DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists

Similar documents
Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION

SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES

CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

MEMORANDUM. Date: January 11, 2018

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018)

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES

CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail

SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053

G P DIMENSIONAL DATA. Specifications Included in this Booklet:

IBAK Made in Germany. IBAK Helmut Hunger GmbH & Co. KG Wehdenweg Kiel Germany Tel. +49 (0) Fax +49 (0)

May 2016 DIVISION 3 - CW 2145-R4 TABLE OF CONTENTS

Underground Installation of Optical Fiber Cable by Pulling

Take Control of Quality Assurance

MINNEHAHA COUNTY ON-SITE WASTEWATER TREATMENT SITE EVALUATION WORKSHEET Form #1. Land Owner. Legal Description

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Attachment 2 Wastewater

ALDEN COMPUTATIONAL ANALYSIS OF WESTFALL S OPEN CHANNEL MIXER FOR THE COLBORNE SEWAGE TREATMENT PLANT. Solving Flow Problems Since 1894

T850 Day & Night Security Camera

EXHIBIT A Zones Zone 1 (Urban): Zone 2 (Suburban): Zone 3 (Exurban) Blended Rates/Multiple Zones:

Gen-Eye Micro-Scope Video Pipe Inspection System Operating Instructions

TEXAS LOTTERY COMMISSION REQUEST FOR PROPOSALS FOR DRAWING STUDIO AND PRODUCTION SERVICES # RESPONSES TO PROPOSERS QUESTIONS

February Restoration of the Egyptian Theatre preserving our history for future generations

DIVISION 800 INCIDENTAL CONSTRUCTION. 804 MAINTENANCE AND RESTORATION OF HAUL ROAD Record of Restoration and Maintenance of Haul Roads (Set) 804-1

Opera House Rental Technical Requirements (Updated March-24-14)

*** no equipment put on roofs or buildings. Dish must be put in ground 3 feet from building to allow for mowing. ***

Effective Date: September Rev. 12/21/2017- Void After: September Product: Lead Free Plumbing Products File No. 6397

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

11.1. Pipe Diameter. No. of Models. Cable Length. Monitors Color B&W. Page No. Video Inspection

TELECOMMUNICATIONS V S WATER UTILITIES NATURE STRIP CONGESTION. Leigh Trevaskis. Riverina Water County Council

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Product information. Front-door station series with video for surface-mount

Viztrac AM200 User s Guide. Page 1 of 12

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

T/E-Extender TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Life Changers International Church. Job Description

Student Services & Classroom Addition

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

Circuits Assembly September 1, 2003 Duck, Allen

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

1. The contractor shall ensure that: c) Contractor or sub-contractor has at least 5 years experience

ISO INTERNATIONAL STANDARD. Tools for pressing Compression springs with rectangular section Housing dimensions and colour coding

Cable Trouble. The Transit. R. G. Call University of Iowa. Volume 11 Article

HL32D2A. HL32D2A Page 1 of 13

Appendix 6 St. Bernard Basin

Public Works Division Lighting District Fiber Optic Specifications April 2009

Welcome Screen where you will Create an Account, and Log-In to InspectNet thereafter 1

VIDEO-AUDIO Matrix Switcher Series MODEL : AB-5548

Classified Facility Communications Cabling Infrastructure Design Basics. Pedro De Jesus, PE, RCDD, DCDC Senior Technical Consultant CH2M Hill

Standard Frequencies: NaviTrack

Reproduce Amplifier Revision-D

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

Gen-Eye POD & MINI-POD Video Pipe Inspection/Location System Operating Instructions

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Operation Manual VMS 3.0 Video System

RescueBot Drop Test Instructions May 3 rd, 2013

The surge protector is located on the floor next to the left plasma tv stand. Just hit the black power button and all equipment should turn on.

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

Practice, Practice, Practice Using Prototek Digital Receivers

EZiSYSTEM User Manual. Version 1.0 English

HFC CABLE SYSTEM REVIEW

EZiSYSTEM including xf-series. User Manual. Version 1.1 English

MJK 7030 Float Switch Installation Instructions. Applies to Part Numbers , , and ft.

SPECIAL REPORT OF THE SUBCOMMITTEE ON POLARITY STANDARDS 1

MINUTES. Greg Nelson, Chairperson; Mark Ozbun, Treasurer; Dean Fortin, Secretary, Terry Dean, Marilyn Anderson

REGISTRATION FOR 5TH & 6TH GRADE BAND PACKET RETURN COMPLETED BACK PAGE BY JULY 24 TH!

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

REQUEST FOR PROPOSALS: FOR AN INTEGRATED IN-CAR AND BODY-WORN VIDEO MANAGEMENT SYSTEM

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

Telecommunication Infrastructure Project September 20, 2002

O NEof Premium tools for professionals!

Test Sample Ballistic Threat Results. BFD (mm) Model No.: Projectile Shots (fps) Penetrations (lbs.) Min. Max. Min. Max.

Using ITS Technology to Improve Event Management Traffic Adam Lyons, Iteris, Inc.

USER MANUAL ET16 Plus

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

Six Year Capital Plan Fiscal Year

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

Standard Trench/Embankment Installation

TBC & Matrix Switcher TBC-5000 Instruction Manual

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

TABLE OF CONTENTS [LETTER AGREEMENT]

VIP-35 Manual. Video Inspection Probe

Sun Records Albums

About Us. Agenda 11/12/2014. Maximizing Benefits from Telephone and Cable Agreements. Municipal Association of South Carolina November 12, 2014

Experimental Results of the Active Deflection of a Beam from a Kicker System

AUDIO-VISUAL RESOURCES POLICY October 2012

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES

Transcription:

DESIGN CONSULTING ENGINEERS December 12, 2013 Mr. Mark Kozlowski, P.E. Design Manager Chicago Public Schools Capital Improvement Program 125 S. Clark St. ; 17 th Floor Chicago IL, 60603-5322 RE: Ravenswood Elementary School Sewer Cleaning and Televising [Project # 2014-25061-SIT-GEO] Dear Mr. Kozlowski: As per your authorization we have completed the sewer cleaning, televising and video inspection at Ravenswood School according to the Scope of Services in the Job Order Contract. This letter report presents the results of our inspection work as requested. Scope of Services Perform four (4) sewer structures in the public right of way to upstream structures within the boundary of the project. Anticipate 550-700 lf of sewer cleaning. Provide video recording services for the sewers and structures to be cleaned to document the structural integrity of the sewer and connections and to observe any deflections in the sewer where conditions may warrant sewer repair Provide a DVD of the sewer televising Provide a report and exhibit showing the locations of all televised sewers Description of Site Ravenswood Elementary School is located at 4332 N. Paulina St. in Chicago, IL. The existing manholes proposed for cleaning and televising are located south and east of the school building. Please see attached post inspection sketch of sewer system to identify structures and sewer lines in conjunction with DVD footage. Field Inspection - Cleaning and Televising Cleaning and televising work was performed based on the location map supplied as 2013.11.11 Ravenswood Geotech. High pressure jet rodding was utilized to perform cleaning of sewer system. Gen-Eye Underground Sewer Camera system with footage counter, time lapse and infrared lighting capabilities were used to televise and record the pipe conditions of the sewer system.

DESIGN CONSULTING ENGINEERS DCE inspector along with sewer cleaning/televising crew performed and monitored the cleaning and televising operation on December 9, 2013. Access to water spickets and electric outlets was provided by school engineer, Mr. Danny Williams. Manholes A total of 4 manholes, 1 cleanout and associated sewer lines were located and cleaned. A total of 3 manholes on the supplied location map were not found on site and may be buried. Sewer Lines The sewer lines cleaned and televised are combined sewers, pipe materials are vitrified clay pipes, approximately 6 in diameter. Sewer lines were cleaned via jet rod before televising was performed. Please see post inspection sketch, which may slightly differ from supplied location map due to field observations, sewer line description and length of televising is noted below. Description of Line / Length - 1.) MH#1 to West (right pipe) (Title 1 (Ch.1 & 2) of DVD) - 20 of televising, Televising ends near gutter, camera unable to televise further (possibly due to an upward elbow). 2.) MH#1 to West (left pipe) (Title 1 (Ch.3 & 4) of DVD) - 20 of televising, Televising ends near gutter, camera unable to televise further. 3.) MH#1 to East (left pipe) (Title 1 (Ch.4-6) of DVD) - 35 of televising, Televising ends at a buried basin. 4.) MH#1 to East (right pipe) (Title 1 (Ch.7) of DVD) - 7 of televising, Camera under water, unable to televise further. 5.) Cleanout to Northeast (Title 2 of DVD) - 24 of televising, Drops into sewer line at 10, Y-Section at 18 Televising ends at a buried basin at 24. 6.) MH#2 to North (Title 3 (Ch.1&2) of DVD) - 85 of televising, Separation of joint noticed at 28 Possible broken piece of pipe noticed at 31 Fracture in pipe noticed at 85 Televising ends at 85, camera unable to televise further 7.) MH#3 to North (Title 4 (Ch.1&2) of DVD) - 8 of televising, Jet rodder and camera unable to travel beyond 8.

DESIGN CONSULTING ENGINEERS 8.) MH#4 to Northwest (top pipe) (Title 5 (Ch.1) of DVD) - 8 of televising, Upward elbow at 8, camera unable to televise further. 9.) MH#4 to Northwest (bottom pipe) (Title 5 (Ch.1&2) of DVD) - 75 of televising, Fracture noticed at 69, televising ends at a basin (possibly buried basin). 10.) MH#4 to East (Title 5 (Ch.2&3) of DVD) - 46 of televising, Ends at city sewer on Paulina St. 11.) MH#4 to South (Title 5 (Ch.3-5) of DVD) - 84 of televising, Ends at an upward elbow, camera unable to televise further. 12.) MH#4 to North (Title 5 (Ch.5&6) of DVD) - 37 of televising, Ends at 37 north, camera unable to televise further. Inaccessible and Damaged/Possible Repair Items: 1) As mentioned above, several sewer lines contain upward elbows, possibly connecting to gutters/roof drains and contributing to the inaccessibility of televising. However the following sewer lines are inaccessible due to unknown reasons: a.) MH#1 to East (right pipe) b.) MH#3 to North c.) MH#4 to North 2.) Several items which may warrant repair are noticed in a sewer line from manhole #2 in the north direction. The following was noticed: a.) Separation of joint noticed at 28

DESIGN CONSULTING ENGINEERS b.) Possible broken piece of pipe noticed at 31 c.) Misalignment of pipe joint noticed at 53 d.) Fracture in pipe noticed at 85 3.) A fracture in the pipe surface was noticed 69 northwest of manhole #4 (bottom pipe). See image below.

DESIGN CONSULTING ENGINEERS We appreciate this opportunity to be of service and look forward to working with you on future projects. If you have any questions on the subject, please call us. Very Truly Yours, DESIGN CONSULTING ENGINEERS Ahmad Nur Field Engineer Mannan Abdul, P.E. Project Manager Attachments: Post-inspection sketch DVD