Access Control Keypad for MK-DV, JB-DV

Similar documents
ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Art M Digital codelock module

WDK-2500-STROBE. User Guide

1 EX5. Technical Characteristics. Dimensions

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

INSTALLATION INSTRUCTIONS FOR

Art. VR4KCLM-1 - VRCLM Digital codelock

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Instruction Guide. The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB. The Professionals Source For Hard-to-Find Computer Parts

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at

STD-525T PRECISION TIMER

Home Monitoring. Wired Color Camera. User Manual. For indoor/outdoor use. Do not use in wet locations.

OPERATING INSTRUCTIONS. Single Function Timers Model No. 740-T, 740-TJ & 740-TSeries ELECTRICAL TABLE OF CONTENTS

JM-4MED JMW-BA JM-8Z

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

RG NDT INTERNATIONAL INC

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Valcom Wired Digital Clock

Master Clock Controller. User Guide. pyramidtimesystems.com

TAC1 Telephone Entry System

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

Instruction Manual Model # Block Upconverter

SU17 Series Fiber Optic Sensors

Master Clock Controller. User Guide. pyramidtimesystems.com

Instruction Manual Model BlockUpconverter

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

Master Clock Controller. User Guide. pyramidtimesystems.com

LBS-1 (Lowrance Broadband Sounder)

Installation Instructions

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Owners SW-LCD 2.0 Manual & Specifications

Aspect 2 Circuit Digital Scene Control

Product Identification

Remote Tuner Options for the DXE-MBVE-5A Vertical Antenna DXE-MBVE-5UGBRT3 for the MFJ-993BRT 300 Watt Remote Tuner

7 Day Digital Time Switch

GT-1C7-L/GT-1C7 GT-1M3-L/GT-1M3

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

HD POWERLINK SYSTEM USER MANUAL HDP100

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

7 LCD Color Monitor 8 LCD Color Monitor OWNER S MANUAL

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

HTP1502W1 Remote Controlled Multicolor Lighting System

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

OPERATING INSTRUCTIONS. Baked Potato Timer 740-T2B ELECTRICAL TABLE OF CONTENTS

Caution. Hanging the Screen:

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Model /29S RF Splitter

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

Global Water Instrumentation, Inc.

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Documentation on all Paxton products can be found on our web site -

KING-METER USER GUIDE SW-LCD

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

Digital Time Switch. Installation & Operating Instructions

Introduction. Package Contents. Installation Requirements

APSPB PUSH BUTTON ZERO Installation Manual

LED Series Sealed Backlights

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

VNS2210 Amplifier & Controller Installation Guide

INSTRUCTION MANUAL DAFM2

Warner Photoscanner MCS-500 Series LED Photoelectric Control

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

SBL /SBLG Series Wireless Clock

Hip Hop Activity Box. Instruction Manual. Hip Hop Activity Box 22875, October 2018 Copyright ROMPA Ltd

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

For use with QED and hardwired control panels ONLY!

7 3G -SDI Monitor w/ Signal Conversion QUICKSTART GUIDE

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

PLL2210MW LED Monitor

CSA x2 Alarming RS-232 Seq. Video Switcher. Instruction Manual

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Desk Mount Articulating Dual Monitor Arm with Cable Management & Height Adjust

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Home Roam TV Basic User Manual

In-Wall Control Mount for ipod Touch

User Manual DV-HDSS-41-TX. 4x1 4K Scaling Presentation Switcher with Dual Outputs. NOTE: See FSR LIT1628 API manual for serial commands.

EZ-LIGHT K90FDL Daylight Visible

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Transcription:

#91173 0406 Access Control Keypad for MK-DV, JB-DV - INSTRUCTIONS - The KVI is a surface mount electronic access control keypad for use with Aiphone s MK-DV or JB-DV video door station. Designed with the same aesthetic look as the door station, this keypad allows access for authorized personnel with up to 100 unique PIN codes. Use the KVI for residential or commercial applications along with the Aiphone MK or JB Video Entry system for a complete audio, video, and access control package. NAMES & FEATURES KVI Keypad 1 2 NAMES & FUNCTIONS: 1. Operation LEDs 2. Digital keys 3. Zinc diecast case 3 FEATURES: Streamline surface mount design Compatible with MK-DV or JB-DV Can be used as a standalone access control keypad 12-digit backlit panel Programmable with 100 unit pin codes (4 or 5 digits) One programmable master code, 4 or 5-digits 2 request-to-exit inputs 2 Relay outputs: N/O & N/C Red LED lights when relay #1 is activated Green LED lights when relay #2 is activated MOUNTING HARDWARE: Qty Description 1 TORX M4x10 screw 1 TORX T20 Tool 2 M4x30 screw 2 S5 plastic anchor 1 05D 680K varistor Pg. 1

INSTALLATION & MOUNTING Mounting Instructions: 1. After the MK-DV or JB-DV video door station has been installed, position KVI mounting bracket underneath and mark mounting hole positions. (Use exact dimension template on page 3 for positioning.) Top KVI bracket mounting hole should be 1-3/16" below the bottom of the video door station. 2. Drill two mounting holes, 3/16" diameter, 1-3/8" depth (Ø5mm, depth 35mm) and an access hole for the multi-conductor connecting wire. (See illustration on page 3.) 3. Install the plastic anchors in mounting holes. Mount the KVI back plate with the M4x30 screws. 4. Insert the KVI keypad cable in the wiring access hole (lower right corner). Place the KVI keypad against the back plate, leaving a gap of 1/8" to 1/4" between the bottom of the video door station and the top of the keypad. 5. Slide the keypad up (matching up to the bottom of the video door station). The keypad will slide into the clips at the top of the bracket. 6. Make sure the keypad covers the back plate (the bottom of the keypad seated properly on the back plate). Install the M4-10 screw in the bottom of the keypad, using the Allen key to tighten the screw (Torx T20). 1/8" to 3/16" 1 3/16" 1 2 3 1 2 3 1 2 3 2 3/16" 4 5 6 4 5 6 4 5 6 7 8 9 7 8 9 7 8 9 A 0 B A 0 B A 0 B 1 15/16" AIPHONE AIPHONE AIPHONE Pg. 2

INSTALLATION & MOUNTING MOUNTING TEMPLATE: MK-DV or JB-DV 1 3/16" (30mm) 1 15/16" (49mm) Mounting hole 3 9/16" (91mm) 4 5/8" (117mm) 2 3/16" (55mm) KVI BACK PLATE 11/16" (17mm) Mounting hole Wiring hole 3 5/8" (91mm) NOTE: This diagram is actual scale, and can be copied for use as a template for mounting the KVI. Pg. 3

WIRING DIAGRAM 12-24V AC/DC Power in Power in Black Red KVI KEYPAD Strike # 1 power varistor N/O Contact #1 Common Contact. #1 N/C Contact #1 Orange Pink Brown Request-To-Exit Switch #1 NOTE: Either contact can operate an electric strike or magnetic lock (connected with either the Normally Open or Normally Closed output). Request-To-Exit #1 R-T-E Common Request-To-Exit #2 Green Yellow Lt. Blue Lt. Green Request-To-Exit Switch #2 Optional contact for Request-to-Enter function (See page 5) Mag Lock #2 power varistor N/C Contact #2 Common Contact #2 Dark Blue Purple N/O Contact #2 Gray Pg. 4

SETTINGS DEFAULT VALUES: Master code: 12345 Pin Code length: 5 digits Timed relay output (Relay 1 and 2): 1 second Backlit time per use: 10 seconds Key-in keypad time: 120 seconds No Pin codes pre-programmed PIN CODE LENGTH: The Master code and the Pin codes must have the same code length. The Master code and the Pin codes can be set to either a 4 or 5 digit code. All the digit keys on the keypad can be used in a Pin code (0 to 9, A and B). The master code cannot be used as a Pin code. Codes 0000 and 00000 are strictly used to delete a Pin code, and cannot be set as a Pin code. Each key-in on the keypad lights the red LED. REQUEST TO EXIT: The request-to-exit input 1 (green & yellow wires) activates relay 1. The request-to-exit input 2 (blue & yellow wires) activates relay 2. REQUEST TO ENTER: A separate timer or switch may be connected across the light green and yellow wires to allow the 0 button to function as a request-to-enter button. If the timer or switch contact is closed, the 0 button will function as a request-to-enter button. If the contact is open, the 0 button will function normally. SETTING THE CODE LENGTH AND THE MASTER CODE: 1. Enter the master code twice (for the first use, the master code default value is 12345 ). The red LED will light up to confirm entry into programming mode. NOTE: If you change the code length to a 4 digit from the default 5 digit, you must change the master code to a 4 digit code prior to exiting programming or you will not be able to reenter the program mode. If this happens, a manual reset of the system would then be required. Refer to page 6 for reset procedure. 2. Enter A3 to set the code length (both pin code and master code). The green LED will light up for 1 second. Enter 4 for a 4-digit code length or 5 for a 5-digit code length. The green LED will light up to confirm that the code length has been accepted. 3. Enter A4 to modify the master code. The green LED will light up for 1 second. Enter the 4 or 5- digit master code. The green LED will light up for 1 second to confirm that the new master code has been accepted. 4. Press B to exit programming mode. The red LED will turn off to confirm that the unit is no longer in programming mode. NOTE: When the red LED flashes 4 times, it indicates a data computing error. Pg. 5

SETTINGS (Continued) SETTING THE PIN CODES: Group 1: User numbers 00 to 59 activates Relay 1. Group 2: User numbers 60 to 99 activates Relay 2. 1. Enter the master code twice (for the first use, the master code default value is 12345). The red LED will light up to confirm entry into programming mode. 2. Enter the user number (from 0 to 99). If the user number is free, the green LED lights up and turns off right away. If the user number has been previously programmed, the red LED will turn off and come on again immediately. 3. Enter the 4 or 5-digit Pin code. The green LED lights up for 1 second to confirm that the new Pin code has been accepted. NOTES: * If the new Pin code entered is already programmed or is the same as the master code, the red LED flashes 4 times to indicate a data computing error. * The master code cannot be used as a Pin code. Codes 0000 and 00000 are used strictly to delete a Pin code and cannot be used as a Pin code. 4. Press B to exit programming mode. The red LED will turn off to confirm that the unit is no longer in programming mode. SETTING TIME DELAYS: 1. Enter the master code twice (Default setting of the master code is 12345). The red LED will light up to confirm entry into programming mode. 2. Enter A0 to program the keypad s backlight time. The green LED will light up for 1 second. Enter the time in seconds (i.e. 10 for 10 seconds to 99 for 99 seconds). The green LED will light up for 1 second to confirm that the data was accepted. 3. Enter A1 to program the time delay for relay 1. The green LED will light up for 1 second. Enter the time in seconds (i.e. 01 for 1 second up to 99 for 99 seconds). To program a latched contact output, enter 00 (Contact will remain latched upon code entry until the next accepted code is entered). The green LED will light up for 1 second to confirm that the data was accepted. 4. Enter A2 to program the timed delay for relay 2. The green LED will light up for 1 second. Enter the time in seconds (i.e. 01" for 1 second up to 99 for 99 seconds). To program a latched contact output, enter 00 (Contact will remain latched upon code entry until the next accepted code is entered). The green LED will light up for 1 second to confirm that the data was accepted. 5. Press B to exit programming. The red LED will turn off to confirm that the unit is no longer in programming mode. When the Red LED flashes 4 times, a data computing error has occurred. RESET: 1. Enter the master code twice (Default setting of the master code is 12345). The red LED will light up to confirm entry into programming mode. 2. Enter A5. The green LED will light up for 1 second. Press A B to start the reset. The green LED will light up. Wait until the green LED turns off (approximately 3 seconds). The master code will be reset to the factory default value of 12345 and all the Pin codes will be deleted from the keypad. 3. Press B to exit from programming. The red LED will turn off to confirm that the unit is no longer in programming mode. OR 4. Turn the power off. Short the yellow and white wires together. 5. Turn the power back on. The green LED will light while the data is being reset. Separate the yellow and white wires. The green LED will turn off when the reset function is completed. If the short is maintained between the two wires, the green LED will stay lit. Pg. 6

PIN CODE CHART 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Red LED lights on To select code length, enter A3. Green LED will light up for 1 second. Select desired digit length (4 or 5). Green LED will light up to confirm that the change was accepted. To modify master code, enter A4". Green LED will light up for 1 second. Enter new master code. The Green LED will light up to confirm that the change was accepted. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Copy this chart and use as a master copy for the Pin Codes entered into the KVI keypad. Keypad backlit time A0 Master Code Master Code Time delay relay 1 A1 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Time delay relay 2 A2 Enter A1 to program the time delay for relay 1. Green LED will light up for 1 second. Enter time in seconds (01-99). To program a latched output, enter 00. The green LED will light up for 1 second to confirm that the data has been accepted. Enter A2" to program the time delay for relay 2 (same as above A1 above). Enter A0 to program the keypad backlight time. Green LED will light up for 1 second. Enter time in seconds (10-99). The green LED will light up for 1 second to confirm the data has been accepted. Pg. 7

SPECIFICATIONS Input Voltage: 12 to 24V, AC or DC Keypad: 12-digit backlit keypad Outputs: 2 relays N/O & N/C, 6A at 250V PIN Codes: 100 pin codes (4 or 5 digit pin codes programmable in two groups) Master Code: 1 programmable master code, 4 or 5-digit Inputs: 2 request-to-exit inputs 0 key can be used as request-to-enter button, enabled with a timer relay contact Red LED: Programming indicator and relay 1 activation indicator Green LED: Validation in programming mode and relay 2 activation indicator Operating temperature: -4 F to 158 F (-20 C to 70 C) Cable Length: 9 feet Dimensions: MK-DV/JB-DV 6 ¾ H x 3 ⅞ W x 1"D KVI 4 ⅝ H x 3 ⅞ W x 1"D Wires: 13 total. Power = Red, Black Relay 1 = Orange, Brown, Pink Relay 2 = Dark Blue, Purple, Gray 6 ¾ R-T-E = Green, Lt. Blue, Yellow Timer for R-T-E = Lt. Green, Yellow Reset = White, Yellow 11 ½ 3 ⅞ PROGRAM CODES: A0: Set keypad backlit time A1: Set timed output for relay 1 A2: Set timed output for relay 2 A3: Set PIN code length (4 or 5 digits) A4: Modify Master Code A5: Enter Reset Mode 4 ⅝ 1 2 3 4 5 6 7 8 9 A 0 B AIPHONE WARRANTY Aiphone warrants its products to be free from defects in material and workmanship under normal use and service for a period of one year after delivery to the ultimate user. We will repair free of charge or replace at no charge Aiphone product, that upon examination by an Aiphone Repair Technician is proven defective and under warranty. Aiphone reserves the right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty covers bench repairs by the Aiphone Service Department only, and does not extend to units that have been repaired or altered outside of the factory. Aiphone is not responsible for any costs incurred involving on-site service calls. This warranty shall not apply to any Aiphone product that has been subjected to misuse, neglect, accident, power surge, or used in violation of instructions furnished. Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071 Toll Free Technical Support 1-800-692-0200 TOLL FREE FAX LINE: 1-800-832-3765 E-Mail: tech-serv@aiphone.com Pg. 8 KVI Instr. #91173 0406JDJS