Flygt D 8050, 50 Hz Technical specification
Table of Contents Table of Contents D 8050... 2 Product... 2 Denomination... 2 Process data... 2 Motor data...2 Cable...2 Monitoring equipment... 2 Material... 3 Weight... 3 Option...3 Accessories...3 LT-Motor rating and performance curve...4 MT-Motor rating and performance curve...5 HT-Motor rating and performance curve... 6 Dimensional drawing...7 Flygt D 8050, 50 Hz Technical specification 1
D 8050 Product Stainless steel submersible pump used for corrosive wastewater containing solids or longfibred material. Denomination Product code 8050.280 Installation Impeller characteristics P, S LT, MT, HT Process data Liquid temperature-standard max +40 C Depth of immersion max 20 m The ph of the pumped liquid 2-14 Liquid density max. 1100 kg/m 3 Motor data Frequency 50 Hz Insulation class H (+180 C) Voltage variation - continuously running max ± 10% - intermittent running max ± 10% Voltage imbalance between phases max 2% No. of starts/hour max 30 Cable Direct-on-line start SUBCAB 4G1,5+2x1,5 mm 2 7G2,5 mm 2 Y/D start SUBCAB 7G2,5+2x1,5 mm 2 Monitoring equipment Thermal contacts opening temp. 125 C 2 Flygt D 8050, 50 Hz Technical specification
Material General Item Material Typical Flygt Material No. Standard Europe Standard USA Impeller Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Pump housing Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Stator housing Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 Shaft Stainless steel M0344.2343.02 EN 10088-2 and -3:1995 ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti ASTM/AISI 316L and 316Ti O-rings Alternative Material 1 Fluorinated rubber Mechanical face seals Alternative Inner seal Outer seal 1 Aluminum oxide/carbon Silicon carbide/ silicon carbide Weight Option See dimensional drawing. Other cables Water Detector in motor and oil housing Flexible protective sheeting for cable Accessories Discharge connections, adapters, hose connections and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. See separate booklet or www.xyleminc.com, for further information. Flygt D 8050, 50 Hz Technical specification 3
LT-Motor rating and performance curve P 2 [kw] 2.5 2.0 424 422 1.5 1.0 430 426 428 9 8 7 6 5 4 H [m] LT 3 426 2 1 0 428 424 430 422 0 5 10 15 20 25 30 35 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 1340 r/min 422 2.2 (3.0) 5.0 18 0.89 424 2.2 (3.0) 5.0 18 0.89 400 V, 50 Hz, 3~, 1410 r/min 426 1.5 (2.0) 3.3 18 0.84 428 1.5 (2.0) 3.3 18 0.84 430 1.5 (2.0) 3.3 18 0.84 Y/D starting current is approximately 1/3 of D starting current. 4 Flygt D 8050, 50 Hz Technical specification
MT-Motor rating and performance curve P 2 [kw] 2.5 2.0 1.5 1.0 448 450 444 446 442 0.5 0.0 H [m] 10 MT 8 6 4 2 450 0 448 444 446 442 0 5 10 15 20 25 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 1340 r/min 442 2.2 (3.0) 5.0 18 0.89 444 2.2 (3.0) 5.0 18 0.89 400 V, 50 Hz, 3~, 1410 r/min 446 1.5 (2.0) 3.3 18 0.84 448 1.5 (2.0) 3.3 18 0.84 450 1.5 (2.0) 3.3 18 0.84 Y/D starting current is approximately 1/3 of D starting current. Flygt D 8050, 50 Hz Technical specification 5
HT-Motor rating and performance curve P 2 [kw] 3.0 2.5 2.0 1.5 1.0 0.5 0.0 H [m] 272 270 268 264 266 262 HT 20 16 12 8 4 0 262 266 264 272 270 268 0 2 4 6 8 10 12 14 Q [l/s] Curve/ Impeller No Rated power, kw (hp) Rated current, A Starting current, A Power factor cos j Ex proof version availabl e Installation P S 400 V, 50 Hz, 3~, 2800 r/min 262 2.6 (3.5) 5.8 29 0.84 266 2.6 (3.5) 5.8 29 0.84 400 V, 50 Hz, 3~, 2840 r/min 264 2.2 (3.0) 5.0 29 0.81 400 V, 50 Hz, 3~, 2740 r/min 268 1.5 (2.0) 3.9 14 0.81 270 1.5 (2.0) 3.9 14 0.81 272 1.5 (2.0) 3.9 14 0.81 Y/D starting current is approximately 1/3 of D starting current. 6 Flygt D 8050, 50 Hz Technical specification
Dimensional drawing LT, P-installation All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.xyleminc.com or contact your local Xylem representative for more information. All dimensions are in mm. Flygt D 8050, 50 Hz Technical specification 7
LT S-installation LT S-installation 8 Flygt D 8050, 50 Hz Technical specification
MT P-installation MT, S-installation Flygt D 8050, 50 Hz Technical specification 9
MT, S-installation HT, P-installation 10 Flygt D 8050, 50 Hz Technical specification
HT, S-installation HT, S-installation Flygt D 8050, 50 Hz Technical specification 11
HT, S-installation 12 Flygt D 8050, 50 Hz Technical specification
Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,000 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Water Solutions AB Gesällvägen 33 174 87 Sundbyberg Sweden Tel. +46-8-475 60 00 Fax +46-8-475 69 00 http://tpi.xyleminc.com Visit our Web site for the latest version of this document and more information The original instruction is in English. All non-english instructions are translations of the original instruction. 2011 Xylem Inc 899717_2.1_en.US_2012-01_TS_D8050_50Hz