1. General Information:

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

2-output DALI controller


7 Day Digital Time Switch

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Digital Time Switch. Installation & Operating Instructions

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

4 Wiring Brochure Wiring and installation of specific control

MONOPRICE. Blackbird 4K HDMI Extender. User's Manual P/N 24281

LED Driver Linear / area fixed output

ST625TX Digital Room Thermostat

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

APOLO DC B Electric Thermal Radiators

Wireless for HDMI 5 GHz

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

WDK-2500-STROBE. User Guide

MULTIS L72. Operating instructions

LED Driver Compact fixed output

Manual for WMR-252 built-in receiver with universal dimmer

LARGE DIGITAL LED REAL TIME CLOCKS

VAT 20 Adjustable Frequency Drive

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Radio Thermostat Clock

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

By CHANNEL VISION. Flush Mount Amplifier A0350

TED Pro Energy Monitoring and Control System

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

SAL Series Wireless Clock (V1)

SY-HDBT-100 Extender Set

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

2 Hour Electronic Boost Timer

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

MONOPRICE. BitPath AV HDMI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16228

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

NT-9600 Wireless Barcode Scanner. Introduction

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Material: Weight: IP Rating: Cable: Connector:

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

VNS2200 Amplifier & Controller Installation Guide

multi-function meters

RA-RS232, RB-RS232. Setup and Installation Guide Addendum For RadioRA RS232 Interface

Electronic converter for level transmitters MT03L Instructions manual

ET BLU MIX RX-Condo-3

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Quick Start Guide Long Range Wireless 5x2 HDMI Matrix PRO Receiver

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Technical Information

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

OM2000N INSTALLATION MANUAL

Style 5S Clock / Timer

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Tebis application software

INSTALLATION & USER GUIDE

Operating instructions

All the energy of your home, in an App!

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

Generator protection relay

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

7 Day Digital Light Switch with Optional Dusk Start

PCR AUTOMATIC HEAT TREATMENT CONSOLE

Emergency lighting units EM powerled

High performance circuit breakers

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

LED Driver Compact fixed output

HDMI Extender over HDBaseT

A0325. ARIA Audio Streaming Source Receiver with a built in Bluetooth 4.2 Module. ARIA Audio

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

AF-300 E11 Adjustable Frequency Drive

IP Roombox. Hotel Room Management

2.4GHz Digital Wireless Video Door Phone User Manual

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 5

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

LED Driver Compact dimming

7 Day Digital Programmer

Transcription:

Installation guide DRIVER 230 CPL 3 zone weekly programmer using power line carriers DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device complying with the requirements of the directives: 2004/108/CE (electromagnetic compatibility) and 2006/95/CE (low voltage safety). *2701972_Rev.1*

Contents Characteristics............................ 3 General principle........................... 4 Installation............................... 6 Connection............................... 7 Starting up............................... 8 Price programming........................ 12 Wireless option.......................... 14 Associating a door/window magnetic contact... 14 Associating a TYXAL alarm control unit... 15 Associating a TYDOM 200 remote control... 16 Associating a TYXIA remote control... 17 Associating a telephone transmitter TYDOM 300... 19 Deleting all wireless associations... 19 Characteristics 230 V, 50 Hz power supply, ±10% Clock back-up in the event of mains outage: 4h (per condenser) Programming saved permanently Power consumption: 4 VA Class II insulation Operating mode selector knob (9 positions) Selection of 4 continuous modes (Frost Protection, Economy, Comfort, Shutdown) and 1 customizable program by day and by zone Override with automatic return Programmable (1 to 99 days) or continuous frost protection Carrier frequency: 132.5 khz, FSK modulation, X2D protocol Compliant with the NF EN 50065 standard, class 122 "Home" addressing: 65000 factory-coded combinations Digital display Room unit: 124 x 95 x 43 mm Wall mounting on flush-mounted box or projecting Protection index: IP 30 Installation in an environment with normal pollution levels Compatible with the TYDOM 520 for adding home automation functions Operating temperature: 0 to 40 C Storage temperature: -10 C to +70 C Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore. - 3 -

Marche ECS Arrêt Délestage OK CHAUFFAGE Normal Défaut CPL OK Config. Défaut General principle Power line carrier transmission The principle of PLC transmissions is to stack an encoded signal with a higher frequency and weaker amplitude on the signal present between the live and neutral wires (230 V, 50 Hz). Electronic meter DRIVER 230 CPL can be used in blue tariff installations with an area less than 180 m². Transmitter 50 Hz Carrier frequency 230 V mains network Receiver N N L L DRIVER CPL programmer GP4 CPL (optional) GP4 CPL 1 2 3 4 5 6 remote-info Receivers They are of the following types: - TC51089 "Pilot Wire" for controlling 6-order pilot wire convectors (GIFAM standard). - X2D PLC reception circuit boards of various convector manufacturers - X2D PLC radiators The quality of the comfort temperature control depends on the quality of the convector thermostat. N Mains supply L TC51089 PLC receiver (not supplied) Phase coupler Convectors zone 1 TC51089 PLC receiver (not supplied) 1 DHW output Convectors zone 2 Electric water heater TC51089 PLC receiver (not supplied) Convectors zone 3 In three-phase installations, you must use a phase coupler to transmit on the 3 phases simultaneously. N Ph1 Ph2 Ph3-4 - - 5 -

Installation Positioning options The driver can be installed anywhere in your home. That said, having it within reach for programming is an advantage. Mounting To mount the unit on the wall, it must be separated from its base. Once separated from the case, the base must be wall-mounted with screws and plugs or installed in a flush-mounted box (distance between centres 60mm) using the ➊ holes. Knockout partitions are provided for passing the connection wires (➋ : for flush-mounted box, ➌ : for wall-mounting) Connection - Standard UTE NF C15-100 and good practice must be complied with. - Connected or nearby equipment must not generate excessive interference (directives 2004/108/CE). Switch off the mains power before handling the device. Connect the two power leads to the terminal. Replace the device on its base and attach it with the tightening screw. For a projecting mounting, the cable (2 wires, class 2) must reach the unit via a cable duct. Switch on the installation. 2 3 When the installation is switched on for the first time, the display will only appear after around 30 sec. (back-up capacitor charging period). Only an hourglass flashes at this time. Note: To protect the DRIVER CPL power supply, you must use a 10 A circuit breaker at least (do not use a 2 A circuit breaker). - 6 - - 7 -

Starting up Startup mode enables the PLC products to be combined amongst themselves and the installation organisation to be determined (transmitters, receivers, pilot wire type, load shedding, etc.). Note: You may only define one type of pilot wire for each zone. 1 Enter startup mode. Turn the knob to. Set the clock if necessary (see user guide) or press to move onto the next step. The unit displays PArA. Determining the type of pilot wire 2 Press the and buttons simultaneously. The unit displays FP4 (4-order pilot wire) or FP6 (6 order pilot wire) for zone 1. Press the and buttons to determine the type of pilot wire used, then press to validate. Repeat the operation for zones 2 and 3. Z1 Z2 Z3 3 Associating Driver 230 with a transmitter On the DRIVER 230 CPL, you can associate a PLC transmitter type device (GECPL1, GP4 CPL, TYPHONE 2 CPL, etc.). Otherwise, confirm to move onto the next step The unit displays EMET alternating with ----. To associate an energy manager type transmitter (GECPL1, GP4 CPL, etc.) Confirm on the transmitter (see the relevant guide). The display reads GE--. Note: Press to cancel. To associate a PLC telephone remote control type transmitter (TYPHONE 2 CPL) Confirm on the transmitter (see the relevant guide). The display reads --TL. Note: Press to cancel. If DRIVER 230 CPL is associated with 2 types of transmitter, the display reads GETL. 4 Press to confirm your choice and move on to the next stage. - 8 - - 9 -

Starting up 4 Allocation of receivers You must associate each receiver to the central control unit and you can determine the load-shedding channel to which it is allocated (if DRIVER 230 CPL is associated with an energy manager: GECPL1, GP4 CPL, etc.). 4.1 The unit is associated with a GECPL1, GP4 CPL, etc. ➊ Press or to select the load-shedding channel to which the receivers will be allocated. The load-shedding channel can be selected from d:0 to d:6 (d:0 = no load shedding). For use with GECPL1, channels d4, d5 and d6 must not be allocated (no load-shedding). Selecting the load-shedding channel Indication of the relevant heating zone 4.2 The unit is not associated with a GECPL1, GP4 CPL, etc. The "EMET" screen flashes. The identification of the relevant heating zone is displayed. ➊ Confirm on the zone 1 receivers ➋ Press. The unit goes to zone 2. ➌ Confirm on the zone 2 receivers. ➍ Press. The unit goes to zone 3. ➎ Confirm on the zone 3 receivers. ➏ Press Indication of the relevant heating zone to confirm and exit the mode. Z1 Z2 Z3 Z1 Z2 Z3 ➋ Confirm on the relevant receivers. ➌ Repeat operations ➊ and ➋ for the receivers allocated to another load-shedding channel ➍ Press to confirm your selection and move onto zones 2 and 3. Repeat the operation. ➎ Press to confirm and exit the mode. - 10 - - 11 -

Price programming (only in tempo option) The Driver 230 CPL must be combined with a GECPL1 or GP4 CPL energy manager. Price programming is used to select a lower temperature (economy) in periods when electricity is most expensive (e.g. peak hour period, Red day). Prices are programmed using the programs of the electronic meter. Operating Mode Applicable in Economy Periods Turn the knob to. Press to display PArA. Press again to enter the price reduction setting mode. Z1 Z2 Z3 CHAU 0 CHAU 1 CHAU 2 CHAU 3 CHAU 4 CHAU 5 CHAU 6 Off-peak BLUE day WHITE day RED day Peak Off-peak Peak Off-peak Peak ➊ By pressing the or buttons, select the mode desired for a price reduction in zone 1 (Economy, Comf -2 C, Comf -1 C, Comfort (no reduction)). Note: The Comfort -1 C and Comfort -2 C modes are only available with 6-order pilot wire heating. ➋ Press to validate and move onto zones 2 and 3 Repeat the operation, then confirm with. The unit displays the time. CHAU C Period with active price reduction - 12 - - 13 -

Wireless option The TYDOM 520 wireless module lets you associate the following home automation functions: - operation with a door/window magnetic contact, - operation with a TYXAL alarm central control unit - operation with TYXAL remote controls (Delta Dore), - operation with a home automation transmitter (example: TYDOM 300). Installing the module Switch off the mains power before handling the device. Separate the unit from its base. Put the module in its place. Close up the unit. Associating a door/window magnetic contact To associate your Driver CPL with a door/window magnetic contact On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio. Beeep 1 On the receiver, press the test key (it emits a beep). - 14 - On the Driver CPL, radio is no longer displayed. The door/window magnetic contact is associated with the Driver CPL. Repeat the association operation to associate another door/window magnetic contact. Note: it is possible to associate up to 16 home automation products (detectors, emitters, etc.). Associating a TYXAL alarm control unit To set the control unit to Maintenance mode. Simultaneously press the ON and OFF buttons on the remote control for 5 seconds and open the control unit cover. 5 sec. Open the battery cover of the control unit To associate your Driver CPL to a TYXAL alarm central control unit, turn the selector to and press and hold the button for 5 sec. The unit displays radio Press the Test button of the control unit. Check that radio is no longer displayed on the screen The central control unit is associated with the Driver CPL. - 15 - Beeep 1 2 3 4 5 6 7

Wireless option Associating a TYDOM 200 multifunction remote control To associate your Driver CPL with a TYDOM 200 remote control On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio On TYDOM 200, - if the TYDOM 200 remote control screen is not displayed, press one of the domain buttons, home - press the home domain button until the remote control transmits one beep and the 3 sec. symbol flashes, Associating - press on one of the tactile comfort and comfort or economy economy modes buttons of the TYDOM 200 remote control. On the Driver CPL, radio is no longer displayed. BEEP, BEEP BEEP To associate the and buttons of the TYDOM 200. On the Driver CPL, set the selector to the button for 5 sec. The unit reads radio. On the TYDOM 200, press on one of the tactile shutdown or automatic buttons on the remote control. On the Driver CPL, radio is no longer displayed. and press and hold The and buttons of the TYDOM 200 remote control are associated with the Driver CPL. To exit association mode, press another domain button (e.g. lighting ). BEEP, BEEP BEEP Lighting Associating shutdown and automatic modes The and buttons of the TYDOM 200 remote control are associated with the Driver CPL. - 16 - - 17 -

Wireless option Associating a TYXIA remote control To associate your Driver CPL with a TYXIA remote control. On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio. On the transmitter, press and hold down the and buttons together for about 5 seconds. The buttons will light up, go out, then light up again. Release. On the Driver CPL, radio is no longer displayed. The emitter s and buttons are associated with the Driver CPL. They allow for a Comfort or Economy override. Associating a TYDOM 300 telephone transmitter To associate your Driver CPL with a TYDOM 300 telephone transmitter On the Driver CPL, set the selector to hold the button for 5 sec. The unit displays radio. On the TYDOM 300 (transmitter), press the button on the top of the unit. The transmitter emits 3 confirmation beeps. Check that radio is no longer displayed on the screen. and press and The TYDOM 300 transmitter is associated with the DRI- VER CPL. Deleting all the wireless product associations with the Driver CPL On the DRIVER CPL, set the selector to and hold the button down for 10 sec., until the time is displayed (the DRIVER CPL displays radio after the button is held down for 5 sec.). All wireless product associations are deleted. - 18 - - 19 -