Installation guide DRIVER 230 CPL 3 zone weekly programmer using power line carriers DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device complying with the requirements of the directives: 2004/108/CE (electromagnetic compatibility) and 2006/95/CE (low voltage safety). *2701972_Rev.1*
Contents Characteristics............................ 3 General principle........................... 4 Installation............................... 6 Connection............................... 7 Starting up............................... 8 Price programming........................ 12 Wireless option.......................... 14 Associating a door/window magnetic contact... 14 Associating a TYXAL alarm control unit... 15 Associating a TYDOM 200 remote control... 16 Associating a TYXIA remote control... 17 Associating a telephone transmitter TYDOM 300... 19 Deleting all wireless associations... 19 Characteristics 230 V, 50 Hz power supply, ±10% Clock back-up in the event of mains outage: 4h (per condenser) Programming saved permanently Power consumption: 4 VA Class II insulation Operating mode selector knob (9 positions) Selection of 4 continuous modes (Frost Protection, Economy, Comfort, Shutdown) and 1 customizable program by day and by zone Override with automatic return Programmable (1 to 99 days) or continuous frost protection Carrier frequency: 132.5 khz, FSK modulation, X2D protocol Compliant with the NF EN 50065 standard, class 122 "Home" addressing: 65000 factory-coded combinations Digital display Room unit: 124 x 95 x 43 mm Wall mounting on flush-mounted box or projecting Protection index: IP 30 Installation in an environment with normal pollution levels Compatible with the TYDOM 520 for adding home automation functions Operating temperature: 0 to 40 C Storage temperature: -10 C to +70 C Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore. - 3 -
Marche ECS Arrêt Délestage OK CHAUFFAGE Normal Défaut CPL OK Config. Défaut General principle Power line carrier transmission The principle of PLC transmissions is to stack an encoded signal with a higher frequency and weaker amplitude on the signal present between the live and neutral wires (230 V, 50 Hz). Electronic meter DRIVER 230 CPL can be used in blue tariff installations with an area less than 180 m². Transmitter 50 Hz Carrier frequency 230 V mains network Receiver N N L L DRIVER CPL programmer GP4 CPL (optional) GP4 CPL 1 2 3 4 5 6 remote-info Receivers They are of the following types: - TC51089 "Pilot Wire" for controlling 6-order pilot wire convectors (GIFAM standard). - X2D PLC reception circuit boards of various convector manufacturers - X2D PLC radiators The quality of the comfort temperature control depends on the quality of the convector thermostat. N Mains supply L TC51089 PLC receiver (not supplied) Phase coupler Convectors zone 1 TC51089 PLC receiver (not supplied) 1 DHW output Convectors zone 2 Electric water heater TC51089 PLC receiver (not supplied) Convectors zone 3 In three-phase installations, you must use a phase coupler to transmit on the 3 phases simultaneously. N Ph1 Ph2 Ph3-4 - - 5 -
Installation Positioning options The driver can be installed anywhere in your home. That said, having it within reach for programming is an advantage. Mounting To mount the unit on the wall, it must be separated from its base. Once separated from the case, the base must be wall-mounted with screws and plugs or installed in a flush-mounted box (distance between centres 60mm) using the ➊ holes. Knockout partitions are provided for passing the connection wires (➋ : for flush-mounted box, ➌ : for wall-mounting) Connection - Standard UTE NF C15-100 and good practice must be complied with. - Connected or nearby equipment must not generate excessive interference (directives 2004/108/CE). Switch off the mains power before handling the device. Connect the two power leads to the terminal. Replace the device on its base and attach it with the tightening screw. For a projecting mounting, the cable (2 wires, class 2) must reach the unit via a cable duct. Switch on the installation. 2 3 When the installation is switched on for the first time, the display will only appear after around 30 sec. (back-up capacitor charging period). Only an hourglass flashes at this time. Note: To protect the DRIVER CPL power supply, you must use a 10 A circuit breaker at least (do not use a 2 A circuit breaker). - 6 - - 7 -
Starting up Startup mode enables the PLC products to be combined amongst themselves and the installation organisation to be determined (transmitters, receivers, pilot wire type, load shedding, etc.). Note: You may only define one type of pilot wire for each zone. 1 Enter startup mode. Turn the knob to. Set the clock if necessary (see user guide) or press to move onto the next step. The unit displays PArA. Determining the type of pilot wire 2 Press the and buttons simultaneously. The unit displays FP4 (4-order pilot wire) or FP6 (6 order pilot wire) for zone 1. Press the and buttons to determine the type of pilot wire used, then press to validate. Repeat the operation for zones 2 and 3. Z1 Z2 Z3 3 Associating Driver 230 with a transmitter On the DRIVER 230 CPL, you can associate a PLC transmitter type device (GECPL1, GP4 CPL, TYPHONE 2 CPL, etc.). Otherwise, confirm to move onto the next step The unit displays EMET alternating with ----. To associate an energy manager type transmitter (GECPL1, GP4 CPL, etc.) Confirm on the transmitter (see the relevant guide). The display reads GE--. Note: Press to cancel. To associate a PLC telephone remote control type transmitter (TYPHONE 2 CPL) Confirm on the transmitter (see the relevant guide). The display reads --TL. Note: Press to cancel. If DRIVER 230 CPL is associated with 2 types of transmitter, the display reads GETL. 4 Press to confirm your choice and move on to the next stage. - 8 - - 9 -
Starting up 4 Allocation of receivers You must associate each receiver to the central control unit and you can determine the load-shedding channel to which it is allocated (if DRIVER 230 CPL is associated with an energy manager: GECPL1, GP4 CPL, etc.). 4.1 The unit is associated with a GECPL1, GP4 CPL, etc. ➊ Press or to select the load-shedding channel to which the receivers will be allocated. The load-shedding channel can be selected from d:0 to d:6 (d:0 = no load shedding). For use with GECPL1, channels d4, d5 and d6 must not be allocated (no load-shedding). Selecting the load-shedding channel Indication of the relevant heating zone 4.2 The unit is not associated with a GECPL1, GP4 CPL, etc. The "EMET" screen flashes. The identification of the relevant heating zone is displayed. ➊ Confirm on the zone 1 receivers ➋ Press. The unit goes to zone 2. ➌ Confirm on the zone 2 receivers. ➍ Press. The unit goes to zone 3. ➎ Confirm on the zone 3 receivers. ➏ Press Indication of the relevant heating zone to confirm and exit the mode. Z1 Z2 Z3 Z1 Z2 Z3 ➋ Confirm on the relevant receivers. ➌ Repeat operations ➊ and ➋ for the receivers allocated to another load-shedding channel ➍ Press to confirm your selection and move onto zones 2 and 3. Repeat the operation. ➎ Press to confirm and exit the mode. - 10 - - 11 -
Price programming (only in tempo option) The Driver 230 CPL must be combined with a GECPL1 or GP4 CPL energy manager. Price programming is used to select a lower temperature (economy) in periods when electricity is most expensive (e.g. peak hour period, Red day). Prices are programmed using the programs of the electronic meter. Operating Mode Applicable in Economy Periods Turn the knob to. Press to display PArA. Press again to enter the price reduction setting mode. Z1 Z2 Z3 CHAU 0 CHAU 1 CHAU 2 CHAU 3 CHAU 4 CHAU 5 CHAU 6 Off-peak BLUE day WHITE day RED day Peak Off-peak Peak Off-peak Peak ➊ By pressing the or buttons, select the mode desired for a price reduction in zone 1 (Economy, Comf -2 C, Comf -1 C, Comfort (no reduction)). Note: The Comfort -1 C and Comfort -2 C modes are only available with 6-order pilot wire heating. ➋ Press to validate and move onto zones 2 and 3 Repeat the operation, then confirm with. The unit displays the time. CHAU C Period with active price reduction - 12 - - 13 -
Wireless option The TYDOM 520 wireless module lets you associate the following home automation functions: - operation with a door/window magnetic contact, - operation with a TYXAL alarm central control unit - operation with TYXAL remote controls (Delta Dore), - operation with a home automation transmitter (example: TYDOM 300). Installing the module Switch off the mains power before handling the device. Separate the unit from its base. Put the module in its place. Close up the unit. Associating a door/window magnetic contact To associate your Driver CPL with a door/window magnetic contact On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio. Beeep 1 On the receiver, press the test key (it emits a beep). - 14 - On the Driver CPL, radio is no longer displayed. The door/window magnetic contact is associated with the Driver CPL. Repeat the association operation to associate another door/window magnetic contact. Note: it is possible to associate up to 16 home automation products (detectors, emitters, etc.). Associating a TYXAL alarm control unit To set the control unit to Maintenance mode. Simultaneously press the ON and OFF buttons on the remote control for 5 seconds and open the control unit cover. 5 sec. Open the battery cover of the control unit To associate your Driver CPL to a TYXAL alarm central control unit, turn the selector to and press and hold the button for 5 sec. The unit displays radio Press the Test button of the control unit. Check that radio is no longer displayed on the screen The central control unit is associated with the Driver CPL. - 15 - Beeep 1 2 3 4 5 6 7
Wireless option Associating a TYDOM 200 multifunction remote control To associate your Driver CPL with a TYDOM 200 remote control On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio On TYDOM 200, - if the TYDOM 200 remote control screen is not displayed, press one of the domain buttons, home - press the home domain button until the remote control transmits one beep and the 3 sec. symbol flashes, Associating - press on one of the tactile comfort and comfort or economy economy modes buttons of the TYDOM 200 remote control. On the Driver CPL, radio is no longer displayed. BEEP, BEEP BEEP To associate the and buttons of the TYDOM 200. On the Driver CPL, set the selector to the button for 5 sec. The unit reads radio. On the TYDOM 200, press on one of the tactile shutdown or automatic buttons on the remote control. On the Driver CPL, radio is no longer displayed. and press and hold The and buttons of the TYDOM 200 remote control are associated with the Driver CPL. To exit association mode, press another domain button (e.g. lighting ). BEEP, BEEP BEEP Lighting Associating shutdown and automatic modes The and buttons of the TYDOM 200 remote control are associated with the Driver CPL. - 16 - - 17 -
Wireless option Associating a TYXIA remote control To associate your Driver CPL with a TYXIA remote control. On the Driver CPL, set the selector to and press and hold the button for 5 sec. The unit displays radio. On the transmitter, press and hold down the and buttons together for about 5 seconds. The buttons will light up, go out, then light up again. Release. On the Driver CPL, radio is no longer displayed. The emitter s and buttons are associated with the Driver CPL. They allow for a Comfort or Economy override. Associating a TYDOM 300 telephone transmitter To associate your Driver CPL with a TYDOM 300 telephone transmitter On the Driver CPL, set the selector to hold the button for 5 sec. The unit displays radio. On the TYDOM 300 (transmitter), press the button on the top of the unit. The transmitter emits 3 confirmation beeps. Check that radio is no longer displayed on the screen. and press and The TYDOM 300 transmitter is associated with the DRI- VER CPL. Deleting all the wireless product associations with the Driver CPL On the DRIVER CPL, set the selector to and hold the button down for 10 sec., until the time is displayed (the DRIVER CPL displays radio after the button is held down for 5 sec.). All wireless product associations are deleted. - 18 - - 19 -