction Manual

Z100 / Z300 Z500 Z700 OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW ELLIPTICAL!

Viztrac AM200 User s Guide. Page 1 of 12

ZIG-POC-100. HDBaseT HDMI Extender

ALPHA Personal Priority Display User Manual

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

CT Series. Terminal User s Guide. Model CT74

FD104CV. Installation and Operation Manual 10.4 LCD. Revision Date: 08/01/2017 Page 1 of 14. Rev: G. Document Number: MAN FD104CV

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

FIELDVISION OCM-7B-4KV2 7 4K IPS Monitor USER MANUAL

ICS-75. Integrated Combiner Shelf Installation and Operation Manual Part Number MN/ICS75.IOM Revision 5

DVI Over Cat5 2x2 Matrix Switch. Model: B

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

USER MANUAL Model: A5

ST-4000 SIGNAL LEVEL METER

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

SXT SXGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

LBS-1 (Lowrance Broadband Sounder)

APSPB PUSH BUTTON ZERO Installation Manual

Instruction Manual. 7" Wireless Camera System with Wired Side Camera Inputs RVS-355W. Reverse With Confidence 1

Satellite Radio. Expand Your Factory Radio ISSR bit & 29-bit LAN. Owner s Manual Gateway. add. Harness Connection USB. Port 1 Port.

LE062XF DCC Decoder for Atlas N Scale Locomotives

instruction manual Model 619D video dual cross hair generator s/n

Master Clock Controller. User Guide. pyramidtimesystems.com

Transcription:

Operating Manual for Clock / Auxiliary Displays for VHX systems The VHX auxiliary display module is designed to work with a Dakota Digital VHX system and will not function properly on its own. With this module, an additional display area is added to your current system to provide more functionality. This module can be used as a simple clock display or it can display data from any BIM module attached to the system as well as several gauge values from the control box sensors. Most versions of this module come with at least one switch in the face to allow the display to change between various screens. Some versions may also contain two additional switches in the face which can be used as the SW1 and SW2 for the VHX control box with the use of the switch harness provided with it. CONNECTION: The auxiliary display has a connector on the rear that will accept a normal CAT 5, CAT 5E, or CAT 6 patch cable. This can be used to connect the module to any available port on the VHX control box (same locations the main VHX gauges plug into). Auxiliary Display module Use any open jack OR Connection for all auxiliary displays Used for displays with 3 switches VHX control box DISPLAY CABLE AUX. I/O VHX CONTROL BOX www.dakotadigital.com techsupport@dakotadigital.com 605-332-6513 FUEL - FUEL SND FUEL + OIL - OIL SND OIL + WTR - WTR SND ADJ - ADJ SND SW1 (-) SW2 (-) SPD OUT DIM (+) SPD - CHECK ENG (-) SPD SND BRAKE (-) SPD + HIGH (+) LEFT (+) WARN RIGHT (+) TACH 4x4 (-) ACC. POWER GEAR (1 WIRE) CONST. POWER WAIT (+) GROUND CRUISE (-) ORANGE GREEN SWITCH HARNESS: Some auxiliary modules will come with the pictured switch harness to allow additional switches in the clock face to function as switch 1 and 2 for the main VHX system. ORANGE (switch 1) GREEN (switch 2) BLUE (switch 3) Auxiliary modules with 3 switches on front: Connect the orange wire to SW1(-) terminal on VHX control box. Right switch will be SW1 (speed display). Connect the green wire to SW2(-) terminal on VHX control box. Left switch will be SW2 (tach display). Leave blue wire unconnected. Center switch will be SW3 (clock display) Auxiliary modules with no switches on front: If the module has no switches, connect an external switch from the blue wire of the harness to ground to allow switch operations for the clock display. The orange and green wires would be left unconnected in this case. 1 MAN #650360

SETUP: To enter setup, press and hold the switch (for systems with 3 switches, hold the center switch) while turning on the key. The display will read SETUP. Release the switch and the setup menu will be entered. Below is an outline of the setup options. Following the outline are more detailed instructions for each option. Press and release the switch to move through the various setup options or to change a setting. Press and hold the switch to select a setup option or to save a changed setting. SETUP CONTRAST VERSION UPDATE SPD SLOW MED FAST TEMP UNIT F or C SCREENS SET DEFAULTS DONE Allows adjustment of LCD contrast. Displays software version Sets update speed of fast changing displayed data (such as tachometer) Slowest update speed of data Medium update speed Fastest update speed Selects unit used for temperature displays Fahrenheit or Celsius Allows turning different display screens on or off Sets all the settings back to factory default values Leaves setup and returns to normal operation. CONTRAST: This option allows adjustment of the display contrast to best suit the particular mounting location in your vehicle. Press and release switch until CONTRAST is displayed, then press and hold switch CONTRAST will display with a contrast bar below it. Press and hold the switch to increase the contrast. Release the switch and press and hold again to reduce the contrast. Each time the switch is release the direction of contrast adjustment will change. Once contrast is set stop pressing the switch. After about 5 seconds without a switch press the contrast setting will be saved and setup will return to the main menu. VERSION: This option will display the version of the software in the display module. This information may be needed if you are calling for technical assistance. Press and release switch until VERSION is displayed, then press and hold switch. The software version will be displayed (example: VER VC01). Press and release switch to return to main menu. UPDATE SPD: This option sets the fastest update speed of screens. The effect will be most noticed when the tachometer screen is displayed. The fastest setting will allow frequent updates so the reading is more accurate at any given time. Fast changing readings may be difficult to read or distracting so some customers prefer to read a slower averaged reading which is available in the MED or SLOW setting. Default setting is MED. Press and release switch until UPDATE SPD is displayed, then press and hold switch. Press and release switch to toggle through speed settings. Press and hold switch when desired setting is displayed to save setting. DONE will be displayed. Release switch to return to main menu. 2 MAN #650360

TEMP UNIT: This setting determines which temperature unit is used when displaying temperatures. This unit setting will be independent of the units used in the main VHX system and may be used to provide and alternate display unit from the main VHX screens if so desired. Default setting is Fahrenheit. Press and release switch until TEMP UNIT is displayed, then press and hold switch. Press and release switch to toggle between F (Fahrenheit) and C (Celsius) Press and hold switch to select displayed setting. DONE will be displayed. Release switch to return to main menu. SCREENS: This option allows customization of the displayed values. You may independently select any screens you wish to be ON or OFF during normal operation. If a screen is set to ON, it will be included in the sequence of screens displayed when you press the switch in normal operation. If a screen is set to OFF this screen will be skipped over when you move through the screens. This is helpful for reducing the number of screens you must scroll through in normal operation by preventing the display of screens that you don t want to see or that are already set to display in the main VHX system screens. Press and release switch until SCREENS is displayed, then press and hold switch. Press and release switch to move through available screens. Press and hold switch to toggle screen setting between ON and OFF Once screens are set as desired, press and release switch until SCREENS DONE is displayed. Then press and hold the switch to save the changes to screen setup. If the key is turned off before SCREENS DONE is selected, the new screen settings will not be saved. NOTE: If all screens with displayable data are set to OFF, a message will appear during normal operation stating that no data is available for current screens and that more screens should be turned on. In this case, go to the screens option and turn on more screens to prevent this message. SET DEFAULTS: This option allows all the settings to be returned back to the factory defaults. This may be helpful to get back to a known starting place with the settings. This may also be a step in troubleshooting issues so the technician will have consistent settings to work from. NOTE: This option will reset all settings to factory defaults, including the contrast setting and it will also zero any clock offset that may be set. Press and release switch until DEFAULT is displayed, then press and hold switch. Display will read RESET TO DEFAULTS? N Press and release switch so display reads RESET TO DEFAULTS?.Y Press and hold switch to reset defaults. DONE will be displayed. Release switch to return to main menu. DONE: This option will leave setup and return to normal operation. Alternatively, the key may be turned off at any point in the main menu of setup and settings will be saved. If key is turned off while setting an option, the new settings may not be saved. Press and hold switch when SETUP DONE is displayed. DONE will display in large font. Release switch to leave setup and return to normal operation. NORMAL OPERATION: In its normal operation, this auxiliary display module provides an additional display to your main VHX system. This display can display a clock, several of the main system gauge values and data from any connected BIM expansion unit. This section describes how to operate this display module in its normal operating mode. BACKLIGHTING / DIMMING: The backlighting and dimming for the display are controlled by the main VHX system. Use the main system setup to make changes to the backlighting and dimming behavior. 3 MAN #650360

AVAILABLE SCREENS: Some screen data should always be available to this module from most VHX systems. These screens are: Clock Engine Temp Oil Pressure Fuel Level Tachometer Speed (MPH) Speed (km/hr) Additionally, depending on the configuration of your main VHX system, many other screens may also be available (many of these readings require additional sensors and or BIM expansion modules) including: Gear Position Compass Various temperature readings Various pressure readings More readings may be available from BIM modules By default all screens are set to ON but only screens with data available will be displayed. WARNING POINTS: Warnings for the main system values (Engine Temp, Oil Pressure, Fuel, and Tachometer) will not be displayed in this auxiliary module as they are provided on the main VHX system. However, BIM modules that have the internal warning points (set in VHX main system setup) will flash if they are currently being displayed and they are in a warning condition. CHANGING SCREENS: Various screens of information are available to the auxiliary display from the VHX system. To display a different screen simply press and release the switch. The display will change to the next screen selected in the SCREENS list in setup that has data available. Screens that are set to OFF in setup or that don t currently have data available will be skipped. NOTE: All the information displayed on this module comes from the main VHX system. If the information needed for a particular screen is not provided by the system (a BIM module becomes disconnected for instance) the display may show??? to indicate information is no longer available for that screen. Pressing the switch will move the screen to next available screen with available data. SCREEN SPECIAL FUNCTIONS: Some screens have additional special functions. To use these special functions press and hold the switch. One screen that has a special function is the clock screen. Holding the switch on the clock screen allows setting the clock offset (see CLOCK section for details). Additional special functions for BIM modules, if any, are described in the BIM module manual. CLOCK: CLOCK SOURCE AND SETTING CLOCK: This auxiliary module does not keep its own time. Instead it uses either the VHX system time or the time from a BIM-16 clock module (if connected). For most applications, it is recommended to set the clock on the VHX system or set the BIM-16 time if it is being used. NOTE: Due to system limitations, if all 16 BIM expansion channels of the VHX system are in use and none of them provide time information (such as BIM-16) a clock reading may not be available to display on this module. 24 HOUR CLOCK: The main VHX system clock is only a 12hr clock. If a 24 hour clock display is desired, a BIM-16 clock expansion module may be purchased from Dakota Digital. This module will connect to the BIM expansion jack of the VHX control box and can be set in the main system setup. If a BIM-16 is connected to the VHX system, this auxiliary display module will automatically read clock data from the BIM-16. NOTE: If the clock offset is used with a 24 hour clock source, the displayed time will be forced to a 12 hour clock. 4 MAN #650360

USING CLOCK OFFSET: Because this auxiliary module displays the clock, it may be desired to disable the display of the clock on the main VHX screens. This makes it much more difficult to adjust the VHX clock because the main VHX system requires the clock screen to be displayed to set it. To make clock adjustment more convenient in this situation, a clock offset may be set on this module. The steps are the same as setting the main VHX clock but it is done using the switch for this auxiliary module instead. It is important to note that the VHX time is not changed with this method. Instead a time offset from the main system time is set. If the main VHX clock display is enabled, this method will cause this time to be different than that displayed in the VHX system displays. With the clock screen displayed, press and hold the switch. The hour will begin to flash. Press and release the switch to adjust the hours. Press and hold the switch to move to tens of minutes. Tens of minutes will begin flashing. Press and release the switch to adjust the tens of minutes. Press and hold the switch to move to the single minutes. Single minutes will begin flashing. Press and release the switch to adjust the single minutes. Press and hold the switch to apply the offset and return to normal display. NOTE: If the VHX system clock time or the BIM-16 clock time is adjusted, the auxiliary module clock offset will automatically be reset to zero so the time displays are resynchronized. Troubleshooting guide. Problem Possible cause Solution Display reads NO DATA FROM CONTROL CHECK CONNECTIONS AND FOR BROKEN WIRES Patch cable not fully plugged into module or VHX control box. BIM module cable not fully plugged into a BIM module. Ensure to push the cable into the connector until the cable clicks into place. If the tab on the cable appears damaged a new CAT 5, 5E, or CAT 6 PATCH cable should be used. Push all BIM module cables firmly into the jack to make sure they are fully seated. Display randomly moves through screens and repeatedly displays DAKOTA DIGITAL Display is very dark or light and difficult to read Can t display desired screen Display reads NO DATA AVAILABLE FOR CURRENT SCREENS TURN MORE SCREENS ON Screen displays??? instead of a reading Auxiliary module doesn t light up or display anything System no longer displays clock Or Clock displays??:?? VHX display cable or BIM module cable is broken or pinched. Auxiliary module received no data at startup and has reverted to a DEMO mode. VHX system is in demo mode Contrast needs to be adjusted Screen is turned off in screen setup Data is not available for display All screens that have available data are set to OFF in setup Data for that screen is no longer available. Such as BIM module losing power or connection to system. A BIM channel may also have been changed or over crowded. Unit not connected to main VHX system. 16 BIM channels in use. BIM module channels have been changed Inspect all cables for nicks or cuts or for wear marks or pinched locations. Replace questionable / damaged cables. Reroute cables away from harm. Turn key off to stop demo mode and see Display reads NO DATA FROM CONTROL CHECK CONNECTIONS AND FOR BROKEN WIRES for solutions to the no data problem. This module will enter demo mode if the VHX system is in demo mode. See SETUP section for instructions on adjusting the screen contrast. Follow steps under SCREENS in setup section to verify setting If screen is from a BIM module, ensure it is connected and functioning properly and that no other BIM modules are set to use the same channel. Follow steps under SCREENS in setup section to turn on one or more screens to display. If the screen selected is a reading from a BIM module, check that the BIM module is connected and functioning properly. If the channel of the BIM has been changed, turn the key off and then back on so the VHX system can search for the correct channel. Also verify that the new channel isn t already used by another BIM unit. Ensure that a patch cable is connecting the jack of the auxiliary unit to one of the display jacks on the VHX control box. If all 16 BIM channels are in use, there is no longer time to send clock data out. To get clock data back, at least one BIM channel must be left open or be a BIM-16 clock module. Turn the key off then back on to allow the VHX system to relearn the new BIM channel locations. 5 MAN #650360

SERVICE AND REPAIR DAKOTA DIGITAL offers complete service and repair of its product line. In addition, technical consultation is available to help you work through any questions or problems you may be having installing one of our products. Please read through the Troubleshooting Guide. There, you will find the solution to most problems. Should you ever need to send the unit back for repairs, please call our technical support line, (605) 332-6513, to request a Return Merchandise Authorization number. Package the product in a good quality box along with plenty of packing material. Ship the product by UPS or insured Parcel Post. Be sure to include the RMA number on the package, and include a complete description of the problem with RMA number, your full name and address (street address preferred), and a telephone number where you can be reached during the day. Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase. Send no money. We will bill you after repair. Dakota Digital Limited Lifetime Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it, under normal use and condition, be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in, such defect(s) will be repaired or replaced at Dakota Digital s option. This warranty does not cover nor extend to damage to the vehicle s systems, and does not cover removal or reinstallation of the product. This Warranty does not apply to any product or part thereof which in the opinion of the Company has been damaged through alteration, improper installation, mishandling, misuse, neglect, or accident. This Warranty is in lieu of all other expressed warranties or liabilities. Any implied warranties, including any implied warranty of merchantability, shall be limited to the duration of this written warranty. No person or representative is authorized to assume, for Dakota Digital, any liability other than expressed herein in connection with the sale of this product. 6 MAN #650360