Immersion Pumps HCT (High Chem) sealless EN

Similar documents
Immersion Pumps HCT (High Chem) sealless

Gear Pump Units For single-line centralized lubrication systems

Gear Pump Units. For single-line lubrication systems

Series description: Wilo-Drain VC

Okta 1000, Roots pump without motor

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Mechanical flow switch for On/Off control

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Product Data Sheet 8506 VW-691

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Product Data Sheet 4656 ZW

In addition to the basic models it is also possible for the units to be outfitted with add-ons.

Series description: Wilo-Sub TWU 3 HS

Revision 2.0 Parts List Minor

AC diagonal module Ø 200 mm

Revision 3.0 Parts List Salvador 1~, 3~

Screw pump Series ALLFUEL AFT

Magnetic Stirrers Magnetic Stirr

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Revision 2.0 Parts List Minette 1~, 3~

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Salvador 1~, 3~

Product Data Sheet 4656 EZ

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Eddy Current Probe System

llen-bradley 194R-HM4-NFPA3

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Parts List _2.1. Flygt /.190

Parts List _2.1. Flygt /.890

SMALL OIL SEALED PUMPS

SIMOTICS GP 1LA/1LP/1PP Standard Motors

Küba comfort DP. Draught-free ventilation and extremely quiet operation

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Revision 1.0 Parts List Mini

Product Data Sheet 4650 N-465

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Oil/air cooler. Table of contents. Features. Applications. RE 50112/05.13 Replaces: Type KOL and KOLP

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model KT 53 Cooling incubators with thermoelectric cooling

2.9 Sigma/ 2 Plunger Metering Pumps

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Bimetal Temperature Switch

Revision 1.0 Parts List Mega

MVSI-TS. Technical features

Fluid Cooling P-BAR b Industrial BOL Series

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Roof-mounted Blue e+ cooling unit Integration solution VX25

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

MIKRO POWER FACTOR CORRECTION COMPONENTS

Model KBF 720 Constant climate chambers with large temperature / humidity range

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Revision 1.0 Parts List Mega

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

3 Cleaning. 4 Technical data

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Model KT 115 Cooling incubators with thermoelectric cooling

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

Model KBF 1020 Constant climate chambers with large temperature / humidity range

NetterVibration. Netter Electric External Vibrators Series NEG. Serving industry with vibration

Type D mechanical diaphragm

Model KBF 115 Constant climate chambers with large temperature / humidity range

PROPORTIONAL VALVES Sentronic plus

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Bulletin 190 IEC Modular Starter System

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Model KT 170 Cooling incubators with thermoelectric cooling

Admiss. counterpressure

Type: DILM25 10(24V50HZ) Article No.:

Circuit-Breakers for Motor Protection Series 8523/8

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

OPERATING MANUAL FIXED FLOW PUMP DRIVES

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Panel-Mounted Thermostat

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Panel-mounting thermostats, type series EM

HOG 86. The incremental HeavyDuty encoder for highest demands

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Type: DILM12 10(24VDC) Article No.:

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Transcription:

Immersion Pumps HCT (High Chem) sealless 1 6004 EN Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature range 100 C to +100 C Product features Centrifugal pump, 1 to 5 stage models Open impellers Port dimensions to DIN EN 12157 Immersion depths of up to 350 mm Operation on 50 Hz and 60 Hz without impeller change Three phase or single phase motor Quality Management DIN EN ISO 9001: 2008 Environmental Management DIN EN ISO 14001 www.spandaupumpen.com

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 2 Main applications Chemical applications Degreasing facilities Freon, Frigen systems Electroplating equipment Impregnators Industrial furnaces Cooling systems Surface coating equipment Paraffin plants Tempering equipment Washing/cleaning installations etc. Fluids delivered Cooling brines Thermal oils Deionized water Lyes and acids in various concentrations Chemicals, especially organic solvents Detergents and cleansers etc. Temperature range: 100 C to +100 C. (Please note: the maximum permissible operating temperature drops with a rising number of pump stages.) Models Models HCT..H and HCTE..H for 50 or 60 Hz operation; models HCT..K and HCTE..K for 50 and 60 Hz operation (without impeller change). HCT..H and HCT..K = three phase operation; HCTE..H and HCTE..K = single phase operation. Design features sealless (Special models available at extra price to meet special operational requirements.) free floating pump shaft, supported only by motor bearings open impellers 1 to 5 stage models installation and port dimensions to DIN EN 12157 immersion depths of up to 350 mm Sectional view: HCT 17 (3 stage) Mechanical design Component Motor housing Pump union Pump bottom Intermediate chamber Impeller Material Aluminum LCP LCP LCP LCP Shaft Stainless steel 1.4571 Antifriction bearings Shaft packing FKM (FPM) (underneath lower ball bearing) Splash ring (underneath flange) Top splash ring (above pump chamber) V Ring (between fan and motor housing) Radial deep groove ball bearings with seal (RS), with special grease FKM (FPM) FKM (FPM) FKM (FPM)

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 3 Electrical design The drive motors have a sophisticated fail safe winding that is baked instead of impregnated. They meet VDE regulations as well as European motor standards (DIN EN 60034 1/11.95) and the require ments underlying the CE mark. Designs in conformity with non European regulations, e.g. Canadian Standards Association (CSA), Underwriters Laboratories INC. (UL) or special requirements, e.g. the USA or Japan, are possible. Moreover, we also produce models for special operating conditions (e.g. exposure to humidity or dust). The regular models have motor windings designed for continuous operation and connection to a mains voltage of 230/400 V ±10%, 50 Hz in accordance with IEC 38/5.87. On request the motors can be customized to all common mains values. Standard Options Degree of protection IP 54 IP 55 (DIN EN 60034 5/4.88) Insulation class F.B Ambient temperature max. 40 C 50 C and higher (DIN EN 60034 1/11.95) Relative humidity max. 92% 95% and higher (DIN 50015) Site altitude < 1000 m on request (DIN EN 60034 1/11.95) above sea level Electrical parameters 230/400 V, 50 Hz on request 255/440 V, 60 Hz Mains operation three phase single phase AC Number of poles 2 poles 4 poles; multiple speed Terminal box layout (DIN EN 12157) layout 1 layout 2, 3 or 4 material high impact plastic light metal cable entry M16x1.5 M25x1.5 (DIN 40430/2.71) Protective surface synthetic resin Special finish coating lacquer on request. color: RAL 1013 (pearl white) Special protection Used with converter Motor protection (therm istors in the winding/ptc); fan cowl with canopy. on request Tested Safety (GS) regulations specify a motor circuit breaker conform ing to the following tripping characteristic. Installation and operation The unit is installed in a vertical position. The maximum permissible level of fluid is 20 mm beneath the mounting flange (cf. following drawings). Dry running is not permitted. Before startup, fill the pump with fluid for pumping.there is only limited support for short-term operation without such fluid during the feeding operation Operation against closed valve is possible. Direction of rotation: to the left (counterclockwise) as viewed from above looking down on the ventilation side of the motor. Options immersion depth extension tube Model with extension tube if immersion depth deviates from standard. immersion depth Model with agitator blades for fluids with fast sedimentation characteristics. (Please note: higher power required) 20 mm max. permissible level of fluid 50 mm minimum level of fluid when pump switched on 20 mm max. permissible level of fluid Milliseconds Seconds Minutes x rated current Order Example Model Single phase AC current Size H = 50 Hz 60 Hz (with impeller change) K = 50/60 Hz (without impeller change) Immersion depth t HCT 17 H 220 HCT E 17 K 270 Please indicate electrical parameters, e.g. 230/400 V, 50 Hz. When ordering spare parts, always indicate the 10 place serial number (see motor rating plate).

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 4 Model HCT..H, 1 to 5 stage, for 50 or 60 Hz (with impeller change) Characteristics The data apply to fluids with a viscosity of ~1 mm 2 /s at a density of ~1 kg/dm 3. Q max in single phase operation (operation above Q max leads to overload of drive motor) Three phase operation Electrical data Single phase operation Rated Rated Rated Rated Rated Rated Rated Rated Rated Rated power voltage frequency current speed Noise power voltage frequency current speed BC /Y /Y level *) Model [kw] [V] [Hz] [A] [rpm] [db(a)] Model [kw] [V] [Hz] [A] [rpm] [µf] HCT8H 230/400 50 1.11/0.64 2701 HCTE8H 230 50 1.36 2840 0.25 45 0.18 1 stage 255/440 60 0.99/0.57 3350 1 stage 250 60 1.1 3486 6 HCT12H 230/400 50 1.73/1 2667 HCTE12H 230 50 1.8 2700 8 0.37 48 0.35 2 stage 255/440 60 1.49/0.86 3329 2 stage 250 60 2 3220 6 HCT17H 230/400 50 1.73/1 2667 HCTE17H 0.37 48 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 3 stage 255/440 60 1.49/0.86 3329 3 stage HCT22H 230/400 50 2.72/1.57 2753 HCTE22H 0.55 230 50 3.45 2855 12 0.75 54 4 stage 255/440 60 2.37/1.37 3370 4 stage 0.75 250 60 3.97 3380 12 HCT27H 0.75 230/400 50 3.46/2 2846 HCTE27H 54 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 5 stage 0.9 255/440 60 3.46/2 3403 5 stage 1 ) on request *) to DIN EN 60034 9/5.96

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 5 Model HCT..K, 1 to 5 stage, for 50 and 60 Hz (without impeller change ) Characteristics The data apply to fluids with a viscosity of ~1 mm 2 /s at a density of ~1 kg/dm 3. Q max in single phase operation (operation above Q max leads to overload of drive motor) Three phase operation Electrical data Single phase operation Rated Rated Rated Rated Rated Rated Rated Rated Rated Rated power voltage frequency current speed Noise power voltage frequency current speed BC /Y /Y level *) Model [kw] [V] [Hz] [A] [rpm] [db(a)] Model [kw] [V] [Hz] [A] [rpm] [µf] HCT8K 0.18 230/400 50 0.86/0.5 2812 HCTE8K 230 50 1.36 2840 45 0.18 1 stage 0.25 255/440 60 0.99/0.57 3350 1 stage 250 60 1.1 3486 6 HCT12K 230/400 50 1.73/1 2667 HCTE12K 230 50 1.8 2700 8 0.37 48 0.35 2 stage 255/440 60 1.49/0.86 3329 2 stage 250 60 2 3220 6 HCT17K 230/400 50 1.73/1 2667 HCTE17K 0.37 48 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 3 stage 255/440 60 1.49/0.86 3329 3 stage HCT22K 230/400 50 2.72/1.57 2753 HCTE22K 0.55 230 50 3.45 2855 0.75 54 4 stage 255/440 60 2.37/1.37 3370 4 stage 0.75 250 60 3.97 3380 12 HCT27K 0.75 230/400 50 3.46/2 2846 HCTE27K 54 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 5 stage 0.9 255/440 60 3.46/2 3403 5 stage 1 ) on request *) to DIN EN 60034 9/5.96

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 6 øa b Dimensions and Weights of Models H and K t weight ventilated Model [mm] [kg] ø a b 1 ) c motors 25 G ¾ DIN ISO 228 70 ø100 ø130 4.5 c t 90 4.6 120 HCT(E)8 140 1 stage 170 220 270 5.2 130 5.5 160 HCT(E)12 180 2 stage 210 260 310 6 170 5.7 200 HCT(E)17 220 3 stage 250 300 350 6.2 120 98 216 X 120 98 216 X 120 98 216 X minimum fluid level HCT(E)22 4 stage 200 7 230 250 140 104 295 X 280 330 9 ø99 ø7 50 240 7.8 HCT(E)27 270 5 stage 290 320 9.5 140 104 295 X ø115 flange 1 ) For models conforming to CSA and US requirements or for models with free ends of thermistor type protection system in terminal box: +20 mm Standard ventilated motors come without a canopy. If necessary observe the respective safety regulations and laws applying to machinery guards, the motors can be supplied with a canopy at extra charge. Dimension c is then increased by about 25 mm. Please note: All equipment may only be installed and/or assembled by qualified personnel. Observe exist ing safety regulations. To avoid errors please consult our operating instructions.

Immersion Pumps HCT (High Chem), sealless 1 6004 EN 7 +49 (0)30 72002 261 by fax for the right pump Sender company, city, person to contact Date: Operating area: Quantity: Working point Delivery head [m]: Delivery rate [l/min]: Delivery medium Type: Density [kg/dm³]: ph value: Solids content [ppm]: Temperature range [ C]: Viscosity at operating temperature [mm 2 /s]: Chemical analysis (separate page if necessary): Grain size [µm]: Special characteristics: Immersion depth [mm]: Material specifications/recommendations (if no delivery medium chem. specified) Housing: Shaft: Impeller: Seals: Accessories: Electrical parameters Europe /Y 230/400 V, 50 Hz 230 V, 50 Hz 400 V, 50 Hz USA /Y 265/460 V, 60 Hz YY/Y 230/460 V, 60 Hz (option) Japan 200 V, 50 Hz 200 220 V, 60 Hz Other /Y 230/400 V, 50/60 Hz Additional electrical parameters: Insulation class: F.B Type of enclosure IEC 34: IP 55 Ambient temperature [ C] (if >40 C): Options Motor protection (thermistor in winding/ptc): Industrial connectors (DESINA): Fan cowl, with canopy: Frequency converter operation: Special operating conditions: Additional information: We would like to have brochures on: Centrifugal pumps of high tech plastic Centrifugal pumps of metal Centrifugal pumps: PX modular system Screw pumps: LMP Flameproof centrifugal pumps Block pumps

The contents of this publication are the copyrightof the publisher and may not be reproduced (even extracts) unless permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss ordamage whether direct, indirect or consequential arising out of use of the information contained herein. SKF Lubrication Systems Germany GmbH Product department Spandau Pumps Motzener Strasse 35/37 12277 Berlin Germany PF 970444 12704 Berlin Germany Tel. +49 (0)30 72002 0 Fax +49 (0)30 72002 261 www.spandaupumpen.com This brochure was presented by: 1 6004 EN Subject to change without notice. 05/2015