Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Similar documents
Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx / / 2004

Photoelectrics Through-beam Type PA18C.T..., DC

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Cylindrical Photoelectric Sensor CY-100 SERIES

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

W100L: Laser Sensor in Mini- Format

W 9-2: A Versatile, Complete and Compact Series

SU17 Series Fiber Optic Sensors

Technical data. General specifications. Indicators/operating means

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Operating instructions Capacitive level sensor KNQ

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

V 180 Series Photoelectric Switches

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Electrical connection

Amplifier for fiber optics. Dimensioned drawing

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

LUT Luminescence scanners: Seeing what no-one else can

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Electrical connection

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Electrical connection

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Q3X Laser Contrast Sensor

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

DLP600M 6+1 Relay Module for Heating and Cooling Plants

L-GAGE Laser Gauging Sensors

FB10000 Error Messages Troubleshooting

HD Digital MPEG2 Encoder / QAM Modulator

Photoelectric Sensors E3F2

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

Q3X Laser Contrast Sensor

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

DLP200M 2 Relay Module for Heating and Cooling Plants

Operating and indicating elements. 4 x LED green Lighting LED = power and

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

KRF EMC Filters Installation, Operation and Maintenance Manual

Operating Instructions

HD Digital MPEG2 Encoder / QAM Modulator

Q3X Laser Contrast Sensor

WF next: Fork sensors for a wide range of applications

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

DJ Lase BlueStar MK-II LED showlaser. user manual

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

HDCVI Eyeball Camera Lite

Operation Manual for. SCU1 Signal Conditioning Unit

4 Wiring Brochure Wiring and installation of specific control

HDCVI Camera User s Manual

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

TRF STEP-DOWN TRANSFORMER USER MANUAL

Electrical connection

Sensor technologies Proximity sensors Series ST4. Brochure

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Model 1421 Distribution Amplifier

SquareLED - Aura Bar & Matrix Beam Light 100

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

OM2000N INSTALLATION MANUAL

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

MICROMASTER Encoder Module

opengear OPG-1L 50 MHz-2.3 GHz

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

QUICK START GUIDE FLEXSLICE MODULES

2.0 Wall Mount TV Soundbar Instruction Manual

1byone Products Inc E Belmont Street, Ontario, CA Customer Service: GARDEN LASER LIGHT User Manual

KODAK Video Monitor CFH-V10

L-GAGE LG Laser Gauging Sensors

HDCVI Camera User s Manual

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

HDCVI Camera User s Manual

Safety Light Curtain Orion1 Extended

Safety Light Curtain C 4000

DMX LED light effect with 4 lenses

Kramer Electronics, Ltd. USER MANUAL. Models: 622T, Dual Link DVI Optical Transmitter 622R, Dual Link DVI Optical Receiver

Be sure to check the camera is properly functioning, is properly positioned and securely mounted, every time you operate your vehicle.

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

SA1J-F: Full Color Fiber Optic Sensors

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

MKH 8060 Directional studio microphone

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

10 PDUs 19 PDUs Zero-U PDUs

Perle Fast Ethernet Media Converters

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

PNP300 / PNP300UN / PNP350

Type F70AB F70ABPN. Digital display. Simple operation featured

HDOB-ELS5IR28A. 5MP 4-in-1 Bullet Security Camera

Transcription:

Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010

Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting fixture 5 5 Electrical connection6 6 Setup 6 7 Settings6 7.1 Setting of the sensitivity with stationary objects* 6 7. Setting of the sensitivity with moving objects* 8 7.3 Setting of the maximum sensitivity* 9 7.4 Electronic lock 9 7.5 Programming the output function* 9 8 Operation 10 9 Maintenance, repair and disposal10

1 Preliminary note 1.1 Symbols used Instruction > Reaction, result Cross-reference Important note: Non-compliance can result in malfunctions or interference. Information Supplementary note. Safety instructions According to the culus approval Caution - Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure. Visible laser light; CLASS 1 LASER PRODUCT. IEC 6085-1 : 007 Complies with 1 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated June 007. Position of the product label Additional label Example OJ5014 3

3 Functions and features In conjunction with a prismatic reflector or reflective tape the retro-reflective sensor detects objects and materials without contact and indicates their presence by a switching signal. Range: see type label (value referred to prismatic reflector 50 mm x 50 mm). The highly focussed units detect very small objects. Therefore a suitable prismatic reflector (e.g. E07) has to be used. 4 Installation Side lens* Front lens* 1 1 1: : LED pushbutton * In the following sections installation and setup are described using the example of the type with front lens. The functions of the units with side lens are identical. Fix the prismatic reflector or the reflective tape. Align the retro-reflective sensor to it and secure it to a bracket; the light spot must hit the prismatic reflector. Maximum range is only possible with precise alignment. Mount the unit so that the mounting position cannot change (avoid high vibrations!). Laser units with a very small light spot diameter are highly focussed; the slightest change in the mounting position will result in misalignment. 4

The optical position of the laser beam may deviate slightly from the mechanical axis. Therefore we recommend using the fine adjustment units E0975 (front lens) or E0976 (side lens) when mounting the laser units. 4.1 Installation of the supplied mounting fixture Secure the mounting fixture with the screws supplied, then slide the unit into the slot of the fixture until the spring clicks home. To remove the unit press the spring down with a screwdriver and slide the unit out. 5

5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to EN 50178. Disconnect power. Connect the unit as follows: DC PNP 1 4 3 L+ teach L DC NPN Programming of the output function by pushbutton or programming wire ( 7.5 Programming the output function). 1 4 3 L+ teach 6 Setup The retro-reflective sensor is supplied ready to operate (plug & play) set at the max. sensing range. This is sufficient if the retro-reflective sensor can operate with maximum excess gain. The following setting procedures should only be necessary in less straight-forward applications, for example if partly transparent objects must be detected. 7 Settings 7.1 Setting of the sensitivity with stationary objects* Go into the programming mode of the unit. L 1 Press for about s until the red LED flashes. The red LED goes out; the yellow and green LEDs flash alternately. The unit is in the programming mode. 6

Set the sensitivity with object. Press once. The yellow and green LEDs go out for approx. 1 s, then flash again alternately. Set the sensitivity without object. Press once. 3 The yellow and green LEDs go out for approx. 1 s. After approx. 3 s the green LED is on. The unit is in the operating mode. Setting steps and 3 can also be carried out in reverse order. * The sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. Feedback: If setting was not successful via the programming wire, the output will switch for s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting of the sensitivity is not possible (e.g. object signal and background signal are about the same), the red LED flashes after step 3 for approx. s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting button is not activated for 15 minutes during the programming process, the unit passes automatically into the operating mode with the sensitivity being unchanged. 7

7. Setting of the sensitivity with moving objects* Go into the programming mode of the unit. 1 Press for about s until the red LED flashes. The red LED goes out; the yellow and green LEDs flash alternately. The unit is in the programming mode. Allow objects to pass through the detection area during the measurement (about 1 s) (number of objects between min. 8 Hz and max. switching frequency). Press once. The yellow and green LEDs go out for approx. 1 s, then flash again alternately. Allow objects to pass through the detection area during the measurement (about 1 s) (number of the objects between min. 8 Hz and max. switching frequency). Press once. 3 The yellow and green LEDs go out for approx. 1 s. After approx. 3 s the green LED is on. The unit is in the operating mode. * The sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. Feedback: If setting was not successful via the programming wire, the output will switch for s. The unit then passes into the operating mode with the sensitivity being unchanged. 8

If the setting of the sensitivity is not possible (e.g. object signal and background signal are about the same), the red LED flashes after step 3 for approx. s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting button is not activated for 15 minutes during the programming process, the unit passes automatically into the operating mode with the sensitivity being unchanged. 7.3 Setting of the maximum sensitivity* Go into the programming mode of the unit. ( step 1). Align the sensor so that no light is reflected. Press the setting button twice ( steps and 3). * The maximum sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 7.4 Electronic lock Activate the lock by connecting the programming wire for about 15 s -0 s*. De-activate the lock by connecting the programming wire again for 15 s - 0 s*. * To activate the functions the programming wire (pin / WH) is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 7.5 Programming the output function* Press for 10 s. The red LED starts to flash fast after s. Then the yellow and green LEDs flash alternately. After 10 s all LEDs go off, the output function has changed from light-on mode to dark-on mode (or vice versa). * The output function can be programmed in exactly the same way using the programming wire (pin /WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time. 9

8 Operation Check whether the unit operates correctly. Display by LEDs. Green LED on Yellow LED on Red LED on LEDs yellow + red Unit is ready for operation. Output is switched. Error in object detection, e.g. maladjustment, soiling of the lenses Flash alternately, Hz: output short-circuited. Flash alternately, 1 Hz: internal fault. (output is not switched). 9 Maintenance, repair and disposal Keep the lenses of the sensor free from soiling. For cleaning do not use any solvents or cleaning agents which could damage the plastic lenses. Do not try to open the module enclosure. There are no user - serviceable components inside. Technical data and further information at www.ifm.com Select your country Data sheet direct: 10

11