How to set out a survey grid

Similar documents
RM15 Resistivity Meter

Tutorial: Measuring a Scene

GEM Systems Magnetism Survey Tutorial Colton Dudley

Practice, Practice, Practice Using Prototek Digital Receivers

MATRIX PANEL 3 WW DMX CONTROL TABLE

DW Consulting B.V. Preliminary Draft For Customer Approval

SCANNER TUNING TUTORIAL Author: Adam Burns

Overview. Teacher s Manual and reproductions of student worksheets to support the following lesson objective:

FUNDAMENTAL MANUFACTURING PROCESSES Computer Numerical Control

THE OPERATION OF A CATHODE RAY TUBE

Workshop: The art of making Little Books

Characterization and improvement of unpatterned wafer defect review on SEMs

jamaseis Guide for Displaying Seismic Data

5.2.3 Fibre Optic Rod 1 PARTNERS: Purpose: To replicate how light behaves in fibre optic cables by using a laser light and a solid acrylic rod.

THE OPERATION OF A CATHODE RAY TUBE

Identification - electrical services

The information being presented is intended for education

MODFLOW - Grid Approach

PS User Guide Series Seismic-Data Display

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes

Setting up the communication between a Total Station and SiteMaster range of products

Import and quantification of a micro titer plate image

Here s a question for you: What happens if we try to go the other way? For instance:

Aluminum spun system one piece reflector Parabolik Prime Focus AZ/EL or Polar Mount Easy Installation

Movement Caliber Cal.5030D

Stage Management Resource Sheet #2 Scoring Guide Page 1

Advanced Photon Source - Upgrades and Improvements

DSO138mini Troubleshooting Guide

INSTALATION PROCEDURE

MAX-MIN HLEM Survey Over the CASCADEN NORTH PROPERTY Ermatinger and Cascaden Townships, Ontario

LP- V SERIES LP- W SERIES

AUTO DOPPLER Owner s Manual

414D/419D/424D. Users Manual. Laser Distance Meter

Instruction Manual. Electronic Level - Inclinometer Model No

Analysis of WFS Measurements from first half of 2004

414D, 419D, 424D. Laser Distance Meter. Users Manual

Key Maths Facts to Memorise Question and Answer

PSC300 Operation Manual

INSTRUMENT CATHODE-RAY TUBE

HQ Electromagnetic Channel Locks. For the HQ Infinity

AMEK SYSTEM 9098 DUAL MIC AMPLIFIER (DMA) by RUPERT NEVE the Designer

K Service Source. Apple High-Res Monochrome Monitor

Cave Survey Using Tape / Disto and Instruments

E X P E R I M E N T 1

Software Package WW 9038 for the Sound Intensity Analysing System Type 3360 or the Digital Frequency Analyzer Type 2131

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

Dektak Step by Step Instructions:

+ b ] and um we kept going like I think I got

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

Dektak II SOP Revision 1 05/30/12 Page 1 of 5. NRF Dektak II SOP

CS2401-COMPUTER GRAPHICS QUESTION BANK

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

DH551C/DH550C/DL550C Double Sided Display User Manual

TeeJay Publishers. Curriculum for Excellence. Course Planner - Level 1

The following standards are embedded throughout the year and are present in all units applicable:

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Measuring Systems Hilti. Outperform. Outlast.

Arkansas. the natural state. Style Guide

7thSense Design Delta Media Server

G-700LITELite multiple Channel warping processor

MITOCW big_picture_integrals_512kb-mp4

Part 1: Introduction to Computer Graphics

Section 2.1 How Do We Measure Speed?

Linkage 3.6. User s Guide

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

2016 Excellence in Mathematics Contest Team Project Level I (Precalculus and above) School Name: Group Members:

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04

Movement Caliber Cal.Z60

Supplementary Course Notes: Continuous vs. Discrete (Analog vs. Digital) Representation of Information

MestReNova Manual for Chem 201/202. October, 2015.

Lesson 10 Manual Revision BIOPAC Systems, Inc.

Proceedings of the Third International DERIVE/TI-92 Conference

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis

User Manual. Applications. See for more detailed information. Manual Version: Software Version: 2.03.

Objectives: Topics covered: Basic terminology Important Definitions Display Processor Raster and Vector Graphics Coordinate Systems Graphics Standards

Version : 27 June General Certificate of Secondary Education June Foundation Unit 1. Final. Mark Scheme

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

PaPiRus Assembly Tips And Gotchas

Environmental Controls Laboratory

Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form

Sony 1270Q Setup and Operation Manual

Characterization of Diamond Samples CHESS Run Summer 2013

MODEL... MXL012/55NZ MXL012/65NZ SIMPLICITY AT IT S BEST SET UP & USER MANUAL REGISTERED COMMUNITY DESIGN NO

The Complete Guide to Music Technology using Cubase Sample Chapter

ENGIN 100: Music Signal Processing. PROJECT #1: Tone Synthesizer/Transcriber

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

WaterVue TV Installation & User Manual

PGDBA 2017 INSTRUCTIONS FOR WRITTEN TEST

ipad mini 4 LTE Right Cellular Antenna Replacement

TOMELLERI ENGINEERING MEASURING SYSTEMS. TUBO Version 7.2 Software Manual rev.0

CHAPTER 7 BASIC GRAPHICS, EVENTS AND GLOBAL DATA

2.1. Log on to the TUMI system (you cannot proceed further until this is done).

R&D White Paper WHP 085. The Rel : a perception-based measure of resolution. Research & Development BRITISH BROADCASTING CORPORATION.

MITOCW ocw f08-lec19_300k

CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

ENGR 40M Project 3a: Building an LED Cube

User Manual. TheKid CG. Professional Character Generator

GESTALT PSYCHOLOGY AND OPTICAL ART

THE INDIAN KEYBOARD. Gjalt Wijmenga

l a s e r S c a n n i n g

Transcription:

How to set out a survey grid Why? Covering a site with a regular grid of squares allows you to quickly establish rough or precise positions within the site. It is the standard form of position control used in fieldwalking and in geophysical surveys. Method A: Using a Survey Tape When? Use this method to quickly set out a small number of grid squares (up to 20 or so) or to set out a grid in a remote location when you don t want to carry much equipment. What you need Pegs, stakes or canes for each grid corner. A survey tape that is as long as possible (at least 3 times your grid size) Step 1: Establish a baseline Place a peg near one end of your site, then stretch a tape out across you site and place a second peg near the opposite end. Make sure the length of your baseline is a multiple of your intended grid size. So if you will be setting out 30m grids your baseline could be 30m, 60m, 90m long, etc.. If your tape isn t long enough to stretch across your site then just stretch it across the middle of your site. If your site is much larger than your tape then you re better off using Method B below.

Step 2: Place pegs along your baseline With your tape running between your two baseline pegs, place further pegs at each grid-size interval (so for 30m grids, place a peg every 30m). Step 3: Place further pegs using right-angled triangles For this step you will need to know the diagonal length for your grid size. Fortunately the most commonly used grid sizes have easily memorable diagonals as shown in the table below. For other grid sizes use Pythagoras Theorem as shown in the last row below: Grid Size Diagonal 10m 14.14m 20m 28.28m 30m 42.42m These numbers will allow you to place further pegs at their correct positions as shown below (using the example of 10m grids) In practice, the easiest way to use this method is to fix the end of your tape (the 0m position) onto one of the pegs on your baseline, then fix onto the next peg along the position that is your grid size plus your diagonal (so for 10m grids: 10 + 14.14 = 24.14m).

Now stretch out the 10m position of your tape (or whatever grid size you are using) so that the tape is taut to both pegs. This is your peg location: Next, stretch the position on your tape that equates to your diagonal length (14.14m in the case of 10m grids) - again making sure the tape is taut to both pegs - to place a peg at the final corner of the square: Repeat this process along both sides of your baseline:

If you need to add further pegs, then simply repeat this process using the rows of pegs you have already placed. However, be aware that errors will accumulate as you work further from your baseline. You can also extend lines by eye. To do this, attach the end of your tape to a peg and extend it the required distance in the approximate direction you think the peg should be placed. Then kneel to bring your eye close to the ground and sight along the row of existing pegs to ensure your new peg is placed on the same alignment:

Method B: Using a Level or Total Station When? Use this method when you want to quickly set out a large number of pegs and maintain accuracy over a large area. What you need Pegs, stakes or canes for each grid corner A survey tape that is as long as possible (at least the length of your grid size) A quickset (dumpy) level or a total station, with its tripod A 2 metre ranging pole (non-essential if using a total station on flat terrain) A fellow human that can be persuaded or coerced into assisting your work Step 1: Establish a baseline Place a peg near one end of your site and set up your level or total station directly above it using a plumb bob or laser plumb if your instrument has one. Face your level or total station so that it is pointing across the middle of your survey area (if your survey area is oblong in shape your baseline should extend across the longer axis) then zero the horizontal angle of the instrument: On the level, this is achieved by rotating the plate at the base of the instrument so that 0 coincides with the marker on the angle window. On the Leica Builder total stations it is achieved by pressing the Hz = 0 button when on the THEO screen. Once set, this orientation defines your baseline. Be careful not to knock it out of alignment.

Step 2: Place pegs along your baseline Attach the end of your survey tape to the peg beneath you level or total station, then run it out in the direction of your baseline. When you get to the first grid size interval, turn to face the instrument and hold a peg or ranging pole against the correct distance marker on your tape (i.e. the 30m mark if setting out 30m grids). Your assistant, who has remained next to your level or total station, should sight through the instrument (being careful not to turn it horizontally from its zero position) and indicate whether you need to move left or right to bring the peg onto the baseline. (Over large distances, and particularly in noisy or windy conditions, verbal communication becomes impossible and a system of hand signals is necessary to signal left or right.) Once your peg is the correct distance in the correct direction, place it in the ground. Continue this process along your tape until you reach the end. Then detach the tape from its peg, reattach it to the furthest peg and continue onwards, repeating as necessary until you have a perfectly straight line of pegs running across the length of your survey area. Step 3: Place pegs along perpendicular lines Turn your level or total station so that its horizontal angle reads 90 and lay out another line of pegs up to the edge of your survey area in that direction. Then turn the instrument to 270 and set out a line of pegs in that direction too.

Pick up your level or total station with its tripod and walk to the next peg along your baseline. Set up and level the instrument directly over the peg using the plumb bob or laser plumb. Sight along your baseline to the most distant peg and zero the horizontal angle of the instrument, then turn the instrument to 90 and 270 to set out the next perpendicular line as above. Repeat this process along each peg on your baseline. Step 4: Fill in any missing pegs Fill in any missing pegs either by moving the level or total station to pegs on your perpendicular lines, or simply measure them in by eye (as described in the final step of Method A).