IMS Mk2 Universe Drive DIN Rail Quick Start Guide TMB 24/7 Technical Support

Similar documents
IMS Mk2 Universe Drive IP65 Quick Start Guide TMB 24/7 Technical Support

IMS MK2 Simple Universe Drive

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

PRESET 10 ARCHITECTURAL OWNERS MANUAL

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

FloppyDrive 3x2 24V and 12V PortableMount USER MANUAL

X-BAR-PRO. Instruction Manual

CL-DMX-2900 Decoder Specification

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

X-CHIP-100-DIP X-CHIP-100-SMD

LED Array Board.

RERUN ARCHITECTURAL DMX512 RECORDER OWNERS MANUAL

Operation Manual Flare software version 8.8 Flare Jr software version 9.3C

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Media Tube HO ActionPad Configuration Manual V0.2 User Version

Pixel LED SPI Digital Controller

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

KAT5.tv AV Distribution System. KAT5 AVRX User Guide

PRODUCT MANUAL. DMX BOSS Wi-Fi Controller. Product Description

ProPlex Digital RGB Drive PortableMount TMB 24/7 Technical Support

RetroTINK 2X - Quick Start Guide

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

ORDER CODE: EQLED65 USER MANUAL

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

User Manual. Version 1.4

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

CT-DMX-300 LED Controller

Chapter 23 Dimmer monitoring

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE

P-2 Installing the monitor (continued) Carry out as necessary

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

Flare Q+, Flare LR Q+, Flare, Flare Jr

ADB 62.5 An old digital protocol developed by ADB. Still in use although not on new products. Uses a 5 pin XLR so don t confuse it with DMX512.

SquareLED - Aura Bar & Matrix Beam Light 100

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Video Server SED-2100R/S. Quick Installation Guide

LEDWash RGBW USER MANUAL

(RGBW)

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

Personal Information Page

Cyclo Series. user manual. MartinArchitectural

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

American DJ. Show Designer. Software Revision 2.08

USER S MANUAL

OPERATOR MANUAL Version 2.3 May 2007

RGB+W RGBWWA. TOTAL POWER CONSUMPTION 6.0 W/ft 12.0 W/ft. FIXTURE WATTAGE 6.0 W/ft 12.0 W/ft

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

Introduction to DMX Control (SCD24 & SCD96)

The Rosco Cube Family

Fusion 120 Zoom. User Manual. Order code: EQLED068

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

creamsource User Manual For software V5.0 and above

Manual Addendum For Rerun V1.1 software 12/12/2006, RERUN-A = Serial #06A068, RERUN-P = Serial #06A031

Media Tube HO RGBW Million additive RGB colors; White CCT 6500K. Algorithms enable auto control of white LED by 3-channel RGB values.

2002 Martin Professional A/S, Denmark.

Hex-color RGBAW+UV LED strip light

10 Zone RGB-W LED Controller

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

FWD8000 Dante enabled four wire box

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

广州朗闻光电有限公司 GUANGZHOU LONGMAN PRO LIGHT FACTORY CO,. LTD. Vpower L350. System No.: LQ FULL RGBW

PILOT COVE INTERIOR - INTEGRAL POWER SUPPLY ACTIVE WHITE (TUNABLE)

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

QUICK START GUIDE FLEXSLICE MODULES

Selecon LED Fixtures. PL3 LED Luminaire. Features SPECIFICATION SUBMITTAL

16-WAY DIMMER AL DIM16

Installation Instructions

Media Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Yoke Safety cable loop. Up Light Bulb

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

FB10000 Error Messages Troubleshooting

DMX512 Digital Dimmer Operator Manual

Stratos Duo RGB. User Manual. Order code: EQLED371

192 Channel DMX Controller

ElektraLite LED Dazer RGB

QolorFLEX 4x2.5A Dimmer User s Manual Rev 0.18

SH2RE16A4. Output relay module. Benefits. Description

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

NCM 7216 / 7232 Console OPERATIONS MANUAL

1440/2880 HP RGB+WW+CW

Easyl Installation and Programming Manual. EasylTM Solo. Easyl DMX Controller. Easyl is for RGB LED fixtures with DMX control input.

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

Single sensor setup with NIVEL210

Honeywell HomMed Wireless Scale Quick Reference Guide

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

(((((((((<<<<<<<<<<<<<<<<<<<<Q

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

The body of this product adopts distinctive style design with smooth lines, fine appearance and so on. The whole lamps and lanterns look very good.

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

Aspect 2 Circuit Digital Scene Control

Media Tube HO INSTALLATION GUIDE V1.0. Cover: Media Tube HO RGBW/RGB/White Direct View Media Tube HO RGBW/RGB/White Diffused

Transcription:

IMS Mk2 Universe Drive DIN Rail Quick Start Guide TMB 24/7 Technical Support US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 e-mail: techsupport@tmb.com

Setup IMS DIN Rail devices use a standard Phoenix MSTB screw terminal connector in various pin configurations. Please refer to the wiring diagrams below for correct hook up of the IMS DIN Rail product. 1. Connect the 24 VDC power to the power input located in left top corner. The connector should be wired as depicted in the image below. 2. Connect the DMX signal input to the DMX input located in the right top corner of the unit. The connector should be wired as depicted in the image below. 2.1. To pass DMX to another device, connect the DMX cable to the DMX Thru port located in the right top corner of the unit. The connector should be wired as depicted in the image below.

3. Connect the IMS string cable to one of the two Universe Drive outputs. Note: Up to 64 IMS lamps can be connected to one IMS output. Connection Scheme

The image below shows DMX signal daisy-chaining. Dimensions and Connections

LED Status Information LED Status LED description The Power LED has two states: ON and OFF ON: Unit is receiving power OFF: Unit is not receiving power The DMX INPUT / THRU activity LED has two states: OFF and BLINKING YELLOW. OFF: There is no incoming DMX signal BLINKING YELLOW: There is an incoming DMX signal The IMS OUTPUT activity LED has two states: OFF and BLINKING BLUE. OFF: There is no output power/data signal BLINKING BLUE: There is an active output power/data signal. IMS Output String length LED indicators: The three IMS String length LEDs have three states: ON, OFF, and BLINKING OFF: This setting in not activated BLINKING: The string length setting is not set and needs confirmation ON: The string length setting is activated.

Setting the correct IMS string length setting The IMS string length setting exists to ensure correct and safe data transfer to the IMS strings. To compensate for speed loss over longer cable runs, changing the string length setting changes the speed of data packet transfer. NOTE: Due to the vast amount of customization options available to the IMS Mk2 product range, the terms short, medium, and long may not reflect the actual length of the cable, as number of lamps and other conditions may change the interpretation of which length setting should be used. When setting up the IMS Mk2 system for the first time, be sure to send the IMS DIN Rail IMS Drive a dynamic DMX scene, to ensure the length setting is appropriate to the application. Be sure to test each length setting to ensure the best IMS Mk2 lamp operation. There are the three IMS string length settings: 1) Short length cables 2) Medium length cables 3) Long length cables To change the setting to suit the application, press and hold the Setting Exchange Button at the right bottom corner. Once the currently ON LED begins to blink, blinking the length setting can be changed. By pressing the "Setting Exchange Button", the current setting will advance to the next setting. For example, the current setting is "short cable" and the user wants to change to the "medium cable" setting. In this case the user has to press the "setting exchange button" once. The result is shown in the picture below. When the correct setting has been selected by lighting up the corresponding LED, within five seconds the LED of the selected setting will change its state from blinking to solid on indicating the chosen setting is activated.

Cable Length / Lamp Spacing The following settings are recommended using IMS122CL3 cable. Settings may vary depending on cable type, IMS control data transfer rate, and other conditions. The settings below are examples of different scenarios and their tested results.

Lamp Control The IMS Mk2 system consists of three lamp types: RGBW, Dynamic White, and Clear Golden Warm White filament type. The Universe Drive receives the DMX signal and re-multiplexes this together with the power going to the lamps. Each of the IMS lamps can be controlled individually via DMX. IMS lamps are addressed via the IMS Mk2 Hand Held Programmer (HHP), sold separately. The Warm White Filament lamp uses 1 DMX channel of control (0-255, 0-100%). The Dynamic White lamp uses 2 DMX channels of control, one for Warm White and the second for Cool White (0-255, 0-100%). The RGBW lamps use 4 DMX channels of control (see example below). Channel Value Function Lamp Number Start DMX Address 1 000 255 RED intensity 0% - 100% 1 1 2 000 255 GREEN intensity 0% - 100% 1 3 000 255 BLUE intensity 0% - 100% 1 4 000 255 WHITE intensity 0% - 100% 1 5 000 255 RED intensity 0% - 100% 2 5 6 000 255 GREEN intensity 0% - 100% 2 7 000 255 BLUE intensity 0% - 100% 2 8 000 255 WHITE intensity 0% - 100% 2 9 000 255 RED intensity 0% - 100% 3 9 Frequently Asked Questions How many lamps can be used per output? It is possible to use 64 lamps per output x two outputs = 128 lamps per Universe Drive. However, the maximum lamps possible may vary depending length and type of cable. Please refer to the Cable Length diagram in this guide. What is the transcoding setting and what does it do? Signal Transcoding is an option to allow for longer cable runs either by longer leadins, longer socketed lengths, or a greater number of lamps. Transcoding changes the dimming resolution from 8-bit (256 steps of dimming) to 6-bit (64 steps of dimming). The Transcoding Setting is best when IMS lamps are being used for quick color changes that do not require a long, smooth crossfade. Always try and use the

standard option as it performs best in most situations. Choose the transcoding option as a means to troubleshoot why a string isn t working correctly. When not to use transcoding: The standard, non-transcoding setting has a higher bit-rate and makes for smoother dimming in situations where cable length and/or lamp quantity per string are secondary concerns. Always try to use the standard option if possible. If IMS is being used for applications such as low resolution video type effects, choosing the standard setting will produce better results. Standard color fade. Transcoding will have more steps during this crossfade: Scenario where transcoding will work as desired: How can I patch the DMX addresses into the IMS Mk2 lamps? In order to set the DMX addresses for lamps, a ProPlex IMS Mk2 HHP (Hand held Programmer) is required. The HHP makes it possible to set the required DMX address for each IMS lamp, test individual lamps, and test lamps strings attached to the IMS Universe Drive without the need for a DMX console. Note: The IMS Mk2 Universe Drive DIN Rail has two outputs. Each output can have a maximum of 64 lamps. A maximum of 128 lamps can be connected in total per Universe Drive. TMB 24/7 Technical Support US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 e-mail: techsupport@tmb.com