Flygt D 8050, 50 Hz. Technical specification

Similar documents
Flygt /190. Parts List

Revision 1.0 Parts List Salvador 1~, 3~

Revision 3.0 Parts List Salvador 1~, 3~

Flygt Submersible Motor Cables

Revision 2.0 Parts List Minette 1~, 3~

Revision 2.0 Parts List Minor

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Range of Borehole Products. Lenntech. Tel Fax

Parts List _2.1. Flygt /.190

Revision 1.0 Parts List Mini

Parts List _2.1. Flygt /.890

Revision 1.0 Parts List Minor

Flygt Handleiding voor installatie, bediening en onderhoud

Revision 1.0 Parts List Mega

Revision 1.0 Parts List Mega

Series description: Wilo-Drain VC

OPERATIONS MANUAL. ba76140e01 02/2013 CONDUCTIVITY CELL FOR ULTRAPURE WATER

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

Series description: Wilo-Sub TWU 3 HS

Series description: Wilo-Jet HWJ

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Series: BPV, BPLHS. Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. Family Curves. Vertical Multi-Stage Pumps.

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

Series: BPV, BPLHS Family Curves

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Immersion Pumps HCT (High Chem) sealless

Single Point Flow Monitor SW118 SW119

Immersion Pumps HCT (High Chem) sealless EN

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

MVSI-TS. Technical features

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Cooling systems for ORBIMAT

Okta 1000, Roots pump without motor

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

CONCRETE CONSOLIDATION

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KT 53 Cooling incubators with thermoelectric cooling

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Model ED 400 Drying and heating chambers Classic.Line with natural convection

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

Model KBF 720 Constant climate chambers with large temperature / humidity range

2.9 Sigma/ 2 Plunger Metering Pumps

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Spring Return dosing pump FM - mechanical diaphragm

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model ED 23 Drying and heating chambers Classic.Line with natural convection

EXPlora. Introduction

Optical Cryostat - Economy

IGNITION TRANSFORMER FOR BURNERS

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Circuit-Breakers for Motor Protection Series 8523/8

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Modular Lube Lubrication Systems System Controls

Ultra Quiet Series Electric Air Handler

Type D mechanical diaphragm

Agilent High Capacity RV Pumps & Roots Pumping Systems

Model KT 115 Cooling incubators with thermoelectric cooling

SMALL OIL SEALED PUMPS

Model KT 170 Cooling incubators with thermoelectric cooling

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Closed Cycle Cryogenic Probe Station

Screw pump Series ALLFUEL AFT

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Fluid Cooling P-BAR b Industrial BOL Series

Optical Cryostat - Omniplex TM

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Speed sensor MiniCoder GEL 2471

WCHE BTU/Hr Watts

Gear Pump Units For single-line centralized lubrication systems

New SV series / Holger Falk / Distributor meeting Page 2

NetterVibration. Netter Electric External Vibrators Series NEG. Serving industry with vibration

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Model KBF 115 Constant climate chambers with large temperature / humidity range

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type "N" Connectors. Type "N" Interface Dimensions

Model KBF P 240 Humidity test chambers with ICH-compliant light source

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

AF-300 E11 Adjustable Frequency Drive

Absolute Encoders Multiturn

Portable Filter Cart Type SPFC

llen-bradley 194R-HM4-NFPA3

SR Series. Spring Return dosing pump D - mechanical diaphragm. The right dosing choice

Split System Air Conditioner

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Transcription:

Flygt D 8050, 50 Hz Technical specification

Table of Contents Table of Contents D 8050... 2 Product... 2 Denomination... 2 Process data... 2 Motor data...2 Cable...2 Monitoring equipment... 2 Material... 3 Weight... 3 Option...3 Accessories...3 LT-Motor rating and performance curve...4 MT-Motor rating and performance curve...5 HT-Motor rating and performance curve... 6 Dimensional drawing...7 Flygt D 8050, 50 Hz Technical specification 1

D 8050 Product Stainless steel submersible pump used for corrosive wastewater containing solids or longfibred material. Denomination Product code 8050.280 Installation Impeller characteristics P, S LT, MT, HT Process data Liquid temperature-standard max +40 C Depth of immersion max 20 m The ph of the pumped liquid 2-14 Liquid density max. 1100 kg/m 3 Motor data Frequency 50 Hz Insulation class H (+180 C) Voltage variation - continuously running max ± 10% - intermittent running max ± 10% Voltage imbalance between phases max 2% No. of starts/hour max 30 Cable Direct-on-line start SUBCAB 4G1,5+2x1,5 mm 2 7G2,5 mm 2 Y/D start SUBCAB 7G2,5+2x1,5 mm 2 Monitoring equipment Thermal contacts opening temp. 125 C 2 Flygt D 8050, 50 Hz Technical specification

Material General Item Material Typical Flygt Material No. Standard Europe Standard USA Impeller Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Pump housing Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Stator housing Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Shaft Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti O-rings Alternative Material 1 Fluorinated rubber Mechanical face seals Alternative Inner seal Outer seal 1 Aluminum oxide/carbon Silicon carbide/ silicon carbide Weight Option See dimensional drawing. Other cables Water Detector in motor and oil housing Flexible protective sheeting for cable Accessories Discharge connections, adapters, hose connections and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. See separate booklet or www.xyleminc.com, for further information. Flygt D 8050, 50 Hz Technical specification 3

LT-Motor rating and performance curve P 2 [kw] 2.5 2.0 424 422 1.5 1.0 430 426 428 9 8 7 6 5 4 H [m] LT 3 426 2 1 0 428 424 430 422 0 5 10 15 20 25 30 35 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 1340 r/min 422 2.2 (3.0) 5.0 18 0.89 424 2.2 (3.0) 5.0 18 0.89 400 V, 50 Hz, 3~, 1410 r/min 426 1.5 (2.0) 3.3 18 0.84 428 1.5 (2.0) 3.3 18 0.84 430 1.5 (2.0) 3.3 18 0.84 Y/D starting current is approximately 1/3 of D starting current. 4 Flygt D 8050, 50 Hz Technical specification

MT-Motor rating and performance curve P 2 [kw] 2.5 2.0 1.5 1.0 448 450 444 446 442 0.5 0.0 H [m] 10 MT 8 6 4 2 450 0 448 444 446 442 0 5 10 15 20 25 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 1340 r/min 442 2.2 (3.0) 5.0 18 0.89 444 2.2 (3.0) 5.0 18 0.89 400 V, 50 Hz, 3~, 1410 r/min 446 1.5 (2.0) 3.3 18 0.84 448 1.5 (2.0) 3.3 18 0.84 450 1.5 (2.0) 3.3 18 0.84 Y/D starting current is approximately 1/3 of D starting current. Flygt D 8050, 50 Hz Technical specification 5

HT-Motor rating and performance curve P 2 [kw] 3.0 2.5 2.0 1.5 1.0 0.5 0.0 H [m] 272 270 268 264 266 262 HT 20 16 12 8 4 0 262 266 264 272 270 268 0 2 4 6 8 10 12 14 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 2800 r/min 262 2.6 (3.5) 5.8 29 0.84 266 2.6 (3.5) 5.8 29 0.84 400 V, 50 Hz, 3~, 2840 r/min 264 2.2 (3.0) 5.0 29 0.81 400 V, 50 Hz, 3~, 2740 r/min 268 1.5 (2.0) 3.9 14 0.81 270 1.5 (2.0) 3.9 14 0.81 272 1.5 (2.0) 3.9 14 0.81 Y/D starting current is approximately 1/3 of D starting current. 6 Flygt D 8050, 50 Hz Technical specification

Dimensional drawing LT, P-installation All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.xyleminc.com or contact your local Xylem representative for more information. All dimensions are in mm. Flygt D 8050, 50 Hz Technical specification 7

LT S-installation LT S-installation 8 Flygt D 8050, 50 Hz Technical specification

MT P-installation MT, S-installation Flygt D 8050, 50 Hz Technical specification 9

MT, S-installation HT, P-installation 10 Flygt D 8050, 50 Hz Technical specification

HT, S-installation HT, S-installation Flygt D 8050, 50 Hz Technical specification 11

HT, S-installation 12 Flygt D 8050, 50 Hz Technical specification

Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,000 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Water Solutions AB Gesällvägen 33 174 87 Sundbyberg Sweden Tel. +46-8-475 60 00 Fax +46-8-475 69 00 http://tpi.xyleminc.com Visit our Web site for the latest version of this document and more information The original instruction is in English. All non-english instructions are translations of the original instruction. 2011 Xylem Inc 899717_2.1_en.US_2012-01_TS_D8050_50Hz