english Catalogue 2010/2011 SYSTEMS FOR TIME, LIGHT, CLIMATE

Similar documents
Save energy increase comfort Catalogue 2014/15

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Simply clever! The digital DIN-rail time switches by Grässlin

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

New Times. AlphaRex 3 / MicroRex

Programmable time switches Multiple function - daily/weekly

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Operating instructions. Universal timer switch display

Process transmitter RMA422

All the energy of your home, in an App!

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Actuators IC 20, IC 40

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

LARGE DIGITAL LED REAL TIME CLOCKS

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Level Measurement silometer FMC 420, FMC 423

XTM72E & F Real-Time Clock Modules

Linear flow controls VFC Linear flow controls with actuator IFC

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Linear flow control with actuator IFC

Meteor Product Catalogue

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Tri-level Control HF Sensor

Operating instructions Electronic preset counter Type series 717

Smart Control SC16 3-Channel for matrix

02/11/2015

SAUTER flexotron RDT405 Manual

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

IP Roombox. Hotel Room Management

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

IMPAC Infrared Thermometers

Operating Manual. Basic Control BC16. two-channel for eco moon

Radio-control universal dimmer (built-in type) Installation Instructions

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Catalogue Ignitors and power switches for HID

The modules were designed for in-house use in dry places, but the LEDs (if suited) might also be used in wet environments or outdoor.

Scanning System S-2100

Digital Clock with Second Circle DA Series

Bimetal Temperature Switch

Eaton Durant. Counters, process instruments and hour meters.

Emergency lighting units EM powerled

Multifunction devices

PART 1: HARDWARE. Author: Vandermeerschen M. Version

Luminaire installation box Surface-mounted box Ceiling installation box

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

LCD Thermometer / Clock S No. 1253

Hour Meters / Timers, electronic

Preset counters, electronic

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Premium INSTALLATION AND USER GUIDE ENGLISH TAHOMA BOX. - INSTALLATION AND USER GUIDE. Rev A _01-16

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Danfoss Icon Programmable Room Thermostats, 230 V

Pulse Counters, electromechanical

50 x 50 Compatibility

Nessie Coils for VDH and VDHT valves

Hybrid Chart Recorder 250 mm (10")

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

INSTRUCTION MANUAL HN 50. Master clock MOBATIME BE

XT-17M-B relay - Delay-off, 1 C/O, 16 A

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

CAMTO LTD. Arc detecting system DC/AC

QUICK START GUIDE FLEXSLICE MODULES

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

Pluggable interface relays CR-M Miniature relays

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Model KT 53 Cooling incubators with thermoelectric cooling

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

PHASED OUT. Control module with 3 channels/single, twin push to make switches/ presence detector/modulardim power supply

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies

As versatile as your requirements.

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Ingenium s KNX commitment

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Flexible Counter Series in DIN size 24 x 48 mm

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

ALLEN BRADLEY TIMING RELAY

Flexible Counter Series in DIN size 24 x 48 mm

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

High performance circuit breakers

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

Master Time Clock MTC Users Manual

Panel-mounting Thermostats EM Series

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Electronic Timer Control Day Astronomic Electronic Control

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Emergency lighting units EM powerled

APPLICATIONS. Automatic warehouse. Trasportation lines

R&S Spectrum Rider FPH Handheld spectrum analyzer

Transcription:

english Catalogue 2010/2011 SYSTEMS FOR TIME, IGHT, CIMATE

Product families Digital time switches 9 TR 610 top2 10 TR 612 top2 10 TR 611 top2 12 TR 611 top2 RC 12 TR 622 top2 12 TR 608 top 14 SEEKTA 170 top2 16 SEEKTA 171 top2 RC 16 SEEKTA 172 top2 16 TR 641 top2/rc 18 TR 642 top2/rc 18 TR 644 top2/rc 18 EM 4 top2 20 EM A top2 20 SEEKTA 173 DCF 21 TR 641 S/DCF 22 TR 642 S/DCF 22 TR 644 S/DCF 22 TR 635 top 24 TR 636 top 24 TR 685/2 top 26 TR 030 top 27 theben-eltimo 28 Analogue time switches 31 SY 160 a 32 SU 180 a 32 MEM 190 a 32 SY 151 h 34 SY 161 d 34 SU 181 d 34 SU 191 w 34 TM 171 h 36 SY 161 h 36 SU 181 h 36 TM 178 h 38 SY 168 h 38 SU 188 h 38 MEM 198 h 38 SU 188 g/hw 40 SY 169 s 42 SU 189 s 42 SY 269 h/g 44 SU 289 h/g 44 TM 179 h 46 SU 189 hw 46 SU 285 48 theben-timer 50 FRI 77 h/g 52 Time relays 55 TM 345 M 56 TM 345 B 56 Hour counters 58 BZ 142-1 58 BZ 142-3 58 BZ 143-1 58 BZ 145 58 BZ 146 60 BZ 147 60 BZ 148 60 Presence detectors 63 Präsenzight 360 64 SPHIX 104-360 AP 66 SPHIX 104-360/2 AP 66 SPHIX 104-360 66 SPHIX 104-360/2 66 compact of ce 68 compact of ce DIM 70 compact passage 72 compact passimo WH 74 ECO-IR 360A 76 ECO-IR 360C T 78 ECO-IR DUA-C T 80 PlanoCentro 82 Präsenzight 180 86 ECO-IR 180A 88 compact of ce 24V 90 compact passage 24V 94 ECO-IR 360-24V 96 ECO-IR 180A-24V 98 Motion detectors 101 UXA 101-150 102 UXA 101-180 102 UXA 102-150/150W 104 UXA 102-150/500W 104 UXA 101-360 106 SPHIX 105-110 108 SPHIX 105-220 108 SPHIX 105-300 108 UXA 103-360 110 UXA 103-360/2 110 UXA 103-360 AP 112 UXA 103-360/2 AP 112 UXA 103-200 114 UXA 103-200 T 114 Twilight switches 117 UA 108 118 UA 109 118 UA 110 118 UA 111 top2 120 UA 112 top2 120 UA 120 top2 122 UA 121 top2 RC 122 UA 122 top2 RC 122 UA 126 star 124 UA 127 star 124 UA 128 star 124 UA 129 star-time 124 Staircase time switches 127 EPA 1 128 EPA 6 128 EPA 3 EPA 7 EPA 8 EPA 9 EPA 4 EPA 047 EPA 041 128 128 130 130 130 132 132 Clock thermostats 135 RAMSES 811 top2 136 RAMSES 831 top2 136 RAMSES 812 top2 138 RAMSES 832 top2 138 RAMSES 813 top2 Set 140 RAMSES 833 top2 Set 142 RAMSES 855 top2 OT 144 RAMSES 366/1 top 146 RAMSES 366/2 top 146 RAMSES 784 S 148 RAMSES 722 S 148 RAMSES 782 S 148 RAMSES 784 150 RAMSES 722 150 RAMSES 782 150 RAMSES 721 150 RAMSES 725 150 Room thermostats 153 RAMSES 701 154 RAMSES 702 154 RAMSES 703 154 RAMSES 704 154 RAMSES 705 154 RAMSES 706 RAMSES 707 RAMSES 708 RAMSES 709 RAMSES 741 RAMSES 746 RAMSES 748 RAMSES 741 RA RAMSES 746 RA RAMSES 748 RA RAMSES 714 RAMSES 714 A 154 154 154 154 156 156 156 156 156 156 158 158 RAMSES 714 A/FH 158 RAMSES 751 RA 158 Sensor technology 161 AMU 716 USB 162 AMU 716 R 162 SOTHIS 715 164 KX 167 Switching actuators 168 Dimming actuators 173 Blind actuators 176 Binary inputs 178 Multifunction displays 180 Room thermostats 181 Heating actuators 183 Motor-driven actuator 186 CO 2 sensor 187 Fan coil thermostat 188 Fan coil actuator 189 Motion detectors 190 Presence detectors 192 Weather stations 200 Brightness sensors 201 Temperature sensors 202 Time switches 204 Time transmitter 207 Power supply 208 USB interface 209 ine coupler 209 Secondary clocks 211 UXOR 213 UXOR 400 214 UXOR 404/402 214 UXOR 405 214 DMB 2 S 214 UXOR 408 217 UXOR 409 217 UXOR 411 218 UXOR 412 218 UXOR 413 218 UXOR 414 220 UXOR Sets 221 PHARAO 223 PHARAO-II 10 (AC) 224 PHARAO-II 11 (DC) 224 PHARAO-II 14 (AC) 224 PHARAO-II 15 (DC) 224 PHARAO-II 24 (AC) 224 PHARAO-II 25 (DC) 224 PHARAO-II Upgrade 224 UA 131 DDC 226 SUD 228 II 226 2

Product catalogue 2010 Content Digital time switches Week program Year program Astronomical program 1 TIME Analogue time switches 60 minutes program Day program Week program 2 Time relays/hour counters Time relays Hour counters analogue 3 Hour counters digital Presence detectors 230 V Indoor use 24 V Indoor use 4 IGHT Motion detectors Twilight switches Outdoor use Indoor use 5 DI rail, analogue and digital Wall mounting 6 Staircase time switches DI rail Flush mounting 7 Clock thermostats Digital clock thermostats Analogue clock thermostats 8 CIMATE Room thermostats Mechanical room thermostats Electronic room thermostats 9 Sensor technology CO 2 sensors Hygrostat 10 KX Building automation system Sensors and actors 11 SYSTEMS UXOR 230 V iving comfort control 12 PHARAO 230 V ogic controller 24 V ogic controller 13 ACCESSORIES 14 APPEDIX Index Discontinued models Explanations General conditions Agencies Advertising material order form 15 3

Systems for Time, ight and Climate Your specialist partner Theben AG Your partner for "Energy Saving Ideas" Dear customers and partners We are pleased to present you our new catalogue 2010/2011. With its clear structure and concise form we have considered the wishes and expectations of our customers. Charts show you the most important items of a product familiy, so that you can find quickly the suitable product for your own special application. But that isn`t all. Theben has improved its presentation on the web. Sophisticated search functions help you to find your way to the product you are looking for. You can save informations on leaflets and download them easily. And there are a lot more features to help you with your job. Catalogue and internet are closely linked to help you find the desired information quicker and easier. You enter the selected number of the desired article on www.theben.de/product/, and you get full details like data sheet, operating instructions and so on with one click. Improvements in energy efficiency remains a top issue with Theben. Our successful Energy Saving Ideas are being continually developed. Theben will go on offering intelligent products, systems and solutions which help save energy costs and protect the environment. This catalogue shows you new time switches, presence detectors, clock thermostats and KX products. We are sure that our new media will help you to offer solutions tailored to your customers' needs. Thomas Goes Chairman of the Board 4

Theben AG Systems for Time, ight and Climate Your specialist partner THEBE AG SYSTEMS FOR TIME, IGHT AD CIMATE In the first decades after the foundation in 1921 by P.E. Schwenk, our core competence were solutions for time controlling systems. Since then we have sold more than 30 millons of staircase time switches EPA 8. One of our most famous products is the theben timer, which we also sold more than 30 million times. With subsidiaries in Germany, Great Britain, France, Itlay, Switzerland and a world wide presence in more than 50 countries, our top priority are intelligent solutions for saving energy in daily live. ighting control by twilight switches, presence and motion detectors Climate control by analogue and digital clock thermostats for individual room control KX-systems for building control systems: from lighting and environment control to automatical solar control and weather stations The company is certified according to the international DI ISO 9001:2008 and we have an VDE authorized test laboratory. But we are also noted for our design: In 2009 our multifunction display VARIA 826 KX was honoured with the red dot design award. In 2010 we will go on developing efficient, energy-saving solutions for the controlling of time, light and climate according to our philosophy of Energy Saving Ideas. We will go on offering you exactly the products you want for your customers - the best systems for time, light and climate. 5

Your specialist partner Top Service Theben AG We are here to help you! WHOESAER MARKET Theben holds on to three-stage sales via wholesalers and retail trade. QUAITY Theben means supreme quality, guaranteed by consequental final testing. STORES Quick delivery through central storage. PHOE-HOTIE You can reach us from every building site. Quick assistance by our specialists Phone +49 (0) 74 74/6 92-36 9 Monday to Thursday 7 am to 6 pm Friday 7 am to 4 pm E-MAI-HOTIE Technical experts are always at your service. Quick assistance by our specialists Fax +49 (0) 7474/692-207 and E-mail: tino.schlaich@theben.de (KX) christof.armbruster@theben.de mark.wiest@theben.de REPAIR SERVICE Our service department offers competitive prices for repairs even after the expiry of the warranty period. We also send you the requested spare parts, even for units not in the current range, to satisfy your customers' needs as quickly as possible. Please contact us, we are happy to assist you. 6

Theben AG Your specialist partner Top Service OPERATIG ISTRUCTIOS Operation instructions are available right around the clock. The KX manual provides you with detailed informations for the use of our products. Instructions and other informations can be found free of charge on the internet www.theben.de. KX DATA BASE A constantly update the product data base it is always available on the Internet for free downloading. TEDERS Text for tenders for all Theben products are available on the web for downloading. TRAIIG FACIITIES Trainings are offered in your proximity. Central trainings by our own specialists and peripherally at our partners near your facilities upon request. TRADE FAIRS ational and international trade fairs inform you about our innovations: Mostra Convegno, Milan 23.3. 27.03.2010 light+building, Frankfurt 11.04. 16.04.2010 ECOM, Kiev 13.04. 16.04.2010 EIADE, Oslo 31.05. 03.06.2010 Home Technology Event, ondon 15.06. 17.06.2010 belektro, Berlin 06.10. 08.10.2010 GET ord, Hamburg 17.11. 19.11.2010 SPS/IPC/DRIVES, uremberg 23.11. 25.11.2010 7

TIME 8

Section overview TIME Digital time switches 1 DI rail, 2 modules Program Weekly program Weekly program, Astronomical program Weekly program umber of channels Memory locations External inputs PC interface Memory card included Connection type Type Page 1 56 Spring terminals TR 610 top2 10 2 56 Spring terminals TR 612 top2 10 TR 611 top2 12 1 84 1 Spring terminals TR 611 top2 RC 12 2 84 2 Spring terminals TR 622 top2 12 54 Spring terminals SEEKTA 170 top2 16 1 84 1 Spring terminals SEEKTA 171 top2 RC 16 2 84 2 Spring terminals SEEKTA 172 top2 16 1 28 Screw terminals TR 610 top 24V 15 2 42 Screw terminals TR 612 top 24V 15 DI rail, 1 module Weekly program 1 28 Screw terminals TR 608 top 14 DI rail, 3 modules Yearly program, Astronomical program 1 800 1 Spring terminals TR 641 top2 18 Spring terminals TR 641 top2 RC 18 2 800 2 Spring terminals TR 642 top2 18 Spring terminals TR 642 top2 RC 18 Spring terminals EM A top2 20 DI rail, 4 modules Yearly program, Spring terminals TR 644 top2 18 Astronomical 4 800 4 program Spring terminals TR 644 top2 RC 18 4 4 Spring terminals EM 4 top2 20 DI rail, 6 modules Yearly program, Astronomical program 2 240 Screw terminals SEEKTA 173 DCF 21 1 324 Screw terminals TR 641 S 22 TR 641 S DCF 22 Yearly program 2 324 Screw terminals TR 642 S 22 TR 642 S DCF 22 4 324 Screw terminals TR 644 S 22 TR 644 S DCF 22 Front panel/wall installation Weekly program Wall installation/3-point mounting 1 42 Screw terminals TR 635 top 24 2 42 Screw terminals TR 636 top 24 Weekly program 2 42 Screw terminals TR 685/2 top 26 Flush-mounted Weekly program 1 42 Screw terminals TR 030 top 27 Socket (plug-in) Weekly program 1 36 Plug-in theben-eltimo 020 S 28 33 Plug-in theben-eltimo 020 S DCF 28 9

Digital time switches DI-rail, 2 modules TIME 1 Digital time switches with weekly program TR 610 top2 TR 612 top2 Description Common functions Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 56 memory locations Interface for OBEISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads O-OFF switching times Switching preselection Permanent O/OFF switching Integrated operating hour counter Holiday program Display backlit (can be turned off) PI coding Automatic summer/winter time changeover TR 610 top2 1 channel TR 610 top2 G As TR 610 top2, but: special device with extra relais (gold-bonded contacts) for switching of very low loads TR 612 top2 2 channels Product selection Program Programfunctions umber of channels Switching load < 1 ma Operating voltage Type Article number 230 240 V AC TR 610 top2 6100103 1) 1 230 240 V AC TR 610 top2 G 6100110 Weekly program O/OFF 12 24 V UC TR 610 top2 24V 6104100 * 2 *Available June 2010 1) anguages: GB, E, P, F, D (other article numbers with additional languages on request) 230 240 V AC TR 612 top2 6120103 1) 12 24 V UC TR 612 top2 24V 6124100 * http Additional technical data at: 10 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 2 modules 1 Technical data TR 610 top2 TR 610 top2 G TR 610 top2 24V TR 612 top2 TR 612 top2 24V Operating voltage 230 240 V AC 12 24 V UC 230 240 V AC 12 24 V UC Frequency 50-60 Hz Width 2 modules Installation type DI-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 10 A 2 A 10 A Incandescent/halogen lamps 2600 W 1400 W 2600 W 1400 W Min. switching capacity approx.10 ma <1 ma approx.10 ma Shortest switching time 1 min Time accuracy ± 0.5 s/day(quartz) Power consumption 3 VA Test approvals V V V V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 30 C +55 C Accessories Front panel mounting kit Art.o.: 9070001 Details Page 228 OBEISK top2 PC set Art.o.: 9070409 Details Page 229 OBEISK top2 memory card Art.o.: 9070404 Details Page 230 Wall installation kit 35 mm Art.o.: 9070064 Details Page 230 Connection example TR 610 top2 TR 612 top2 4 5 6 C2 C1 1 2 3 C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 11

Digital time switches DI-rail, 2 modules TIME 1 Digital time switches with weekly program TR 611 top2 TR 611 top2 RC TR 622 top2 Description Common functions Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 84 memory locations Interface for OBEISK top2 memory card (PC programming) OBEISK memory card included in delivery 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads O-OFF switching times Pulse program Cycle program Switching preselection Permanent O/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PI coding Automatic summer/winter time changeover TR 611 top2 1 channel External control input TR 611 top2 RC Time synchronisation option via connection of external DCF or GPS antenna (additional power unit required for GPS if only one device is connected to the antenna). 1 channel External control input TR 622 top2 2 channels 2 external control inputs Product selection Program Weekly program Programfunctions O/OFF Pulse Cycle umber of channels Control inputs 1 1 Time based on Operating voltage Type Article number Quartz Quartz/DCF77/ GPS 2 2 Quartz *Available June 2010 1) anguages: GB, E, P, F, D (other article numbers with additional languages on request) 230 240 V AC T R 611 top2 6 110103 1) 12 24 V UC TR 611 top2 24V 6 114100 * 230 240 V AC TR 611 top2 RC 6110300 12 24 V UC TR 611 top2 RC 24V 6114300 * 230 240 V AC TR 622 top2 6 220103 1) 12 24 V UC TR 622 top2 24V 6 224100 * http Additional technical data at: 12 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 2 modules 1 Technical data TR 611 top2 TR 611 top2 24V TR 611 top2 RC TR 611 top2 RC 24V TR 622 top2 TR 622 top2 24V Operating voltage 230 240 V AC 12 24 V UC 230 240 V AC 12 24 V UC 230 240 V AC 12 24 V UC Frequency 50-60 Hz Width 2 modules Installation type DI-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 10 A Incandescent/halogen lamps 2600 W Min. switching capacity approx.10 ma Shortest switching time 1 s Time accuracy ± 0.5 s/day (Quartz) ± 0.5 s/day (Quartz) or DCF77/ GPS ± 0.5 s/day (Quartz) Power consumption 3 VA Test approvals V V V V V V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 30 C +55 C Accessories OBEISK top2 PC set Art.o.: 9070409 Details Page 229 OBEISK top2 memory card Art.o.: 9070404 Details Page 230 Wall installation kit 35 mm Art.o.: 9070064 Details Page 230 Additional accessories Front panel mounting kit Details Page 228 top2 RC DCF antenna Details Page 228 Antenna top2 RC-GPS Details Page 228 Power unit top2 GPS Details Page 229 Connection example TR 611 top2 TR 611 top2 RC TR 622 top2 Ext1 Ext1 4 5 6 C2 RC DCF max. 100 m C1 1 2 3 max. 100 m C1 1 2 3 RC RC GPS max. 100 m max. 100 m Ext1 Ext2 C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 13

Digital time switches DI-rail, 1 module TIME 1 TR 608 top Description Digital time switch with weekly program 1 channel Screw terminals Text-oriented user guidance in the display 28 memory locations 3 year power reserve (exchangeable lithium battery) O-OFF switching times Switching preselection Permanent O/OFF switching PI coding Automatic summer/winter time changeover Product selection Program umber of channels Memory locations Programfunctions Operating voltage Type Article number Weekly program 1 28 O/OFF 230 V AC TR 608 top 6080002 Technical data TR 608 top Operating voltage Frequency Width Installation type Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 230 V AC 50-60 Hz 1 module DI-rail 3 years 16 A 6 A Incandescent/halogen lamps 1000 W Shortest switching time 1 min Time accuracy ± 1 s/day(quartz) Power consumption 2.5 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +55 C Accessories Wall installation kit 17.5 mm Art.o.: 9070065 Details Page 230 Front panel mounting kit Art.o.: 9070001 Details Page 228 Connection example TR 608 top C1 1 2 3 http Additional technical data at: 14 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 2 modules Digital time switches with weekly program 110 120 V AC/12 24 V UC 1 Description Digital time switch with weekly program Screw terminals Text-oriented user guidance in the display 10 year power reserve (lithium battery) O-OFF switching times Switching preselection Permanent O/OFF switching PI coding Automatic summer/winter time changeover TR 610 top 120V/24V 1 channel 28 memory locations TR 612 top 120V/24V 2 channels 42 memory locations Product selection Program umber of channels Memory locations Programfunctions Operating voltage Type Article number 110 120 V AC TR 610 top 120V 6 101814 1 28 12 24 V UC TR 610 top 24V 6 104002 Weekly program O/OFF 110 120 V AC TR 610 top 120V 6 101814 2 42 110 120 V AC TR 612 top 120V 6121814 12 24 V UC TR 612 top 24V 6124002 Technical data TR 610 top 120V/24 V TR 612 top 120V/24V Operating voltage Frequency Width Installation type Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 110-120 V AC/12-24 V UC 50-60 Hz 2 modules DI-rail 10 years 16 A 10 A Incandescent/halogen lamps 1150 W Shortest switching time 1 min Time accuracy ± 1 s/day(quartz) Power consumption 6 VA Test approvals V W Protection rating IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +55 C Accessories Connection example Wall installation kit 35 mm Art.o.: 9070064 Details Page 230 Front panel mounting kit Art.o.: 9070001 Details Page 228 TR 610 top 120V TR 612 top 120V 4 5 6 C2 C1 1 2 3 C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 15

Digital time switches DI-rail, 2 modules TIME 1 Astronomical time switches with weekly program SEEKTA 170 top2 SEEKTA 171 top2 RC SEEKTA 172 top2 Description Common functions Astronomical time switch with weekly program Astronomical switching function (automatic calculation of sunrise and sunset times for the whole year) DuoFix spring terminals Text-oriented user guidance in the display Interface for OBEISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads Calculated astronomical switching times Programmable O-OFF switching times Switching preselection Permanent O/OFF switching Integrated operating hour counter Holiday program Display backlit (can be turned off) PI coding Automatic summer/winter time changeover SEEKTA 170 top2 1 channel 54 memory locations SEEKTA 171 top2 RC Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna, top2 GPS power unit required, if only one device is connected to the antenna) 1 channel External control input 84 memory locations 3 special programs with yearly date function per channel Count-down timer SEEKTA 172 top2 As SEEKTA 170 top2, but: 2 channels Channel 1 or channel 2 can also be used purely as time switch channel 2 external control inputs 84 memory locations 3 special programs with yearly date function per channel Count-down timer Product selection Program Weekly program, Astronomical program *Available June 2010 Special program Yearly date function umber of channels 1 Control inputs Time based on Operating voltage Type Article number Quartz 1 Quartz/DCF77/GPS 2 2 Quartz 230-240 V AC SEEKTA 170 top2 1700100 12-24 V UC SEEKTA 170 top2 24V 1704100 * 230-240 V AC SEEKTA 171 top2 RC 1710100 12-24 V UC SEEKTA 171 top2 RC 24V 1714100 * 230-240 V AC SEEKTA 172 top2 1720100 12-24 V UC SEEKTA 172 top2 24V 1724100 * http Additional technical data at: 16 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 2 modules 1 Technical data SEEKTA 170 top2 SEEKTA 170 top2 24V SEEKTA 171 top2 RC SEEKTA 171 top2 RC 24V SEEKTA 172 top2 SEEKTA 172 top2 24V Operating voltage 230-240 V AC 12-24 V UC 230-240 V AC 12-24 V UC 230-240 V AC 12-24 V UC Frequency 50-60 Hz Width 2 modules Installation type DI-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 10 A Incandescent/halogen lamps 2600 W 1400 W 2600 W 1400 W 2600 W 1400 W Min. switching capacity approx.10 ma Shortest switching time 1 min Time accuracy ± 0.5 s/day (Quartz) ± 0.5 s/day (Quartz) or DCF77/GPS ± 0.5 s/day (Quartz) Power consumption 3 VA Test approvals V V V V V V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -30 C +55 C Accessories OBEISK top2 PC set Art.o.: 9070409 Details Page 229 OBEISK top2 memory card Art.o.: 9070404 Details Page 230 Wall installation kit 35 mm Art.o.: 9070064 Details Page 230 Additional accessories Front panel mounting kit Details Page 228 antenna top2 RC DCF Details Page 228 Antenna top2 RC-GPS Details Page 228 Power unit top2 GPS Details Page 229 Connection example SEEKTA 170 top2 SEEKTA 171 top2 RC SEEKTA 172 top2 Ext1 4 5 6 C2 C1 1 2 3 max. 100 m + Data C1 1 2 3 RC DCF RC GPS max. 100 m max. 100 m Ext1 Ext2 C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 17

Digital time switches DI-rail, 3 modules, 4 modules TIME 1 Digital time switches with yearly and astronomical time program TR 641 top2 TR 642 top2 RC TR 644 top2 Description Common functions Digital time switch with yearly and astronomical time program DuoFix spring terminals Text-oriented user guidance in the display 800 memory locations Interface for OBEISK top2 memory card (PC programming) 8 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads O-OFF switching times Pulse program Cycle program Extensive annual clock functions Astronomical time switch function (automatic calculation of sunrise and sunset times for the whole year) Switching preselection Permanent O/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PI coding Automatic summer/winter time changeover TR 641 top2 1 channel External control input TR 641 top2 RC Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna) 1 channel External control input Extension module can be connected OBEISK memory card included in delivery TR 642 top2 2 channels 2 external control inputs TR 642 top2 RC As TR 641 top2 RC, but: 2 channels 2 external control inputs TR 644 top2 4 channels 4 external control inputs TR 644 top2 RC As TR 641 top2 RC, but: 4 channels 4 external control inputs Product selection Program umber of channels Control inputs Time based on Memory card included Program functions Operating voltage Type Article number Yearly program, Astronomical program *Available July 2010 1 1 2 2 4 4 Quartz 110-240 V AC TR 641 top2 6410100 * Quartz/DCF77/GPS 110-240 V AC T R 641 top2 RC 6410300 * Quartz Quartz/DCF77/GPS O/OFF Pulse Cycle 110-240 V AC 110-240 V AC TR 642 top2 TR 642 top2 RC 6420100 * 6420300 * Quartz 110-240 V AC TR 644 top2 6440100 * Quartz/DCF77/GPS 110-240 V AC TR 644 top2 RC 6440300 * http Additional technical data at: 18 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 3 modules, 4 modules 1 Technical data TR 641 top2 TR 641 top2 RC TR 642 top2 TR 642 top2 RC TR 644 top2 Operating voltage 110-240 V AC Frequency 50-60 Hz Width 3 modules 4 modules Installation type DI-rail Power reserve 8 years Max. switching capacity at 250 V AC, cos = 1 16 A 2 x 16 A + 2 x 10 A Max. switching capacity at 250 V AC, cos = 0.6 Incandescent/halogen lamps Min. switching capacity Shortest switching time Time accuracy ± 0.5 s/day (Quartz) ± 0.5 s/day (Quartz) or DCF77/GPS ± 0.5 s/day (Quartz) 10 A 2600 W approx.10 ma 1 s ± 0.5 s/day (Quartz) or DCF77/GPS Power consumption 0.5 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -30 C +55 C ± 0.5 s/day (Quartz) TR 644 top2 RC ± 0.5 s/day (Quartz) or DCF77/GPS Accessories OBEISK top2 PC set Art.o.: 9070409 Details Page 229 Antenna top2 RC DCF for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.o.: 9070410 Details Page 228 Antenna top2 RC-GPS for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.o.: 9070610 Details Page 228 Additional accessories Wall installation kit 52.5 mm Details Page 230 Front panel mounting kit Details Page 228 Wall installation kit 70 mm Details Page 230 OBEISK top2 memory card Details Page 230 Connection example TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC RC DCF 4 5 6 C2 RC DCF 4 5 6 10 11 12 C2 C4 RC DCF max. 100 m Ext1 C1 1 2 3 Data RC GPS max. 100 m max. 100 m Ext1 Ext2 C1 1 2 3 Data RC GPS max. 100 m max. 100 m max. 100 m max. 100 m Ext1 Ext2 Ext3 Ext4 Data C1 C3 1 2 3 7 8 9 RC GPS httpadditional technical data at: www.theben.de/product/ Article number 19

Digital time switches DI-rail, 4 modules, 3 modules TIME 1 Extension modules EM 4 top2 EM A top2 Description EM 4 top2 Extension module for TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC 4 channels Width: 4 modules DuoFix spring terminals 4 external inputs Switching preselection Permanent O/OFF switching 4 EDs for displaying switching status Zero-cross switching for relay-saving switching and high lamp loads EM A top2 Ethernet communication module for remote access via A-DS network to time switches TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC Remote programming using OBEISK top2 PC software Direct remote access to time switch (e.g. reading out switching status, performing manual switching, checking time) Width: 3 modules Product selection Type Article number EM 4 top2 6490104 * EM A top2 6490900 * *Available July 2010 Accessories Connection example Front panel mounting kit Art.o.: 9070001 Details Page 228 Additional accessories Wall installation kit 70 mm Details Page 230 Wall installation kit 52.5 mm Details Page 230 EM 4 top2 max. 100 m max. 100 m max. 100 m max. 100 m 4 5 6 10 11 12 C2 C4 Ext1 Ext2 Ext3 Ext4 Data EM A top2 Data C1 C3 1 2 3 7 8 9 http Additional technical data at: 20 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 6 modules SEEKTA 173 DCF 1 Description Astronomical time switch with yearly program 2 channels DCF radio control option via external antenna Astronomical switching function (automatic calculation of sunrise and sunset times for the whole year) Screw terminals 120 memory locations Interface for OBEISK memory card (PC programming) 1.5 year power reserve (exchangeable lithium battery) Calculated astronomical switching times Programmable O-OFF switching times Annual clock function with xed public holidays or date ranges and public holidays dependent on Easter Switching preselection Permanent O/OFF switching Holiday program Programs can be encoded to protect against unauthorised access Automatic summer/winter time changeover Product selection Program umber of channels Memory locations Time based on Operating voltage Type Article number Yearly program, Astronomical program 2 120 Quartz/DCF77 110/230 V AC SEEKTA 173 DCF 1730001 Technical data Operating voltage Frequency Width Installation type Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 110-230 V AC 50-60 Hz 6 modules DI-rail 1.5 years 16 A 10 A SEEKTA 173 DCF Incandescent/halogen lamps 2300 W Shortest switching time 1 min Time accuracy ± 1 s/day (Quartz) or DCF77 Power consumption 8 VA Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -10 C +55 C Accessories Connection example OBEISK PC set Art.o.: 9070230 Details Page 229 Additional accessories DCF77 antenna Details Page 226 Wall installation kit 105 mm Details Page 231 Front panel mounting kit Details Page 228 OBEISK memory card Details Page 230 SEEKTA 173 DCF 4 5 6 C2 110 V~ 230 V~ C1 DCF 1 2 3 7 9 RC DCF httpadditional technical data at: www.theben.de/product/ Article number 21

Digital time switches DI-rail, 6 modules TIME 1 Digital time switches with yearly program TR 641 S TR 642 S DCF TR 644 S Description Common functions Digital time switch with yearly program Screw terminals 324 memory locations Interface for OBEISK memory card (PC programming) 1.5 year power reserve (exchangeable lithium battery) O-OFF switching times Pulse program 1x switching Extensive annual clock functions Switching preselection Permanent O/OFF switching Holiday program Random program Programs can be encoded to protect against unauthorised access Automatic summer/winter time changeover TR 641 S 1 channel TR 641 S DCF 1 channel DCF radio control option via external antenna Separate power unit required for DCF antenna TR 642 S 2 channels TR 642 S DCF 2 channels DCF radio control option via external antenna Separate power unit required for DCF antenna TR 644 S 4 channels TR 644 S DCF 4 channels DCF radio control option via external antenna Separate power unit required for DCF antenna Product selection Program umber of channels Memory locations Time based on Operating voltage Type Article number Yearly program 1 324 2 324 4 324 230-240 V AC TR 641 S 6410001 Quartz 12 V DC TR 641 S 12V 6419012 Quartz/DCF77 230-240 V AC T R 641 S DCF 6410301 Quartz 230-240 V AC T R 642 S 6420001 Quartz/DCF77 230-240 V AC TR 642 S DCF 6420301 230-240 V AC T R 644 S 6440001 120 V AC T R 644 S 120V 6448110 Quartz 24 V UC T R 644 S 24V 6448024 12 V AC T R 644 S 12V 6448012 Quartz/DCF77 230-240 V AC T R 644 S DCF 6440301 http Additional technical data at: 22 www.theben.de/product/ Article number

TIME Digital time switches DI-rail, 6 modules 1 Technical data TR 641 S TR 641 S 12V TR 642 S TR 644 S TR 644 S 120V TR 644 S 24V TR 644 S 12V TR 641 S DCF TR 642 S DCF 230-240 Operating voltage 12 V DC 230-240 V AC 120 V AC 24 V UC 12 V AC 230-240 V AC V AC Frequency 50-60 Hz 50-60 Hz TR 644 S DCF Width Installation type Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 Incandescent/halogen lamps 6 modules DI-rail 1.5 years 16 A 10 A 2300 W Min. switching capacity approx.10 ma Shortest switching time 1 s Time accuracy ± 1 s/day (Quartz) ± 1 s/day (Quartz) or DCF77 Power consumption 8 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -10 C +55 C Accessories OBEISK PC set Art.o.: 9070230 Details Page 229 Antenna DCF77 for TR 641 S DCF, TR 642 S DCF, TR 644 S DCF Art.o.: 9070243 Details Page 228 Power unit DCF77 for TR 641 S DCF, TR 642 S DCF, TR 644 S DCF Art.o.: 9070182 Details Page 229 Additional accessories Front panel mounting kit Details Page 228 Wall installation kit 105 mm Details Page 231 OBEISK memory card Details Page 230 Connection example TR 641 S DCF TR 642 S DCF TR 644 S DCF DCF 4 5 6 C2 DCF 4 5 6 10 11 12 C2 C4 DCF C1 1 2 3 DCF DCF C1 1 2 3 DCF DCF C1 C3 1 2 3 7 8 9 DCF DCF httpadditional technical data at: www.theben.de/product/ Article number 23

Digital time switches Front panel installation/wall installation TIME 1 Digital time switches wall installation TR 635 top TR 636 top Description Common functions Digital timer switch with weekly program Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) O-OFF switching times Pulse program Cycle program Switching preselection Permanent O/OFF switching Holiday program Random program PI coding Automatic summer/winter time changeover TR 635 top 1 channel TR 636 top 2 channels Product selection Program umber of channels Memory locations Programfunctions Weekly program 1 42 2 42 O/OFF, Pulse, Cycle O/OFF, Pulse, Cycle Operating voltage Type Article number 230-240 V AC TR 635 top 6350002 230-240 V AC TR 636 top 6360002 http Additional technical data at: 24 www.theben.de/product/ Article number

TIME Digital time switches Front panel installation/wall installation 1 Technical data TR 635 top TR 636 top Operating voltage 230-240 V AC Frequency 50-60 Hz Installation type Front panel installation/wall installation Power reserve 10 years Max. switching capacity at 250 V AC, cos = 1 16 A 6 A Max. switching capacity at 250 V AC, cos = 0.6 10 A 6 A Incandescent/halogen lamps 2300 W 1200 W Shortest switching time 1 s Time accuracy ± 1 s/day(quartz) Power consumption 6 VA 8 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -10 C +55 C Accessories Quick fastening 72 x 72 Art.o.: 9070071 Details Page 229 Scale drawings TR 635 top, TR 636 top 72 54 69 16 104 66 72 65 25 Connection example TR 635 top TR 636 top C1 1 2 3 7 8 C1 C2 1 2 3 4 5 6 7 8 httpadditional technical data at: www.theben.de/product/ Article number 25

Digital time switches Wall installation/3-point mounting TIME 1 TR 685/2 top Description Digital tariff time switch with weekly program 2 channels Text-oriented user guidance in the display 42 memory locations 6 year power reserve (exchangeable lithium battery) O-OFF switching times Switching preselection Permanent O/OFF switching PI coding Holiday program Display and control panel can be turned by 90 Control ED for battery change Automatic summer/winter time changeover Product selection Program umber of channels Memory locations Programfunctions Operating voltage Type Article number Weekly program 2 42 O/OFF 110 /230 V AC TR 685/2 top 6850012 Technical data TR 685/2 top Operating voltage Frequency Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 110-230 V AC 50-60 Hz 6 years 8 A 2 A Shortest switching time 1 min Time accuracy ± 0.25 s/day(quartz) Power consumption 10 VA Type of protection IP 54 Protection class II in accordance with E 62,054-21 Ambient temperature -25 C +55 C Scale drawings TR 685/2 top Connection example TR 685/2 top 105 74 175 121,5 6,5 230V~ 110V~ C1 C2 1 2 1a 3 4 5 6 7 8 84,5 101,5 http Additional technical data at: 26 www.theben.de/product/ Article number

TIME Digital time switches Flush-mounted TR 030 top 1 Description Digital time switch with weekly program 1 channel Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) O-OFF switching times Pulse program Cycle program Switching preselection Permanent O/OFF switching Holiday program Random program PI coding Automatic summer/winter time changeover Product selection Program umber of channels Memory locations Weekly program 1 42 Programfunctions O/OFF Pulse, Cycle Operating voltage Type Article number 230 V AC TR 030 top 0300002 Technical data TR 030 top Operating voltage Frequency Installation type Power reserve Max. switching capacity at 250 V AC, cos = 1 Max. switching capacity at 250 V AC, cos = 0.6 Incandescent/halogen lamps 230 V AC 50 Hz Flush-mounted wall installation 10 years 10 A 10 A 2300 W Shortest switching time 1 s Time accuracy ± 1 s/day(quartz) Power consumption 6 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature -10 C +35 C Scale drawings TR 030 top Connection example TR 030 top 84 17 6,5 C1 1 2 3 48 50 httpadditional technical data at: www.theben.de/product/ Article number 27

Digital time switches Plug-in TIME 1 Digital plug-in timers theben-eltimo 020 S theben-eltimo 020 S DCF Description Common functions Digital plug-in timer with weekly program Use with earthed sockets (additional socket types upon request) 1 channel Easy operation via keys for program function and day of the week, hours and minutes O-OFF switching times Switching preselection Permanent O/OFF switching Random program Automatic summer/winter time changeover theben-eltimo 020 S 36 memory locations theben-eltimo 020 S DCF DCF radio control 33 memory locations Product selection Program umber of channels Memory locations Time based on Operating voltage Type Article number Weekly program 1 36 Quartz 230 V AC theben-eltimo 020 S 0200000 33 Quartz/DCF77 230 V AC t heben-eltimo 020 S DCF 0200300 http Additional technical data at: 28 www.theben.de/product/ Article number

TIME Digital time switches Plug-in 1 Technical data theben-eltimo 020 S theben-eltimo 020 S DCF Operating voltage 230 V AC Frequency 50 Hz Installation type Socket (plug-in) Power reserve 20 days Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 2 A Incandescent/halogen lamps 3500 W Shortest switching time 1 min Time accuracy ± 1 s/day (Quartz) ± 1 s/day (Quartz) or DCF77 synchronous Power consumption 5 VA Type of protection IP 20 Protection class II for housing, I for plug system as per E 62 730-1 Ambient temperature -10 C +40 C Scale drawings theben-eltimo 020 S, theben-eltimo 020 S DCF 64,8 55 41,3 129,4 101,9 httpadditional technical data at: www.theben.de/product/ Article number 29

TIME 30

Section overview TIME Analogue time switches DI rail, 1 module Program umber of channels Type of contact Power reserve Shortest switching time Programmable every Connection type Daily program 1 O contact 15 min 15 min Screw terminals SY 160 a 32 3 days 15 min 15 min Screw terminals SU 180 a 32 Weekly program 1 O contact 3 days 2 h 2 h Screw terminals MEM 190 a 32 DI rail, 3 modules 60 minute program 1 changeover contact 37.5 s 37.5 s Spring terminals SY 151 h 34 15 min 15 min Spring terminals SY 161 d 34 Daily program 1 changeover contact 200 hours 15 min 15 min Spring terminals SU 181 d 34 Weekly program 1 changeover contact 200 hours 2 h 2 h Spring terminals SU 191 w 34 Type Page 2 Daily program 1 changeover contact 3 days 30 min 30 min Screw terminals SU 181 h 36 60 minute program 1 changeover contact 2 min 37.5 s Screw terminals TM 178 h 38 Daily program 1 changeover contact 30 min 15 min Screw terminals SY 168 h 38 3 days 30 min 15 min Screw terminals SU 188 h 38 Weekly program 1 changeover contact 3 days 4 h 1 h Screw terminals MEM 198 h 38 Daily program 2 2 changeover contacts 3 days 30 min 30 min Screw terminals SU 188 g 40 Daily program and 1/2 day OFF 1 changeover contact 3 days 45 min/12 h 45 min/12 h Screw terminalss SU 188 hw 40 function Front panel/wall installation Daily program 1 changeover contact 15 min 15 min Screw terminals SY 169 s 42 3 days 15 min 15 min Screw terminals SU 189 s 42 1 changeover contact 20 min/2 h 5 min, 30 min Screw terminals SY 269 h 44 2 2 changeover contacts 20 min/2 h 5 min, 30 min Screw terminals SY 269 g 44 Daily program 1 changeover contact 3 days 20 min/2 h 5 min, 30 min Screw terminals SU 289 h 44 2 2 changeover contacts 3 days 20 min/2 h 5 min, 30 min Screw terminals SU 289 g 44 60 minute program 1 changeover contact 1.25 min 18.5 s Screw terminals TM 179 h 46 Daily program and 1/2 day OFF function 1 changeover contact 3 days 30 min/12 h 15 min/12 h Screw terminals SU 189 hw 46 Wall installation/3-point mounting Daily program 1 changeover contact 6 days 20 min 5 min Screw terminals SU 285/1 T 48 2 2 changeover contacts 6 days 20 min 5 min Screw terminals SU 285/2 T 48 Socket (plug-in) Daily program 1 O contact 15 min 15 min Socket intermediate connector theben-timer 26 IP 44 50 theben timer 26 50 Weekly program 1 O contact 2 h 2 h Socket intermediate connector theben timer 27 50 Wall-mounted Daily and defrost 1 changeover contact 2 min/1 h 1 min/1 h Screw terminals FRI 77 h 52 program 2 2 changeover contacts 2 min/1 h 1 min/1 h Screw terminals FRI 77 g 52 Drive with quick fastening for DI rail Daily and defrost program 1 changeover contact 2 min/1 h 1 min/1 h Screw terminals FRI 77 h-2 52 2 2 changeover contacts 2 min/1 h 1 min/1 h Screw terminals FRI 77 g-2 52 31

Analogue time switches DI-rail, 1 module TIME Analogue time switches 1 module switching segments 2 SY 160 a SU 180 a MEM 190 a Description Common functions Analogue time switch 1 channel Screw terminals Manual switch with 3 positions: Permanent O/AUTO/permanent OFF Switching status display SY 160 a Daily program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes SU 180 a As SY 160 a, but: With power reserve (exchangeable imh rechargeable battery) Quartz controlled MEM 190 a Weekly program With power reserve (exchangeable imh rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours Product selection Program Daily program Weekly program umber of channels 1 Power reserve Shortest switching time Programmable every Type of contact Operating voltage Type Article number 15 min 15 min O contact 230 V AC SY 160 a 1600001 3 days 15 min 15 min O contact 230 V AC SU 180 a 1800001 1 3 days 2 h 2 h O contact 230 V AC MEM 190 a 1 900001 http Additional technical data at: 32 www.theben.de/product/ Article number

TIME Analogue time switches DI-rail, 1 module Technical data SY 160 a SU 180 a MEM 190 a Operating voltage 230 V AC 230-240 V AC Frequency 50 Hz 50-60 Hz Width 1 module Installation type DI-rail Program Daily program Weekly program Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 15 min 2 h Programmable every 15 min 2 h Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 25 C +50 C 10 C +50 C 2 Accessories Wall installation kit 17.5 mm Art.o.: 9070065 Details Page 230 Front panel mounting kit Art.o.: 9070001 Details Page 228 Connection example SY 160 a, SU 180 a, MEM 190 a C1 2 1 httpadditional technical data at: www.theben.de/product/ Article number 33

Analogue time switches DI-rail, 3 modules TIME Analogue time switches 3 modules switching segments 2 SY 151 h SU 181 d SU 191 w Description Common functions Analogue time switch 1 channel DuoFix spring terminals Switching preselection Manual switch with 3 positions: Permanent O/AUTO/permanent OFF Switching status display SY 151 h 60 minute program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 37.5 seconds SY 161 d Daily program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction SU 181 d As SY 161 d, but: With power reserve (imh rechargeable battery) Quartz controlled SU 191 w Weekly program With power reserve (imh rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction Product selection Program 60 minute program Daily program Weekly program umber of channels Power reserve Shortest switching time Programmable every 1 37.5 s 37.5 s 1 15 min 15 min 200 hours 15 min 15 min 1 200 hours 2 h 2 h Type of contact Changeover contact Changeover contact Changeover contact Changeover contact Operating voltage Type Article number 230 V AC SY 151 h 1 510011 230 V AC SY 161 d 1610011 110 230 V AC 110 230 V AC SU 181 d 1810011 SU 191 w 1910011 http Additional technical data at: 34 www.theben.de/product/ Article number

TIME Analogue time switches DI-rail, 3 modules Technical data SY 151 h SY 161 d SU 181 d SU 191 w Operating voltage 230 V AC 110-230 V AC Frequency 50 Hz 50-60 Hz Width 3 modules Installation type DI-rail Program 60 minute program Daily program Weekly program Power reserve 200 hours Max. switching capacity at 250 V AC, cos = 1 10 A 16 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 37.5 s 15 min 2 h Programmable every 37.5 s 15 min 2 h Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 20 C +55 C 2 Accessories Wall installation kit 52.5 mm Art.o.: 9070050 Details Page 230 Front panel mounting kit Art.o.: 9070001 Details Page 228 Connection example SY 151 h, SY 161 d, SU 181 d, SU 191 w C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 35

Analogue time switches DI-rail, 3 modules TIME Analogue time switches 3 modules switching segments 12/24 V UC 2 SU 181 h Description SU 181 h Analogue time switch Daily program 1 channel With power reserve (imh rechargeable battery) 48 switching segments Shortest switching time: 30 minutes Screw terminals Switching preselection Permanent O/OFF switch Switching status display Operating indication Simple summer/winter time correction Product selection Program umber of channels Power reserve Shortest switching time Programmable every Type of contact Operating voltage Type Article number Daily program 1 3 days 30 min 30 min Changeover contact 24 V UC S U 181 h 24V 1814008 12 V UC SU 181 h 12V 1817008 http Additional technical data at: 36 www.theben.de/product/ Article number

TIME Analogue time switches DI-rail, 3 modules Technical data SU 181 h 24V SU 181 h 12V Operating voltage 24 V UC 12 V UC Frequency 50-60 Hz Width 3 modules Installation type DI-rail Program Daily program Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 30 min Programmable every 30 min Time accuracy ± 1 s/day(quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 20 C +50 C 2 Accessories Terminal box cover plate 52.5 mm Art.o.: 9070061 Details Page 228 Front panel mounting kit Art.o.: 9070001 Details Page 228 Connection example SU 181 h 12V/24V 7 C1 1 2 3 8 12V/24V httpadditional technical data at: www.theben.de/product/ Article number 37

Analogue time switches DI-rail, 3 modules TIME Analogue time switches 3 modules tappet 2 TM 178 h SU 188 h MEM 198 h Description Common functions Analogue time switch 1 channel Tappets Screw terminals Switching preselection Permanent O/OFF switch Switching status display TM 178 h 60 minute program Without power reserve Synchronised with mains Shortest switching time: 75 seconds 6 tappets included in delivery SY 168 h Daily program Without power reserve Synchronised with mains Shortest switching time: 30 minutes Simple summer/winter time correction Operating indication 6 tappets included in delivery SU 188 h As SY 168 h, but: With power reserve (imh rechargeable battery) Quartz controlled 8 tappets included in delivery MEM 198 h Weekly program With power reserve (imh rechargeable battery) Quartz controlled Shortest switching time: 4 hours 14 tappets included in delivery Product selection Program 60 minute program Daily program Weekly program umber of channels Power reserve Shortest switching time Programmable every 1 2 min 37.5 s 1 30 min 15 min 3 days 30 min 15 min 1 3 days 4 h 1 h Type of contact Changeover contact Changeover contact Changeover contact Changeover contact Operating voltage Type Article number 230 V AC TM 178 h 1780008 230 V AC S Y 168 h 1 680008 230 V AC SU 188 h 1 880008 230 V AC M EM 198 h 1 980008 http Additional technical data at: 38 www.theben.de/product/ Article number

TIME Analogue time switches DI-rail, 3 modules Technical data TM 178 h SY 168 h SU 188 h MEM 198 h Operating voltage 230 V AC Frequency 50 Hz 50-60 Hz Width 3 modules Installation type DI-rail Program 60 minute program Daily program Weekly program Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 10 A 16 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 2 min 30 min 4 h Programmable every 37.5 s 15 min 1 h Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 20 C +55 C 2 Accessories Terminal box cover plate 52.5 mm Art.o.: 9070061 Details Page 228 Front panel mounting kit Art.o.: 9070001 Details Page 228 Connection example TM 178 h, SY 168 h, SU 188 h, MEM 198 h 7 C1 1 2 3 8 httpadditional technical data at: www.theben.de/product/ Article number 39

Analogue time switches DI-rail, 3 modules TIME Analogue time switches 3 modules tappet 2 SU 188 g SU 188 hw Description Common functions Analogue time switch With power reserve (imh rechargeable battery) Quartz controlled Tappets Screw terminals Switching status display Operating indication SU 188 g Daily program 2 channels Fine adjustment to set the time to the minute Shortest switching time: 30 minutes 10 tappets included in delivery SU 188 hw Daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts) Tappets and turning segments Shortest switching time: 45 minutes (12 hours for the 1/2 day OFF function) 6 tappets included in delivery Product selection Program Daily program Daily program and 1/2 day OFF function umber of channels Power reserve Shortest switching time Programmable every 2 3 days 30 min 30 min 1 3 days 45 min/12 h 45 min/12 h Type of contact 2 Changeover contacts Changeover contact Operating voltage Type Article number 230 V AC S U 188 g 1880033 230 V AC SU 188 hw 1 880108 http Additional technical data at: 40 www.theben.de/product/ Article number

TIME Analogue time switches DI-rail, 3 modules Technical data SU 188 g SU 188 hw Operating voltage 230 V AC Frequency 50-60 Hz Width 3 modules Installation type DI-rail Program Daily program Daily program with 1/2 day OFF function Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 10 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 30 min 45 min/12 h Programmable every 30 min 45 min/12 h Time accuracy ± 1 s/day(quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 20 C +55 C 2 Accessories Connection example Terminal box cover plate 52.5 mm Art.o.: 9070061 Details Page 228 Front panel mounting kit Art.o.: 9070001 Details Page 228 SU 188 g SU 188 hw C2 7d 4 5 6 7 4 5 6 7 C1 24h 1 2 3 8 1 2 3 8 httpadditional technical data at: www.theben.de/product/ Article number 41

Analogue time switches Front panel installation/wall installation TIME Analogue time switches wall installation switching segments 2 SY 169 s SU 189 s Description Common functions Analogue time switch with daily program 1 channel 96 switching segments Shortest switching time: 15 minutes Clock hands for time display Switching preselection Permanent O/OFF switch Switching status display Simple summer/winter time correction SY 169 s Without power reserve Synchronised with mains SU 189 s With power reserve (imh rechargeable battery) Quartz controlled Product selection Program Daily program umber of channels 1 Power reserve Shortest switching time Programmable every 15 min 15 min 3 days 15 min 15 min Type of contact Changeover contact Changeover contact Operating voltage Type Article number 230 V AC SY 169 s 1690801 230 V AC SU 189 s 1890801 110 V AC SU 189 s 110V 1891801 http Additional technical data at: 42 www.theben.de/product/ Article number

TIME Analogue time switches Front panel installation/wall installation Technical data SY 169 s SU 189 s SU 189 s 110V Operating voltage 230 V AC 110 V AC Frequency 50 Hz 50-60 Hz Installation type Front panel installation/wall installation Program Daily program Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 10 A Max. switching capacity at 250 V AC, cos = 0.6 2 A Shortest switching time 15 min Programmable every 15 min Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Test approvals W Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +55 C 2 Accessories Scale drawings Connection example Quick fastening 72 x 72 Art.o.: 9070071 Details Page 229 SY 169 s, SU 189 s 54 69 SY 169 s, SU 189 s 72 16 104 66 72 65 25 C1 1 2 3 7 8 httpadditional technical data at: www.theben.de/product/ Article number 43

Analogue time switches Front panel installation/wall installation TIME Analogue time switches wall installation tappet 2 SY 269 h SU 289 g Description Common functions Analogue time switch with daily or weekly program (switching disc can be turned) Tappets Shortest switching time: 20 minutes or 2 hours Clock hands for time display Switching status display SY 269 h 1 channel Without power reserve Synchronised with mains Switching preselection Permanent O/OFF switch Simple summer/winter time correction 32 tappets included in delivery SY 269 g 2 channels Without power reserve Synchronised with mains 49 tappets included in delivery SU 289 h As SY 269 h, but: With power reserve (imh rechargeable battery) Quartz controlled SU 289 g 2 channels With power reserve (imh rechargeable battery) Quartz controlled 49 tappets included in delivery Product selection Program Daily program or weekly program umber of channels Power reserve Shortest switching time Programmable every 1 20 min or 2 h 5 min or 30 min 2 20 min or 2 h 5 min or 30 min 1 3 days 20 min or 2 h 5 min or 30 min 2 3 days 20 min or 2 h 5 min or 30 min Type of contact Changeover contact 2 Changeover contacts Changeover contact 2 Changeover contacts Operating voltage Type Article number 230 V AC S Y 269 h 2 690008 230 V AC S Y 269 g 2690033 230 V AC S U 289 h 2 890008 230 V AC S U 289 g 2 890033 http Additional technical data at: 44 www.theben.de/product/ Article number

TIME Analogue time switches Front panel installation/wall installation Technical data SY 269 h SY 269 g SU 289 h SU 289 g Operating voltage 230 V AC Frequency 50 Hz 50-60 Hz Installation type Front panel installation/wall installation Program Daily program or weekly program Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 10 A Max. switching capacity at 250 V AC, cos = 0.6 2 A Shortest switching time 20 min or 2 h Programmable every 5 min or 30 min Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +55 C 2 Accessories Quick fastening 72 x 72 Art.o.: 9070071 Details Page 229 Scale drawings SY 269 h, SY 269 g, SU 289 h, SU 289 g 69 54 72 16 104 66 72 65 25 Connection example SY 269 h, SU 289 h SY 269 g, SU 289 g C1 1 2 3 7 8 C1 C2 1 2 3 4 5 6 7 8 httpadditional technical data at: www.theben.de/product/ Article number 45

Analogue time switches Front panel installation/wall installation TIME Analogue time switches wall installation tappets 2 TM 179 h SU 189 hw Description TM 179 h Analogue time switch with 60 minute program 1 channel Without power reserve Synchronised with mains Tappets Shortest switching time: 75 seconds Switching preselection Switching status display 6 tappets included in delivery SU 189 hw Analogue time switch with daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts) With power reserve (imh rechargeable battery) Quartz controlled Tappets and turning segments Shortest switching time: 30 minutes (12 hours for the 1/2 day OFF function) Switching status display 6 tappets included in delivery Product selection Program 60 minute program Daily program and 1/2 day OFF function umber of channels Power reserve Shortest switching time Programmable every 1 1.25 min 18.5 s 1 3 days 30 min/12 h 15 min/12 h Type of contact Changeover contact Changeover contact Operating voltage Type Article number 230 V AC TM 179 h 1 790008 230 V AC S U 189 hw 1 890108 http Additional technical data at: 46 www.theben.de/product/ Article number

TIME Analogue time switches Front panel installation/wall installation Technical data TM 179 h SU 189 hw Operating voltage 230 V AC Frequency 50 Hz 50-60 Hz Installation type Front panel installation/wall installation Program 60 minute program Daily program with 1/2 day OFF function Power reserve 3 days Max. switching capacity at 250 V AC, cos = 1 10 A Max. switching capacity at 250 V AC, cos = 0.6 2 A Shortest switching time 1.25 min 30 min/12 h Programmable every 18.5 s 15 min/12 h Time accuracy Synchronised with mains ± 1 s/day(quartz) Power consumption 1 VA Type of protection IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +55 C 2 Accessories Quick fastening 72 x 72 Art.o.: 9070071 Details Page 229 Scale drawings TM 179 h, SU 189 hw 72 54 69 16 104 66 72 65 25 Connection example TM 179 h SU 189 hw C1 1 2 3 7 8 24h 7d 1 2 3 4 5 6 7 8 httpadditional technical data at: www.theben.de/product/ Article number 47

Analogue time switches Wall installation/3-point mounting TIME Analogue time switch wall installation/3-point mounting 2 SU 285/1 T SU 285/2 T Description Common functions Analogue time switch with daily program With power reserve (exchangeable imh battery) Quartz controlled Tappets Shortest switching time: 20 minutes Clock hands for time display Switching status display Simple summer/winter time correction Control ED for battery change 32 tappets included in delivery SU 285/1 T 1 channel SU 285/2 T 2 channels Product selection Program Daily program umber of channels Power reserve Shortest switching time Programmable every 1 6 days 20 min 5 min 2 6 days 20 min 5 min Type of contact Changeover contact 2 Changeover contacts Operating voltage Type Article number 110/230 V AC S U 285/1 T 2 850008 110/230 V AC S U 285/2 T 2 850033 http Additional technical data at: 48 www.theben.de/product/ Article number

TIME Analogue time switches Wall installation/3-point mounting Technical data SU 285/1 T Operating voltage 110 V AC/230 V AC Frequency 50-60 Hz Program Daily program Power reserve 6 days Max. switching capacity at 250 V AC, cos = 1 6 A Max. switching capacity at 250 V AC, cos = 0.6 2 A Shortest switching time 20 min Programmable every 5 min Time accuracy ± 1 s/day(quartz) Power consumption 1 VA Type of protection IP 54 Protection class II in accordance with E 62,054-21 Ambient temperature 10 C +55 C SU 285/2 T 2 Scale drawings SU 285/1 T, SU 285/2 T Connection example SU 285/1 T SU 285/2 T 105 74 121,5 6,5 175 1 2 1a C1 3 4 5 1a C1 C2 3 4 5 6 7 8 84,5 101,5 httpadditional technical data at: www.theben.de/product/ Article number 49

Analogue time switches Plug-in TIME Analogue socket time switches switching segments 2 theben-timer 26 theben-timer 26 IP 44 theben-timer 27 Description Common functions Analogue plug-in timer 1 channel Without power reserve Synchronised with mains Use with earthed sockets (additional socket types upon request) Switching preselection Switching status display theben-timer 26 Daily program 96 switching segments Shortest switching time: 15 minutes theben-timer 26 IP 44 As theben-timer 26, but: Waterproof protection for damp locations and outdoor areas Transparent cover theben-timer 27 Weekly program 84 switching segments Shortest switching time: 2 hours Product selection Program Shortest switching time Programmable every Type of contact Operating voltage Type Article number theben-timer 26 0260030 Daily program 15 min 15 min O contact 230 V AC t heben-timer 26 IP 44 0260855 Weekly program 2 h 2 h O contact 230 V AC t heben-timer 27 0270930 http Additional technical data at: 50 www.theben.de/product/ Article number

1 18 19 16 20 24 2 3 8 7 4 6 5 TIME Analogue time switches Plug-in Technical data theben-timer 26 theben-timer 26 IP 44 theben-timer 27 Operating voltage 230 V AC Frequency 50 Hz Installation type Socket (plug-in) Program Daily program Weekly program Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 4 A Shortest switching time 15 min 2 h Programmable every 15 min 2 h Time accuracy Synchronised with mains Power consumption 0.8 VA Test approvals V Type of protection IP 20 IP 44 IP 20 Protection class I in accordance with E 60 730-1 Ambient temperature 10 C +55 C 40 C +55 C 10 C +55 C 2 Scale drawings Connection example 41 71 0 1 0 15 14 13 12 11 10 9 17 21 22 23 1 httpadditional technical data at: www.theben.de/product/ Article number 51

Analogue time switches Wall installation/di rail TIME Analogue cooling timers - tappets 2 FRI 77 h FRI 77 g-2 Description Common functions Analogue cooling timer with daily and short time program for defrosting Tappets Synchronised with mains Shortest switching time: 2 minutes / 1 hour 2 separate switching discs FRI 77 h 1 channel Wall-mounted 6 tappets included in delivery FRI 77 g 2 channels Wall-mounted 8 tappets included in delivery Optional delayed switching on of fan FRI 77 h-2 1 channel Drive with quick fastening for DI rail 6 tappets included in delivery FRI 77 g-2 As FRI 77 g, but: Drive with quick fastening for DI rail Product selection Type of contact Installation type Shortest switching time Programmable every Operating voltage Type Article number Changeover contact Wall-mounted 2 min/1 h 1 min/1 h 230 V AC F RI 77 h 0770008 2 Changeover contacts Wall-mounted 2 min/1 h 1 min/1 h 230 V AC F RI 77 g 0770033 Changeover contact Drive with quick fastening for DI rail 2 min/1 h 1 min/1 h 230 V AC F RI 77 h-2 0770802 2 Changeover contacts Drive with quick fastening for DI rail 2 min/1 h 1 min/1 h 230 V AC F RI 77 g-2 0770832 http Additional technical data at: 52 www.theben.de/product/ Article number

TIME Analogue time switches Wall installation/di rail Technical data FRI 77 h FRI 77 g FRI 77 h-2 FRI 77 g-2 Operating voltage 230 V AC Frequency 50 Hz Installation type Wall-mounted Drive with quick fastening for DI rail Program Daily and defrost program Max. switching capacity at 250 V AC, cos = 1 16 A Max. switching capacity at 250 V AC, cos = 0.6 2.5 A Shortest switching time 2 min/1 h Programmable every 1 min/1 h Time accuracy Synchronised with mains Power consumption 2.5 VA Test approvals V W Type of protection IP 20 IP 00 Protection class II in accordance with E 60 730-1 Ambient temperature 10 C +50 C 2 Scale drawings FRI 77 h-2, FRI 77 g-2 105 61 FRI 77 h-2, FRI 77 g-2 82 48 105 55 Connection example FRI 77 h, FRI 77 h-2 FRI 77 g, FRI 77 g-2 K1 1 2 3 7 8 K1 K2 1 2 3 4 5 6 7 8 httpadditional technical data at: www.theben.de/product/ Article number 53

TIME 54

Section overview TIME Time relay/hour counter Time relay Description Type Page Multi-function relay TM 345 M 56 3 Time relay with time switch function TM 345 B 56 Analogue hour counter Installation type Front plate size Type Page BZ 142-1 58 48 x 48 mm Front panel installation BZ 142-3 58 52 x 52 mm BZ 143-1 58 DI-rail 35 x 45 mm BZ 145 58 Digital hour counter Front panel installation 24 x 48 mm BZ 146 60 48 x 48 mm BZ 147 60 DI-rail 35 x 45 mm BZ 148 60 httpadditional technical data at: www.theben.de/product/ Article number 55

Time relay/hour counter Analogue TIME Time relay DI-rail TM 345 M TM 345 B 3 Description Common functions Electronic time relay Electronic time relay can be used universally for controlling automatic processes in machines, lighting, ventilation, heating, cupboards etc. Precise analogue time setting Multi-voltage input for all supply and control voltages, no jumpers or additional terminals are required ED to display the switching status TM 345 M Multi-function relay ocking rotary switch for the selection of time range as well as the following operating modes: - Response delay, without control contact - Wiper switch-on without control contact - Release delay with control contact - Pulse former with control contact - On/Off switching delay with control contact - Wiper switch On/Off with control contact - Time switch generator without control contact TM 345 B Time relay with time switch function Pulse and pause duration can be set independently of each other Product selection Type Article number T M 345 M 3450731 TM 345 B 3450730 http Additional technical data at: 56 www.theben.de/product/ Article number

TIME Time relay/hour counter Analogue Technical data TM 345 M TM 345 B Operating voltage 12-240 V AC/DC 24 240 V AC/24 V DC Frequency 50 60 Hz Width 1 module Power consumption 1.5 VA Type of contact Changeover contact Housing and insulation material High-temperature resistant, self-extinguishing thermoplast Switch output Potential free Electrical service life 10 5 operation cycles Mechanical service life < 10 5 operation cycles Fall back value of nominal input voltage < 10.8 V AC/DC (according with E 61812-1) Protection rating IP 20 Protection class II in accordance with E 60 730-1 Ambient temperature 20 C +60 C 3 Accessories Connection example Wall installation kit 17.5 mm TM 345 M TM 345 M TM 345 B Art.o.: 9070065 Details Page 230 S A1+ 15 B2 A1+ 15 B2 A1+ 15 18 16 A2-18 16 A2-18 16 A2- httpadditional technical data at: www.theben.de/product/ Article number 57

Time relay/hour counter Analogue TIME Analogue hour counter Front panel and DI rail BZ 142-1 BZ 142-3 BZ 145 3 Description BZ 142-1 Hour counter with synchronous power drive Versions for direct voltage with quartzcontrolled stepper motor Progress display Front panel devices with click-in or stretch clamp supports for walls up to a maximum of 10 mm thick Clamp or at plug connection 6.3 mm Front plate 48 x 48 mm size BZ 142-3 ike BZ 142-1, however: With plug-in base for wall installation (front panel kit required) Plug-in base with quick fastening for 35 mm DI rail Terminal screws Contact protection to comply with accident prevention regulation BGV A3 Housing colour: anthracite BZ 143-1 ike BZ 142-1, however: Front plate 52 x 52 mm size BZ 145 Hour counter Built in distributor device with quick fastening for 35 mm DI rail Top mounting with additional terminal box cover plate, sealable Control panel installation with assembly kit no. 9070001 Contact protection to comply with accident prevention regulation BGV A3 Captive terminal screws Product selection Counting range Installation type Front plate size Integrated part size Operating voltage Type Article number 230 V AC BZ 142-1 1420721 110 V AC B Z 142-1 110 V 1421721 99,999.99 hours without reset Front panel installation 48 x 48 mm 46 x 46 mm 230-240 V AC B Z 142-1 230 V 1420621 24 V AC B Z 142-1 24 V 1424721 BZ 142-3 1420723 230 V AC 52 x 52 mm 46 x 46 mm BZ 143-1 1430721 DI-rail 35 x 45 mm 35 x 45 mm 230 V AC B Z 145 1450000 24-48 V DC B Z 145 24 V 1459024 http Additional technical data at: 58 www.theben.de/product/ Article number

TIME Time relay/hour counter Analogue Technical data BZ 142-1 BZ 142-1 110 V BZ 142-1 240 V BZ 142-1 24 V BZ 142-3 BZ 143-1 BZ 145 BZ 145 24 V Operating voltage 230 V AC 110 V AC 230-240 V AC 24 V AC 230 V AC 24-48 V DC Frequency 50 Hz 60 Hz 50 Hz Width 2 modules Installation type Front panel installation DI-rail Protection rating Front frame IP 65 IP 65 Protection class II in accordance with E 60,335-1 Ambient temperature 20 C +70 C 10 C +70 C 3 Accessories Clamping bracket BZ For BZ 142-1, BZ 143-1 Art.o.: 9070043 Details Page 231 Baf e 72 x 72 for BZ For BZ 142-1 Art.o.: 9070074 Details Page 231 Front panel kit BZ 142-3 For BZ 142-3 Art.o.: 9070075 Details Page 231 Wall installation kit 35 mm For BZ 145 Art.o.: 9070064 Details Page 230 Baf e 55 x 55 for BZ For BZ 142-1 Art.o.: 9070041 Details Page 231 Plug-in base BZ For BZ 142-3 Art.o.: 9070042 Details Page 231 Scale drawings BZ 142-1 BZ 142-3 BZ 143-1 Ø 50 Ø 50 Ø 50 45 48 59 55,5 45 48 45 52 39 5 30 48,6 5 39 5 httpadditional technical data at: www.theben.de/product/ Article number 59

Time relay/hour counter Digital TIME Digital hour counter Front panel and DI rail BZ 146 BZ 147 BZ 148 3 Description Common functions 7-digit high-contrast CD display Onscreen progress display Digital hour counter EEPROM memory ensures reliable elapsed time counting, even during loss of power BZ 146 Control panel installation Terminal screws Tension clamp brackets for walls up to 5mm thick Quartz controlled version Installation cutout 22 mm x 45 mm BZ 147 ike BZ 146, however: Installation cutout 45 mm x 45 mm BZ 148 Built in distributor device with quick fastening for 35 mm DI rail Surface mounting with additional terminal box cover plate option Captive terminal screws Product selection Counting range Installation type Front plate size Integrated part size Operating voltage Type Article number 99,999.99 hours without reset 24 x 48 mm 22 x 45 mm 110-240 V AC BZ 146 1460000 Front panel installation 48 x 48 mm 45 x 45 mm 110-240 V AC BZ 147 1470000 12-24 V DC B Z 147 24 V 1479000 DI-rail 35 x 45 mm 35 x 45 mm 24-240 V AC B Z 148 1480000 Technical data BZ 146 BZ 147 BZ 147 24V BZ 148 Operating voltage 110-240 V AC 12-24 V DC 24-240 V AC Frequency 50 60 Hz Width 2 modules Installation type Front panel installation DI-rail Protection rating IP 65 IP 65 (front side) Protection class II in accordance with E 61010 Ambient temperature 30 C +70 C 10 C +70 C http Additional technical data at: 60 www.theben.de/product/ Article number

TIME Time relay/hour counter Digital Accessories Clamping bracket BZ For BZ 147 Art.o.: 9070043 Details Page 231 Wall installation kit 35 mm For BZ 148 Art.o.: 9070064 Details Page 230 3 Scale drawings BZ 146 BZ 147 48 0,2 45 +0,6 24 0,2 37,3 45 22 1 2 3 4 22,2 +0,3 3 37,3 48 1 2 3 4 45 3 45,2 +0,3 Connection example BZ 146, BZ 147 BZ 148 (+) ( ) 1 2 3 4 (+) ( ) 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 61

IGHT http Additional technical data at: www.theben.de/product/ Article number 62

Section overview IGHT Presence detectors 230 V Installation type Detection area at 3.0 m installation height - Sitting - Detection area at 3.0 m installation height - Walking - Channel Function mode Protection rating Type Page Ceiling 20 m² ( 4.5 x 4.5 m) 49 m² ( 7.0 x 7.0 m) ight Switching IP 54 Presenceight 360 64 Ceiling 20 m² 5.0 m 360 ) 113 m² 12.0 m 360 ) Ceiling 25 m² ( 5.0 x 5.0 m) 49 m² ( 7.0 x 7.0 m) ight Switching IP 41 SPHIX 104-360 AP 66 ight Presence Switching IP 41 SPHIX 104-360/2 AP 66 ight Switching IP 41 SPHIX 104-360 66 ight Presence Switching IP 41 SPHIX 104-360/2 66 ight Presence Switching IP 40 compact of ce 68 ight 1 10 V Dimming IP 40 compact of ce DIM 70 4 Ceiling 90 m² ( 20 x 4.5 m) 135 m² ( 30 x 4.5 m) compact passage 72 ight Presence Switching IP 40 45 m² ( 10 x 4.5 m) 68 m² ( 15 x 4.5 m) compact passimo 74 ight Presence Switching IP 40 ECO-IR 360A 76 Ceiling 49 m² ( 7.0 x 7.0 m) 81 m² ( 9.0 x 9.0 m) Ceiling 49 m² ( 7.0 x 7.0 m) 81 m² ( 9.0 x 9.0 m) ight Presence Switching IP 40 ECO-IR 360C T 78 2 x ight Switching IP 40 ECO IR DUA C T 80 ight Presence PlanoCentro 101-EWH 82 PlanoCentro 000-EWH 82 Switching IP 40 ight Presence PlanoCentro 101-UWH 82 PlanoCentro 000-UWH 82 Wall 28 m² 7.0 m 180 ) 100 m² 16.0 m 180 ) ight Switching IP 54 Presenceight 180 86 Wall 32 m² 8.0 m 180 ) 100 m² 16.0 m 180 ) ight Presence Switching IP 40 ECO-IR 180A 88 24 V Ceiling 25 m² ( 5.0 x 5.0 m) 49 m² ( 7.0 x 7.0 m) ight Presence Switching IP 40 compact of ce 24V 90 ight 0 10 V Switching IP 40 compact of ce 24V ux 92 Ceiling 90 m² ( 20 x 4.5 m) 135 m² ( 30 x 4.5 m) ight Presence Switching IP 40 compact passage 24V 94 Ceiling 49 m² ( 7.0 x 7.0 m) 81 m² ( 9.0 x 9.0 m) ight Presence Switching IP 40 ECO-IR 360-24V 96 Wall 32 m² 8.0 m 180 ) 100 m² 16.0 m 180 ) ight Presence Switching IP 40 ECO-IR 180A-24V 98 httpadditional technical data at: www.theben.de/product/ Article number 63

Presence detectors 230 V IGHT Presenceight 360 Description 4 Passive infrared presence detector (PIR) Square detection area Ceiling installation IP 54 protection rating for installation in wet zones Mixed light measurement ight switch output (relay, 230 V) Automatic lighting control ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer Can be con gured remotely The pulse function is for controlling a staircase timer The presence detector has a mixed light measurement and is suitable for switching the following types of lamp: Flourescent lamps (F/P), halogen and incandescent lamps The square detection range from Presenceight 360 allows accurate and simple planning Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) Presenceight 360 2000000 Ceiling installation ight 230 V AC pure black, (similar to RA 9005) Presenceight 360 BK 2000800 Silver (similar to RA 9006) Presenceight 360 SR 2000801 further colours on request Technical data Presenceight 360 Operating voltage 230 V AC Frequency 50 Hz Setting range 10 1500 lx Recommended installation height 2 3 m ight switch-off delay Impulse (0.5 s), 10 s 20 min ight contact type Relay 230 V Resistive load 1400 VA Incandescent and halogen lamp load 1200 W Compact and ourescent lamps 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Ambient temperature 20 C +50 C Protection rating IP 54 http Additional technical data at: 64 www.theben.de/product/ Article number

4 IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0m ± 0.5 m B C 3 m 20 m² 4.5 m x 4.5 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m 4 Accessories QuickSafe Art.o.: 9070531 Details Page 233 QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 Surface frame Presenceight Art.o.: 9070513 Details Page 232 Scale drawings 86 40,5 70 60 19,5 27 86 48 45,7 26,4 40 56 11 Connection example Presenceight Presenceight Presenceight httpadditional technical data at: www.theben.de/product/ Article number 65

Presence detectors 230 V IGHT SPHIX 104 SPHIX 104-360/2 SPHIX 104-360 AP 4 Description Common functions Passive infrared presence detector (PIR) ighting control with adjustable light threshold value and adjustable switch-off delay Teach-in of current brightness value possible via remote control Additional impulse function can be selected for combination with staircase timer (EPA), building automation or PC Master/slave function: Up to ten detectors to expand detection area. Test function for checking detection area Zero-cross switching SPHIX 104-360 1 channel (light) Ceiling installation Automatic lighting control based on presence and brightness Detection range can be limited using three enclosed segments Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Instant start-up possible via factory preset Push-button or switch options for manual switching Screwless terminals for quick installation SPHIX 104-360/2 2 channels 2. Relay for HVAC control, presence dependent HVAC control with programmable switchon delay and switch-off delay SPHIX 104-360 AP 1 channel SPHIX 104-360/2 AP 2 channels 2. Relay for HVAC control, presence dependent HVAC control with programmable switchon delay and switch-off delay Product selection Installation type Channel Operating voltage Type Article number Surface mounted on ceiling Ceiling installation ight 230 V AC SPHIX 104-360 AP 1040360 ight Presence 230 V AC SPHIX 104-360/2 AP 1040362 ight 230 V AC SPHIX 104-360 1040370 ight Presence 230 V AC SPHIX 104-360/2 1040372 Technical data SPHIX 104-360 AP SPHIX 104-360/2 AP SPHIX 104-360 SPHIX 104-360/2 Operating voltage 230 V AC Frequency 50 60 Hz Setting range 10 2000 lx Switching capacity light 16 A (at 230 V AC, cos = 1) 8 A (at 230 V AC, cos = 1) Switching capacity Presence 5 A (at 250 V AC or 30 V DC) 3 A (at 250 V AC or 30 V DC) Recommended installation height 2.5 3.5 m ight switch-off delay 1 s 20 min Presence switch-off delay 1 120 min 1 120 min http Additional technical data at: 66 www.theben.de/product/ Article number

IGHT Presence detectors 230 V SPHIX 104-360 AP SPHIX 104-360/2 AP SPHIX 104-360 SPHIX 104-360/2 Presence switch-on delay 0 60 min 0 60 min Incandescent lamp load 2000 W 1800 W Fluorescent tubes ➀ not corrected, series-corrected 900 VA Flourescent lamps ➁ 400 VA Compact uorescent lamps ➁ 4 x 7 W, 3 x 11 W, 3 x 15 W, 3 x 20 W, 3 x 23 W Ambient temperature 10 C +55 C Protection class II in accordance with E 60,669-1 Protection rating IP 41 ➀ conventional ballast, ➁ electronic ballast 4 Detection range Accessories 360 2,5 m SPHIX RC 104 pro Art.o.: 9070536 Details Page 235 Additional accessories SPHIX RC 104, Details Page 235 RC lter, Details Page 232 6 m Walking Sitting Installation height 2.5 m Scale drawings 110 28 43 72 110 28 25 35 90 110 72 110 90 Connection example Ext Ext Ext Ext M/S M/S M/S M/S M/S M/S M M/S M/S P1 P2 httpadditional technical data at: www.theben.de/product/ Article number 67

Presence detectors 230 V IGHT compact of ce Description 4 Passive infrared presence detector (PIR) Square detection area Mixed light measurement The square detection area allows accurate and simple planning ight switch output (relay, 230 V) Presence switch output (relay, oating) Automatic control of lighting and HVAC as well as room monitoring function ighting control with light threshold value and self-learning switch-off delay Choice of fully or semi automatic operation Sensor or switch options for manual switching Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Device can be connected as master or slave Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus A maximum of 10 detectors can be switched at the same time Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact of ce 2010000 Ceiling installation ight Presence 230 V AC pure black, (similar to RA 9005) compact of ce BK 2010800 Silver (similar to RA 9006) compact of ce SR 2010801 further colours on request Technical data compact of ce Operating voltage Frequency Setting range Recommended installation height ight switch-off delay Presence switch-off delay Presence switch-on delay ight contact type 230 V AC 50 Hz 10 1500 lx 2 3 m Impulse (0.5 s), 10 s 20 min 10 s 120 min 0 s 10 min Relay 230 V Resistive load Incandescent and halogen lamp load Compact and ourescent lamps Presence contact type 1400 VA 1200 W 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Floating relay Switching capacity Presence 50 W (220 V DC), 50 VA (250 V AC) minimal 0.5 mv/10 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 68 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0 m ± 0.5 m B C 3 m 25 m² 5.0 m x 5.0 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings 102,5 48 70 60 33 102,5 40 4 56 11 Connection example httpadditional technical data at: www.theben.de/product/ Article number 69

Presence detectors 230 V IGHT compact of ce DIM Description 4 Passive infrared presence detector (PIR) Square detection area Mixed light measurement The square detection area allows accurate and simple planning ight switching output (relay, 230 V) and 1 10 V interface Automatic lighting control with constant light control Choice of fully or semi automatic operation Possible connection of sensor for manual switching and dimming Brightness threshold, self-learning switchoff delay and standby time are adjustable Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The standby time guarantees a minimum brightness and provides for a sense of security in hospital and care environments as the lighting does not switch off when areas are unoccupied but remains in standby mode for the set time. Device can be connected as master or slave Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus A maximum of 10 detectors can be switched at the same time Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact of ce DIM 2010001 Ceiling installation ight 1 10 V 230 V AC pure black, (similar to RA 9005) compact of ce DIM BK 2010803 Silver (similar to RA 9006) compact of ce DIM SR 2010804 further colours on request Technical data compact of ce DIM Operating voltage 230 V AC Frequency 50 Hz Setting range 10 1500 lx Recommended installation height 2 3 m ight switch-off delay: 10 s 20 min ight contact type Relay 230 V Resistive load 1400 VA Incandescent and halogen lamp load 1200 W Compact and ourescent lamps 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 70 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0 m ± 0.5 m B C 3 m 25 m² 5.0 m x 5.0 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings 102,5 48 70 60 33 102,5 40 4 56 11 Connection example 1 10 V 1 10 V httpadditional technical data at: www.theben.de/product/ Article number 71

Presence detectors 230 V IGHT compact passage Description 4 Passive infrared presence detector (PIR) Rectangular detection range for corridors Mixed light measurement Automatic control of lighting and HVAC as well as room monitoring function ight switch output (relay, 230 V) Presence switch output (relay, oating) Choice of fully or semi automatic operation Sensor or switch options for manual switching The rectangular detection area covers an area of up to 30 metres in corridors and enables safe and simple planning Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically Device can be connected as master or slave ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The switch-on delay prevents instantaneous switch on. The contact only closes on completion of the switch-on delay The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus A maximum of 10 detectors can be switched at the same time Product selection Installation typec Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact passage 2010090 Ceiling installation ight Presence 230 V AC pure black, (similar to RA 9005) compact passage BK 2010806 Silver (similar to RA 9006) compact passage SR 2010807 further colours on request Technical data compact passage Operating voltage Frequency Setting range Recommended installation height ight switch-off delay Presence switch-off delay Presence switch-on delay ight contact type 230 V AC 50 Hz 10 1500 lx 2 3.5 m Impulse (0.5 s), 10 s 20 min 10 s 120 min 0 s 10 min Relay 230 V Resistive load Incandescent and halogen lamp load Compact and ourescent lamps Presence contact type 1400 VA 1200 W 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Floating relay Switching capacity Presence 50 W (220 V DC), 50 VA (250 V AC) minimal 0.5 mv/10 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 72 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (rectangular) Installation height (A) Head on to (r) Diagonally (t) 2 m 56 m² 16 m x 3.5 m ± 1 m 105 m² 30 m x 3.5 m ± 1 m A ux 2.5 m 72 m² 18 m x 4.0 m ± 1 m 120 m² 30 m x 4.0 m ± 1 m 3 m 90 m² 20 m x 4.5 m ± 1 m 135 m² 30 m x 4.5 m ± 1 m r t 3.5 m 100 m² 20 m x 5.0 m ± 1 m 150 m² 30 m x 5.0 m ± 1 m r t 4 Accessories QuickSafe Art.o.: 9070531 Details Page 233 QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings 40 44 102,5 26,5 19 25 48 70 60 102,5 40,5 75 4 56 11 33 63 Connection example httpadditional technical data at: www.theben.de/product/ Article number 73

Presence detectors 230 V IGHT compact passimo Description 4 Passive infrared presence detector (PIR) Rectangular detection area for storage areas with clear demarcation vertically below the presence detector Mixed light measurement Automatic control of lighting and HVACas well as room monitoring function ighting control with light threshold value and self-learning switch-off delay ight switch output (relay, 230 V) Presence switch output (relay, oating) Choice of fully or semi automatic operation Sensor or switch options for manual switching Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically Device can be connected as master or slave Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The switch-on delay prevents instantaneous switch on. The contact only closes on completion of the switch-on delay The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus A maximum of 10 detectors can be switched at the same time Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact passimo WH 2010080 * Ceiling installation ight Presence 230 V AC pure black, (similar to RA 9005) compact passimo BK 2010809 * Silver (similar to RA 9006) compact passimo SR 2010810 * further colours on request * Available May 2010 Technical data compact passimo Operating voltage Frequency Setting range Recommended installation height ight switch-off delay Presence switch-off delay Presence switch-on delay ight contact type 230 V AC 50 Hz 10 1500 lx 2 3.5 m Impulse (0.5 s), 10 s 20 min 10 s 120 min 0 s 10 min Relay 230 V Resistive load Incandescent and halogen lamp load Compact and ourescent lamps Presence contact type 1400 VA 1200 W 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Floating relay Switching capacity Presence 50 W (220 V DC), 50 VA (250 V AC) minimal 0.5 mv/10 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 74 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (rectangular) Installation height (A) Head on to (r) Diagonally (t) 2 m 28 m² 8 m x 3.5 m ± 1 m 53 m² 15 m x 3.5 m ± 1 m A ux r t 2.5 m 36 m² 9 m x 4.0 m ± 1 m 60 m² 15 m x 4.0 m ± 1 m 3 m 45 m² 10 m x 4.5 m ± 1 m 68 m² 15 m x 4.5 m ± 1 m r t 3.5 m 50 m² 10 m x 5.0 m ± 1 m 75 m² 15 m x 5.0 m ± 1 m Accessories 4 QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings 40 44 102,5 26,5 19 25 48 70 60 102,5 40,5 75 4 56 11 33 63 Connection example httpadditional technical data at: www.theben.de/product/ Article number 75

Presence detectors 230 V IGHT ECO-IR 360A Description 4 Passive infrared presence detector (PIR) Square detection area Genuine daylight measurement The square detection area allows accurate and simple planning ight switch output (relay, 230 V) Presence switch output (relay, oating) Automatic control of lighting and HVAC ighting control with light threshold value and self-learning switch-off delay HVAC control with separate switch-off delay The presence detector has "Genuine light measurement" and is only suitable for switching uorescent lamps (F/P). Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence. The parameters are set via the potentiometer Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR 360A 2020000 Ceiling installation ight Presence 230 V AC pure black, (similar to RA 9005) ECO-IR 360A BK 2020806 Silver (similar to RA 9006) ECO-IR 360A SR 2020807 further colours on request Technical data ECO-IR 360A Operating voltage 230 V AC Frequency 50 Hz Setting range 50 1600 lx Recommended installation height 2 3.5 m ight switch-off delay 2 min 15 min Presence switch-off delay 10 60 min ight contact type Relay 230 V Compact and ourescent lamps 12 x (1 x 58 W), 6 x (2 x 58 W), 18 x (1 x 36 W), 9 x (2 x 36 W), 18 x (smaller than 36 W) Maximum switching capacity 1400 VA Presence contact type Floating relay Switching capacity Presence 100 W (24 V DC), 460 VA (230 V AC), Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 76 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m B C 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m 4.0 m 121 m² 11.0 m x 11.0 m ± 1 m 4 Accessories QuickFix round cover Art.o.: 9070517 Details Page 233 QuickFix square cover Art.o.: 9070518 Details Page 232 Surface frame ECO-IR 360 Art.o.: 9070512 Details Page 232 Additional accessories s. p. 232 QuickFix concrete round cover Details Page 232 QuickFix concrete square cover Details Page 233 QuickFix concrete ushmounted box Details Page 233 QuickFix concrete ushmounted housing Details Page 233 QuickSafe Details Page 233 Scale drawings 87 4 48 70 60 66,5 46,3 21,3 4 56 11 35,5 37,5 95 22 84,5 Connection example httpadditional technical data at: www.theben.de/product/ Article number 77

Presence detectors 230 V IGHT ECO-IR 360C T Description 4 Passive infrared presence detector (PIR) Square detection area Genuine daylight measurement The square detection area allows accurate and simple planning ight switch output (relay, 230 V) Presence switch output (relay, oating) Automatic control of lighting and HVAC as well as room monitoring function ighting control with light threshold value and self-learning switch-off delay Choice of fully or semi automatic operation Sensor or switch options for manual switching Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Inrush current limitation for EB Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The presence detector has "Genuine light measurement" and is only suitable for switching uorescent lamps (F/P). The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Device can be connected as master or slave Test operation mode checks the detection area and installation A maximum of 10 detectors can be switched at the same time Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR 360C T 2020400 Ceiling installation ight Presence 230 V AC pure black, (similar to RA 9005) ECO-IR 360C T BK 2020812 Silver (similar to RA 9006) ECO-IR 360C T SR 2020813 further colours on request Technical data ECO-IR 360C T Operating voltage 230 V AC Frequency 50 Hz Setting range 10 1500 lx Recommended installation height 2 3.5 m ight switch-off delay: Impulse (0.5 s), 10 s 20 min Presence switch-off delay 10 s 120 min Presence switch-on delay 0 s 10 min ight contact type Relays 230 V, inrush current limitation Compact and ourescent lamps 16 x (1 x 58 W), 8 x ( 2 x 58 W), 24 x (1 x 36 W), 12 x (2 x 36 W), 24 x (smaller than 36 W) Maximum switching capacity 1400 VA Presence contact type Floating relay Switching capacity Presence 100 W (50 V DC), 460 VA (230 V AC) minimal 10 V/100 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 78 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m B C 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m 4.0 m 121 m² 11.0 m x 11.0 m ± 1 m 9.0 m 361 m² 19.0 m x 19.0 m ± 1 m 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 Additional accessories s. p. 232 QuickFix round cover Details Page 233 QuickFix square cover Details Page 233 QuickFix concrete ush-mounted box Details Page 233 QuickSafe Details Page 233 Surface frame ECO-IR 360 Details Page 232 Scale drawings 87 4 48 70 60 66,5 46,3 21,3 4 56 11 35,5 37,5 95 22 84,5 Connection example httpadditional technical data at: www.theben.de/product/ Article number 79

Presence detectors 230 V IGHT ECO-IR DUA-C T Description 4 Passive infrared presence detector (PIR) Square detection area Genuine daylight measurement The square detection area allows accurate and simple planning Two light switch outputs (relay, 230 V) Automatic control of two lighting zones Two light switch outputs (relay, 230 V) ighting control with two light threshold values and self-learning switch-off delay Choice of fully or semi automatic operation Sensor or switch options for manual switching Inrush current limitation for EB Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The presence detector has double "Genuine daylight measurement" and is only suitable for switching uorescent lamps (F/P). Device can be connected as master or slave Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus A maximum of 10 detectors can be switched at the same time Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR DUA-C T 2020401 Ceiling installation 2 x ight 230 V AC pure black, (similar to RA 9005) ECO-IR DUA-C T BK 2020815 Silver (similar to RA 9006) ECO-IR DUA-C T SR 2020816 further colours on request Technical data ECO-IR DUA-C T Operating voltage 230 V AC Frequency 50 Hz Setting range 10 1500 lx Recommended installation height 2 3.5 m ight switch-off delay 10 s 20 min ight contact type Relays 230 V, inrush current limitation Maximal load 1400 VA (total both contacts) Compact and ourescent lamps 16 x (1 x 58 W), 8 x ( 2 x 58 W), 24 x (1 x 36 W), 12 x (2 x 36 W), 24 x (smaller than 36 W) Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 80 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m B C 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m 4.0 m 121 m² 11.0 m x 11.0 m ± 1 m 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 Additional accessories s. p. 232 QuickFix round cover Details Page 233 QuickFix square cover Details Page 233 QuickFix concrete ush-mounted box Details Page 233 QuickSafe Details Page 233 Surface frame ECO-IR 360 Details Page 232 Scale drawings 87 4 48 70 60 66,5 46,3 21,3 4 56 11 35,5 37,5 95 22 84,5 Connection example httpadditional technical data at: www.theben.de/product/ Article number 81

Presence detectors 230 V IGHT PlanoCentro Description 4 Common functions Passive infrared presence detector (PIR) Square 360 detection range allows accurate and simple planning Flush design Exchangeable cover according to shape, colour and material Mixed light measurement Presence and brightness-dependent control for lighting and HVAC systems Choice of fully or semi-automatic lighting control Connection option for sensors or switches for manual switching with automatic recognition Adjustable sensitivity Can be con gured remotely 6 prede ned basic settings on presence detector ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer Presence output with switch-on delay and switch-off delay Parameters can be selected for subsequent changes Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically Test operation mode checks the detection range and con guration A maximum of 10 detectors can be switched at the same time PlanoCentro 101-EWH For ceiling installation (false ceilings) With installation for false ceilings and cover PlanoCentro 000-EWH Slave-Version for PlanoCentro 101-EWH Just to be used with PlanoCentro 101-EWH as Master PlanoCentro 101-UWH For ush-mounting (concrete ceiling) With metal installation frame for screwed xing in wooden ceilings or in ush-mounted sockets, incl. cover PlanoCentro 000-UWH Slave-Version for PlanoCentro 101-EWH Just to be used with PlanoCentro 101-EWH as Master Product selection Installation type Channel Function Colour Type Article number Ceiling mounting with installation frame Ceiling mounting ( ushmounting for concrete ceiling) * Available May 2010 ight Presence Master Slave ight Presence Master pure white, (similar to RA 9010) PlanoCentro 101-EWH 2030102 pure black, (similar to RA 9005) PlanoCentro 101-EBK 2030103 Silver (similar to RA 9006) PlanoCentro 101-ESR 2030104 pure white, (similar to RA 9010) PlanoCentro 000-EWH 2040102 * pure black, (similar to RA 9005) PlanoCentro 000-EBK 2040103 * Silver (similar to RA 9006) PlanoCentro 000-ESR 2040104 * pure white, (similar to RA 9010) PlanoCentro 101-UWH 2030202 pure black, (similar to RA 9005) PlanoCentro 101-UBK 2030203 Silver (similar to RA 9006) PlanoCentro 101-USR 2030204 pure white, (similar to RA 9010) PlanoCentro 000-UWH 2040202 * Slave pure black, (similar to RA 9005) PlanoCentro 000-UBK 2040203 * Silver (similar to RA 9006) PlanoCentro 000-USR 2040204 * further colours on request http Additional technical data at: 82 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Technical data PlanoCentro Operating voltage 230 V AC Frequency 50 Hz Setting range 5 2000 lx Recommended installation height 2 3.5 m ight switch-off delay Impulse, 10 s 60 min Presence switch-off delay 10 s 120 min Presence switch-on delay 0 s 10 min ight contact type Relays 230 V/10 A Maximum switching capacity 2300 W (at cos = 1 resistive load), 1150 W (at cos = 0.5) Compact and ourescent lamps 20 x 54 W, 25 x 39 W, 10 x 2 W, 54 x 15 W, 2 x 39 W Presence contact type Floating relay Switching capacity Presence 60 W (220 V DC), 62.5 VA (250 V AC) minimal 0.5 mv/10 ma Ambient temperature +0 C +50 C Protection rating IP 40 4 Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m B C 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m Accessories SendoPro 868-A Art.o.: 9070675 Details Page 234 SendoClic Art.o.: 9070690 Details Page 234 Additional accessories Junction casing, 115 x 115 x 100 mm Details Page 233 httpadditional technical data at: www.theben.de/product/ Article number 83

Presence detectors 230 V IGHT PlanoCentro Scale drawings PlanoCentro ceiling mounting 112 5 89 4 83 78 5 100 x 100 PlanoCentro Ceiling mounting ( ush-mounting for concrete ceiling) 6 89 123 118 83 70 62 107 http Additional technical data at: 84 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Connection example PlanoCentro 101-EWH, PlanoCentro 101-UWH PlanoCentro 101-x-230V A P P S1 H1 H2 4 PlanoCentro 101-EWH, PlanoCentro 000-EWH, PlanoCentro 101-UWH, PlanoCentro 000-UWH PlanoCentro 101-x-230V Master PlanoCentro 000-x-230V Slave A P P S1 H1 H2 A P P S1 H1 H2 httpadditional technical data at: www.theben.de/product/ Article number 85

Presence detectors 230 V IGHT Presenceight 180 Description 4 Passive infrared presence detector (PIR) Detection area 180 Wall installation IP 54 protection rating for installation in wet zones Mixed light measurement ight switch output (relay, 230 V) Automatic lighting control ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer Can be con gured remotely The pulse function is for controlling a staircase timer The presence detector has a mixed light measurement and is suitable for switching the following types of lamp: Flourescent lamps (F/P), halogen and incandescent lamps Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) Presenceight 180 2000050 Wall installation ight 230 V AC pure black, (similar to RA 9005) Presenceight 180 BK 2000803 Silver (similar to RA 9006) Presenceight 180 SR 2000804 further colours on request Technical data Presenceight 180 Operating voltage 230 V AC Frequency 50 Hz Setting range 10 1500 lx Recommended installation height 1.6 2.2 m ight switch-off delay Impulse (0.5 s), 10 s 20 min ight contact type Relay 230 V Resistive load 1400 VA Incandescent and halogen lamp load 1200 W Compact and ourescent lamps 10 x (1 x 58 W), 5 x (2 x 58 W), 16 x (1 x 36 W), 8 x (2 x 36 W), 16 x (smaller than 36 W) Ambient temperature 20 C +50 C Protection rating IP 54 http Additional technical data at: 86 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Detection area (semicircular) Installation height (A) Sitting (B) Walking (C) 2.2 2.2 m 25 m² 7.0 m x 3.5 m 100 m² Ø 16 m A B C Accessories 4 QuickSafe Art.o.: 9070531 Details Page 233 QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 Surface frame Presenceight Art.o.: 9070513 Details Page 232 Scale drawings 86 40,5 70 60 15 32 86 48 36,3 26,4 40 4 56 11 Connection example Presenceight Presenceight Presenceight httpadditional technical data at: www.theben.de/product/ Article number 87

Presence detectors 230 V IGHT ECO-IR 180A Description 4 Passive infrared presence detector (PIR) Detection area 180 Genuine daylight measurement Automatic control of lighting and HVAC ighting control with light threshold value and self-learning switch-off delay HVAC control with separate switch-off delay The presence detector has "Genuine light measurement" and is only suitable for switching uorescent lamps (F/P). Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The parameters are set via the potentiometer Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR 180A 2020050 Wall installation ight Presence 230 V AC pure black, (similar to RA 9005) ECO-IR 180A BK 2020809 Silver (similar to RA 9006) ECO-IR 180A SR 2020810 further colours on request Technical data ECO-IR 180A Operating voltage 230 V AC Frequency 50 Hz Setting range 50 1600 lx Recommended installation height 1.6 2.2 m ight switch-off delay 2 min 15 min Presence switch-off delay 10 60 min ight contact type Relay 230 V Compact and ourescent lamps 12 x (1 x 58 W), 6 x (2 x 58 W), 18 x (1 x 36 W), 9 x (2 x 36 W), 18 x (smaller than 36 W) Maximum switching capacity 1400 VA Presence contact type Relay Switching capacity Presence 100 W (24 V DC), 460 VA (230 V AC), Ambient temperature +0 C +50 C Protection rating IP 40 Detection area (semicircular) Installation height (A) Sitting (B) Walking (C) 2.2 2.2 m 32 m² 8 m x 4 m 100 m² Ø 16 m A B C http Additional technical data at: 88 www.theben.de/product/ Article number

IGHT Presence detectors 230 V Accessories QuickSafe Art.o.: 9070531 Details Page 233 Surface frame ECO-IR 180 Art.o.: 9070511 Details Page 231 4 Scale drawings 85 48 70 60 85 46,3 21,3 4 56 11 35 45 80 70 Connection example ECO-IR 180A ECO-IR 180A httpadditional technical data at: www.theben.de/product/ Article number 89

Presence detectors 24 V IGHT compact of ce 24V Description 4 Passive infrared presence detector (PIR) Square detection area Mixed light measurement The square detection area allows accurate and simple planning ight switch output (relay, oating) Presence switch output (relay, oating) Automatic control of lighting and HVAC as well as room monitoring function ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact of ce 24V 2014000 Ceiling installation ight Presence 24 V AC/DC pure black, (similar to RA 9005) compact of ce 24V BK 2014800 Silver (similar to RA 9006) compact of ce 24V SR 2014801 further colours on request Technical data compact of ce 24V Operating voltage 24 V AC/DC Setting range 10 1500 lx Recommended installation height 2 3 m ight switch-off delay Impulse (0.5 s), 10 s 20 min Presence switch-off delay 10 s 120 min Presence switch-on delay 0 s 10 min ight contact type Floating relay Presence contact type Floating relay Switching capacity Presence/ight 50 W (24 V AC/DC), 460 VA (230 V AC),, minimal 1 V/1 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 90 www.theben.de/product/ Article number

IGHT Presence detectors 24 V Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0 m ± 0.5 m B C 3 m 25 m² 5.0 m x 5.0 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings 102,5 48 70 60 33 102,5 40 4 56 11 Connection example httpadditional technical data at: www.theben.de/product/ Article number 91

Presence detectors 24 V IGHT compact of ce 24V ux Description 4 Passive infrared presence detector (PIR) Square detection area Mixed light measurement The square detection area allows accurate and simple planning ight switch output (relay, oating) Automatic lighting control as well as analogue value output of measured brightness ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer Analogue output 0 10 V for brightness inear or logarithmic output of brightness Can be used as light sensor for PC controls The analogue output exports the brightness measured by the internal sensor as an analogue signal. The output of the analogue signal can either be linear or logarithmic to the measured brightness. The output functions independently from the presence detector Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus Product selection Installation typec Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) compact of ce 24V ux 2014001 Ceiling installation ight 0 10 V 24 V AC/DC pure black, (similar to RA 9005) compact of ce 24V ux BK 2014803 Silver (similar to RA 9006) compact of ce 24V ux SR 2014804 further colours on request Technical data compact of ce 24V ux Operating voltage 24 V AC/DC Setting range 10 1500 lx Recommended installation height 2 3 m ight switch-off delay Impulse (0.5 s), 10 s 20 min ight contact type Floating relay Analogue output 0 10 V DC Ambient temperature +0 C +50 C Protection rating IP 40 Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0 m ± 0.5 m B C 3 m 25 m² 5.0 m x 5.0 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m http Additional technical data at: 92 www.theben.de/product/ Article number

IGHT Presence detectors 24 V Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 4 Scale drawings 102,5 48 70 60 33 102,5 40 4 56 11 Connection example httpadditional technical data at: www.theben.de/product/ Article number 93

Presence detectors 24 V IGHT compact passage 24V Description 4 Passive infrared presence detector (PIR) Rectangular detection range for corridors Mixed light measurement Automatic control of lighting and HVAC as well as room monitoring function ight switch output (relay, oating) Presence switch output (relay, oating) ighting control with light threshold value and self-learning switch-off delay Pulse function for staircase timer HVAC control with switch-on delay and switch-off delay Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The switch-on delay prevents instantaneous switch on. The contact only closes on completion of the switch-on delay The sensitivity of the presence switch output is reduced in the "monitoring" position. The contact indicates the presence of people with a high degree of certainty Test operation mode checks the detection area and installation The parameters can either be set using the potentiometer or via the optional service remote control QuickSet plus Product selection Installation type Channel Operating voltage Colour Type Article number Ceiling installation ight Presence 24 V AC/DC pure white, (similar to RA 9010) c ompact passage 24V 2014090 pure black, (similar to RA 9005) compact passage 24V BK 2014806 Silver (similar to RA 9006) compact passage 24V SR 2014807 Technical data compact passage 24V Operating voltage 24 V AC/DC Setting range 10 1500 lx Recommended installation height 2 3.5 m ight switch-off delay Impulse (0.5 s), 10 s 20 min Presence switch-off delay 10 s 120 min Presence switch-on delay 0 s 10 min ight contact type Floating relay Presence contact type Floating relay Switching capacity Presence/ight 50 W (24 V AC/DC), 460 VA (230 V AC),, minimal 1 V/1 ma Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 94 www.theben.de/product/ Article number

IGHT Presence detectors 24 V Detection area (rectangular) Installation height (A) Head on to (r) Diagonally (t) 2 m 56 m² 16 m x 3.5 m ± 1 m 105 m² 30 m x 3.5 m ± 1 m A ux 2.5 m 72 m² 18 m x 4.0 m ± 1 m 120 m² 30 m x 4.0 m ± 1 m 3 m 90 m² 20 m x 4.5 m ± 1 m 135 m² 30 m x 4.5 m ± 1 m r t 3.5 m 100 m² 20 m x 5.0 m ± 1 m 150 m² 30 m x 5.0 m ± 1 m r t 4 Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Art.o.: 9070515 Details Page 233 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 Scale drawings compact passage 24V 40 44 102,5 26,5 19 25 48 70 60 102,5 40,5 75 4 56 11 33 63 Connection example httpadditional technical data at: www.theben.de/product/ Article number 95

Presence detectors 24 V IGHT ECO-IR 360-24V Description 4 Passive infrared presence detector (PIR) Square detection area Genuine daylight measurement The square detection area allows accurate and simple planning ight switch output (relay, oating) Presence switch output (relay, oating) Automatic control of lighting and HVAC ighting control with light threshold value and self-learning switch-off delay HVAC control with separate switch-off delay The presence detector has "Genuine light measurement" and is only suitable for switching uorescent lamps (F/P). Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence. The parameters are set via the potentiometer Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR 360-24V 2024000 Ceiling installation ight Presence 24 V AC/DC pure black, (similar to RA 9005) ECO-IR 360-24V BK 2024800 Silver (similar to RA 9006) ECO-IR 360-24V SR 2024801 further colours on request Technical data ECO-IR 360-24V Operating voltage 24 V AC/DC Setting range 50 1600 lx Recommended installation height 2 3.5 m ight switch-off delay 2 min 15 min Presence switch-off delay 1 60 min ight contact type Floating relay Presence contact type Floating relay Switching capacity Presence/ight 50 W (24 V AC/DC), 460 VA (230 V AC),, minimal 1 V/1 ma Ambient temperature +0 C +50 C Protection rating IP 40 Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m B C 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m 4.0 m 121 m² 11.0 m x 11.0 m ± 1 m http Additional technical data at: 96 www.theben.de/product/ Article number

IGHT Presence detectors 24 V Accessories QuickFix round cover Art.o.: 9070517 Details Page 233 QuickFix square cover Art.o.: 9070518 Details Page 232 Surface frame ECO-IR 360 Art.o.: 9070512 Details Page 232 Additional accessories s. p. 232 QuickFix concrete round cover Details Page 232 QuickFix concrete square cover Details Page 233 QuickFix concrete ushmounted box Details Page 233 QuickFix concrete ushmounted housing Details Page 233 QuickSafe Details Page 233 4 Scale drawings 87 4 48 70 60 66,5 46,3 21,3 4 56 11 35,5 37,5 95 22 84,5 Connection example httpadditional technical data at: www.theben.de/product/ Article number 97

Presence detectors 24 V IGHT ECO-IR 180A-24V Description 4 Passive infrared presence detector (PIR) 180 detection area Genuine daylight measurement Automatic control of lighting and HVAC ighting control with light threshold value and self-learning switch-off delay HVAC control with separate switch-off delay ight switch output (relay, oating) Presence switch output (relay, oating) The presence detector has "Genuine light measurement" and is only suitable for switching uorescent lamps (F/P). Presence switch contact for HVAC control: The switching behaviour of the oating contact is only controlled by presence The parameters are set via the potentiometer Product selection Installation type Channel Operating voltage Colour Type Article number pure white, (similar to RA 9010) ECO-IR 180A-24V 2024050 Wall installation ight Presence 24 V AC/DC pure black, (similar to RA 9005) ECO-IR 180A-24V BK 2024803 Silver (similar to RA 9006) ECO-IR 180A-24V SR 2024804 further colours on request Technical data ECO-IR 180A-24V Operating voltage 24 V AC/DC Setting range 50 1600 lx Recommended installation height 1.6 2.2 m ight switch-off delay 2 min 15 min Presence switch-off delay 10 60 min ight contact type Floating relay Presence contact type Floating relay Switching capacity Presence/ight 50 W (24 V AC/DC), 460 VA (230 V AC),, minimal 1 V/1 ma Ambient temperature +0 C +50 C Protection rating IP 40 Detection area (semicircular) Installation height (A) Sitting (B) Walking (C) 2.2 2.2 m 32 m² 8 m x 4 m 100 m² Ø 16 m A B C http Additional technical data at: 98 www.theben.de/product/ Article number

IGHT Presence detectors 24 V Accessories QuickSafe Art.o.: 9070531 Details Page 233 Surface frame ECO-IR 180 Art.o.: 9070511 Details Page 231 4 Scale drawings ECO-IR 180A-24V 85 48 70 60 85 46,3 21,3 4 56 11 35 45 80 70 Connection example ECO-IR 180A-24V ECO-IR 180A-24V httpadditional technical data at: www.theben.de/product/ Article number 99

IGHT http Additional technical data at: www.theben.de/product/ Article number 100

Section overview IGHT Motion detector Outdoor Installation type Detection angle Detection range Channel amp loads ight switchoff delay: Remote operation Type Page Wall installation, internal corner and external corner installation 150 12 m ight 1000 W 5 s 12 min UXA 101-150 102 180 12 m ight 1000 W 5 s 12 min UXA 101-180 102 Wall installation, internal corner and external corner installation 150 12 m ight 150 12 m ight 120 W ( 150 W) 400 W ( 500 W) 5 s 12 min UXA 102-150/150W 104 5 s 12 min UXA 102-150/500W 104 5 Wall and ceiling installation, internal corner and external corner installation 360 Ø 32 m ight 1000 W 5 s 12 min UXA 101-360 106 110 15 m ight 2300 W 1 s 20 min SPHIX 105-110 108 220 15 m ight 2300 W 1 s 20 min SPHIX 105-220 108 Indoor 300 15 m ight 2300 W 1 s 20 min SPHIX 105-300 108 Ceiling installation 360 Ø 7 m ight 1000 W 5 s 20 min UXA 103-360 110 ight Presence 1000 W 5 s 20 min UXA 103-360/2 110 Surface mounted ceiling installation 360 Ø 7 m ight 1000 W 5 s 20 min UXA 103-360 AP 112 ight Presence 1000 W 5 s 20 min UXA 103-360/2 AP 112 Flush-mounted wall installation 200 8 m ight 1000 W 20 s 30 min UXA 103-200 114 400 W 20 s 30 min UXA 103-200 T 114 httpadditional technical data at: www.theben.de/product/ Article number 101

Motion detector Outdoor IGHT Motion detector wall installation UXA 101-150 UXA 101-180 5 Description Common functions Passive infrared motion detector (PIR) For outdoor use Automatic lighting control based on presence and brightness Additional creep under protection Sensor head can be turned by ± 90 horizontally and by 40 downwards Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Single-handed plug-in installation with unloosable screws Instant start-up possible via factory preset Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area Controls are place protected UXA 101-150 150 detection angle UXA 101-180 180 detection angle Product selection Installation type Detection angle Channel Operating voltage Colour Type Article number Wall installation, internal corner and external corner installation with accessories 150 180 ight 230 V AC White UXA 101-150 1010963 Black UXA 101-150 1010964 White UXA 101-180 1010961 Black UXA 101-180 1010962 Technical data UXA 101-150 UXA 101-180 Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 8 VA Setting range 5 1000 lx umber of channels 1 10 A (at 230 V AC, cos = 1), Switching capacity light 6 A (at 230 V AC, cos = 0.6), 3 AX (at 230 V AC, cos = 0.3) Detection angle 150 180 ight switch-off delay 5 s 12 min Incandescent lamp load 1000 W http Additional technical data at: 102 www.theben.de/product/ Article number

IGHT Motion detector Outdoor UXA 101-150 UXA 101-180 Fluorescent lamp load ➀ not corrected 900 VA Flourescent lamp load ➀ parallel-corrected 200 VA Flourescent lamp load ➀ series-corrected 900 VA Flourescent lamp load ➁ 200 VA Ambient temperature 25 C +45 C Protection class II in accordance to E 60 669-2-1 Protection rating IP 55 ➀ conventional ballast, ➁ electronic ballast Detection range 5 150 5 m 2,5 m 180 5 m 2,5 m 12 m 12 m Walking diagonally to the detector Walking head on to the detector Creep under protection Installation height 2.5 m Accessories Scale drawings UXA corner angle black, Art.o.: 9070625 Details Page 234 UXA corner angle white, Art.o.: 9070626 Details Page 234 RC lter, Art.o: 9070523 Details Page 232 110 112 80 80 Connection example D1 D2 D1 D2 D1 D2 perm. O AUTO M httpadditional technical data at: www.theben.de/product/ Article number 103

Motion detector Outdoor IGHT Motion detector with halogen spotlight UXA 102-150/150W UXA 102-150/500W 5 Description Common functions Passive infrared motion detector (PIR) For outdoor use Integrated halogen spotlight for extensive lighting Energy saving ecohalogen light bulb with energy ef cient class C (R7s socket) included 150 detection angle Automatic lighting control based on presence and brightness Spotlight can be swivelled ± 45 horizontaly, and adjusted 60 upwards and 30 downwards using screw xings Additional creep under protection Sensor head can be turned by ± 90 horizontally and by 40 downwards Instant start-up possible via factory preset Single-handed plug-in installation with unloosable screws Controls are placed protected Additional light switch output (relay 230 V AC) Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Spotlight with tough aluminium die-cast housing Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area UXA 102-150/150W 120 W ecohalogen spotlight (comparable with regular 150 W spotlight) UXA 102-150/500W 400 W ecohalogen spotlight (comparable with regular 500 W spotlight) Product selection Installation type Channel Operating voltage Colour Type Article number Wall installation, internal corner and external corner installation with accessories ight 230 V AC White UXA 102-150/150W 1020961 Black UXA 102-150/150W 1020962 White UXA 102-150/500W 1020963 Black UXA 102-150/500W 1020964 Technical data UXA 102-150/150W UXA 102-150/500W Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 8 VA Power consumption 5 1000 lx Switching capacity ight 8 A (at 230 V AC, cos = 1), 6 A (at 230 V AC, cos = 0.6), 3 AX (at 230 V AC, cos = 0.3) http Additional technical data at: 104 www.theben.de/product/ Article number

IGHT Motion detector Outdoor UXA 102-150/150W UXA 102-150/500W ight switch-off delay 5 s 12 min umber of channels 1 Halogen spotlight 120 W Eco ( 150 W) 400 W Eco ( 500 W) Additonal incandescent/halogen lamp load 500 W Ambient temperature 25 C +45 C Protection class I in accordance with E 60 669-2-1 Protection rating IP 55 Detection range Connection example 5 150 5 m 2,5 m 12 m Walking diagonally to the detector Walking head on to the detector Creep under protection Installation height 2.5 m Accessories UXA corner angle white Only for UXA 102-150/150W Art.o.: 9070626 Details Page 234 UXA corner angle black Only for UXA 102-150/150W Art.o.: 9070625 Details Page 234 RC lter Art.o.: 9070523 Details Page 232 Scale drawings UXA 102-150/150W UXA 102-150/500W 145 139 156 200 265 220 150 101 httpadditional technical data at: www.theben.de/product/ Article number 105

Motion detector Outdoor IGHT UXA 101-360 Description 5 Product selection Passive infrared motion detector (PIR) For installation on walls and ceilings 360 detection angle Automatic lighting control based on presence and brightness Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Single-handed plug-in installation with unloosable screws Instant start-up possible via factory preset Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area Sensor head can be adjusted vertically by 90 upwards or 70 downwards, thus allowing universal installation Creep under protection Detection range can be limited using enclosed segments Screwless terminals for quick installation Installation type Detection angle Channel Incandescent lamp load Wall and ceiling mounted, internal corner and external corner installation Operating voltage Type Article number 360 ight 1000 W 230 V AC UXA 101-360 1010460 Technical data Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 8 VA Setting range 5 1000 lx umber of channels 1 10 A (at 230 V AC, cos = 1) Switching capacity light 6 A (at 230 V AC, cos = 0.6) 3 AX (at 230 V AC, cos = 0.3) Detection angle 360 ight switch-off delay 5 s 12 min Incandescent lamp load 1000 W ➀ conventional ballast, ➁ electronic ballast UXA 101-360 Fluorescent lamp load ➀ not corrected 900 VA Flourescent lamp load ➀ parallel-corrected 200 VA Flourescent lamp load ➀ series-corrected 900 VA Flourescent lamp load ➁ 200 VA Ambient temperature 15 C +45 C Protection class II in accordance to E 60 669-2-1 Protection rating IP 55 Detection range Scale drawings 144,3 92,4 360 5 m 80 65,7 16 m Walking diagonally to the detector Walking head on to the detector Installation height 2.5 m http Additional technical data at: 106 www.theben.de/product/ Article number

IGHT Motion detector Outdoor Accessories UXA corner angle white Art.o.: 9070626 Details Page 234 RC lter Art.o.: 9070523 Details Page 232 Connection example UXA 101-360 UXA 101-360 5 D1 D2 D1 D2 D1 D2 UXA 101-360 UXA 101-360 D1 D2 perm. O AUTO O OFF D1 D2 M httpadditional technical data at: www.theben.de/product/ Article number 107

Motion detector Outdoor IGHT Motion detector wall, ceiling, or corner installation 5 Description Passive infrared motion detector (PIR) Wall and ceiling installation Automatic lighting control based on presence and brightness Sensor head can be adjusted horizontally by ± 90, vertically by 90 upwards and 25 downwards Additional creep under protection Detection range can be limited using enclosed segments. Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Instant start-up possible via factory preset A cover plate protects controls against manipulation Single-handed plug-in installation with unloosable screws RC 105 pro, service remote control (optional) RC 105, user remote control (optional) Adjustable brightness switching value and switch-off delay Zero-cross switching Teach-in of current brightness value possible via remote control Imulse function Test function SPHIX 105-110 110 detection angle Especially suitable for narrow courtyard entrances, house entrances or paths Internal corner installation with optional corner installation bracket SPHIX 105-220 220 detection angle Particularly suitable for sides of properties, entrances and drives SPHIX 105-300 300 detection angle Corner installation bracket for internal or external corners included in delivery Especially suitable for external corner installation for simultaneous coverage of two facades via corner Product selection Installation type Detection angle Channel Incandescent lamp load 110 Operating voltage Type Article number SPHIX 105-110 1050110 Wall and ceiling mounted, internal corner and external corner installation 220 SPHIX 105-220 1050220 ight 2300 W 230 V AC 300 SPHIX 105-300 1050300 Technical data SPHIX 105-110 SPHIX 105-220 SPHIX 105-300 Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 8 VA Setting range 2 2000 lx umber of channels 1 16 A (at 230 V AC, cos = 1), Switching capacity light 10 A (at 230 V AC, cos = 0.6), 8 AX (at 230 V AC, cos = 0.3) Detection angle 110 220 300 ight switch-off delay 1 s 20 min Incandescent lamp load 2300 W http Additional technical data at: 108 www.theben.de/product/ Article number

IGHT Motion detector Outdoor SPHIX 105-110 SPHIX 105-220 SPHIX 105-300 Fluorescent lamp load ➀ not corrected 900 VA Flourescent lamp load ➀ parallel-corrected 400 VA Flourescent lamp load ➀ series-corrected 900 VA Flourescent lamp load ➁ 400 VA Compact energy saving lamps 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W Ambient temperature 25 C +55 C Protection class II in accordance to E 60 669-2-1 Protection rating IP 55 ➀ conventional ballast, ➁ electronic ballast Detection range 5 110 2,5 m 5 m 220 2,5 m 5 m 15 m 15 m Walking diagonally to the detector Walking head on to the detector Creep under protection Installation height 2.5 m 300 5 m 10 m 30 m Accessories SPHIX RC 105 Art.o.: 9070539 Details Page 235 SPHIX RC 105 Pro Art.o.: 9070537 Details Page 235 SPHIX corner angle Art.o.: 9070535 Details Page 235 RC lter Art.o.: 9070523 Details Page 232 Scale drawings Connection example 90 55 30 159 89 httpadditional technical data at: www.theben.de/product/ Article number 109

Motion detector Indoor IGHT Installation type Ceiling installation, ush-mounted 5 Description Small, inconspicuous passive infrared motion detector (PIR) Ceiling installation for suspended ceilings Automatic lighting control based on presence and brightness Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Sensor head can be adjusted downwards by 45 in 15 stages thus allowing detection area to be changed to avoid switching the device on unnecessarily Ceiling cut-out of 65 68 mm diameter Easy installation via two clamping brackets System consists of power box and sensor with plugged connection cable Sensor can easily be removed during painting work arge clamping area for quick installation Single-handed plug-in installation with unloosable screws Instant start-up possible via factory preset o unintentional adjustment due to covered up controls Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area Impulse function Test function UXA 103-360 1 channel UXA 103-360/2 2 channel 2. Relay for HVAC control with adjustable switch-off delay, presence-dependent, potential-free Product selection Installation type Detection angle Channel Incandescent lamp load Ceiling installation 360 Operating voltage Type Article number ight UXA 103-360 1030010 1000 W 230 V AC ight Presence UXA 103-360/2 1030011 Technical data UXA 103-360 UXA 103-360/2 Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 8 VA Setting range 10 2000 lx umber of channels 1 2 Switching capacity light 10 A (at 230 V AC, cos = 1), 3 AX (at 230 V AC, cos = 0.3) Presence switching capacity 5 A (cos = 1) 250 V AC or 24 V DC Detection angle 360 Recommended installation height 2 3 m ight switch-off delay 5 s 20 min Presence switch-off delay 10 s/15 min/30 min/60 min (in nitely variable) Incandescent lamp load 1000 W Flourescent lamp load ➀ parallel-corrected 400 VA Ambient temperature +0 C +45 C Protection class II in accordance to E 60 669-2-1 Protection rating Sensor IP 40, power unit IP 20 ➀ conventional ballast http Additional technical data at: 110 www.theben.de/product/ Article number

IGHT Motion detector Indoor Detection range Accessories RC lter Art.o.: 9070523 Details Page 232 360 2 m 3,5 m Walking diagonally to the detector Walking head on to the detector Installation height 2.5 m Scale drawings 5 123 37 Ø 80 60 15 53 58 Connection example UXA 103-360 UXA 103-360/2 D1 D2 M httpadditional technical data at: www.theben.de/product/ Article number 111

Motion detector Indoor IGHT Installation type Surface mount on ceiling 5 Description Passive infrared motion detector (PIR) for ceiling installation Automatic lighting control based on presence and brightness Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps Instant start-up possible via factory preset o unintentional adjustment due to covered up controls Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area Impulse function Test function Single-handed plug-in installation with unloosable screws UXA 103-360 AP 1 channel UXA 103-360/2 AP 2 channel 2. Relay for HVAC control, presence dependent, potential-free HVAC control with programmable switch-off delay Product selection Installation type Detection angle Channel Incandescent lamp load Surface mounted on ceiling 360 Operating voltage Type Article number ight 1000 W 230 V AC UXA 103-360 AP 1030020 ight Presence 1000 W 230 V AC UXA 103-360/2 AP 1030021 Technical data UXA 103-360 AP UXA 103-360/2 AP Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 5 VA Setting range 10 2000 lx umber of channels 1 2 Switching capacity light 10 A (at 230 V AC, cos = 1), 3 AX (at 230 V AC, cos = 0.3) Presence switching capacity 5 A (cos = 1) 250 V AC or 24 V DC Detection angle 360 Recommended installation height 2 3 m ight switch-off delay 5 s 20 min Presence switch-off delay 10 s 60 min (in nitely variable) Incandescent lamp load 1000 W Flourescent lamp load ➀ parallel-corrected 400 VA Ambient temperature +0 C +45 C Protection class II in accordance to E 60 669-2-1 Protection rating IP 40 ➀ conventional ballast http Additional technical data at: 112 www.theben.de/product/ Article number

IGHT Motion detector Indoor Detection range Accessories RC lter Art.o.: 9070523 Details Page 232 360 2 m 3,5 m Walking diagonally to the detector Walking head on to the detector Installation height 2.5 m Scale drawings Connection example 5 Ø 122 UXA 103-360 AP UXA 103-360/2 AP D2 D1 M 36 43 httpadditional technical data at: www.theben.de/product/ Article number 113

Motion detector Indoor IGHT Motion detector wall installation 5 Description Passive infrared motion detector (PIR) for wall installation Compatible with branded switches, replaces conventional light switches Automatic lighting control based on presence and brightness Instant start-up possible via factory preset o unintentional adjustment due to covered up controls Adjustable brightness switching value and switch-off delay Sensitivity can be reduced to limit detection area Pulse function Test function Detection range can be limited using enclosed segments. Manual AUTO/O/OFF switching by simple adjustment of cover ap Teach-in of current brightness value Expansion of detection area through integrated master/slave or master/master function when using up to 10 devices UXA 103-200 Mixed light measurement suitable for the control of uorescent, incandescent and halogen lamps With acoustic advance shut-off warning 15 seconds before light switches off UXA 103-200 T ike UXA 103-200, however: 2 wire connection, ideal for retro tting ight switch output (triac, 230 V AC) Advance shut-off warning through dimming 15 seconds before light switches off Mixed light measurement suitable for incandescent and halogen lamps (no electronic ballast) Product selection Installation type Detection angle Channel Incandescent lamp load Flush-mounted wall installation 200, circular ight Operating voltage Type Article number 1000 W UXA 103-200 1030030 230 V AC 400 W UXA 103-200 T 1030031 Technical data UXA 103-200 UXA 103-200 T Operating voltage 230 V AC Frequency 50 Hz Power consumption 6 VA Setting range 10 1000 lx umber of channels 1 Switching capacity light 10 A (at 230 V AC, cos = 1), 3 AX (at 230 V AC, cos = 0.3) 2 A (at 230 V AC, cos = 1) Detection angle 200, circular Recommended installation height 1.2 2 m ight switch-off delay 20 s 30 min Incandescent lamp load 1000 W 400 W Flourescent lamp load ➀ parallel-corrected 400 VA Ambient temperature +0 C +45 C Protection class II in accordance to E 60 669-2-1 Protection rating IP 40 ➀ conventional ballast http Additional technical data at: 114 www.theben.de/product/ Article number

8 m P T P T IGHT Motion detector Indoor Detection range Accessories RC lter Art.o.: 9070523 Details Page 232 Surface frame UXA 103-200 Art.o.: 9070504 Details Page 235 200 3 m Walking diagonally to the detector Walking head on to the detector Installation height 1.2 2 m Scale drawings 5 80 31,5 33,5 50 Connection example UXA 103-200 UXA 103-200 3 4 UXA 103-200 T UXA 103-200 T T T httpadditional technical data at: www.theben.de/product/ Article number 115

IGHT 116

Section overview IGHT Twilight switch umber of channels Setting range Switch on delay On/off switching delay separate External outputs PC interface Program Connection type Type Page Analogue, DI rail 2 100 lx 20 s Terminal screws UA 108 116 1 2 2000 lx 60 s DuoFix screwless terminals UA 109 116 2 50000 lx 0 20 min DuoFix screwless terminals UA 110 116 Digital without timer, DI rail 1 1 99000 lx 0 59 min 1 DuoFix Screwless terminals UA 111 top2 118 6 2 1 99000 lx 0 59 min 2 DuoFix Screwless terminals UA 112 top2 118 Digital with timer, DI rail 1 1 99000 lx 0 59 min 1 Weekly program DuoFix Screwless terminals UA 121 top2 RC 120 2 1 99000 lx 0 59 min 2 Weekly program DuoFix Screwless terminals UA 122 top2 RC 120 Analogue with timer, DI rail 1 2 2000 lx 0 59 min Weekly program DuoFix Screwless terminals UA 120 top2 120 Analogue without timer, wall installation or mast installation 5 200 lx 40 s 1 2 200 lx 2 100 s 2 2000 lx 2 100 s Analogue with timer, wall installation or mast installation Terminal screws Terminal screws Terminal screws UA 126 star with adapter plate 122 UA 127 star 122 UA 128 star 122 1 2 200 lx 0 10 min Daily program Terminal screws UA 129 star-time 122 117

Twilight switch Analogue, DI rail IGHT Twilight switch UA 108 UA 109 UA 110 6 Description UA 108 Analogue twilight switch External surface or ush-mounted light sensor included in delivery In nitely adjustable switching brightness Fixed On and Off switching delay Display of channel and switching status UA 109 ike UA 108, however: DuoFix spring terminals Test function UA 110 ike UA 109, however: Adjustable On and Off switching delay Extended brightness levels and adjustable delay Five adjustable brightness levels for simple setting of lux value Zero-cross switching Permanent OFF and permanent O function can be set on the potentiometer Product selection Setting range Switch on/off delay 2 100 lx 20 s 2 2000 lx 60 s 2 50000 lx 0 20 min * available October 2010 Connection type Operating voltage Sensor (included) Terminal screws DuoFix screwless terminals DuoFix screwless terminals 220 240 V AC 220 240 V AC 220 240 V AC 12 24 V UC Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Protection rating Type Article number IP 20, Sensor IP 54 IP 20, Sensor IP 65 IP 20, Sensor IP 55 IP 20, Sensor IP 65 IP 20, Sensor IP 55 IP 20, Sensor IP 65 IP 20, Sensor IP 55 UA 108 A 1080710 UA 108 E 1080700 UA 109 A 1090100 UA 109 E 1 090200 UA 110 A 1100100 UA 110 E 1 100200 UA 110 A 24V 1104100 * http Additional technical data at: 118 www.theben.de/product/ Article number

IGHT Twilight switch Analogue, DI rail Technical data UA 108 UA 109 UA 110 UA 110 A 24V Operating voltage 220 240 V AC 12 24 V UC Frequency 50 60 Hz Width 1 module 2 modules Power consumption 6 VA 3 VA Setting range 2 100 lx 2 2000 lx 2 50000 lx Switch-on delay 20 s 60 s 0 20 min Type of contact O contact Changeover contact Switch output potential free potential free, not for SEV Switching capacity 16 A (at 250 V AC, cos = 1) 10 AX (Fluorescent lamp load) 16 A (at 250 V AC, cos = 1) 16 AX (Fluorescent lamp load) 16 A (at 250 V AC, cos = 1) 10 AX (Fluorescent lamp load) Min. switching capacity 10 ma Incandescent lamp load 2300 W 3600 W 1400 W Fluorescent lamp load ➀ not corrected 2300 VA 3600 VA 1400 VA Fluorescent lamp load ➀ series-corrected: 2300 VA 3600 VA 1400 VA Fluorescent lamp load ➀ lead-lag circuit 2300 VA 3600 VA 1400 VA Compact energy saving lamps 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W 34 x 7 W, 27 x 11 W, 24 x 15 W, 22 x 23 W Ambient temperature 25 C +50 C 30 C +55 C Protection class II in accordance with E 60 730-1 Maximum cable length to sensor 25 m 100 m (2 x 1.5 mm 2 ) ➀ conventional 5 x 7 W, 4 x 11 W, 4 x 15 W, 4 x 20 W, 4 x 23 W 6 Accessories Wall mounting kit 17.5 mm For UA 108 Art.o.: 9070065 Details Page 230 Wall mounting kit 35 mm For UA 109, UA 110 Art.o.: 9070064 Details Page 230 Front panel kit Art.o.: 9070001 Details Page 228 Additional accessories Surface-mounted light sensor Details Page 235 Analogue surface-mounted light sensor Details Page 236 Analogure ush-mounted light sensor Details Page 236 Connection example UA 108 UA 109, UA 110 3 1 4 2 max. 25 m max. 100 m C1 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 119

Twilight switch Digital without timer, DI rail IGHT Twilight switch UA 111 top2 UA 112 top2 6 Description UA 111 top2 Digital twilight switch/lighting control device Switching brightness digitally adjustable Adjustable On and Off switching delay Switching brightness and switching delay can be set separately for switching On and Off Onscreen display of channel and switching status as well as current lux value DuoFix spring terminals Zero-cross switching Up to 4 sensors can be attached Up to 10 devices can be connected to a digital sensor Interface for OBEISK top2 memory card (PC programming) External light sensor included in delivery Extended brightness range Permanent O/OFF switching Test function Switching preselection Display lighting PI coding External control input Operating hours counter UA 112 top2 ike UA 111 top2, however: 2 channels 2 external control inputs Channel-independent hours counter Product selection umber of channels External outputs Switch on delay 1 1 2 2 Switching capacity at 250 V AC 0 59 min 16 A (10 AX) Sensor (included) Type Article number Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Flush-mounted light sensor UA 111 top2 A 1 110100 UA 111 top2 E 1 110200 UA 112 top2 A 1 120100 UA 112 top2 E 1 120200 http Additional technical data at: 120 www.theben.de/product/ Article number

IGHT Twilight switch Digital without timer, DI rail Technical data UA 111 top2 UA 112 top2 Operating voltage 230 240 V AC 100 240 V AC Frequency 50 60 Hz Width 2 modules 3 modules Power consumption 3 VA Setting range 1 99000 lx Switch-on delay 0 59 min Type of contact Changeover contact 2 Changeover contacts Switch output potential free, not for SEV Switching capacity 16 A (at 250 V AC, cos = 1), 10 A (at 250 V AC, cos = 0.6), 10 AX (Fluorescent lamp load) Min. switching capacity 10 ma Incandescent lamp load 2600 W Fluorescent lamp load ➀ not corrected 2300 VA Fluorescent lamp load ➀ series-corrected 2300 VA Fluorescent lamp load ➀ lead-lag circuit 2300 VA Compact energy saving lamps 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W Ambient temperature 30 C +55 C Protection class II in accordance with E 60 730-1 Maximum cable length to sensor 100 m (2 x 1.5 mm 2 ) ➀ conventional 6 Accessories OBEISK top2 PC set Art.o.: 9070409 Details Page 229 Memory card OBEISK top2 Art.o.: 9070404 Details Page 230 Front panel kit Art.o.: 9070001 Details Page 228 Additional accessories Digital surface-mounted light sensor Details Page 236 Digital ush-mounted light sensor Details Page 234 Wall mounting kit 35 mm Details Page 230 Wall mounting kit 52.5 mm Details Page 230 Connection example UA 111 top2 UA 112 top2 Ext1 ux 4 5 6 C2 ux max. 100 m + Data max. 100 m max. 100 m max. 100 m Ext1 Ext2 + Data max. 100 m C1 C1 1 2 3 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 121

Twilight switch Digital Analogue/digital with timer, with DI timer, rail, analogue DI rail with timer IGHT Twilight switch with time switch UA 120 top2 UA 121 top2 RC UA 122 top2 RC 6 Description Common functions Twilight switch with integrated weekly timer Adjustable On and Off switching delay Switching brightness and switching delay can be set separately for switching On and Off Fixed O and OFF times (e.g. night time interruption) DuoFix spring terminals Zero-cross switching Interface for OBEISK top2 memory card (PC programming) External light sensor included in delivery Permanent O/OFF switching Test function Switching preselection Display lighting PI coding Operating hours counter Onscreen display of channel and switching status Holiday and public holiday program with yearly function for xed and public holidays dependent on Easter Different summer/winter time rules can be selected or freely de ned UA 120 top2 Analogue twilight switch 1 channel Analogue adjustable switching brightness UA 121 top2 RC Digital twilight switch/lighting control 1 channel DCF77 or GPS radio controlled time via external antenna External control input Switching brightness digitally adjustable Variable lux values can be set for each day Up to 4 sensors can be attached Up to 10 devices can be connected to a digital sensor Extended brightness range 2 special programmes with yearly function UA 122 top2 RC ike UA 121 top2 RC, however: 2 channels Channel-independent operating hour counter 2 external control inputs Product selection umber of channels External outputs Special program 1 220 240 V AC 1 1 Yearly program 230 240 V AC 2 2 Yearly program 100 240 V AC http Operating voltage Sensor (included) Protection rating Type Article number Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Flush-mounted light sensor Surface-mounted light sensor Flush-mounted light sensor Additional technical data at: IP 20, Sensor IP 55 UA 120 top2 A 1200100 IP 20, Sensor IP 65 UA 120 top2 E 1 200200 IP 20, Sensor IP 55 UA 121 top2 RC A 1 210100 IP 20, Sensor IP 66 UA 121 top2 RC E 1 210200 IP 20, Sensor IP 55 UA 122 top2 RC A 1 220100 IP 20, Sensor IP 66 UA 122 top2 RC E 1 220200 122 www.theben.de/product/ Article number

IGHT Twilight switch Digital with Analogue/digital timer, DI rail, analogue with timer, with DI timer rail Technical data UA 120 top2 UA 121 top2 RC UA 122 top2 RC Operating voltage 220 240 V AC 230 240 V AC 100 240 V AC Frequency 50 60 Hz Width 3 modules 2 modules 3 modules Power consumption 3 VA Setting range 2 2000 lx 1 99000 lx Switch-on delay 0 59 min Type of contact Changeover contact Changeover contact 2 Changeover contacts Switch output potential free, not for SEV Switching capacity 16 A (at 250 V AC, cos = 1), 10 A (at 250 V AC, cos = 0.6), 10 AX (Fluorescent lamp load) Min. switching capacity 10 ma Incandescent lamp load 2600 W Fluorescent lamp load ➀ not corrected 2300 VA Fluorescent lamp load ➀ lead-lag circuit 2300 VA Compact energy saving lamps 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W Ambient temperature 30 C +55 C Protection class II in accordance with E 60 730-1 ➀ conventional 6 Accessories OBEISK top2 PC set Art.o.: 9070409 Details Page 229 Memory card OBEISK top2 Art.o.: 9070404 Details Page 230 Additional accessories top2 RC DCF antenna Details Page 228 Antenna top2 RC-GPS Details Page 228 Power unit top2 GPS Details Page 229 Additional accessories ight sensors Details Page 236 Wall mounting kit 35 mm Details Page 230 Wall mounting kit 52.5 mm Details Page 230 Front panel kit Details Page 228 Connection example UA 120 top2 UA 121 top2 RC UA 122 top2 RC Ext1 ux max. 100 m 4 5 6 C2 ux max. 100 m C1 1 2 3 max. 100 m max. 100 m C1 1 2 3 + Data RC DCF max. 100 m max. 100 m Ext1 Ext2 C1 1 2 3 + Data RC DCF httpadditional technical data at: www.theben.de/product/ Article number 123

Twilight switch Surface-mounted IGHT Surface-mounted twilight switch UA 126 star UA 129 star-time 6 Description UA 126 star Analogue twilight switch with integrated light sensor Cable feed from the back and from below Unloosable screws arge terminal area Brightness value can be set without opening the device arge light exposure angle (approx. 180 degrees) In nitely adjustable switching brightness Test button Fixed On and Off switching delay UA 127 star ike UA 126 star, however: Adjustable On and Off switching delay UA 128 star ike UA 126 star, however: Adjustable On and Off switching delay Expanded brightness range UA 129 star-time Digital twilight switch with integrated light sensor and time function for freelyprogrammable night switch-off (daily program) Adjustable On and Off switching delay Easy programming philosophy Preset night switch-off (23.00 OFF/5.00 O), lux values and switch delay Automatic summer/winter time changeover Cable feed from the back and from below Unloosable screws arge terminal area Brightness value can be set without opening the device Integrated replaceable lithium battery enables programming before installation arge light exposure angle (approx. 180 degrees) Switching brightness and switching delay can be set digitally for switching On and Off separately Test button Time function can be deactivated Product selection Setting range Switch-on delay Switching capacity at 230 V AC Additional program Type Article number 5 200 lx 40 s 10 A (6 AX) UA 126 star 1260700 5 200 lx 40 s 10 A (6 AX) UA 126 star 1260701 * 2 200 lx 2 100 s 16 A (10 AX) UA 127 star 1270700 2 2000 lx 2 100 s 16 A (10 AX) UA 128 star 1280700 2 200 lx 0 10 min 16 A (10 AX) integrated time switch UA 129 star-time 1290700 * Adapter plate included http Additional technical data at: 124 www.theben.de/product/ Article number

IGHT Twilight switch Surface-mounted Technical data UA 126 star UA 127 star UA 128 star UA 129 star-time Operating voltage 220 230 V AC Frequency 50 60 Hz Power consumption 3.5 VA 4.5 VA 2 VA Setting range 5 200 lx 2 200 lx 2 2000 lx 2 200 lx Switch-on delay 40 s 2 100 s 0 10 min Type of contact O contact Switch output 230 V Switching capacity 10 A (at 230 V AC, cos = 1) 6 AX (at 230 V AC, cos = 0.6) 16 A (at 230 V AC, cos = 1), 10 AX (at 230 V AC, cos = 0.6) Incandescent lamp load 1000 W 2300 W Fluorescent lamp load ➀ not corrected 1000 VA 2300 VA Fluorescent lamp load ➀ series-corrected 1000 VA 2300 VA Fluorescent lamp load ➀ lead-lag circuit 1000 VA 2300 VA Compact energy saving lamps 4 x 7 W, 3 x 11 W, 3 x 15 W, 3 x 20 W, 3 x 23 W 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W Ambient temperature 35 C +55 C Protection class II in accordance with E 60 730-1 Protection rating IP 55 ➀ conventional 6 Accessories Scale drawings Adapter plate UA star (included with 1260701) Art.o.: 9070486 Details Page 235 85 49,4 118,4 Connection example UA 126 star, UA 127 star, UA 128 star UA 129 star-time httpadditional technical data at: www.theben.de/product/ Article number 125

IGHT 126

Section overview IGHT Staircase time switch DI-rail, electronic Time Setting range Push button input Multivoltage input Switch-off pre-warning ong-time function Zero-cross switching o standby consumption 60 min EPA 1 128 Type Page 60 min EPA 6 128 0.5 20 min 150 ma EPA 3 128 EPA 7 128 DI-rail, electro-mechanical DI rail, Switch-off pre-warning 1 7 min 50 ma EPA 8 130 EPA 9 130 7 20 60 s EPA 4 130 Flush-mounted 60 min EPA 041 132 0.5 20 min 30 ma EPA 047 132 127

Staircase time switch DI-rail, electronic IGHT Staircase time switch electronic EPA 1 EPA 6 EPA 3 7 Description Common functions Staircase time switch, electronic Terminal layout same as EPA 8 Extremely accurate Push button input with electronic overload protection Automatic 3 or 4 conductor detection (4 conductor with connection for oor lighting) EPA 1 Zero-cross switching to preserve relay and lamp Multi-functional device with 10 available functions, set at the front of the device Additional multi-voltage input electrically isolated for AC/DC 8...240 V, e.g. für intercoms Advance shut-off warning (two double ashes) in accordance with DI 18015-2 to avoid sudden darkness. Extended function activated via long button press. Immediate secondary switching (staircase time switch) or prematurely switched off (impulse switch with switch-off delay). Electronic impulse switch Permanent light EPA 6 ike EPA 1, however: Without multi-voltage input EPA 3 Additional multi-voltage input electrically isolated for AC/DC 8...240 V, e.g. for intercoms Immediate secondary switching Toggle switch for permanent light EPA 7 ike EPA 3, however: Without multi-voltage input Product selection Incandescent lamp load 3600 W 2300 W Multi-function Multi-voltage input Switch-off pre-warning 3/4 conductors Crossover switch Type Article number Automatic EPA 1 0010002 Automatic EPA 6 0060002 Automatic EPA 3 0030002 Automatic EPA 7 0070002 http Additional technical data at: 128 www.theben.de/product/ Article number

IGHT Staircase time switch DI-rail, electronic Technical data EPA 1 EPA 6 EPA 3 EPA 7 Operating voltage 220 240 V AC Frequency 50 60 Hz Width 1 module Power consumption 6 VA Glow lamp load 150 ma Setting range 0.5 20 min 3/4 conductors Automatic Type of contact O contact Switch output on- oating (230 V) Incandescent lamp load 3600 W 2300 W Flourescent lamp load ➀ lead-lag circuit 3600 VA 2300 VA Flourescent lamp load ➀ parallel-corrected 1200 VA, (120 F) 400 VA, (42 F) Compact energy saving lamps 34 x 7 W, 27 x 11 W, 24 x 15 W, 22 x 23 W 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W Switching capacity 16 A (at 230 V AC, cos = 1) 16 AX (at 230 V AC, cos = 0.6) Test approvals V Ambient temperature 25 C +50 C Protection class II in accordance with E 60 730-1 Protection rating IP 20 ➀ conventional 16 A (at 230 V AC, cos = 1) 10 AX (at 230 V AC, cos = 0.6) 7 Accessories Connection example Wall mounting kit 17.5 mm Art.o.: 9070065 Details Page 230 Front panel kit Art.o.: 9070001 Details Page 228 EPA 1, EPA 3 + AC/DC 8...240 V B2 B3 3 3 4 max. 150 ma Connection example EPA 1, EPA 3 EPA 6, EPA 7 EPA 6, EPA 7 + AC/DC 8...240 V B2 B3 4 3 4 3 3 3 4 max. 150 ma 4 max. 150 ma 4 max. 150 ma http Additional technical data at: www.theben.de/product/ Article number 129

Staircase time switch DI-rail, electro-mechanical, switch-off pre-warning IGHT Staircase time switch electro-mechanical EPA 8 EPA 9 EPA 4 7 Description EPA 8 Staircase time switch, electromechanical o stand-by consumption Reliable due to synchronous motor drive Simple time setting and direct delay time readout on scale Precision mechanics and therefore exact switching period Very low sensitivity to interference Toggle switch for permanent light O 4-wire with connection for oor lighting 3-wire without oor lighting retriggerable EPA 9 ike EPA 8, however: 3-wire connection and oor lighting, but without secondary switching (no longer permitted for new systems) Terminal layout same as EPA 8 EPA 4 Switch-off pre-warning Additional device for staircase time switch EPA 3/EPA 8 or other brands Suitable for switching incandescent lamps and 230 V AC halogen lamps After the lighting period set on the staircase time switch EPA 3/EPA 8 has expired, EPA 4 switches to reduced brightness (approx. 50 %) Product selection Incandescent lamp load 2300 W Setting range o standby consumption Switch-off pre-warning 3/4 conductors Secondary switching Type Article number Yes After 30 s E PA 8 0080002 1 7 min Only 3 conductor o E PA 9 0090001 20 60 s Immediate EPA 4 0040001 http Additional technical data at: 130 www.theben.de/product/ Article number

IGHT Staircase time switch DI-rail, electro-mechanical, switch-off pre-warning Technical data EPA 8 EPA 9 EPA 4 Operating voltage 230 V AC Frequency 50 Hz 50 60 Hz Width 1 module Power consumption 1 VA Glow lamp load 50 ma Setting range 1 7 min 20 60 s 3/4 conductors Yes Only 3 conductor Type of contact O contact Switch output 230 V Flourescent lamp load ➀ lead-lag circuit 2300 VA Flourescent lamp load ➀ parallel-corrected 1300 VA, (70 F) Compact energy saving lamps 9 x 7 W, 6 x 11 W, 5 x 15 W, 5 x 20 W Switching capacity 16 A (at 230 V AC, cos = 1) 10 AX (at 230 V AC, cos = 0.6) 10 A (at 230 V AC, cos = 1) Test approvals V Ambient temperature 10 C +50 C Protection class II in accordance with E 60 730-1 Protection rating IP 20 ➀ conventional 7 Accessories Connection example Wall mounting kit 17.5 mm Art.o.: 9070065 Details Page 228 Front panel kit Art.o.: 9070001 Details Page 226 EPA 8 3 3 4 max. 50 ma Connection example EPA 8 EPA 9 EPA 4 4 3 EPA 4 max. 50 ma 4 3 3 3 4 max. 50 ma 4 3 http Additional technical data at: www.theben.de/product/ Article number 131

Staircase time switch Flush-mounted IGHT Staircase time switch, Flush-mounted EPA 047 EPA 041 Description 7 EPA 047 Flush-mounted staircase time switch, electronic Suitable for retro tting and new installation Switch or push button connectable, i.e. existing switches can be used (e.g. when updating) Zero-cross circuit for the protection of the relay contact Push-button input with electronic overload protection Automatic 3 or 4 conductor detection (4 conductor with connection for oor lighting) Extremely accurate Immediate secondary switching EPA 041 ike EPA 047, however: Multi-functional device with 12 available functions, set at the front of the device Additional multi-voltage input electrically isolated for AC/DC 8...240 V, e.g. for intercoms Advance shut-off warning (two double ashes) in accordance with DI 18015-2 to avoid sudden darkness 60 min. extended function activated via long button press Immediate secondary switching (staircase time switch) or prematurely switched off (impulse switch with switch-off delay). Can be connected via push-button or switch Product selection Incandescent lamp load 1800 W Multi-function Multi-voltage input Switch-off pre-warning 3/4 conductors Zero-cross switching Type Article number Automatic EPA 047 0470002 Automatic EPA 041 0410002 http Additional technical data at: 132 www.theben.de/product/ Article number

IGHT Staircase time switch Flush-mounted Technical data EPA 047 EPA 041 Operating voltage 230 V AC Frequency 50 60 Hz Power consumption 2 VA Glow lamp load 30 ma Setting range 0.5 20 min 3/4 conductors Automatic Type of contact O contact Switch output on- oating (230 V) Flourescent lamp load ➀ lead-lag circuit 1200 VA Flourescent lamp load ➀ parallel-corrected 580 VA, (54 F) Compact energy saving lamps 13 x 7 W, 7 x 11 W, 5 x 15 W, 5 x 20 W, 4 x 23 W Switching capacity 10 A (at 230 V AC, cos = 1), 6 AX (at 230 V AC, cos = 0.3) Test approvals V Ambient temperature 25 C +45 C Protection class II in accordance with E 60 730-1 Protection rating IP 20 ➀ conventional 7 Scale drawings EPA 041, EPA 047 Connection example EPA 047 52 23,5 4 48,4 Connection example EPA 041 EPA 041 + AC/DC 8...230 V 4 B2 * B3 B2 B3 with switch (cannot be used with three-way switch, multi-voltage input switch connection) httpadditional technical data at: www.theben.de/product/ Article number 133

CIMATE http Additional technical data at: www.theben.de/product/ Article number 134

Section overview CIMATE Clock thermostats Digital battery version Program Connection type Operating voltage Max. switching capacity at 250 V AC Type of contact Type Page 2/3 conductors 2 AA batteries 6 (1) A Two way switch RAMSES 811 top2 136 RAMSES 831 top2 136 RAMSES 813 top2 HF Set A 140 Weekly program Radio controlled 2 AA batteries 16 (2) A O contact RAMSES 813 top2 HF Set S 140 RAMSES 813 top2 HF Set 1 140 6 (1) A Two way switch RAMSES 833 top2 HF Set 1 142 RAMSES 833 top2 HF Set 2 142 Digital 230 V Weekly program 3/4 conductors 230 V AC 6 (1) A Two way switch RAMSES 812 top2 138 RAMSES 832 top2 138 OpenTherm Digital 230 V, DI-rail Weekly program 2 conductor (BUS) 230 V AC 8 (1) A 4 O contacts RAMSES 855 top2 OT 144 8 Weekly program Terminal screws max. 4 mm² 230 V AC 10 (2) A Two way switch RAMSES 366/1 top 146 RAMSES 366/2 top 146 Analogue battery version Daily program 2/3 conductors 2 AA batteries 6 (1) A Two way switch RAMSES 784 S 148 Daily/weekly program 2/3 conductors 2 AA batteries 6 (1) A Two way switch RAMSES 784 150 Analogue 230 V RAMSES 722 S 148 Daily program 3/4 conductors 230 V AC 6 (1) A Two way switch RAMSES 782 S 148 RAMSES 722 150 Daily/weekly program 3/4 conductors 230 V AC 6 (1) A Two way switch RAMSES 782 150 Daily program 3/4 conductors 230 V AC 6 (1) A Two way switch RAMSES 721 150 Daily/weekly program 3/4 conductors 230 V AC 6 (1) A Two way switch RAMSES 725 150 httpadditional technical data at: www.theben.de/product/ Article number 135

Clock thermostats Digital battery version CIMATE Digital clock thermostats battery version RAMSES 811 top2 RAMSES 831 top2 Description 8 Common functions Digital clock thermostat with a low pro le design for time-dependent monitoring and control of room temperature Battery version Suitable for energy-saving room temperature control in houses, apartments, heating zones, of ces, showrooms, factories, medical practices, holiday homes Required temperature set via the rotary dial IFO key for viewing important settings Quick start-up via 3 basic programs with individually changeable comfort and reduced temperature Party/ECO program Automatic summer/winter time adjustment Holiday program with reduction phase or date-controlled heating phase for holiday homes Different control types can be individually set Optimum start option thanks to operating point and switching differential setting option 24 programmable time phases per program also enable reduction phases during the day Plug-in base for wall or ush-mounted socket installation Optional pump protection function Optional feature to warn when boiler maintenance required RAMSES 811 top2 2 comfort and 2 reduced temperatures can be allocated to each phase RAMSES 831 top2 Illuminated display through keystroke External input for connection of presence detectors, temperature sensors, oor sensors, window contacts or telephone remote switches Optimisation function for automatic correction of heating start up 3 comfort and 2 reduction programs can be allocated to each phase Product selection Connection type Program Max. switching capacity at 250 V AC 2/3 conductors Weekly program 6 (1) A +6 C +30 C 2 AA batteries Setting range Operating voltage Type Article number RAMSES 811 top2 8119132 RAMSES 831 top2 8319132 http Additional technical data at: 136 www.theben.de/product/ Article number

CIMATE Clock thermostats Digital battery version Technical data RAMSES 811 top2 RAMSES 831 top2 Operating voltage 2 AA batteries Type of contact Two way switch Max. switching capacity 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Adjustable temperature +6 C +30 C Time based on Quartz Program Weekly program, daily program, holiday program, 3 basic programs umber of memory cells 42, max. 24 per program Control types Pulse width modulation or hysteresis controller Control period 5 30 min Control capture range 0.2 5 K Switch output Floating Time accuracy ± 1 s/day (Quartz) Power reserve Max. 10 min with no loss of time Battery life approx. 1 year, depending on switching frequency Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories 8 Actuator APHA 4 Art.o.: 9070438 (230 V) Details Page 238 Art.o.: 9070439 (24 V) Details Page 238 External temperature sensor 1 For RAMSES 831 top2 Art.o.: 9070191 Details Page 237 External temperature sensor 2 For RAMSES 831 top2 Art.o.: 9070192 Details Page 237 External temp. sensor IP 65 For RAMSES 831 top2 Art.o.: 9070459 Details Page 237 Scale drawings Connection example 95 3 1 2 3 1 2 140 23 httpadditional technical data at: www.theben.de/product/ Article number 137

Clock thermostats Digital 230 V CIMATE Digital clock thermostat mains version RAMSES 812 top2 RAMSES 832 top2 Description 8 Common functions Digital clock thermostat with a low pro le design for time-dependent monitoring and control of room temperature Mains version Suitable for energy-saving room temperature control in houses, apartments, heating zones, of ces, showrooms, factories, medical practices, holiday homes Required temperature set via the rotary dial IFO key for viewing important settings Quick start-up via 3 basic programs with individually changeable comfort and reduced temperature Party/ECO program Automatic summer/winter time adjustment Different control types can be individually set Optimum start option thanks to operating point and switching differential setting option 24 programmable time phases per program also enable reduction phases during the day Plug-in base for wall or ush-mounted socket installation Holiday program with reduced temperature or date-controlled heating phase Optional pump protection function Optional feature to warn when boiler maintenance required RAMSES 812 top2 2 comfort and 2 reduction programs can be allocated to each phase RAMSES 832 top2 Illuminated display through keystroke External input for connection of presence detectors, temperature sensors, oor sensors, window contacts or telephone remote switches Optimisation function for automatic correction of heating start up 3 comfort and 2 reduction programs can be allocated to each phase Product selection Connection type Program Max. switching capacity at 250 V AC 3/4 conductors Weekly program 6 (1) A +6 C +30 C 230 V AC Setting range Operating voltage Type Article number RAMSES 812 top2 8120132 RAMSES 832 top2 8320132 http Additional technical data at: 138 www.theben.de/product/ Article number

CIMATE Clock thermostats Digital 230 V Technical data RAMSES 812 top2 RAMSES 832 top2 Operating voltage 230 V AC Frequency 50 Hz Type of contact Two way switch Max. switching capacity 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Adjustable temperature +6 C +30 C Time based on Quartz Program Weekly program, daily program, holiday program, 3 basic programs umber of memory cells 42, max. 24 per program Control types Pulse width modulation or hysteresis controller Control period 5 30 min Control capture range 0.2-5 K Switch output Floating Time accuracy ± 1 s/day (Quartz) Power reserve 5 hours Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories 8 Actuator APHA 4 Art.o.: 9070438 (230 V) Details Page 238 Art.o.: 9070439 (24 V) Details Page 238 External temperature sensor 1 For RAMSES 832 top2 Art.o.: 9070191 Details Page 237 External temperature sensor 2 For RAMSES 832 top2 Art.o.: 9070192 Details Page 237 External temp. sensor IP 65 For RAMSES 832 top2 Art.o.: 9070459 Details Page 237 Scale drawings Connection example 95 3 2 1 6 5 4 3 2 1 6 5 4 140 23 - + httpadditional technical data at: www.theben.de/product/ Article number 139

Clock thermostats Digital battery version CIMATE Digital clock thermostats radio controlled RAMSES 813 top2 HF Set A RAMSES 813 top2 HF Set S RAMSES 813 top2 HF Set 1 Description 8 Common functions Radio-controlled system for room temperature control The system consists of a digital clock thermostat and one receiver Suitable for energy-saving room temperature control in houses, apartments, heating zones, of ces, showrooms, factories, medical practices, holiday homes Required temperature set via the rotary dial IFO key for viewing important settings Quick start-up via 3 basic programs with individually changeable comfort and reduced temperature Party / ECO program Automatic summer/winter time adjustment Different control types can be individually set Optimum start option thanks to operating point and switching differential setting option 24 programmable time phases per program also enable reduction phases during the day 2 comfort and 2 reduction programs can be allocated to each phase Including base for free choice of position An optionally available plug-in base is required for wall installation Holiday program with reduced temperature or date-controlled heating phase Optional pump protection function Optional feature to warn when boiler maintenance required RAMSES 813 top2 HF Set A Consisting of a RAMSES 813 top2 HF and a REC 11receiver with an O contact 16(2) A/250 V AC for wall installation RAMSES 813 top2 HF Set S Consisting of a RAMSES 813 top2 HF and a REC 21 receiver as earthed intermediate connector with an O contact 16 (2) A/230 V AC RAMSES 813 top2 HF Set 1 Consisting of a RAMSES 813 top2 HF and a REC 1 receiver with a two-way switch 6 (2) A/250 V AC Product selection Connection type Program Max. switching capacity at 250 V AC Radio Weekly program Setting range Operating voltage Type Article number RAMSES 813 top2 HF Set A 8139503 16 (2) A +6 C +30 C 2 AA batteries RAMSES 813 top2 HF Set S 8139505 6 (1) A +6 C +30 C 2 AA batteries RAMSES 813 top2 HF Set 1 8139501 http Additional technical data at: 140 www.theben.de/product/ Article number

CIMATE Clock thermostats Digital battery version Technical data RAMSES 813 top2 HF Set A RAMSES 813 top2 HF Set S RAMSES 813 top2 HF Set 1 Operating voltage 2 AA batteries Type of contact O contact Two way switch Max. switching capacity 16 A (at 250 V AC, cos = 1), 2 A (at 250 V AC, cos = 0.6) 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Adjustable temperature +6 C +30 C Time based on Quartz Program Weekly program, daily program, holiday program, 3 basic programs umber of memory cells 42, max. 24 per program Control types Pulse width modulation or hysteresis controller Control period 5 30 min Control capture range 0.2 5 K Switch output Floating Time accuracy ± 1 s/day (Quartz) Power reserve Max. 10 min with no loss of time Battery life approx. 1 year, depending on switching frequency Width 5 modules Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories Connection example 8 Socket RAMSES Details Page 238 Actuator APHA 4 230 V Details Page 238 Actuator APHA 4 24 V Details Page 238 Antenna RAMSES 813/833 Details Page 237 RAMSES 813 top2 HF Set A C1 1 2 3 C1 RAMSES 813 top2 HF Set 1 7 8 C1 1 2 3 C1 Scale drawings RAMSES 813 top2 HF Set A 80 30,8 RAMSES 813 top2 HF Set S 80 36 RAMSES 813 top2 HF Set 1 120 120 95 140 23 httpadditional technical data at: www.theben.de/product/ Article number 141

Clock thermostats Digital battery version CIMATE Digital clock thermostats radio controlled RAMSES 833 top2 HF Set 1 RAMSES 833 top2 HF Set 2 Description 8 Common functions Radio-controlled system for room temperature control The system consists of one or two digital clock thermostat and one receiver Suitable for energy-saving room temperature control in houses, apartments, heating zones, of ces, showrooms, factories, medical practices, holiday homes Required temperature set via the rotary dial IFO key for viewing important settings Quick start-up via 3 basic programs with individually changeable comfort and reduced temperature Party/ECO program Automatic summer/winter time adjustment Different control types can be individually set Optimum start option thanks to operating point and switching differential setting option 24 programmable time phases per program also enable reduction phases during the day Illuminated display through keystroke External input for connection of presence detectors, temperature sensors, oor sensors, window contacts or telephone remote switches (can only be used in connection with optional plug-in base for wall mounting) Optimisation function for automatic correction of heating start up Holiday program with reduction phase or date-controlled heating phase for holiday homes Optional feature to warn when boiler maintenance required Optional pump protection function 3 comfort and 2 reduction programs can be allocated to each phase. Including base for free choice of position An optionally available plug-in base is required for wall installation RAMSES 833 top2 HF Set 1 Consisting of a RAMSES 833 top2 HF and a REC 1 receiver with a two-way switch 6 (2) A/250 V DC RAMSES 833 top2 HF Set 2 Consisting of a RAMSES 833 top2 HF and a 2 channel REC 2 receiver with a two-way switch 6 (2) A/250 V DC per channel Product selection Connection type Program Max. switching capacity at 250 V AC Radio Weekly program 6 (1) A +6 C +30 C 2 AA batteries Setting range Operating voltage Type Article number RAMSES 833 top2 HF Set 1 8339501 RAMSES 833 top2 HF Set 2 8339502 http Additional technical data at: 142 www.theben.de/product/ Article number

CIMATE Clock thermostats Digital battery version Technical data RAMSES 833 top2 HF Set 1 RAMSES 833 top2 HF Set 2 Operating voltage 2 AA batteries Type of contact Two way switch Max. switching capacity 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Adjustable temperature +6 C +30 C Time based on Quartz Program Weekly program, daily program, holiday program, 3 basic programs umber of memory cells 42, max. 24 per program Control types Pulse width modulation or hysteresis controller Control period 5 30 min Control capture range 0.2 5 K Switch output Floating Time accuracy ± 1 s/day (Quartz) Power reserve Max. 10 min with no loss of time Battery life approx. 1 year, depending on switching frequency Width 5 modules Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories 8 Actuator APHA 4 230 V Art.o.: 9070438 Details Page 238 Actuator APHA 4 24 V Art.o.: 9070439 Details Page 238 External temperature sensor 1 Art.o.: 9070191 Details Page 237 Additional accessories Antenna RAMSES 813/833 Details Page 237 External temp. sensor IP65 Details Page 237 External temperature sensor 2 Details Page 237 Socket RAMSES Details Page 238 Scale drawings RAMSES 833 top2 HF Set 1, RAMSES 833 top2 HF Set 2 Connection example RAMSES 833 top2 HF Set 1 RAMSES 833 top2 HF Set 2 7 8 7 8 95 C1 C1 C1 C1 C2 C2 140 23 1 2 3 1 2 3 4 5 6 httpadditional technical data at: www.theben.de/product/ Article number 143

Clock thermostats OpenTherm CIMATE RAMSES 855 top2 OT Description Digital heating control for time-dependent monitoring and control of room temperature Open Therm heating controller for 2 or 3 point control, weather-dependent, service water and circulation control Selector switch for 8 different types of connection/function Automatic sensor recognition for weather or room dependent control, can be switched manually at any time 3 different weekly programs 3 comfort and 2 reduced temperatures can be allocated to each phase. IFO button for the most important data RS 232 interface for GSM modem Additional switching program for service water utilisation times Adjustable service water storage temperature, programmable legionella protection Party/ECO program Holiday program with reduction phase or date-controlled heating phase for holiday homes Automatic summer/winter time correction Boiler/run up temperature (control circuit 1) controlled by switching the burner Feed temperature (control circuit 2) controlled via pump or mechanicallyadjustable mixer 3-point controller with feed sensor Time and temperature dependent control of hot water circulation pump. Pump protection function Hour counter for recording relay switching times e.g. burner running time. Settable reminder function for heater maintenance Inputs: External sensor (included in set), heating circuit feed sensor (included in set), feed or plunge sensor for service water, feed sensor for circulation 8 Product selection Connection type Program Max. switching capacity at 250 V AC Setting range Operating voltage Type Article number 2 conductor (BUS) Weekly program 8 (1) A +6 C +30 C 230 V AC RAMSES 855 top2 OT 8559132 Technical data RAMSES 855 top2 OT Operating voltage 230 V AC Frequency 50-60 Hz Type of contact 4 O contacts Max. switching capacity 8 (1) A Adjustable temperature +6 C +30 C Feed temperature limit +40 C +90 C Connection type 2 conductor (BUS) Program Weekly program umber of memory cells 42, max. 24 per program Switching hysteresis 2 20 K Mixer runtime 2 10 min Switch output Floating Power reserve 4 hours Type of protection IP 20 Protection class II in accordance with E 60 730-1 http Additional technical data at: 144 www.theben.de/product/ Article number

CIMATE Clock thermostats OpenTherm Accessories Plunge sensor RAMSES Art.o.: 9070379 Details Page 238 Flow temperature sensor Art.o.: 9070371 Details Page 237 RAMSES OT Center Art.o.: 9070427 Details Page 237 GSM modem Art.o.: 9070396 Details Page 237 Scale drawings RAMSES 855 top2 OT 95 140 23 Connection example RAMSES 855 top2 OT RAMSES 855 top2 OT RAMSES 855 top2 OT + OT-Center 8 RAMSES RAMSES + RAMSES 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 10 11 12 13 14 15 16 17 18 19 10 11 12 13 14 15 16 17 18 19 OT-Box + Additional connection diagrams at www.theben.de httpadditional technical data at: www.theben.de/product/ Article number 145

Clock thermostats Digital 230 V, DI-rail CIMATE Digital clock thermostat zone control RAMSES 366/1 top RAMSES 366/2 top Description 8 Common functions Digital clock thermostat for timedependent control of room temperature Daily/weekly program can be set to the minute Date-controlled holiday program Programming displayed graphically by a bar arrangement in the CD Automatic summer/winter time adjustment Product selection Manual switching pre-selection and operation mode selector for: Automatic mode, comfort mode, reduction mode, frost protection mode PI coding Connection for telephone remote control for switching to comfort mode or frost protection mode ED display of active operating status as well as relay status RAMSES 366/1 top Zone control, 1 zone 1 external temperature sensor required RAMSES 366/2 top Zone control, 2 zones 2 external temperature sensors required umber of channels Program Max. switching capacity at 250 V AC Setting range Operating voltage Type Article number 1 Weekly program 10 (2) A +6 C +30 C 230 V AC RAMSES 366/1 top 3660002 2 Weekly program 10 (2) A +6 C +30 C 230 V AC RAMSES 366/2 top 3660052 http Additional technical data at: 146 www.theben.de/product/ Article number

CIMATE Clock thermostats Digital 230 V, DI-rail Technical data RAMSES 366/1 top RAMSES 366/2 top Operating voltage 230 V AC Frequency 50 60 Hz Type of contact Two way switch Max. switching capacity 10 A (at 250 V AC, cos = 1), 2 A (at 250 V AC, cos = 0.6) Adjustable temperature +6 C +30 C Time based on Quartz Program Weekly program, daily program, holiday program umber of memory cells 42 Switch output Floating Time accuracy ± 1 s/day (Quartz) Power reserve 10 years Width 6 modules Type of protection IP 20 Accessories External temperature sensor 1 Art.o.: 9070191 Details Page 237 External temperature sensor 2 Art.o.: 9070192 Details Page 237 External temp. sensor IP 65 Art.o.: 9070459 Details Page 237 Additional accessories Actuator APHA 4 230 V Details Page 238 Actuator APHA 4 24 V Details Page 238 8 Connection example RAMSES 366/1 top RAMSES 366/2 top 4 5 6 7 8 9 7 8 9 10 11 12 13 14 ** ** 1 2 3 1 2 3 4 5 6 * * * * Control of circulation pump, electronic actuator, thermal mixer valve or oil/gas burner ** Connection for separate telephone remote switch httpadditional technical data at: www.theben.de/product/ Article number 147

Clock thermostats Analogue battery version, analogue 230 V CIMATE Analogue clock thermostat - segments RAMSES 784 S Description 8 Common functions Analogue clock thermostat with a low pro- le design for time-dependent monitoring and control of room temperature. Operating point and electronic recirculation are set from the front Party switch and program display Electronic temperature control ormal and reduced temperature can be set separately Selector switch for operating mode: continuous reduced temperature, continuous normal temperature, automatic mode, frost and plant protection +6 C RAMSES 784 S With batteries for 2 or 3 conductor connection Battery monitoring with battery replacement indicator via ashing ED Silting and pump protection function (option) Quartz mechanism Segment program disc with daily program RAMSES 722 S Mains version Segment program disc with daily program Synchronous motor drive RAMSES 782 S Mains version Segment program disc with daily program Quartz mechanism, 3 day power reserve Product selection Power reserve Connection type Program Type of contact Setting range Operating voltage Type Article number 2/3 conductors Daily program Two way switch +10 C +30 C 2 AA batteries R AMSES 784 S 7840801 3/4 conductors Daily program Two way switch +10 C +30 C 230 V AC RAMSES 722 S 7220801 3 days 3/4 conductors Daily program Two way switch +10 C +30 C 230 V AC RAMSES 782 S 7820801 http Additional technical data at: 148 www.theben.de/product/ Article number

CIMATE Clock thermostats Analogue battery version, analogue 230 V Technical data RAMSES 784 S RAMSES 722 S RAMSES 782 S Operating voltage 2 AA batteries 230 V AC Frequency 50 Hz 50 60 Hz Type of contact Two way switch Program Daily program Max. switching capacity 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Switching differential 0.4 1.2 K Switch output Floating Setting range +10 C +30 C Shortest switching time 15 min Programmable every 15 min Time accuracy ± 1 s/day (Quartz) Synchronised with mains ± 1 s/day (Quartz) Power reserve 3 days Display 1 ED-Battery monitoring 1 ED Heating Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories Actuator APHA 4 230 V Art.o.: 9070438 Details Page 238 Additional accessories Actuator APHA 4 24 V Details Page 238 Adapter RAMSES 72x/78x Details Page 236 Scale drawings RAMSES 784 S, RAMSES 722 S, RAMSES 782 S 29,5 8 90 150 35,5 Connection example RAMSES 784 S RAMSES 784 S RAMSES 722 S, RAMSES 782 S RAMSES 722 S, RAMSES 782 S 1 2 3 1 2 3 1 2 3 1 2 3 4 5 4 5 + - + - httpadditional technical data at: www.theben.de/product/ Article number 149

Clock thermostat Analogue battery version, analogue 230 V CIMATE Analogue clock thermostat - tappet RAMSES 784 RAMSES 721 Description 8 Common functions Analogue clock thermostat with a low pro- le design for time-dependent monitoring and control of room temperature. Operating point and electronic recirculation are set from the front Party switch and program display Electronic temperature control ormal and reduced temperature can be set separately RAMSES 784 Selector switch for operating mode: continuous reduced temperature, continuous normal temperature, automatic mode, frost and plant protection +6 C With batteries for 2 or 3 conductor connection Battery monitoring with battery replacement indicator via ashing ED Silting and pump protection function (option) Quartz mechanism Tappet program disc with daily or weekly program RAMSES 722 Mains version Selector switch for operating mode: continuous reduced temperature, continuous normal temperature, automatic mode, frost and plant protection +6 C Tappet program disc with daily or weekly program Synchronous motor drive RAMSES 782 Mains version Selector switch for operating mode: continuous reduced temperature, continuous normal temperature, automatic mode, frost and plant protection +6 C Tappet program disc with daily or weekly program Quartz mechanism, 3 day power reserve RAMSES 721 Mains version Reduced temperature approx. 5 K lower in relation to the set comfort temperature Tappet program disc with daily program Synchronous motor drive RAMSES 725 ike RAMSES 722, however: Central control of reduced temperature as per time program Product selection Power reserve Connection type Program Type of contact Setting range Operating voltage Type Article number 2/3 conductors Daily/weekly program Two way switch +10 C +30 C 2 AA batteries RAMSES 784 7840030 3/4 conductors Daily/weekly program Two way switch +10 C +30 C 230 V AC RAMSES 722 7220030 3 days 3/4 conductors Daily/weekly program Two way switch +10 C +30 C 230 V AC RAMSES 782 7820030 3/4 conductors Daily program Two way switch +10 C +30 C 230 V AC RAMSES 721 7210030 Daily/weekly program Two way switch +10 C +30 C 230 V AC RAMSES 725 7250030 http Additional technical data at: 150 www.theben.de/product/ Article number

CIMATE Clock thermostat Analogue battery version, analogue 230 V Technical data RAMSES 784 RAMSES 722 RAMSES 782 RAMSES 721 RAMSES 725 Operating voltage 2 AA batteries 230 V AC Frequency 50 Hz 50 60 Hz 50 Hz Type of contact Two way switch Program Daily/weekly program Daily program Daily/weekly program Max. switching capacity 6 A (at 250 V AC, cos = 1), 1 A (at 250 V AC, cos = 0.6) Switching differential 0.4 1.2 K 0 1.2 K 0.4 1.2 K 1.5 K Switch output Floating Setting range +10 C +30 C Shortest switching time 20 min, 120 min 20 min 20 min, 120 min Programmable every 5 min, 30 min 5 min 5 min, 30 min Time accuracy ± 1 s/day (Quartz) Synchronised with mains ± 1 s/day (Quartz) Synchronised with mains Power reserve 3 days Display 1 ED-Battery monitoring 1 ED Heating Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories Actuator APHA 4 230 V Art.o.: 9070438 Details Page 238 Additional accessories Actuator APHA 4 24 V Details Page 238 Adapter RAMSES 72x/78x Details Page 236 Scale drawings 90 29,5 8 150 35,5 Connection example RAMSES 784 RAMSES 784 RAMSES 722, RAMSES 782, RAMSES 721, RAMSES 725 RAMSES 722, RAMSES 782, RAMSES 721, RAMSES 725 1 2 3 1 2 3 1 2 3 1 2 3 4 5 4 5 + - + - httpadditional technical data at: www.theben.de/product/ Article number 151

CIMATE http Additional technical data at: www.theben.de/product/ Article number 152

w Section overview CIMATE Room thermostats Mechanical Connection type Switching capacity at 230 V AC Type of contact Operating voltage Installation type Type Page 2/3 conductors 10 (4) A C contact 230 240 V AC Surface-mounted RAMSES 701 154 RAMSES 702 154 3/4 conductors 10 (4) A C contact 230 240 V AC Surface-mounted RAMSES 703 154 RAMSES 704 154 RAMSES 705 154 4/5 conductors 10 (4) A C contact 230 240 V AC Surface-mounted RAMSES 706 154 RAMSES 707 154 3/4 conductors 4/5 conductors Heating: 10 (4) A Cooling: 5 (2) A Heating: 10 (4) A Cooling: 5 (2) A Two way switch 230 240 V AC Surface-mounted RAMSES 708 154 Two way switch 230 240 V AC Surface-mounted RAMSES 709 154 2/3 conductors 10 (4) A C contact 230 240 V AC Flush-mounted RAMSES 741 156 4/5 conductors 10 (4) A C contact 230 240 V AC Flush-mounted RAMSES 746 156 3/4 conductors Heating: 10 (4) A Cooling: 5 (1) A Two way switch 230 240 V AC Flush-mounted RAMSES 748 156 Electronic 2/3 conductors 10 (4) A C contact 230 240 V AC Flush-mounted RAMSES 741 RA 156 4/5 conductors 10 (4) A C contact 230 240 V AC Flush-mounted RAMSES 746 RA 156 3/4 conductors Heating: 10 (4) A Cooling: 5 (1) A Two way switch 230 240 V AC Flush-mounted RAMSES 748 RA 156 2/3 conductors 8 A C contact 230 V AC Surface-mounted RAMSES 714 158 9 4/5 conductors 16 A C contact 230 V AC Surface-mounted RAMSES 714 A 158 RAMSES 714 A/FH 158 5 conductor 16 (4) A O contact 230 V AC Flush-mounted RAMSES 751 RA 158 httpadditional technical data at: www.theben.de/product/ Article number 153

Room thermostats Mechanical CIMATE Mechanical room thermostat surface-mounted RAMSES 701 RAMSES 706 RAMSES 707 Description 9 Common functions Room temperature controller with thermal feedback Suitable for all types of heating, e. g. gas, water, electric heating with central/individual room control Setting controller with mechanical setting limit or detection RAMSES 701 See general description RAMSES 702 Integrated temperature reduction (approx. 4 K) possible via control with timer RAMSES 703 Internal setting: Temperature cannot be set externally. Temperature is set inside the device at start-up Integrated temperature reduction (approx. 4 K) possible via control with timer RAMSES 704 Switch for additional heating O/OFF + indicator lamp RAMSES 705 Switch for heating O/OFF RAMSES 706 Switch for heating O/OFF + indicator lamp Integrated temperature reduction (approx. 4 K) possible via control with timer RAMSES 707 Switch for heating O/OFF Switch for additional heating O/OFF + indicator lamp RAMSES 708 Also suitable for air conditioning equipment Heating/cooling two-way switch RAMSES 709 Also suitable for air conditioning equipment Heating/cooling two-way switch 3-way selector switch for: comfort mode, reduction mode, external reduction Indicator lamp Integrated temperature reduction (approx. 4 K) possible via control with timer Product selection Connection type Type of contact Switching capacity at 230 V AC Setting range Operating voltage Type Article number 2/3 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC RAMSES 701 7010001 3/4 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC 4/5 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC 3/4 conductors Two way switch 4/5 conductors Two way switch Heating: 10 (4) A Cooling: 5 (2) A Heating: 10 (4) A Cooling: 5 (2) A RAMSES 702 7020001 RAMSES 703 7030001 RAMSES 704 7040001 RAMSES 705 7050001 RAMSES 706 7060001 RAMSES 707 7070001 +5 C +30 C 230 240 V AC RAMSES 708 7080001 +5 C +30 C 230 240 V AC RAMSES 709 7090001 http Additional technical data at: 154 www.theben.de/product/ Article number

CIMATE Room thermostats Mechanical Technical data RAMSES 701 RAMSES 702 RAMSES 703 RAMSES 704 RAMSES 705 RAMSES 706 RAMSES 707 RAMSES 708 RAMSES 709 Operating voltage 230 240 V AC Frequency 50 60 Hz Type of contact C contact Two way switch Switching capacity 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6),, Setting range +5 C +30 C Control accuracy approx. 1 K, thermal recirculation Test approvals V Colour Pure white (similar to RA 9010) Installation type Surface-mounted Type of protection IP 30 Protection class II in accordance with E 60 730-1 Heating: 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Cooling: 5 A (at 230 V AC, cos = 1), 2 A (at 230 V AC, cos = 0.6) Accessories Scale drawings Adapter plate RAMSES 70x Art.o.: 9070480 Details Page 236 75 28 24 5,5 70,7 9 Connection example RAMSES 701 RAMSES 702, RAMSES 703 RAMSES 704 RAMSES 705 2 1 RF > 5 2 1 TA > RF 6 5 2 RF > 6 5 2 TA > RF RAMSES 706 RAMSES 707 RAMSES 708 RAMSES 709 6 5 2 TA > RF 6 5 2 RF > 3 2 1 > RF 5 3 2 1 TA > RF httpadditional technical data at: www.theben.de/product/ Article number 155

Room thermostats Mechanical CIMATE Mechanical room thermostat RAMSES 741 RAMSES 741 RA RAMSES 746 RA Description 9 Common functions Room temperature controller with thermal feedback Setting controller with mechanical setting limit or detection Central part ts nearly all frames using an adapter frame from the switch manufacturer Ideal controller for refurbished and new build properties RAMSES 741 Supplied as replacement device without frame, central part and setting button, incl. protective cap Frame, central part and setting button available as accessories RAMSES 746 Switch for heating O/OFF + indicator lamp External temperature reduction (approx. 4 K) possible via control with timer Supplied as replacement device without frame, central part and setting button, incl. protective cap Frame, central part and setting button available as accessories RAMSES 748 Heating/cooling two-way switch Supplied as replacement device without frame, central part and setting button, incl. protective cap Frame, central part and setting button available as accessories RAMSES 741 RA With frame, central part and setting button RAMSES 746 RA External temperature reduction (approx. 4 K) possible via control with timer With frame, central part and setting button Switch for heating O/OFF + indicator lamp RAMSES 748 RA Heating/cooling two-way switch With frame, central part and setting button Product selection Scope of delivery Connection type Type of contact Switching capacity at 230 V AC Without cover With cover Setting range Operating voltage Type Article number 2/3 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC RAMSES 741 7410130 4/5 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC RAMSES 746 7460130 3/4 conductors Two way switch Heating: 10 (4) A Cooling: 5 (1) A +5 C +30 C 230 240 V AC RAMSES 748 7480130 2/3 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC RAMSES 741 RA 7410131 4/5 conductors C contact 10 (4) A +5 C +30 C 230 240 V AC RAMSES 746 RA 7460131 3/4 conductors Two way switch Heating: 10 (4) A Cooling: 5 (1) A +5 C +30 C 230 240 V AC RAMSES 748 RA 7480131 http Additional technical data at: 156 www.theben.de/product/ Article number

CIMATE Room thermostats Mechanical Technical data RAMSES 741 RAMSES 746 RAMSES 748 RAMSES 741 RA RAMSES 746 RA RAMSES 748 RA Operating voltage 230 240 V AC Frequency 50 60 Hz Type of contact C contact Two way switch C contact Two way switch Max. switching capacity 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Heating: 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Cooling: 5 A (at 230 V AC, cos = 1), 1 A (at 230 V AC, cos = 0.6) 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Heating: 10 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Cooling: 5 A (at 230 V AC, cos = 1), 1 A (at 230 V AC, cos = 0.6) Setting range +5 C +30 C Control accuracy approx. 0.5 K, thermal recirculation Test approvals V Colour Pure white shiny (similar to RA 9010) Installation type Flush-mounted Type of protection IP 30 Protection class II in accordance with E 60 730-1 Accessories Scale drawings Additional accessories Central part RAMSES 741/748 Details Page 238 Central part RAMSES 746 Details Page 239 Frame RAMSES 74x Details Page 238 RAMSES 741, RAMSES 746, RAMSES 748 80,5 56 70,6 50 50,5 45 24,5 19 9 60 Connection example RAMSES 741, RAMSES 741 RA RAMSES 746, RAMSES 746 RA RAMSES 748, RAMSES 748 RA > TA > TA > RF RF RF httpadditional technical data at: www.theben.de/product/ Article number 157

Room thermostats Electronic CIMATE Electronic room thermostats ush-mounted RAMSES 714 RAMSES 714 A RAMSES 751 RA Description 9 RAMSES 714 Electronic room thermostats for all types of heating, e. g. gas, water, electric heating etc. Individual room control possible in combination with Theben actuators Heating status display via ED External temperature reduction (approx. 3.5 K) is possible via control with timer Temperature reduction can be cut to 2 K by opening a wire bridge RAMSES 714 A ike RAMSES 714, however: External temperature sensor for under oor heating (wet rooms or bathroom heating) Switchable for the connection of available TC sensors (33 K /25 C) Switch for heating O/OFF RAMSES 714 A/FH ike RAMSES 714 A, however: Equipped with selectable under oor heating temperature limits 40 C (tiles) or 30 C (laminates, wood, cork) o sensor changeover RAMSES 751 RA Electronic room temperature controller with remote temperature sensor for under- oor temperature control Display of temperature reduction and heating O 2-pole mains switch for heating O/OFF Emergency mode in case of sensor failure with 30 % heating Setting controller with mechanical setting limit or detection External temperature reduction (3 or 5 K) possible via control with timer Central part ts nearly all frames using an adapter frame from the switch manufacturer Product selection Connection type Type of contact Switching capacity at 230 V AC Setting range Installation type Type Article number 2/3 conductors C contact 8 A (at 230 V AC, cos = 1) +5 C +30 C Surface-mounted RAMSES 714 7140002 +10 C +60 C Surface-mounted RAMSES 714 A 7140016 4/5 conductors C contact 16 A (at 230 V AC, cos = 1) +5 C +40 C Surface-mounted RAMSES 714 A/FH 7140017 5 conductor O contact 16 (4) A +10 C +50 C Flush-mounted RAMSES 751 RA 7510131 http Additional technical data at: 158 www.theben.de/product/ Article number

CIMATE Room thermostats Electronic Technical data RAMSES 714 RAMSES 714 A RAMSES 714 A/FH RAMSES 751 RA Operating voltage 230 V AC Frequency 50 Hz Type of contact C contact O contact Max. switching capacity 8 A (at 230 V AC, cos = 1) 16 A (at 230 V AC, cos = 1) 16 A (at 230 V AC, cos = 1), 4 A (at 230 V AC, cos = 0.6) Setting range +5 C +30 C +10 C +60 C +5 C +40 C +10 C +50 C Control accuracy ± 0.25 K ± 0.5 K Control mode Proportional controller with PWM (continuous type) Colour Pure white (similar to RA 9010) Installation type Surface-mounted Flush-mounted Type of protection IP 20 IP 30 Protection class II in accordance with E 60 730-1 Accessories Actuator APHA 4 230 V Art.o.: 9070438 Details Page 238 Actuator APHA 4 24 V Art.o.: 9070439 Details Page 238 Adapter plate RAMSES 714 For RAMSES 714, RAMSES 714 A, RAMSES 714 A/FH Art.o.: 9070212, Details Page 236 Scale drawings RAMSES 714 28 RAMSES 714 A, RAMSES 714 A/FH 32,6 RAMSES 751 RA 80,5 9 23,3 27,9 70,6 74 5 74 5 56 45 50 28 17 67 67 5 4 3 2 f 50,5 60 Connection example RAMSES 714 RAMSES 714 A, RAMSES 714 A/FH RAMSES 751 RA 8 A 16 A C1 C1 1 2 3 1 2 3 httpadditional technical data at: www.theben.de/product/ Article number 159

CIMATE http Additional technical data at: www.theben.de/product/ Article number 160

Section overview CIMATE Sensor technology Description Type Page Sensor technology CO 2 sensor with USB interface Graphic display of CO 2 levels on PC AMU 716 USB 162 CO 2 sensor for ventilation control and monitoring of air quality in the room with switch and analog outputs AMU 716 R 162 Hygrostat for wall installation for control of humidi ers or ventilation and dehumidi er systems SOTHIS 715 164 10 httpadditional technical data at: www.theben.de/product/ Article number 161

Sensor technology Sensor technology CIMATE CO 2 sensors AMU 716 USB AMU 716 R Description 10 Common functions CO 2 sensor Suitable for conference and meeting rooms, of ces, schools/nurseries, passive and low-energy housing. AMU 716 USB Simple installation and start-up on PC via USB interface Software for Windows 98 SE/ME/2000/XP Acoustic and visual warning signals on reaching the threshold value Product selection og le of CO 2 level can be saved Saves automatically during extended recordings Graphic display of CO 2 levels on PC Representation of course of last 80 minutes using diagrams Additional display of current CO 2 level on directly sensor via 5 EDs Adjustable acoustic alarm threshold AMU 716 R For fan control Warning display for CO 2 concentration (lights) Power unit optionally available. Power unit is suitable for ush mounted installation Simple upgrade of uncontrolled ventilation systems possible 2 switch outputs CO 2 controlled for 2 stage control, with manual and automatic mode as well as display of switching status 3 x 0 10 V outputs for CO 2, temperature and relative humidity Measuring range Data interface Display Protection class Type Article number 0 2000 ppm *Available May 2010 USB 5 EDs III in accordance with E 60 730-1 AMU 716 USB 7169101 3 x 0 10 V, 2 x Relay 6 EDs II in accordance with E 60 730-1 AMU 716 R 7160101 * http Additional technical data at: 162 www.theben.de/product/ Article number

CIMATE Sensor technology Sensor technology Technical data AMU 716 USB AMU 716 R Operating voltage 5 V DC via USB bus voltage 24 V DC SEV Outputs USB 3 x 0 10 V, 2 x Relay Max. switching capacity 5 A Measuring range CO 2 0 2000 ppm Measuring range temperature +5 C +40 C Measuring range humidity 20 100 % rh Hysteresis ± 75 ppm, in relation to set value Switched threshold 700 ppm ±200 ppm, 1300 ppm ±200 ppm Connection type USB, cable length 1.5 m Display 5 EDs 6 EDs Installation type Wall installation (also on ush-mounted housing) Type of protection IP 20 Protection class III in accordance with E 60,730-1 II in accordance with E 60 730-1 Accessories Scale drawings Power unit CO 2 sensor Details Page 236 AMU 716 USB 80 30,8 AMU 716 R 95 30 120 97 10 httpadditional technical data at: www.theben.de/product/ Article number 163

Sensor technology Sensor technology CIMATE SOTHIS 715 Description Hygrostat for wall installation Measurement of relative humidity. Suitable for control of humidi ers or ventilation and dehumidi er systems Use SEV where there is a risk of high humidity and the build up of condensation Product selection Measuring range Type of contact Switching capacity Humidi er Switching capacity Dehumidifying Type Article number 35 100 % rf Two way switch 2 A 5 A SOTHIS 715 7150002 Technical data SOTHIS 715 Operating voltage Frequency Max. switching capacity Dehumidifying Max. switching capacity Humidi er 230 V AC 50 60 Hz 5 A 2 A Colour Pure white (similar to RA 9010) Installation type Wall installation Type of protection IP 30 Protection class II in accordance with E 60 730-1 10 Accessories: Adapter plate RAMSES 714 Art.o.: 9070212 Details Page 236 Scale drawings 74 5 28 23,3 Connection example 4 2 1 67 1 2 http Additional technical data at: 164 www.theben.de/product/ Article number

CIMATE Sensor technology Sensor technology 10 httpadditional technical data at: www.theben.de/product/ Article number 165

SYSTEMS http Additional technical data at: 166 www.theben.de/product/ Article number

Section overview SYSTEMS KX Actuators Dimming actuators Designation Type page Actuators C load 4-12 channels MIX 2 RMG 4 I KX/RME 4 I KX 168 Actuators 8-24 channels MIX 2 RMG 8 S KX/RME 8 S KX 169 Actuators C load 4-12 channels MIX 1 RMG 4 C-oad KX/RME 4 C-oad KX 170 Actuators 4-12 channels MIX 1 RMG 4 S KX/RME 4 S KX 171 Switch or blind actuators 4-16 channels RMG 8 KX/RME 8 KX 172 Control units 2-6 channels MIX 1 SMG 2 S KX/SME 2 S KX 173 Universal dimming actuators 2-6 channels MIX 1 DMG 2 S KX/ DME 2 S KX/DMB 2 S KX 174 Blind actuators Blind actuators 4-12 channels MIX 1 JMG 4 S KX/JME 4 S KX 176 Blind actuators 4-12 channels JMG 4 24V DC KX/JME 4 24V DC KX 177 Binary inputs Binary inputs 6-18 channels MIX 1 BMG 6 KX/BME 6 KX 178 Binary inputs for ush-mounted sockets TA 2 KX/TA 4 KX/TA 6 KX 179 Heating and air conditioning control multifunction display VARIA 826 KX/824 KX 180 Room thermostat and individual room thermostat RAMSES 770 KX/713 S KX/712 KX 181 Heating actuators HMG 4 KX/HME 4 KX/HMT 6 KX/HMT 12 KX 184 Motor-driven actuators CHEOPS control KX/ CHEOPS drive KX 186 CO 2 Room air sensor AMU 716 KX 187 Individual room thermostat Fan-Coil and Fan-Coil actuator RAMSES 713 FC KX/FCA 1 KX 188 Presence and motion detectors Motion detector SPHIX 331 KX/332 KX/105-300 KX 190 Weather station, brightness sensors Time switches System devices Display units Passive infrared presence detector compact of ce EIB/compact passage KX/compact passimo KX/ECO-IR 180EIB-AC ECO-IR 360EIB-AC/ECO-IR DUA-EIB KX weather stations KX weather station/kx weather station basic 200 Brightness sensors and temperature sensors UA 130 KX/131 KX/133 KX 201 4 channel time switches with annual program TR 644 S DCF KX/TR 644 S KX 204 2 channel time switch with weekly program TR 612 S KX 206 Time signal transmitter ZS 600 DF KX 207 Supply voltage Power supply 640 ma/320 ma/160 ma 208 Interface and line coupler USB interface KX/ line coupler KX 209 192 11 KX indoor clock OSIRIA 210 httpadditional technical data at: www.theben.de/product/ Article number 167 167

Switch actuators KX SYSTEMS Actuators C load 4 12 channels MIX 2 RMG 4 I KX RME 4 I KX Description Common functions 4-way C load switching actuator MIX 2 With current recognition For higher lamp loads Up to two extension modules MIX 1 or MIX 2 can be connected to one basic module Device and KX bus module can be swapped independently of each other Removable KX bus module enables devices to be changed without reprogramming Product selection Manual set-up and use of switching actuators is possible without KX bus module ED switching status display for each channel Manual operation on device (even without bus connection) Switching functions: E.g. On/Off, pulse, On/ Off delay, staircase light with warning ogical links: e.g. lock, AD, release, OR Technical data RMG 4 I KX Basic module MIX 2 Can be upgraded to maximum of 12 channels RME 4 I KX Extension module MIX 2 For upgrading to maximum of 12 channels 11 Type Article number RMG 4 I KX 4930210* RME 4 I KX 4930215* *Available June 2010 Connection example RMG 4 I KX RMG 4 I KX RME 4 I KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 100 240 V AC, 0 65 Hz Power consumption 3 VA 2.5 VA Width 4 modules Type of contact O contact, 16 A (at 250 V AC, cos = 1), 16 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 RME 4 I KX 3 4 5 6 3 4 5 6 C1 C2 C1 C2 7 8 9 10 C3 C4 KX 7 8 9 10 C3 C4 http Additional technical data at: 168 www.theben.de/product/ Article number

SYSTEMS Switch actuators KX Actuators 8 24 channels MIX 2 RMG 8 S KX RME 8 S KX Description Common functions 8-way switching actuator MIX 2 Up to two extension modules MIX 1 or MIX 2 can be connected to one basic module Device and KX bus module can be swapped independently of each other Removable KX bus module enables devices to be changed without reprogramming Manual set-up and use of switching actuators is possible without KX bus module ED switching status display for each channel Manual operation on device (even without bus connection) Switching functions: E.g On/Off, pulse, On/ Off delay, staircase light with warning ogical links: e.g. lock, AD, release, OR RMG 8 S KX Basic module MIX 2 Can be upgraded to maximum of 24 channels RME 8 S KX Extension module MIX 2 For upgrading to maximum of 24 channels Product selection Technical data Type Article number RMG 8 S KX 4930220* RME 8 S KX 4930225* *Available June 2010 Connection example RMG 8 S KX RMG 8 S KX RME 8 S KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 100 240 V AC, 0 65 Hz Power consumption 3.6 VA 3 VA Width 4 modules Type of contact O contact, 16 A (at 250 V AC, cos = 1), 3 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 RME 8 S KX 11 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 C1 C2 C3 C4 C1 C2 C3 C4 11 12 13 14 15 16 17 18 C5 C6 C7 C8 KX 11 12 13 14 15 16 17 18 C5 C6 C7 C8 httpadditional technical data at: www.theben.de/product/ Article number 169

Switch actuators KX SYSTEMS Actuators C load 4 12 channels MIX 1 RMG 4 C-oad KX RME 4 C-oad KX Description Common functions 4-way C load switching actuator MIX 1 For higher lamp loads Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs Product selection ED switching status display for each channel Manual switch with On/Off/Bus settings (also without bus voltage) Switching functions: e.g. On/Off, pulse, On/ Off delay, staircase light with warning ogical links: e.g. lock,ad, release, OR Technical data RMG 4 C-oad KX Basic module MIX 1 Can be upgraded to maximum of 12 channels RME 4 C-oad KX Extension module MIX 1 For upgrading to maximum of 12 channels 11 Type Article number RMG 4 C-oad KX 4910206 RME 4 C-oad KX 4910207 RMG 4 C-oad KX RME 4 C-oad KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2.5 VA Width 4 modules Type of contact O contact, 16 A (at 250 V AC, cos = 1), 16 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Connection example RMG 4 C-oad KX RME 4 C-oad KX 3 4 5 6 7 8 9 10 C1 C2 C3 C4 3 4 5 6 7 8 9 10 C1 C2 C3 C4 KX http Additional technical data at: 170 www.theben.de/product/ Article number

SYSTEMS Switch actuators KX Actuators 4 12 channels MIX 1 RMG 4 S KX RME 4 S KX Description Common functions 4-way switching actuator MIX 1 Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs Product selection ED switching status display for each channel Manual switch with On/Off/Bus settings (also without bus voltage) Switching functions: e.g. On/Off, pulse, On/ Off delay, staircase light with warning ogical links: e.g. lock,ad, release, OR Technical data RMG 4 S KX Basic module MIX 1 Can be upgraded to maximum of 12 channels RME 4 S KX Extension module MIX 1 For upgrading to maximum of 12 channels Type Article number RMG 4 S KX 4910204 RME 4 S KX 4910205 RMG 4 S KX RME 4 S KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2.5 VA Width 4 modules Type of contact O contact, 16 A (at 250 V AC, cos = 1), 10 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 11 Connection example RMG 4 S KX RME 4 S KX 3 4 5 6 7 8 9 10 C1 C2 C3 C4 3 4 5 6 7 8 9 10 C1 C2 C3 C4 KX httpadditional technical data at: www.theben.de/product/ Article number 171

Switch actuators KX SYSTEMS Switch or blind actuators 4 16 channels RMG 8 KX RME 8 KX Description Common functions 4-way blind or 8-way switching actuator Flexible channel function selection: As switching actuator or for controlling drives for blinds, shutters, sun and vision protection devices, skylights and ventilation aps Manual operation on device ED switching status display on device Manual switch for Up/Down or for Switching On/Off (also without bus voltage) Optimised repetition accuracy of programmed lamella positions Slip correction when moving from bottom to top RMG 8 KX Basic module Upgradeable to 8 blind or 16 switching outputs RME 8 KX Extension module Upgradeable to 8 blind or 16 switching outputs Product selection Technical data 11 Type Article number RMG 8 KX 4900251 RME 8 KX 4900252 RMG 8 KX RME 8 KX Operating voltage KX Bus voltage, (< 8 ma) Operating voltage 230 240 V AC, 50 Hz Power consumption 4 VA Width 6 modules Type of contact O contacts, 10 A (at 250 V AC, cos = 1), 6 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Connection example RMG 8 KX RME 8 KX 2 3 6 7 2 3 6 7 C1.1 C1.2 C2.1 C2.2 C1.1 C1.2 C2.1 C2.2 C3.1 10 C3.2 11 C4.1 C4.2 14 15 KX C3.1 10 C3.2 11 C4.1 C4.2 14 15 http Additional technical data at: 172 www.theben.de/product/ Article number

SYSTEMS Dimming actuators KX Control units 2 6 channels MIX 1 SMG 2 S KX SME 2 S KX Description Common functions 2-way 1 10 V control unit MIX 1 Switching and dimming of lighting circuits in combination with electronic ballasts (EBs) Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Product selection Free combination of switches, dimming, blinds and heating control as well as binary inputs 1 10V control inputs and one switch output (relay contact) per channel ED switching status display for each channel Manual switch with On/Off/Bus settings (also without bus voltage) Technical data With zero-cross switching for switching without relays SMG 2 S KX Basic module MIX 1 Can be upgraded to maximum of 6 channels SME 2 S KX Extension module MIX 1 For upgrading to maximum of 6 channels Type Article number SMG 2 S KX 4910273 SME 2 S KX 4910274 SMG 2 S KX SME 2 S KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2 VA Width 4 modules Type of contact O contacts, 16 A (at 250 V AC, cos = 1), 10 A (at 250 V AC, cos = 0.6) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 11 Connection example SMG 2 S KX 1 2 3 4 EVG + 1 3 C1 4 + 7 8 + C1 C2 C2 + 1 EVG 1 2 3 4 KX httpadditional technical data at: www.theben.de/product/ Article number 173

Dimming actuators KX SYSTEMS Universal dimming actuators 2 6 channels MIX 1 DMG 2 S KX DME 2 S KX DMB 2 S KX Description Common functions 2-way universal dimmer actuator MIX 1 For dimming incandescent lamps, V and HV halogen lamps Also suitable for switching of dimmable energy-saving lamps Also suitable for controlling fans Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs Product selection Dimming output: 2 x 300 W/VA or 1 x 500 W/VA If the DMB 2 'dim booster' is used, the dimming output per device can be doubled to: 2 x 600 W/VA or 1 x 1,000 W/VA ED switching status display for each channel Manual switch with On/Off/Bus settings (also without bus voltage) Automatic load detection (can be deactivated) DMG 2 S KX Basic module MIX 1 Can be upgraded to maximum of 6 channels DME 2 S KX Extension module MIX 1 For upgrading to maximum of 6 channels DMB 2 S KX 2 channel dimming output upgrade 'Dimmbooster' To double the output of basic and extension modules. e.g. to: 2 x 600 W/VA (1 channel) or 1 x 1,000 W/ VA (2 channels) ED switching status display for each channel 11 Type Article number DMG 2 S KX 4910270 DME 2 S KX 4910271 DMB 2 S KX 4910272 Technical data DMG 2 S KX DME 2 S KX DMB 2 S KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 1 VA 0.5 VA Width 4 modules amp types Incandescent lamps, low-voltage and high-voltage halogen lights, dimmable Compact energy saving lamps Incandescent lamps, low-voltage and high-voltage halogen lights http Additional technical data at: 174 www.theben.de/product/ Article number

SYSTEMS Dimming actuators KX DMG 2 S KX DME 2 S KX DMB 2 S KX Min. switching capacity 10 W/VA 300 W Max symmetrical switching capacity 2 x 300 W/VA Upgrade to 2 x 300 W/VA Max asymmetrical switching capacity 1 x 500 W/VA Upgrade to 1 x 500 W/VA Switching capacity energy saving lamps max. 2 x 60 W or 1 x 100 W Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Connection example DMG 2 S KX DME 2 S KX 1 2 C1 3 4 C2 1 2 C1 3 4 C2 KX 500 W 500 W DMG 2 S KX DME 2 S KX 1 2 C1 3 4 C2 1 2 C1 3 4 C2 KX 300 W 300 W 300 W 300 W 11 DMB 2 S KX 1 2 3 4 1 2 3 4 C1 C2 C1 C2 DMG 2 KX DMB 2 KX KX 600 W 600 W httpadditional technical data at: www.theben.de/product/ Article number 175

Blind actuators KX SYSTEMS Blind actuators 4 12 channels MIX 1 JMG 4 S KX JME 4 S KX Description Common functions 4-way blind actuator MIX 1 For controlling drives for blinds, shutters, sun and vision protection devices, skylights and ventilation aps Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs Manual operation on device (even without bus connection) ED Up and Down switching status display for each channel Floating contacts for Up and Down per channel Copy function for fast con guration JMG 4 S KX Basic module MIX 1 Can be upgraded to maximum of 12 channels JME 4 S KX Extension module MIX 1 For upgrading to maximum of 12 channels Product selection Technical data Type Article number JMG 4 S KX 4910250 JME 4 S KX 4910251 JMG 4 S KX JME 4 S KX Operating voltage KX Bus voltage, (< 8 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2.5 VA Width 4 modules 11 Type of contact O contact, 3 A (at 250 V AC, cos = 1) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Connection example JMG 4 S KX JME 4 S KX M M M M C1 C2 C1 C2 KX C3 C4 C3 C4 M M 1 2 http Additional technical data at: 176 www.theben.de/product/ Article number M M

SYSTEMS Blind actuators KX Blind actuators 4 12 channels JMG 4 24V DC KX JME 4 24V DC KX Description Common functions 4-way DC blind actuator For controlling 24 V and 12 Vdrives in internal blinds and sun blinds Manual operation on device ED switching status display on device Manual switch for Up / Down or for Switching On / Off (also without bus voltage) Optimised repetition accuracy of programmed lamella positions Slip correction when moving from bottom to top Response on bus/mains failure con gurable 3 security objects (ED display) JMG 4 24V DC KX Basic module Can be upgraded to maximum of 8 channels JME 4 24V DC KX Extension module For upgrading to maximum of 8 channels Product selection Technical data Type Article number JMG 4 24V DC KX 4900253 JME 4 24V DC KX 4900254 JMG 4 24V DC KX JME 4 24V DC KX Operating voltage KX Bus voltage, (< 8 ma) Operating voltage 230 V AC, 50 Hz Power consumption 4 VA Width 6 modules Type of contact O contacts, 5 A (at 24 V DC), 5 A (at 12 V DC) Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 11 Connection example JMG 4 24V DC KX JME 4 24V DC KX 2 3 6 7 2 3 6 7 C1.1 C1.2 C2.1 C2.2 C1.1 C1.2 C2.1 C2.2 C3.1 10 C3.2 11 C4.1 C4.2 14 15 KX C3.1 10 C3.2 11 C4.1 C4.2 14 15 httpadditional technical data at: www.theben.de/product/ Article number 177

Binary inputs KX SYSTEMS Binary inputs 6 18 channels MIX 1 BMG 6 KX BME 6 KX Description Common functions 6-way binary input MIX 1 Multi-voltage input 8-250 AC/DC or auxiliary supply from device (approx. 18V AC / 20mA) Floating inputs Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs All inputs can be operated with different voltages Free allocation of functions: Switch/key, dimming, blinds, valuator, counter ED switching status display for each input BMG 6 KX Basic module MIX 1 Can be upgraded to maximum of 18 channels BME 6 KX Extension module MIX 1 For upgrading to maximum of 18 channels Product selection Technical data 11 Type Article number BMG 6 KX 4910230 BME 6 KX 4910231 Connection example BMG 6 KX BMG 6 KX BME 6 KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2.5 VA Width 4 modules Voltage/power consumption inputs 8 250 V AC/DC 3 ma Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 BME 6 KX 8 V AC/DC 8 V AC/DC 7 8 9 10 11 12 I1 I2 I3 7 8 9 10 11 12 I1 I2 I3 3 4 5 6 3 4 5 6 KX I4 I5 I6 13 14 15 16 17 18 I4 I5 I6 13 14 15 16 17 18 http Additional technical data at: 178 www.theben.de/product/ Article number

SYSTEMS Binary inputs KX Binary inputs for ush-mounted sockets TA 2 KX TA 4 KX TA 6 KX Description Common functions Binary input/binary output sensor interfaces Can be installed in ush-mounted sockets with conventional sensors/switches Free allocation of functions: Switch/key, dimming, blinds, valuator Inputs can be recon gured to outputs: binary input: oating contact binary output: 1 ma (low current) (ED 1 ma types) Grooves on side of housing for switch/ sensor clamps TA 2 KX 2-way key interface 4-pole cable connection TA 4 KX 4-way key interface 8-pole cable connection TA 6 KX 6-way key interface 8-pole cable connection Product selection Technical data Type Article number TA 2 KX 4969202 TA 4 KX 4969204 TA 6 KX 4969206 TA 2 KX TA 4 KX TA 6 KX Operating voltage KX Bus voltage, (< 10 ma) Output con guration ED ow current 1 ma (ED 1 ma types) without series resistor Contact voltage 3.3 V Contact current 0.5 ma Interface extension max. 5 m Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 11 Connection example TA 2 KX TA 4 KX TA 6 KX C1 C2 C1 C2 C3 C4 C1 C2 C3 C4 C5 C6 KX KX KX httpadditional technical data at: www.theben.de/product/ Article number 179

Heating and air conditioning control KX SYSTEMS Multifunction display VARIA 826 KX VARIA 826 KX VARIA 824 KX Description Common functions Multi-functional display with room thermostat Freely con gurable for displaying and controlling functions e.g. light settings, sun protection systems Illuminated display and integrated timer For control and regulation of heating, fan coils, air conditioning systems Up to 7 different display pages Can also be operated without 230 V connection (double power consumption from bus system) Product selection Automatic summer/winter time adjustment with power reserve Controls up to 8 rooms via own temperature pro les Weekly time switch with 8 channels with up to 3 different statuses, e.g. for light, shutters, fans etc. 3 heating programs Alternative continuous or on/off control Operation modes: comfort, standby, temperature reduction at night, frost protection Technical data Weather information from the Theben weather station can be displayed Free choice of programming via the ETS without plug-in Installation in ush-mounted socket VARIA 826 Glass front in white or black VARIA 824 White plastic housing 11 Colour Type Article number Glass front in white VARIA 826 KX 8269200 Glass front in black VARIA 826 KX 8269201 White plastic housing VARIA 824 KX 8249200 Operating voltage KX Operating voltage Power consumption Power reserve Display VARIA KX Bus voltage, (< 8 ma) 230 V AC, 50 Hz 2.5 VA 1.5 years display with 132 x 72 points (8 lines with various functions) e.g. title, switching, dimming, blinds/shutters, % value, HVAC, counter value, temperature, 2-byte value, 8/16 bit counter value etc. Ambient temperature +0 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Scale drawings VARIA 826 KX VARIA 824 KX 45,6 18,1 128 4 118 17 93,4 80 http Additional technical data at: 180 www.theben.de/product/ Article number

SYSTEMS Heating and air conditioning control KX RAMSES 770 KX Description Room thermostat For control and regulation of heating, fan coils, air conditioning systems Illuminated display Settings with text guidance Automatic summer/winter time changeover 3 heating programs Alternative continuous or on/off control Operation modes: comfort, standby, temperature reduction at night, frost protection Free choice of programming via the ETS without plug-in Installation in ush-mounted socket External time signal is necessary for synchronisation Product selection Type Article number RAMSES 770 KX 7709200 Technical data RAMSES 770 KX Operating voltage KX Bus voltage, (< 10 ma) Ambient temperature +0 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 669 Scale drawings 82,8 36,3 12,4 80,8 11 httpadditional technical data at: www.theben.de/product/ Article number 181

Heating and air conditioning control KX SYSTEMS RAMSES 713 S KX Description Individual room thermostat For controlling heating actuators or motorised actuators Can be used as a continuous or two point control (can also be combined). Continuous PI control can be con gured for 2 stage heating (basic and additional stage, e. g. under oor heating and radiators) or for heating and cooling (radiators and cooling surfaces) Two rotary controls are included in the scope of supply: a numerical scale (mounted) and 1 relative scale (enclosed) Rotary control can be limited mechanically or via parameters. Manual overide button for presence or operation modes: comfort, standby, temperature reduction at night, frost protection 3 binary inputs for conventional switches/ sensors (switching, dimming, blinds), also for external temperature sensor, window contact or presence signal Temperature sensor can be connected to give remote temperature reading ED (red) for heating mode, (blue) for cooling mode With integrated bus coupling unit Product selection Type Article number RAMSES 713 S KX 7139201 Technical data RAMSES 713 S KX Operating voltage KX Bus voltage (< 10 ma) Ambient temperature +0 C +50 C Measuring range temperature +0 C +40 C Adjustable temperature +10 C +28 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Scale drawings 11 External temperature sensor 1 Art.o.: 9070191 Details Page 237 Temperature sensor Art.o.: 9070321 Details Page 237 80 27 84 http Additional technical data at: 182 www.theben.de/product/ Article number

SYSTEMS Heating and air conditioning control KX RAMSES 712 KX Product selection Description Individual room thermostat For controlling heating actuators or motorised actuators Can be used as a continuous or two point control (can also be combined). Temperature sensor can be connected give remote temperature reading Objects for night operation (only with "old" operation mode selection) presence, window/frost ED (red) for heating mode Inputs can be recon gured to outputs for connecting ED (ED 1 ma types) 2 binary inputs for conventional switches/ sensors (switch/sensor, dimmer, blinds, valuator, ED control) Can be installed in ush-mounted sockets (temperature sensor with electronic component can be removed from housing and installed in ush-mounted sockets with back-ventilated cover) With integrated bus coupling unit Type Article number RAMSES 712 KX 7129200 Technical data RAMSES 712 KX Operating voltage KX Bus voltage (< 10 ma) Output con guration ED ow current 1 ma (ED 1 ma types) Interface extension max. 5 m Ambient temperature 5 C +45 C Measuring range temperature 20 C +60 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Temperature sensor Art.o.: 9070321 Details Page 237 Adapter plate RAMSES 70x Art.o.: 9070480 Details Page 236 11 Scale drawings 74 23,3 5 67 httpadditional technical data at: www.theben.de/product/ Article number 183

Heating and air conditioning control KX SYSTEMS Heating actuators 4 12 channels MIX 1 HMG 4 KX HME 4 KX Description Common functions 4-way heating actuator MIX 1 For controlling thermal actuators Silent semiconductor switch (triac) Up to 2 extension modules can be connected to a basic module. Can be combined with all MIX 1 series devices Free combination of switches, dimming, blinds and heating control as well as binary inputs Maximum control variables for integrating boiler control For integrating boiler control It is possible to control a circulation pump directly via the actuator. Up to 5 positioning actuators per channel Floating outputs 24 250 V AC Manual switch with On/Off/Bus settings (also without bus voltage) Switching status display for each channel With summer mode and valve protection Continuous or switching actuating value selectable HMG 4 KX Basic module MIX 1 Can be upgraded to maximum of 12 channels HME 4 KX Extension module MIX 1 For upgrading to maximum of 12 channels Product selection Technical data 11 Type Article number HMG 4 KX 4910210 HME 4 KX 4910211 HMG 4 KX HME 4 KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC, 50 Hz Power consumption 2.5 VA Width 4 modules Type of contact Triac, 0.5 A Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Actuator APHA 4 230 V Details Page 238 Actuator APHA 4 24 V Details Page 238 Connection example HMG 4 KX 3 4 5 6 7 8 9 10 H1 H2 H3 H4 HME 4 KX 3 4 5 6 7 8 9 10 H1 H2 H3 H4 KX http Additional technical data at: 184 www.theben.de/product/ Article number

SYSTEMS Heating and air conditioning control KX Heating actuators with triacs HMT 6 KX HMT 12 KX Description Common functions Heating actuator for controlling thermal actuators (24 V) Can be installed directly on a wall or a rail in the heating circuit distributor Mains plug on transformer for easy installation Screwless terminal technology Integrated power supply for a maximum of 13 thermal actuators Silent semiconductor switch (triac) For integrating boiler control Summer mode and valve protection Continuous or switching actuating value selectable HMT 6 KX 6-way heating actuator HMT 12 KX 12-way heating actuator Product selection Technical data Type Article number HMT 6 KX 4900273 HMT 12 KX 4900274 HMT 6 KX HMT 12 KX Operating voltage KX Bus voltage 10 ma Operating voltage 230 V AC, 50 60 Hz umber of channels 6 12 Type of contact Triac Fuse T 2 A Ambient temperature 5 C +50 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Actuator APHA 4 24 V Details Page 238 11 Connection example HMT 6 KX 1 2 3 4 5 6 KX httpadditional technical data at: www.theben.de/product/ Article number 185

Heating and air conditioning control KX SYSTEMS Motor-driven modulating actuators CHEOPS control KX CHEOPS drive KX Description Common functions Motorised actuator for heater valve or for controlling the heating valves Display of valve stroke Automatic valve stroke recognition 2 inputs for window contact, presence detector, remote sensor Simple installation by clicking onto valve adapter Can be used in heating circuit distributor Integrated bus coupling unit With summer mode and valve protection 2 different valve adapters included CHEOPS control KX Independent room thermostat and integrated temperature sensor Manual operation possible via 2 keys on the device Display via EDs (red/blue for hotter/colder) Con gurable as: Heating control (continuous control),two stage heating, heating and cooling CHEOPS drive KX Without integrated control Display via EDs (red) Product selection Technical data 11 Type Article number CHEOPS control KX 7329201 CHEOPS drive KX 7319200 CHEOPS control KX CHEOPS drive KX Operating voltage KX Bus voltage, (< 10 ma) Maximum valve stroke 7.5 mm Controlling torque value 120 Ambient temperature +0 C +50 C Protection class III according to E 60730-2-14 Protection rating IP 20 IP 21 Accessories External temperature sensor 1 Art.o.: 9070191 Details Page 237 Valve adapter VA 78 Art.o.: 9070436 Details Page 238 Valve adapter VA 80 Art.o.: 9070437 Details Page 238 http Additional technical data at: 186 www.theben.de/product/ Article number

SYSTEMS Heating and air conditioning control KX AMU 716 KX Description CO 2 air quality sensor Measures CO 2 level, relative humidity and temperature Three independent, con gurable thresholds for the CO 2 level and relative humidity A threshold for the temperature Actions can be carried out if thresholds are exceeded or not reached (send, priority, switching, value) Display of achieved threshold of CO ² level and relative humidity through multi-coloured EDs CO 2 Setting range of 500-2250 ppm (threshold) Relative humidity of 1% to 100% "Physical value" object of 0 9999 ppm Power supply via KX bus voltage, 230 V mains supply not required Product selection Type Article number AMU 716 KX 7169200 Technical data AMU 716 KX Operating voltage KX Bus voltage, (< 10 ma) Measuring range CO 2 500 2550 ppm Measuring range temperature +0 C +40 C Measuring range humidity 20 100 % rh Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Adapter plate RAMSES 70x Art.o.: 9070480 Details Page 236 11 Scale drawings 74 23,3 5 67 httpadditional technical data at: www.theben.de/product/ Article number 187

Heating and air conditioning control KX SYSTEMS RAMSES 713 FC KX Description Individual room thermostat fan coil For control of fan coil Continuous PI controller for heating and cooling Two rotary controls are included in the scope of supply: an absolute scale (mounted) and 1 relative scale (enclosed) Rotary control can be limited mechanically or via parameters. Manual button for OFF, Auto, fan stages 1, 2, 3 operation modes 3 binary inputs for conventional switches/ sensors (switching, dimming, blinds), also for external temperature sensor, window contact or presence signal ED (red) for heating mode, (blue) for cooling mode With integrated bus coupling unit Product selection Type Article number RAMSES 713 FC KX 7139202 Technical data RAMSES 713 FC KX Operating voltage KX Bus voltage (< 10 ma) Ambient temperature +0 C +50 C Measuring range temperature +0 C +40 C Adjustable temperature +10 C +28 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories External temperature sensor 1 Art.o.: 9070191 Details Page 237 Scale drawings 80 27 11 84 http Additional technical data at: 188 www.theben.de/product/ Article number

SYSTEMS Heating and air conditioning control KX FCA 1 KX Description Fan coil actuator For controlling fan coils For 2 and 4 pipe systems For up to three fan stages For 2-way and 3-way valves Additional relay for electrical heater or cooler bank Floating input for a window contact or temperature sensor Floating input, condensation monitoring Display of operation status via 9 EDs Manual operation on device (fan stages, switching between heating and cooling) Adjustment of setpoint value for cooling in relation to external temperature Floating switching contact for either cooler or heater bank With emergency program Product selection Type Article number FCA 1 KX 4920200 Technical data Operating voltage KX Operating voltage Power consumption Width Type of contact Switching capacity valves (triacs) Bus voltage, (< 10 ma) 230 V AC, 50 60 Hz 3 VA 4 modules Triac 0.5 A (24 230 V AC) FCA 1 KX Switching capacity, additional relay 16 A Switching capacity, ventilator relay 8 A Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories: External temperature sensor 1 Art.o.: 9070191 Details Page 237 Connection example S1 S2 S3 S 11 E1 E2 C- C+ C H H+ H- M M +C C1 httpadditional technical data at: www.theben.de/product/ Article number 189

Motion detectors KX SYSTEMS Motion detectors SPHIX 331, KX, SPHIX 332 KX Description Passive infrared motion detector For controlling lighting, ventilation etc., particularly in of ces and hallways Integrated bus coupling With constant light control ighting control "movement-dependent only " and "movement and brightness dependent" Continuous constant light control/movement-dependent the following functions: e.g. lighting O/ OFF, shutters/blinds UP/DOW, time functions (switch-off delay), locking the motion detector, call up setting, dimming values, dimming UP/DOW, Master/Slave function Flush tting design (projects 5 mm from ceiling) SPHIX 331 KX 1 channel motion detector SPHIX 332 KX 2 channel motion detector Additional programming keys can activate the phys. address via a programming magnet (if programming is executed after installation) Product selection Type Article number SPHIX 331 KX 1079211 SPHIX 332 KX 1079212 Technical data 11 SPHIX 331 KX SPHIX 332 KX Operating voltage KX Bus voltage, (< 10 ma) Detection range Ø 7 m at installation height of 2.8 m Brightness measuring range 0 700 lx (with correction factor to 5600 lx) ight switch-off delay 1 s 120 min Ambient temperature 5 C +45 C Protection rating IP 20 Scale drawings Detection range 68,7 4 37 3,6 Ø 76 2.8 m 7 m Ø 76 Ø 36,9 Ø 58,4 Ø 64/68 Area of high sensitivity 7 m Area of low sensitivity http Additional technical data at: Installation height 2.8 m 190 www.theben.de/product/ Article number

SYSTEMS Motion detectors KX SPHIX 105-300 KX Description SPHIX 105-300 KX 2 channel passive infrared motion detector For controlling lighting in outdoor areas Blended light measurement suitable for the control of uorescent, incandescent and halogen lamps Adjustable sensor head Additional creep under protection. via remote control Detection range can be limited using enclosed segments Settings per ETS: Brightness range and switch-off delay Set point adjustment of brightness either via object or potentiometer the following functions: ighting O/OFF, time functions, locking the motion detector ighting control with adjustable light threshold value and adjustable switch-off delay Memorising of current brightness value possible via remote control Setting controls protected against manipulation Single-handed plug-in installation with captive screws Product selection Type Article number SPHIX 105-300 KX 1059203* *Available May 2010 Technical data SPHIX 105-300 KX Operating voltage KX Detection range Brightness measuring range Bus voltage, < 10 ma Ø 5 30 m at installation height of 2.5 m 0 650 lx ight switch-off delay 1 s 120 min Ambient temperature 20 C +50 C Protection rating IP 55 Accessories Scale drawings SPHIX RC 105 Details Page 235 SPHIX RC 105 Pro Details Page 235 SPHIX corner angle Details Page 235 90 159 55 30 11 89 Detection area see page 109 httpadditional technical data at: www.theben.de/product/ Article number 191

Presence detector KX SYSTEMS compact of ce EIB Description Passive infrared presence detector (PIR) For controlling lighting, ventilation etc., particularly in of ces and hallways Square detection area Mixed light measurement The square detection area allows accurate and simple planning Two outputs light for controlling two lighting groups Switching or constant light control Choice of fully or semi automatic operation Presence output for HVAC control with switch on delay and switch-off delay Room monitoring Integrated bus coupling QuickSet plus service remote control (optional) Clic user remote control (optional) In the "Switching" operation mode, the lighting switches on with darkness and presence and off with suf cient light or absence. In the "constant light control" operation mode the sensor controls the arti cial light daylight-dependent on a constant lighting level The self-learning switch-off delay adjusts to occupants' behaviour Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The monitoring output works with reduced sensitivity and indicates the presence of persons with a high level of accuracy The brightness output makes the light information available for visualisation purposes Master or slave operating mode is selected via con guration. Test operation mode checks the detection range and con guration Product selection Colour Type Article number Pure white (similar to RA 9010) compact of ce EIB 2019200 Black (similar to RA 9005) compact of ce EIB BK 2019800 Silver (similar to RA 9006) compact of ce EIB SR 2019801 additional colours available upon request 11 Technical data compact of ce EIB Operating voltage KX Bus voltage Recommended installation height 2 3 m Brightness measuring range 10 1500 lx ight switch-off delay 30 s 20 min ight stand-by time 0 s 60 min Presence switch-off delay 30 s 120 min Presence switch on delay 0 s 30 min Ambient temperature +0 C +50 C Protection rating IP 40 http Additional technical data at: 192 www.theben.de/product/ Article number

SYSTEMS Presence detector KX Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 9 m² 3.0 m x 3.0 m 20 m² 4.5 m x 4.5 m ± 0.5 m A 0.8 ux 2.5 m 16 m² 4.0 m x 4.0 m 36 m² 6.0 m x 6.0 m ± 0.5 m B C 3 m 25 m² 5.0 m x 5.0 m 49 m² 7.0 m x 7.0 m ± 1.0 m 3.5 m 64 m² 8.0 m x 8.0 m ± 1.0 m Accessories QuickSet plus Art.o.: 9070532 Details Page 234 clic Details Page 233 Surface frame compact Art.o.: 9070514 Details Page 232 QuickSafe Art.o.: 9070531 Details Page 233 Scale drawings 102,5 70 60 29,5 102,5 33 26,5 4 56 11 11 httpadditional technical data at: www.theben.de/product/ Article number 193

Presence detector KX SYSTEMS Presence detectors compact passage KX, compact passimo KX compact passage KX compact passimo KX Description Common functions Passive infrared presence detector (PIR) For controlling lighting, ventilation etc., particularly in corridors and hallways Mixed light measurement The square detection range allows accurate and simple planning Two outputs light for controlling two lighting groups Switching or constant light control Choice of fully or semi automatic operation Presence output for HVAC control with switch on delay and switch-off delay Room monitoring Integrated bus coupling QuickSet plus service remote control (optional) Clic user remote control (optional) In the "Switching" operation mode, the lighting switches on with darkness and presence and off with suf cient light or absence. In the "constant light control" operation mode the sensor controls the arti cial light daylight-dependent on a constant lighting level The self-learning switch-off delay adjusts to occupants' behaviour Fully or semi-automatic: In "Fully automatic" mode, the lighting switches on and off automatically according to presence and light. In "Semi automatic" mode, it must be switched on manually and switches off automatically The monitoring output works with reduced sensitivity and indicates the presence of persons with a high level of accuracy The brightness output makes the light information available for visualisation purposes Master or slave operating mode is selected via con guration. Test operation mode checks the detection range and con guration compact passage KX Rectangular detection area for corridors compact passimo KX Rectangular detection area for storage areas with clear demarcation vertically below the presence detector Product selection 11 *Available May 2010 Colour Type Article number Pure white (similar to RA 9010) compact passage KX 2019290 Black (similar to RA 9005) compact passage KX BK 2019803 Silver (similar to RA 9006) compact passage KX SR 2019804 Pure white (similar to RA 9010) compact passimo KX 2019280* Black (similar to RA 9005) compact passimo KX BK 2019809* Silver (similar to RA 9006) compact passimo KX SR 2019810* additional colours available upon request http Additional technical data at: 194 www.theben.de/product/ Article number

SYSTEMS Presence detector KX Technical data compact passage KX, compact passimo KX Operating voltage KX Recommended installation height Brightness measuring range ight switch-off delay ight stand-by time Bus voltage 2 3 m 10 1500 lx 30 s 20 min 0 s 60 min Presence switch-off delay 30 s 120 min Presence switch on delay 0 s-30 min Ambient temperature +0 C +50 C Protection rating IP 40 Detection area compact passage KX (rectangular) Installation height (A) Head on to (r) Diagonally (t) A ux 2 m 56 m² 16 m x 3.5 m ± 1 m 105 m² 30 m x 3.5 m ± 1 m 2.5 m 72 m² 18 m x 4.0 m ± 1 m 120 m² 30 m x 4.0 m ± 1 m r t 3 m 90 m² 20 m x 4.5 m ± 1 m 135 m² 30 m x 4.5 m ± 1 m 3.5 m 100 m² 20 m x 5.0 m ± 1 m 150 m² 30 m x 5.0 m ± 1 m r t Detection area compact passimo KX (rectangular) Installation height (A) Head on to (r) Diagonally (t) A ux r t 2 m 28 m² 8 m x 3.5 m ± 1 m 53 m² 15 m x 3.5 m ± 1 m 2.5 m 36 m² 9 m x 4.0 m ± 1 m 60 m² 15 m x 4.0 m ± 1 m r t 3 m 45 m² 10 m x 4.5 m ± 1 m 68 m² 15 m x 4.5 m ± 1 m 3.5 m 50 m² 10 m x 5.0 m ± 1 m 75 m² 15 m x 5.0 m ± 1 m Accessories QuickSet: Details Page 232 clic: Details Page 231 QuickSafe: Details Page 231 Surface frame compact: Details Page 230 11 Scale drawings 44 102,5 17,5 19 25 45 70 60 102,5 29,5 75 4 56 11 33 63 httpadditional technical data at: www.theben.de/product/ Article number 195

Presence detector KX SYSTEMS ECO-IR 180EIB-AC Description Wall mounted passive infrared presence detector (PIR) For controlling lighting, ventilation etc., particularly in of ces and hallways Detection area 180 Genuine daylight measurement Automatic control of lighting and HVAC Presence output for HVAC control with switch-off delay ighting control with light threshold value and self-learning switch-off delay The lighting switches on with darkness and presence and off with suf cient light or absence The self-learning switch-off delay adjusts to occupants' behaviour Master or slave operating mode is selected via con guration Test operation mode checks the detection range and con guration The parameters are set by ETS or potentiometer The presence detector has "Genuine daylight measurement" and is only suitable for switching uorescent lamps (F/P) Choice of fully or semi automatic operation The presence detector detects moving bodies in a radius of approx. 8 m. Seated persons can be reliably detected in an area of 8 m x 4 m. The recommended installation height is 2.2 m BCU bus coupling unit KX necessary for operation Product selection Colour Type Article number Pure white (similar to RA 9010) ECO-IR 180EIB-AC 2029250 Black (similar to RA 9005) ECO-IR 180EIB-AC BK 2029809 Silver (similar to RA 9006) ECO-IR 180EIB-AC SR 2029810 additional colours available upon request Required accessories BCU bus coupling unit KX 9070524 Technical data ECO-IR 180EIB-AC 11 Operating voltage KX Bus voltage Recommended installation height 1.6 2.2 m Brightness measuring range 100 1600 lx ight switch-off delay 30 s 20 min Presence switch-off delay 30 s 60 min Ambient temperature +0 C +45 C Protection rating IP 40 Detection area (semicircle) Installation height (A) Sitting (B) Walking (C) A 2.2 2.2 m 32 m² 8 m x 4 m 100 m² Ø 16 m B C http Additional technical data at: 196 www.theben.de/product/ Article number

SYSTEMS Presence detector KX Accessories BUS coupling unit KX (required) Art.o.: 9070524 Details Page 232 QuickSafe Art.o.: 9070531 Details Page 233 Surface frame ECO-IR 180 Art.o.: 9070511 Details Page 231 Scale drawings 85 48 70 60 85 46,3 21,3 4 56 11 35 45 80 70 11 httpadditional technical data at: www.theben.de/product/ Article number 197

Presence detector KX SYSTEMS Presence detectors ECO-IR 360EIB-AC, ECO-IR DUA-EIB Description Common functions Passive infrared presence detector (PIR) For controlling lighting, ventilation etc., particularly in of ces and hallways Square detection area Genuine daylight measurement The square detection area allows accurate and simple planning The lighting switches on with darkness and presence and off with suf cient light or absence The self-learning switch-off delay adjusts to occupants' behaviour Master or slave operating mode is selected via con guration. Test operation mode checks the detection range and con guration The parameters are set by ETS or potentiometer. The presence detector has "Genuine daylight measurement" and is only suitable for switching uorescent lamps (F/P). Choice of fully or semi automatic operation BCU bus coupling unit KX necessary for operation ECO-IR 360EIB-AC Automatic control of lighting and HVAC Presence output for HVAC control with switch-off delay ighting control with light threshold value and self-learning switch-off delay ECO-IR DUA-EIB Automatic control of two lighting zones ighting control with two light threshold values and self-learning switch-off delay Two brightness measurements Product selection Colour Type Article number Pure white (similar to RA 9010) ECO-IR 360EIB-AC 2029201 Black (similar to RA 9005) ECO-IR 360EIB-AC BK 2029803 Silver (similar to RA 9006) ECO-IR 360EIB-AC SR 2029804 Pure white (similar to RA 9010) ECO-IR DUA-EIB 2029200 Black (similar to RA 9005) ECO-IR DUA-EIB BK 2029800 11 Silver (similar to RA 9006) ECO-IR DUA-EIB SR 2029801 additional colours available upon request Required accessories BCU bus coupling unit KX 9070524 Technical data ECO-IR 360EIB-AC ECO-IR DUA-EIB Operating voltage KX Bus voltage Recommended installation height 2 3.5 m Brightness measuring range 100 1600 lx ight switch-off delay 30 s 20 min Presence switch-off delay 30 s 60 min Ambient temperature +0 C +45 C Protection rating IP 40 http Additional technical data at: 198 www.theben.de/product/ Article number

SYSTEMS Presence detector KX Detection area (square) Installation height (A) Sitting (B) Walking (C) 2 m 20 m² 4.5 m x 4.5 m 36 m² 6.0 m x 6.0 m ± 0.5 m A 0.8 B C ux 2.5 m 36 m² 6.0 m x 6.0 m 64 m² 8.0 m x 8.0 m ± 0.5 m 3 m 49 m² 7.0 m x 7.0 m 81 m² 9.0 m x 9.0 m ± 0.5 m 3.5 m 64 m² 8.0 m x 8.0 m 100 m² 10.0 m x 10.0 m ± 1 m 4 m 121 m² 11.0 m x 11.0 m ± 1 m Accessories BUS coupling unit KX (required) Art.o.: 9070524 Details Page 232 QuickFix round cover Details Page 233 QuickFix square cover Art.o.: 9070516 Details Page 233 Additional accessories Pg. 232 QuickFix concrete round cover Details Page 232 QuickFix concrete square cover Details Page 232 QuickFix concrete ushmounted box Details Page 233 QuickFix concrete ushmounted housing Details Page 233 QuickSafe Details Page231 Surface frame ECO-IR 360 Details Page 232 Scale drawings 87 4 48 70 60 11 66,5 46,3 21,3 4 56 11 35,5 37,5 95 22 84,5 httpadditional technical data at: www.theben.de/product/ Article number 199

Weather station, brightness sensors KX SYSTEMS Weather stations KX Weather station KX Weather station basic KX Description Weather station KX Combination sensor for measuring wind, rain, brightness and temperature Rain sensor with heater (with connection at 230 V AC) Brightness range from 1-100,000 lux Temperature range -20 C to + 55 C Measurement and evaluation directly on device Sun protection for up to three facades possible (in combination with UA 133) Display of weather data, e.g. with VARIA multi-function display Weather station basic KX ike weather station KX, however: Combination sensor for measuring wind, brightness and temperature Without rain sensor 230 V AC connection not required Product selection Technical data Type Article number KX weather station 1329201 Weather station KX basic 1329205 KX weather station Weather station KX basic Operating voltage 230 V AC Operating voltage KX Bus voltage, (< 10 ma) Brightness measuring range 1 100000 lx Measuring range temperature 20 C +55 C Ambient temperature 20 C +55 C Protection class II in accordance with E 60 730-1 Protection rating IP 44 11 Accessories Mast mounting weather station Details Page 239 Scale drawings Weather station KX Weather station basic KX 280 280 66 66 135 135 160 80 http Additional technical data at: 200 www.theben.de/product/ Article number

SYSTEMS Weather station, brightness sensors KX UA 130 KX Description 3 channel brightness sensor For brightness-dependent controlling Threshold values, dimming levels and switch delay adjustable 3 threshold switches integrated Threshold can be set between 1 and 20,000 lux Behaviour adjustable if thresholds are exceeded or not met Up to 4 different brightness levels can be monitored Choice of 1-100 lux or 100-20,000 lux measuring ranges 3 con gurable thresholds Each section can be allocated one light setting consisting of 3 switching objects and 1 dimming object Product selection Type Article number UA 130 KX A 1309200 Technical data UA 130 KX A Operating voltage KX Brightness measuring range Switch-on delay Bus voltage, (< 10 ma) 1 20000 lx 8 s 240 min Width 2 modules Ambient temperature 5 C +45 C Protection rating IP 20 Accessories Flush-mounted light sensor UA KX Art.o.: 9070247 Details Page 236 11 httpadditional technical data at: www.theben.de/product/ Article number 201

Weather station, brightness sensors KX SYSTEMS UA 131 S KX Description Brightness and temperature sensor For brightness and temperature dependent controlling in outdoor areas 5 freely con gurable channels: 1 sun protection channel and 4 universal channels Sun protection channel with automised sun protection speci cally for blind, awning and shutter applications Universal channels allow linking of brightness and temperature Brightness range from 1-100,000 lux Temperature range -20 C to + 55 C earning object for brightness threshold Product selection Type Article number UA 131 S KX 1319201 Technical data UA 131 S KX Operating voltage KX Bus voltage, (< 5 ma) Brightness measuring range 1 100000 lx Measuring range temperature 25 C +55 C Ambient temperature 25 C +55 C Protection rating IP 54 Scale drawings 11 72 54 16 93 80 32 57 50,5 81,5 http Additional technical data at: 202 www.theben.de/product/ Article number

SYSTEMS Weather station, brightness sensors KX UA 133 KX Description Brightness sensor For brightness dependent controlling in outdoor areas Brightness range from 1-100,000 lux Ideally combinable with the Theben weather station for individual control of up to 3 facades Product selection Type Article number UA 133 KX 1339200 Technical data UA 133 KX Operating voltage KX Brightness measuring range Bus voltage, (< 5 ma) 1 100000 lx Ambient temperature 25 C +55 C Protection rating IP 54 Scale drawings 72 54 93 80 11 16 32 57 50,5 81,5 httpadditional technical data at: www.theben.de/product/ Article number 203

Digital time switches KX SYSTEMS Digital time switches TR 648 S DCF KX TR 644 S DCF KX Description Common functions 365-day time switch With daily, weekly, yearly, random, pulse and priority programs Free weekdays and channel blocks 1.5 years power reserve via replaceable environmentally-friendly lithium battery Movable public holidays can be automatically adjusted annually Automatic summer/winter time change Switching times are permanently stored in EEPROM Programming via key entry on device or OBISK 2.1 programming set Interface for OBEISK memory card (PC programming) Time and date synchronisation from other bus participants Time-dependent speci cation of different temperature levels for individual room control Time-dependent compulsory control (mainly O or OFF) by consumers via priority telegrams Random switching for presence simulation TR 648 S DCF KX 16 channel time switch with annual program Optional DCF77 radio Channels 1 to 4 can be programmed as astronomical switching channels (astronomical programs can only be programmed using OBEISH software) TR 644 S DCF KX 4 channel time switch with yearly program Optional DCF77 radio TR 644 S KX 4 channel time switch with yearly program Without DCF77 radio Product selection Type Article number 11 TR 648 S DCF KX 6489201 TR 644 S DCF KX 6449204 TR 644 S KX 6449203 http Additional technical data at: 204 www.theben.de/product/ Article number

SYSTEMS Digital time switches KX Technical data TR 648 S DCF KX TR 644 S DCF KX TR 644 S KX Operating voltage KX Bus voltage, (< 10 ma) Operating voltage 230 V AC (only with DFC77 antenna connection) Width 6 modules umber of channels 16 4 umber of astronomical channels 4 umber of memory cells 500 324 Time accuracy ± 1 s/day(quartz) or DCF77 ± 1 s/day(quartz) Shortest switching time 1 s Display CD Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60,335 Accessories Antenna DCF77 KX Art.o.: 9070271 Details Page 228 OBEISK KX PC set Art.o.: 9070305 Details Page 229 Memory card OBEISK KX 64 K For TR 648 S DCF KX Art.o.: 9070320 Details Page 230 Memory card OBEISK KX 16 K For TR 644 S DCF KX Art.o.: 9070223 Details Page 229 Connection example TR 648 S DCF KX TR 644 S DCF KX 11 KX DCF RC DCF KX DCF RC DCF httpadditional technical data at: www.theben.de/product/ Article number 205

Digital time switches KX SYSTEMS TR 612 S KX Description 2 channel weekly timer With screen to display: Day of the week, time, switching status etc. With daily and weekly programs 36 switching times 99 day holiday program; programmed in advance 6 year power reserve Automatic summer/winter time change Automatic program review Switching times are permanently stored in EEPROM Permanent O/OFF switching Product selection Type Article number TR 612 S KX 6129201 Technical data TR 612 S KX Operating voltage KX Bus voltage, (< 3.5 ma) Width 2 modules umber of channels 2 umber of memory cells 36 Time accuracy ± 1 s/day(quartz) Shortest switching time 1 min Display CD Ambient temperature 5 C +45 C Protection rating IP 20 Protection class II in accordance with E 60 335 11 http Additional technical data at: 206 www.theben.de/product/ Article number

SYSTEMS System devices KX ZS 600 DCF KX Description Time transmitter for hour and date Can also be used with DCF77 antenna ED for status display DCF reception Integrated voltage supply for DCF77 antenna Preset time and date (CET or CEST) Automatic summer/winter time change Product selection Type Article number ZS 600 DCF KX 6009200 Technical data ZS 600 DCF KX Operating voltage KX Width Power reserve Time accuracy Bus voltage, (< 10 ma) 2 modules 10 years ± 1 s/day(quartz) or DCF77 Ambient temperature 10 C +50 C Protection class III in accordance with E 60 730-1 Protection rating IP 20 Accessories Antenna DCF77 KX Art.o.: 9070271 Details Page 228 11 httpadditional technical data at: www.theben.de/product/ Article number 207

System devices KX SYSTEMS Power supply 640 ma/320 ma/160 ma Power supply 640 ma Power supply 320 ma Power supply 160 ma Description Common functions KX-Supply voltage Produces and monitors the KX system voltage and 30 V DC auxiliary supply Reset key for 20 sec. bus reset Continuous short-circuit protection Power supply 640 ma 640 ma supply voltage Power supply 320 ma 320 ma supply voltage Power supply 160 ma 160 ma supply voltage Product selection Type Article number Power supply 640 ma 9070364 Power supply 320 ma 9070699* Power supply 160 ma 9070701* *Available May 2010 Technical data Power supply 640 ma Power supply 320 ma Power supply 160 ma 11 Operating voltage 230 V AC, 50 60 Hz Width 6 modules 4 modules KX Output 1 line with integrated throttle valve KX nominal voltage 30 V DC, ± 2 V, SEV 30 V Output 1 (unthrottled) 30 V nominal voltage 30 V DC, ± 2 V, SEV ominal current 640 ma 320 ma 160 ma Ambient temperature 5 C +45 C Protection class II in accordance with E 60 730-1 Protection rating IP 20 http Additional technical data at: 208 www.theben.de/product/ Article number

SYSTEMS System devices KX Interface USB KX, ine coupler KX Interface USB KX ine coupler KX Description Interface USB KX USB interface For communication between PC and the KX equipment to be programmed USB ED and KX ED to display data transmission Usable from ETS3 V1.0 ine coupler KX ine coupler For connecting KX lines or areas Galvanic separation of the lines/areas Bus terminals for main line and subordinate line Telegrams can be ltered (to reduce telegram traf c) Can also be used as line ampli er (repeater) Product selection Type Article number Interface USB KX 9070397 ine coupler KX 9070398 Technical data Interface USB KX ine coupler KX Operating voltage KX Bus voltage, (< 10 ma) Width 2 modules Ambient temperature 5 C +45 C Protection class II in accordance with E 60 730-1 III in accordance with E 60,730-1 Protection rating IP 20 11 httpadditional technical data at: www.theben.de/product/ Article number 209

Display units KX SYSTEMS KX indoor clock OSIRIA 220 AR KX OSIRIA 242 SR KX OSIRIA 280 B KX Description OSIRIA 220 AR KX KX indoor clock, round, single-sided Black bar hour and minute hands, red second hand Black DI bar hour and minute hands, red second hand OSIRIA 230 AR KX/OSIRIA 230 SR KX OSIRIA 240 AR KX/OSIRIA 240 SR KX OSIRIA 241 AR KX/OSIRIA 241 BR KX Description like OSIRIA 220 AR KX OSIRIA 242 AR KX/OSIRIA 242 SR KX KX indoor clock, round, double-sided With wall or ceiling holder (150 mm) Black bar hour and minute hands, red second hand OSIRIA 251 BQ KX KX indoor clock, square, single-sided Wall clocks protected against thrown balls e.g. for sports halls, schools, etc. Black bar hour and minute hands, red second hand 3-point fastening resistant to being pried out OSIRIA 232 BQ KX KX indoor clock, square, single-sided, for ush-mounted installation (for OP rooms) Black bar hour and minute hands, red second hand Resistant to acids, cleaning agents and disinfectants; in the installed state protected against dust and water in acc. with protection rating IP 54 (DI 40050) OSIRIA 280 B KX KX indoor clock, digital, square, singlesided Analogue clock with 1-line, 9-segment CD digital display for date Free-wheel black bar hand, red second hand Additional clocks upon request. 11 Additional information about these products can be found at www.peweta.de. http Additional technical data at: 210 www.theben.de/product/ Article number

SYSTEMS Display units KX Product selection Dimensions Clock face Ø 250 mm Ø 300 mm Ø 400 mm 250 mm x 250 mm Ø 280 mm Housing material Clock face Type Article number Impact-resistant plastic housing, matt border or chrome-plated metal housing, at shock-resistant Plexiglas Chromium-plated metal housing, domed, shock-resistant Plexiglas White painted metallic housing (RA 9016), shock-resistant Plexiglass White painted metallic housing (RA 9016), laminated safety glass Stainless steel housing frame ush with tiles or wall V4A for wall installation ( ush-mounted), 3 mm at mineral lens Flat metal housing, o front lens White metallic dial, black Arabic numerals White metallic dial, black ne-line numerals White metallic dial, black Arabic numerals White metallic dial, black ne-line numerals White metallic dial, black Arabic numerals White metallic dial, black bar numerals White dials, black Arabic numerals White metallic dial, black ne-line numerals White metallic dial, black bar numerals Faces with black ne line numerals OSIRIA 220 AR KX 5009200 OSIRIA 230 AR KX 5009210 OSIRIA 230 SR KX 5009211 OSIRIA 240 AR KX 5009230 OSIRIA 240 SR KX 5009231 OSIRIA 241 AR KX 5009240 OSIRIA 241 BR KX 5009241 OSIRIA 242 AR KX 5009250 OSIRIA 242 SR KX 5009251 OSIRIA 251 BQ KX 5009252 OSIRIA 232 BQ KX 5009223 OSIRIA 280 B KX 5009280 Technical data OSIRIA Operating voltage KX Bus voltage, (< 5 ma) Power reserve 10 days Ambient temperature 5 C +45 C 11 httpadditional technical data at: www.theben.de/product/ Article number 211

SYSTEMS http Additional technical data at: www.theben.de/product/ Article number 212

Section overview SYSTEMS iving comfort control Description Type Page Switching UXOR 400 214 UXOR switching UXOR 404 214 UXOR 402 214 Dimming UXOR dimming UXOR 405 216 DMB 2 S 216 Roller shutter control UXOR shutter control UXOR 408 217 UXOR 409 217 Weather sensors UXOR 411 218 UXOR weather sensors UXOR 412 218 UXOR 413 218 Clock module UXOR clock module UXOR 414 220 UXOR Sets UXOR Sets UXOR Set 3 221 UXOR Set 4 221 12 httpadditional technical data at: www.theben.de/product/ Article number 213

iving comfort control Switching SYSTEMS UXOR switching UXOR 400 UXOR 404 UXOR 402 Description Common functions Modular expandable system with central functions For switching electrical consumers Manual switch on device EDs to display 2 time functions (staircase light function with switch-off warning, lag function) Upgradeable for up to 16 UXOR modules Central O/OFF, panic function and presence simulation UXOR modules are connected via 2-wire bus cable (COM bus) Max. input cable length up to 100 m Input separate for connecting FI (RCD) Universal voltage input: 8 48 V AC/DC (e. g. for intercoms) Control for con guring central functions UXOR 400 4-channel basic device for lighting control Selector switch for con guring central functions Inputs U1 and I4 oating UXOR 404 4-channel extension device for lighting control Input I4 oating UXOR 402 2-channel extension device for lighting control Input I4 oating Product selection Type Article number UXOR 400 4000000 UXOR 404 4040000 12 UXOR 402 4020000 http Additional technical data at: 214 www.theben.de/product/ Article number

SYSTEMS iving comfort control Switching Technical data UXOR 400 UXOR 404 UXOR 402 Operating voltage 230 V AC Frequency 50 Hz Width 4 modules 2 modules Power consumption 4 VA Installation type DI-rail Type of contact O contact Connecting cable 230 V phase-independent supply cable, cable length max. 100 m Connection for COM Any cross-section/max. length 100 m Switching capacity 16 A (at 250 V AC, cos = 1), 6 A (at 250 V AC, cos = 0.6) Ambient temperature 10 C +50 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 Accessories Diode module UXOR Art.o.: 9070367 Details Page 239 Front panel kit Art.o.: 9070001 Details Page 228 Connection example * * * * * * = UXOR 412 + U I4 I4 () () C4 I1 I2 I3 COM + S I1 I2 S1 S2 P S UXOR 400 COM UXOR 405 + C1 C2 C3 C4 D1 D2 I1 I2 I3 I4 G1 COM UXOR 408 + C1 C2 C2 C3 C3 COM UXOR 414 + C1 C2 COM + C3 UXOR 411 + 12 M M M httpadditional technical data at: www.theben.de/product/ Article number 215

iving comfort control Dimming SYSTEMS UXOR dimming UXOR 405 DMB 2 S Description UXOR 405 2 channel universal dimmer For dimming electric consumers such as incandescent lamps, high-voltage halogen lamps, low-voltage halogen lamps with conventional or electronic transformers 300 W/VA (for 2 channels) or 500 W/VA (for 1 channel) For conventional and electronic transformers Can also be used without basic module Manual switch on device EDs to display Upgradeable for up to 16 UXOR modules UXOR modules are connected via 2-wire bus cable (COM bus) One additional input per channel for motion detector With overcurrent display Input for up to 3 light settings 4 program options for dimming response Central functions: Presence simulation, central OFF, panic function, central O DMB 2 S 2-way dimming output extension 'Dimmbooster' for UXOR 405 To double the output of basic and extension modules. e. g. to: 2 x 600 W/VA (1 channel) or 1 x 1,000 W/VA (2 channels) ED switching status display for each channel Product selection Technical data 12 Type Article number UXOR 405 4050000 DMB 2 S 4910272 UXOR 405 DMB 2 S Operating voltage 230 V AC Frequency 50 Hz Width 4 modules Power consumption 3 VA Installation type DI-rail umber of channels 2 Outputs semi-conductor Triacs Connecting cable 230 V phase-independent supply cable, cable length max. 100 m Connection for COM Any cross-section/max. length 100 m Protection rating IP 20 Protection class II in accordance with E 60 730-1 http Additional technical data at: 216 www.theben.de/product/ Article number

SYSTEMS iving comfort control Shutter control UXOR shutter control UXOR 408 UXOR 409 Description Common functions For controlling shutters, awnings or blinds Separate control of 4 shutters with UP/DOW/STOP Manual switch on device EDs to display Controllable via standard shutter sensor Upgradeable for up to 16 UXOR modules UXOR modules are connected via 2-wire bus cable (COM bus) Setting option for panic function (via UXOR 400) Storable intermediate position and turn for shading and ventilation UXOR 408 4-channel roller shutter basic module Central UP/DOW, panic 1 group With three group functions (individual, group and central control) Expandable via channel extension modules, time and sensor module and weather station UXOR 409 4 channel shutter extension module Product selection Technical data Type Article number UXOR 408 4080000 UXOR 409 4090000 UXOR 408 UXOR 409 Operating voltage 230 V AC Frequency 50 Hz Width 4 modules Power consumption 4 VA Installation type DI-rail umber of channels 4 Type of contact O contact Connecting cable 230 V phase-independent supply cable, cable length max. 100 m Connection for COM Any cross-section/max. length 100 m Switching capacity 6 A (at 250 V AC, cos = 1) Function channels for shutter, blind and awning control Ambient temperature 10 C +50 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 12 httpadditional technical data at: www.theben.de/product/ Article number 217

iving comfort control Weather sensors SYSTEMS UXOR sensor technology UXOR 411 UXOR 412 UXOR 413 Description UXOR 411 Sensor module For controlling awnings, shutters and blinds in combination with UXOR 412 and/or 413 and integrated light sensors Setting threshold values on device EDs to display Max. input cable length of sensor line is 100 m UXOR modules are connected via 2-wire bus cable (COM bus) UXOR 412 Weather sensor For controlling awnings, shutters and blinds depending on rain, wind velocity, temperature and brightness in combination with sensor module UXOR 411 Optional connection of up to two additional light sensors for additional facades Supply voltage via COM-Bus UXOR 413 Wind sensor For controlling awnings, shutters and blinds depending on wind velocity in combination with sensor module UXOR 411 Extra power unit required Optional connection of up to three additional facades with automatic sun protection function Product selection Type Article number UXOR 411 4110000 UXOR 412 4120000 UXOR 413 4130000 12 http Additional technical data at: 218 www.theben.de/product/ Article number

SYSTEMS iving comfort control Weather sensors Technical data UXOR 411 UXOR 412 UXOR 413 Operating voltage 230 V AC COM-Bus 24 V DC Frequency 50 Hz Width 4 modules Power consumption 5.5 VA Installation type DI-rail Wall or mast installation Connection for COM Any cross-section / max. length 100 m Setting range twilight value 1 100 lx Setting range sun protection 1000 100000 lx Measuring range wind velocity 2 20 m/s Measuring range temperature +0 C +60 C Ambient temperature 10 C +50 C 20 C +55 C Protection rating IP 20 IP 44 IP 43 Protection class II in accordance with E 60 730-1 III in accordance with E 60,730-1 Accessories Surface-mounted light sensor For UXOR 411 Art.o.: 9070008 Details Page 235 Mast mounting weather station For UXOR 412, UXOR 413 Art.o.: 9070380 Details Page 239 Power unit 24 V DC For UXOR 413 Art.o.: 9079330 Details Page 239 Scale drawings UXOR 412 UXOR 413 280 280 12 66 66 135 135 160 80 httpadditional technical data at: www.theben.de/product/ Article number 219

iving comfort control Clock module SYSTEMS UXOR 414 Description 8 channel time switch For control of any outputs in UXOR system, e. g. shutters, blinds and awnings or for lighting control Manual switch on device Daily and weekly programs Astronomical program (dependent on sunrise and sunset) Freely programmable switching times as well as pre-programmed astronomical switching times Easy location input via city list Individual link of time switch channels with the outputs via selector switch Positioning of drives (UXOR 408/ UXOR 409) as well as transmission of dimming values (UXOR 405) as percentage values Blocking times for suppression of brightness or twilight signals from sensor module (UXOR 411) Astronomical blocking times for time shifts for moving shutters/awnings up and down Automatic changeover summer/winter time UXOR modules are connected via 2-wire bus cable (COM bus) Product selection Type Article number UXOR 414 4140000 Technical data Operating voltage 230 V AC Frequency 50 Hz Width 2.5 modules Power consumption 4 VA Installation type DI-rail umber of channels 8 UXOR 414 Connection for COM Any cross-section/ max. length 100 m umber of memory cells 128 Ambient temperature 10 C +50 C Protection rating IP 20 Protection class II in accordance with E 60 730-1 12 http Additional technical data at: 220 www.theben.de/product/ Article number

SYSTEMS iving comfort control Clock module UXOR Sets UXOR Set 3 UXOR Set 4 Description UXOR Set 3 Set for the comfortable single family house with 10 separate lighting units and 4 time functions Additional dimming channels e. g. for living room and bedrooms This set also offers the advantage of central functions Suitable for 10 separate lighting units, 4 x time/switch and 4 x switch, 2 x dimming Consisting of: Box, 1 UXOR 400, 1 UXOR 404, 1 UXOR 405 UXOR Set 4 Set for shutter and blind controlling 8 drives can be manually or automatically controlled according to time program or sunrise or sunset Blocking times for time shifts for moving shutters/awnings up and down in the early morning Additional comfortable central functions Suitable for shutter and blind 8 drives, 8 drives and 8 time channels with weekly program with astronomical function Consisting of: Box, 1 UXOR 408, 1 UXOR 409, 1 UXOR 414 Product selection Type Article number UXOR Set 3 4990003 UXOR Set 4 4990004 12 httpadditional technical data at: www.theben.de/product/ Article number 221

SYSTEMS http Additional technical data at: www.theben.de/product/ Article number 222

Section overview SYSTEMS Controller umber of inputs umber of outputs Operating voltage Type Page Controller 6 4 8 6 15 9 100 240 V AC PHARAO-II 10 (AC) 224 24 V DC PHARAO-II 11 (DC) 224 100 240 V AC PHARAO-II 14 (AC) 224 24 V DC PHARAO-II 15 (DC) 224 100 240 V AC PHARAO-II 24 (AC) 224 24 V DC PHARAO-II 25 (DC) 224 4 220 240 V AC PHARAO-II upgrade 4AR (AC) 224 24 V DC UA 131 DDC 226 1 1 100 240 V AC SUD 228 II 226 13 httpadditional technical data at: www.theben.de/product/ Article number 223

Controller Controller SYSTEMS PHARAO controller devices PHARAO-II 10 (AC) PHARAO-II 24 (AC) PHARAO-II upgrade 4AR (AC) Description Common functions Small control unit for house automation and industry Programming directly on device via eight buttons without interface cable Backlit CD display with operator guidance in clear text Input and output switching status display ifespan of relay contacts is 100,000 switching cycles at nominal current Assignment of programmed functions on front keys Internal EEPROM memory for max. 200 function blocks (5,000 bytes) Optional plug-in EEPROM for program transfer or dual programming of internal and plugged-in EEPROM 3-level password protection Realtime year clock with 1,000 switching times Graphical programming software for Windows 95/98/T/2000/ME/XP with detailed online Help documentation Remote control/remote monitoring possible via modem/gsm modem Transmission of SMS, email or fax PHARAO-II 10 (AC) Operating voltage 100 240 V AC 6 digital inputs, e. g. for keys, brightness and temperature switches 4 relay outputs PHARAO-II 11 (DC) Operating voltage 24 V DC 6 digital/analogue inputs 4 relay outputs PHARAO-II 14 (AC) Operating voltage 100 240 V AC 8 digital inputs, e. g. for keys, brightness and temperature switches 6 relay outputs PHARAO-II 15 (DC) Operating voltage 24 V DC 8 digital/analogue inputs 6 relay outputs PHARAO-II 24 (AC) Operating voltage 100 240 V AC 15 digital inputs, e. g. for keys, brightness and temperature switches 9 relay outputs PHARAO-II 25 (DC) Operating voltage 24 V DC 15 inputs, including 8 analogue/digital options 9 relay outputs PHARAO-II upgrade 4AR (AC) 4 channel relay output upgrade Product selection 13 umber of inputs umber of outputs Operating voltage Type Article number 6 4 8 6 100 240 V AC PHARAO-II 10 (AC) 5750210 24 V DC PHARAO-II 11 (DC) 5759211 100 240 V AC PHARAO-II 14 (AC) 5750014 24 V DC PHARAO-II 15 (DC) 5759015 100 240 V AC PHARAO-II 24 (AC) 5750024 15 9 24 V DC PHARAO-II 25 (DC) 5759025 220 240 V AC PHARAO-II upgrade 4AR (AC) 5759102 http Additional technical data at: 224 www.theben.de/product/ Article number

SYSTEMS Controller Controller Technical data PHARAO-II 10 (AC) PHARAO-II 11 (DC) PHARAO-II 14 (AC) PHARAO-II 15 (DC) PHARAO-II 24 (AC) PHARAO-II 25 (DC) PHARAO-II upgrade 4AR (AC) Operating voltage 100 240 V AC 24 V DC 100 240 V AC 24 V DC 100 240 V AC 24 V DC 220 240 V AC Frequency 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz Power consumption 5 VA 4 VA 5.5 VA 7.5 VA 7 VA 9 VA Installation type DI-rail Type of contact O contact Display CD Width 4 modules 7 modules Power reserve 20 days Time accuracy ± 5 s/day(quartz) Max. switching capacity 8 A (at 250 V AC, cos = 1), 373 VA (at 250 V AC, inductive load) 4 x 8 A (250 V AC, cos =1), inductive load max. 373 VA, 5 x 2 A (250 V AC, cos =1), inductive load max. 93 VA 2 A (at 250 V AC, cos = 1) Input frequency 5 Hz 20 Hz Ambient temperature 25 C +55 C Type of protection IP 20 Protection class II in accordance with E 60 730-1 Accessories Power unit 24 V DC Art.o.: 9079330 Details Page 239 Memory module PHARAO-II Art.o.: 9070328 Details Page 239 Programming software PHARAO Art.o.: 9070251 Details Page 239 Additional accessories GSM cable PHARAO-II Details Page 239 Programming cable PHARAO Details Page 239 Connection example PHARAO-II 10 (AC) 1 2 3 4 5 6 13 OUT 1 OUT 2 OUT 3 OUT 4 1 2 httpadditional technical data at: www.theben.de/product/ Article number 225

Controller Controller SYSTEMS PHARAO Accessories UA 131 DDC SUD 228 II Description UA 131 DDC Combination sensor with analogue output signal Can be used for brightness and temperature measurement Each of the two measurement outputs represents a 0 10 V analogue output signal The sensor can be connected directly to the analogue inputs of the PHARAO devices (24 V DC) Controls and regulators can be programmed with the signal converter, range compare and Schmitt trigger function modules External 24 V DC power unit required SUD 228 II Charging switch for electric storage heaters Adjustable charging time and backward control If the ripple control receiver or the tariff time switch have been released for nighttime off-peak tariff, the device starts the charging program for storage heating Charging time can be set from 0 9 hours Onscreen display of charging time which is repeated every 24 hours Backward control stops charging process at the end of off-peak period Manual switch can be connected for daytime charging Product selection Type Article number UA 131 DDC 1319700 13 SUD 228 II 2280577 http Additional technical data at: 226 www.theben.de/product/ Article number

SYSTEMS Controller Controller Technical data UA 131 DDC SUD 228 II Operating voltage 24 V DC 100 240 V AC Frequency 50 60 Hz Power consumption 3 VA Installation type DI-rail Type of contact O contact Display CD Max. switching capacity 8 A (at 250 V AC, cos = 1) Ambient temperature 30 C +70 C +0 C +55 C Type of protection IP 54 IP 20 Protection class II in accordance with E 60 730-1 Accessories Connection example Power unit 24 V DC Art.o.: 9079330 Details Page 239 SUD 228 II 1 2 3 4 OUT 1 Scale drawings UA 131 DDC 72 54 16 93 80 32 57 50,5 81,5 13 httpadditional technical data at: www.theben.de/product/ Article number 227

ACCESSORIES Antenna DCF77 Antenna DCF77 KX Description Suitable for Type Article number Time synchronisation with DCF antennas. To ensure good reception, do not install the antenna in cellars or on distribution boxes. Connection is made via separate 2-wire, unscreened high-voltage power cable (max. 100 m), up to 10 Theben devices can be connected. Polarity, short-circuit and interruption of the antenna circuit are each visually displayed. TR 641 S DCF TR 642 S DCF TR 644 S DCF SEEKTA 173 DCF Antenna DCF77 9070243 Time synchronisation with DCF antennas for KX time switches Installation see DCF77 antennas TR 648 S DCF KX TR 644 S DCF KX ZS 600 DCF KX Antenna DCF77 KX 9070271 Antenna top2 RC-DCF Antenna top2 RC-GPS Front panel kit Time synchronisation with DCF antennas for top2 devices Installation see DCF77 antennas Worldwide time synchronisation and positioning via receiving GPS satellite signal. The antenna is connected by a 2 wire cable (max. 100 m) to Theben top2 RC devices (up to 10 devices can be connected). A top2 GPS power unit (item number 9070892) is also required when connecting to TR 611 op2 RC, UA 121 top2 RC, UA 122 top2 RC or SEEKTA 171 top2 RC devices. o additional power un it is required when connecting to TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC devices or several devices to one antenna. Positioning is possible with TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC and SEEKTA 171 top2 RC devices. TR 611 top2 RC UA 121 top2 RC UA 122 top2 RC SEEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC TR 611 top2 RC UA 121 top2 RC UA 122 top2 RC SEEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC Antenna top2 RC-DCF 9070410 Antenna top2 RC-GPS (Available July 2010) 9070610 Front panel installation set is suitable for Theben DI rail installation devices of 17.5 to 107.5 mm width. Walls from 1 to 5 mm thick All DI rail installation devices Front panel kit 9070001 Terminal cover 52.5 mm Terminal box cover plate for assembly, sealable TM 178 h SY 168 h SU 188 h SU 188 g MEM 198 h SU 188 hw TM 171 h SY 161 h SU 181 h Terminal cover 52.5 mm 9070061 http Additional technical data at: 228 www.theben.de/product/ Article number

ACCESSORIES Power unit DCF77 Description Suitable for Type Article number Power unit for DCF antenna Width 2 modules (35 mm) TR 641 S DCF TR 642 S DCF TR 644 S DCF Power unit DCF77 9070182 Power unit top2 GPS OBEISK PC set OBEISK KX PC set ecessary for antennas top2 RC-GPS in combination with TR 611 top2 RC, UA 121 top2 RC, UA 122 top2 RC or SEE- KTA 171 top2 RC (the power unit is not necessary when 2 or more devices are connected to the antenna) Width 2 modules (35 mm) OBEISK memory card, RS 232 plug-in adapter, software TR 611 top2 RC UA 121 top2 RC UA 122 top2 RC SEEKTA 171 top2 RC TR 641 S TR 641 S DCF TR 642 S TR 642 S DCF TR 644 S TR 644 S DCF SEEKTA 173 DCF Power unit top2 GPS (Available July 2010) 9070892 OBEISK PC set 9070230 OBEISK KX memory card 16 K, RS 232 plug-in adapter, software TR 648 S DCF KX TR 644 S DCF KX OBEISK KX PC set 9070305 OBEISK top2 PC set OBEISK top2 memory card, USB plug-in adapter, software Updates of existing OBEISK top2 software are available as free downloads at www.theben.de. TR top2 UA top2 SEEKTA top2 OBEISK top2 PC set 9070409 Quick fastening 72 x 72 Snap-on mounting for 35 mm DI rails All time switches for front panel/wall installation Quick fastening 72 x 72 9070071 Memory card OBEISK KX 16 K Individual memory card TR 644 S DCF KX Memory card OBEISK KX 16 K 9070223 14 httpadditional technical data at: www.theben.de/product/ Article number 229

ACCESSORIES Memory card OBEISK KX 64 K Description Suitable for Type Article number Individual memory card TR 648 S DCF KX Memory card OBEISK KX 64 K 9070320 Memory card OBEISK Individual memory card TR 641 S TR 641 S DCF TR 642 S TR 642 S DCF TR 644 S TR 644 S DCF SEEKTA 173 DCF Memory card OBEISK 9070165 Memory card OBEISK top2 Individual memory card TR top2 UA top2 SEEKTA top2 Memory card OBEISK top2 9070404 Wall mounting kit 17.5 mm Wall installation set for top mounting, sealable All DI rail installation devices with 1 module width Wall mounting kit 17.5 mm 9070065 Wall mounting kit 35 mm Wall installation set for top mounting, sealable All DI rail installation devices with 2 modules width Wall mounting kit 35 mm 9070064 Wall mounting kit 52.5 mm Wall installation set for top mounting, sealable All DI rail installation devices with 3 modules width Wall mounting kit 52.5 mm 9070050 Wall mounting kit 70 mm 14 Wall installation set for top mounting, sealable All DI rail installation devices with 4 modules width Wall mounting kit 70 mm 9070049 http Additional technical data at: 230 www.theben.de/product/ Article number

ACCESSORIES Wall mounting kit 105 mm Description Suitable for Type Article number Wall installation set for top mounting, sealable All DI rail installation devices with 6 modules width Wall mounting kit 105 mm 9070053 Cover 55 x 55 for BZ Cover for hour counters BZ 142-1 Cover 55 x 55 for BZ 9070041 Cover 72 x 72 for BZ Cover for hour counters BZ 142-1 Cover 72 x 72 for BZ 9070074 Front kit BZ 142-3 Terminal box cover plate for hour counters BZ 142-3 Front-kit BZ 142-3 9070075 Clamp BZ Clamping bracket for hour counters BZ 142-1 BZ 143-1 BZ 146 BZ 147 Clamp BZ 9070043 Plug-in socket BZ Plug-in base for hour counters BZ 142-3 Plug-in socket BZ 9070042 Surface frame ECO-IR 180 Presence detector surface frame ECO-IR 180A ECO-IR 180-24V ECO-IR 180EIB-AC Surface frame ECO-IR 180 9070511 14 httpadditional technical data at: www.theben.de/product/ Article number 231

ACCESSORIES Surface frame ECO-IR 360 Description Suitable for Type Article number Presence detector surface frame All ECO-IR 360 ECO-IR DUA-EIB Surface frame ECO-IR 360 9070512 Surface frame Presenceight Presence detector surface frame Presenceight 180 Presenceight 360 Surface frame Presenceight 9070513 Surface frame compact Presence detector surface frame All compact of ce All compact passage/passimo Surface frame compact 9070514 Bus coupling unit KX Required for various presence detectors For ush-mounted installation ECO-IR 180EIB-AC ECO-IR 360EIB-AC ECO-IR DUA-EIB Bus coupling unit KX 9070524 RC lter Suppression lter for presence and motion detectors All presence and motion detectors RC lter 9070523 QuickFix concrete square cover QuickFix concrete, ush-mounted socket for concrete Flush ceiling installation The presence detector is inserted into the false ceiling using a ush-mounted socket, just leaving pyramid lense visible ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix concrete square cover 9070518 QuickFix concrete round cover QuickFix concrete, ush-mounted socket for concrete Flush ceiling installation The presence detector is inserted into the false ceiling using a ush-mounted socket, just leaving pyramid lense visible ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix concrete round cover 9070519 14 http Additional technical data at: 232 www.theben.de/product/ Article number

ACCESSORIES QuickFix square cover QuickFix housing For false ceilings Flush ceiling installation Description Suitable for Type Article number The presence detector is inserted into the false ceiling, just leaving pyramid lense visible ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix square cover 9070516 QuickFix round cover QuickFix housing For false ceilings Flush ceiling installation The presence detector is inserted into the false ceiling, just leaving pyramid lense visible ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix round cover 9070517 QuickFix concrete ush-mounted box QuickFix ush-mounted socket concrete ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix concrete ush-mount box 9070521 QuickFix concrete ush-mounted housing QuickFix housing Incl. ush-mounted socket ECO-IR 360A ECO-IR 360C T ECO IR DUA C T ECO-IR 360-24V ECO-IR 360EIB-AC ECO-IR DUA-EIB QuickFix concrete ush-mount housing 9070522 QuickSafe QuickSafe safety cover Secure protection against damage Robust and solid design Particularly impact resistant and vandalproof 6 screws, 3 rawlplugs and 3 spacers All Theben HTS presence detectors QuickSafe 9070531 Junction casing, 115 x 115 x 100mm Agro/Kaiser ush-mounted junction box/connection box 9908.01 PlanoCentro 101-UWH/000-UWH Junction casing, 115 x 115 x 100 mm 9070689 clic Infrared remote control for ThebenHTS presence detectors Switching and dimming of lighting, scene control 2 channels for 2 lighting groups 2 programmable scenes 5 group addresses for de ning channels Coding switch and programming key for the easy allocation of lighting groups and channels All remote controlled ThebenHTS presence detectors, except Plano- Centro clic9070515 14 httpadditional technical data at: www.theben.de/product/ Article number 233

ACCESSORIES QuickSet plus SendoClic SendoPro 868-A UXA corner angle black Description Suitable for Type Article number Infrared remote control for the convenient startup of ThebenHTS presence detectors Rapid adjustment to changed operating conditions without uninstalling detectors Transmission of individual settings or complete value packages to the detector Call up of pre-de ned value packets for typical rooms Storing and calling-up 8 user-de ned value packets Onscreen text guidance Infrared remote control for PlanoCentro Switching and dimming of lighting, scene control 2 channels for 2 lighting groups 2 programmable scenes 5 group addresses for de ning channels Coding switch and programming key for the easy allocation of lighting groups and channels Infrared remote control for the convenient startup of HTS presence detectors Compatible with PlanoCentro, compact, Presenceight and ECO-IR C T The SendoPro 868A management remote control for the electrician enables ef cient start-up and exible adaptation to new applications. Rapid adjustment of parameters to changed operating conditions without uninstalling detectors Transmission of individual settings or complete con guration sets to the detector Select con gurations from PlanoCentro Calling up of pre-de ned value packets for typical rooms Saving and calling up user-de ned parameter sets on internal memory or SD card Updates via SD card All remote controlled ThebenHTS presence detectors, except PlanoCentro QuickSet plus 9070532 PlanoCentro SendoClic 9070690 All remote controlled ThebenHTS presence detectors SendoPro 868-A 9070675 For corner installation of motion detectors Wall installation, external corner installation UXA 101-150 UXA 101-180 UXA corner angle black 9070625 UXA corner angle white For corner installation of motion detectors Wall installation, external corner installation UXA 101-150 UXA 101-180 UXA 101-360 UXA corner angle white 9070626 SPHIX corner angle 14 For corner installation of motion detectors Wall installation, external corner installation SPHIX 105-110 SPHIX 105-220 SPHIX 105-300 SPHIX 105-300 KX SPHIX corner angle 9070535 http Additional technical data at: 234 www.theben.de/product/ Article number

ACCESSORIES SPHIX RC 104 Description Suitable for Type Article number User remote control for SPHIX 104 O/OFF/Automatic Teach-in function for teaching in the current brightness value SPHIX 104-360 SPHIX 104-360/2 SPHIX 104-360 AP SPHIX 104-360/2 AP SPHIX RC 104 9070538 SPHIX RC 104 Pro SPHIX RC 105 Service remote control for SPHIX 104 O/OFF Teach-in function for teaching in the current brightness value Pre-de ned brightness values and switch-on times Impulse, reset and test function Block function SPHIX 104-360 SPHIX 104-360/2 SPHIX 104-360 AP SPHIX 104-360/2 AP SPHIX RC 104 Pro 9070536 User remote control for SPHIX 105 O/OFF (2 hr, 4 hr, continuous) Automatic Teach-in function for teaching in the current brightness value SPHIX 105-110 SPHIX 105-220 SPHIX 105-300 SPHIX 105-300 KX SPHIX RC 105 9070539 SPHIX RC 105 Pro Surface frame UXA 103-200 Service remote control for SPHIX 105 O/OFF Teach-in function for teaching in the current brightness value Pre-de ned brightness values and switch-on times Impulse, reset and test function Block function Creep under protection O/OFF SPHIX 105-110 SPHIX 105-220 SPHIX 105-300 SPHIX 105-300 KX SPHIX RC 105 Pro 9070537 Motion detector surface frame UXA 103-200 UXA 103-200 T Surface frame UXA 103-200 9070504 UA star adapter plate The adapter plate simpli es the replacement of faulty twilight switches from Eberle, ESYUX, egrand, Grässlin, Hager, Merten, Senmatic, Theben etc. The plate has standard xing holes, so no further holes need to be drilled in the facade. 2 installation screws included UA 126 star UA 127 star UA 128 star UA 129 star-time UA star adapter plate 9070486 Surface-mounted light sensor Rotating sensor With mounting bracket and terminal screws Protection rating IP 54 UA 108 UXOR 411 UA 130 KX Surface-mounted light sensor 9070008 14 httpadditional technical data at: www.theben.de/product/ Article number 235

ACCESSORIES Analogue surface-mounted light sensor Rotating sensor Quick fastening Description Suitable for Type Article number With mounting bracket and screw terminals Protection rating IP 55 UA 108 UA 109 UA 110 UA 120 top2 Analogue surfacemounted light sensor 9070416 Digital surface-mounted light sensor Rotating sensor Quick fastening With mounting bracket and screw terminals Protection rating IP 55 UA 111 top2 UA 112 top2 UA 121 top2 RC UA 122 top2 RC Digital surfacemounted light sensor 9070415 Analogue ush-mounted light sensor Connecting cable 1.5 m Protection rating IP 65 UA 108 UA 109 UA 110 UA 120 top2 Analogue ushmounted light sensor 9070011 Digital ush-mounted light sensor Screwless terminals Protection rating IP 66 UA 111 top2 UA 112 top2 UA 121 top2 RC UA 122 top2 RC Digital ush-mounted light sensor 9070456 Flush-mounted light sensor UA KX Connecting cable 1.5 m, protection rating IP 65 UA 130 KX Flush-mounted light sensor UA KX 9070247 Power unit CO 2 sensor 24 V/12 W ush-mounted power unit AMU 716 R Power unit CO 2 sensor (Available May 2010) 9070494 Adapter RAMSES 72x/78x Wallpaper/wall cover plate for replacement of RAMSES 3 devices with new clock thermostats, e. g. RAMSES 722 All analogue clock thermostats Adapter RAMSES 72x/78x 9070245 Adapter plate RAMSES 70x Adapter plate for ush-mounted socket 79 x 79 mm RAMSES 701 709 Adapter plate RAMSES 70x 9070480 14 Adapter plate RAMSES 714 Adapter plate for ush-mounted socket 79 x 79 mm SOTHIS 715 RAMSES 714 RAMSES 714 A RAMSES 714 A/FH Adapter plate RAMSES 714 9070212 http Additional technical data at: 236 www.theben.de/product/ Article number

ACCESSORIES Flow temperature sensor Description Suitable for Type Article number Also required for applications with 2 feed sensors RAMSES 855 top2 OT RAMSES OT Center Flow temperature sensor 9070371 Antenna RAMSES 813/833 External temperature sensor 1 For 868 MHz with wall holder and 2 m screened connection cable (only required in event of poor reception quality). External temperature sensor RAMSES 813 top2 HF Set 1 RAMSES 833 top2 HF Set 1 RAMSES 833 top2 HF Set 2 All RAMSES with external inputs CHEOPS control KX CHEOPS drive KX RAMSES 713 S KX Antenna RAMSES 813/833 External temperature sensor 1 9070334 9070191 External temperature sensor 2 With temperature adjustment of ± 3 K All RAMSES with external inputs External temperature sensor 2 9070192 External temperature sensor IP 65 External temperature sensor Protection rating IP 65 All RAMSES with external inputs External temperature sensor IP 65 9070459 Temperature sensor GSM modem Temperature sensor for laying in oor RAMSES 712 KX RAMSES 713 S KX FCA 1 KX RAMSES 831 top2 RAMSES 832 top2 RAMSES 833 top2 HF Set 1/Set 2 Temperature sensor 9070321 Incl. antenna, power unit and connecting cables RAMSES 816 top RAMSES 817 top RAMSES 855 top GSM modem 9070396 RAMSES OT Center Extends the RAMSES 855 top with an additional mixer circuit, chimney sweep function, and a relay output for error messages RAMSES 855 top2 OT RAMSES OT Center 9070427 14 httpadditional technical data at: www.theben.de/product/ Article number 237

ACCESSORIES Frame RAMSES 74x Description Suitable for Type Article number Frame for mechanical clock thermostat Without central part RAMSES 741 RAMSES 746 RAMSES 748 Frame RAMSES 74x 9070603 Socket RAMSES Plug-in socket for installing the RAMSES HF clock thermostat on the wall RAMSES 813 top2 HF Set A/Set S/Set 1 RAMSES 833 top2 HF Set 1/Set2 Socket RAMSES 9070605 Actuator APHA 4 230 V Actuator APHA 4 24 V Actuator for radiators, heating circuit distributors or individual heating circuits Operating voltage 230 V AC "First open function" for easy installation and heating start-up Plug-in installation on valve adapters 100 % protection against damaging drives through leaking valves Function and adjustment checking Protection against disassembly by means of removable SaveGuard Guaranteed overvoltage protection All RAMSES HMG 4 KX HME 4 KX Actuator APHA 4 230 V 9070438 ike actuator APHA 4 230 V, however: Operating voltage 24 V All RAMSES HMG 4 KX HME 4 KX HMT 6 KX HMT 12 KX Actuator APHA 4 24 V 9070439 Plunge sensor RAMSES Additionally required for applications with service water control or boiler plunge sensor RAMSES 855 top2 OT Plunge sensor RAMSES 9070379 Valve adapter VA 78 Valve adapter for Danfoss RA Further valve adapters available upon request Actuator APHA 4 230 V/24 V CHEOPS control KX CHEOPS drive KX Valve adapter VA 78 9070436 Valve adapter VA 80 Valve adapters for Onda, Schlösser(from 1993), Oventrop (M30 x 1.5), Heimeier, Herb, Therm- Concept, Frank, Roth (distributor), Dinotherm (distributor). Further valve adapters available upon request Actuator APHA 4 230 V/24 V CHEOPS control KX CHEOPS drive KX Valve adapter VA 80 9070437 14 Central part RAMSES 741/748 Central part without switch section and setting button RAMSES 741 RAMSES 748 Central part RAMSES 741/748 9070602 http Additional technical data at: 238 www.theben.de/product/ Article number

ACCESSORIES Central part RAMSES 746 Description Suitable for Type Article number Central part with switch section and setting button RAMSES 746 Central part RAMSES 746 9070601 Mast mounting weather station For mast installation of the weather station Diameter 60 80 mm UXOR 412 UXOR 413 Weather station KX Weather station basic KX Mast mounting weather station 9070380 Diode module UXOR Required for special functions (group/central function) 2 items included in delivery UXOR 400 UXOR 402 UXOR 404 UXOR 408 UXOR 409 Diode module UXOR 9070367 GSM cable PHARAO-II Enables connection to be established and SMS data to be transmitted to mobile telephone, email address or fax machine. All PHARAO controls GSM cable PHARAO-II 9070329 Power unit 24 V DC Power pack for supply voltage from PHARAO controllers and sensors. Power unit suf cient for 5 x PhARAO-II 14/15 or 4 x PHARAO-II 24/25 controls Width 3 modules (52.5 mm) UA 131 DDC UXOR 413 All PHARAO controls Power unit 24 V DC 9079330 Programming software PHARAO Software for PHARAO and PHARAO-II Generation CD for Windows 95/98/T/2000/ME/XP All PHARAO controls Programming software PHARAO 9070251 Programming cable PHARAO For series connection (RS 232) to enable control programs to be con gured and parameterised. This cable is used to connect an analogue model for remote maintenance and remote control. All PHARAO controls Programming cable PHARAO 9070252 Memory module PHARAO-II Plug-in external EEPROM memory module 5kB for transferring and/or downloading the program from or to the internal EEPROM system memory. Internal program is deactivated for as long as the external memory module is plugged in (dual programming). All PHARAO controls Memory module PHARAO-II 9070328 14 httpadditional technical data at: www.theben.de/product/ Article number 239

A E Index 2010/2011 Type Article number EA/GTI number Page A Actuator APHA 4 230 V 9070438 4003468904244 238 Actuator APHA 4 24 V 9070439 4003468904251 238 Adapter plate RAMSES 70x 9070480 4003468904299 236 Adapter plate RAMSES 714 9070212 4003468900796 236 Adapter RAMSES 72x/78x 9070245 4003468902059 236 AMU 716 KX 7169200 4003468716205 187 AMU 716 R 7160101 4003468716250 162 AMU 716 USB 7169101 4003468716106 162 Analogue ush-mounted light sensor 9070011 4003468900604 236 Analogue surface-mounted light sensor 9070416 4003468904275 236 Antenna DCF77 9070243 4003468900512 228 Antenna DCF77 KX 9070271 4003468903056 228 Antenna RAMES 813/833 9070334 4003468909447 237 Antenna top2 RC-DCF 9070410 4003468904077 228 Antenna top2 RC-GPS 9070610 4003468903254 228 B BME 6 KX 4910231 4003468491317 178 BMG 6 KX 4910230 4003468491300 178 Bus coupling unit KX 9070524 7612748000629 232 BZ 142-1 1420721 4003468140017 58 BZ 142-1 110V 1421721 4003468140604 58 BZ 142-1 240V 1420621 4003468140086 58 BZ 142-1 24V 1424721 4003468140932 58 BZ 142-3 1420723 4003468140024 58 BZ 143-1 1430721 4003468140130 58 BZ 145 1450000 4003468140918 58 BZ 145 24V 1459024 4003468141021 58 BZ 146 1460000 4003468146002 60 BZ 147 1470000 4003468147009 60 BZ 147 24V 1479000 4003468147023 60 BZ 148 1480000 4003468148006 60 C Central part RAMSES 741/748 9070602 4003468904589 238 Central part RAMSES 746 9070601 4003468904572 239 CHEOPS control KX 7329201 4003468732014 186 CHEOPS drive KX 7319200 4003468731000 186 Clamp BZ 9070043 4003468900703 231 clic 9070515 7612748000919 233 compact of ce 2010000 7612748000698 68 compact of ce 24V 2014000 7612748001039 90 compact of ce 24V BK 2014800 7612748002777 90 compact of ce 24V ux 2014001 7612748001121 92 compact of ce 24V ux BK 2014803 7612748002807 92 compact of ce 24V ux SR 2014804 7612748002814 92 compact of ce 24V SR 2014801 7612748002784 90 compact of ce BK 2010800 7612748002685 68 compact of ce DIM 2010001 7612748000773 70 compact of ce DIM BK 2010803 7612748002715 70 compact of ce DIM SR 2010804 7612748002722 70 compact of ce EIB 2019200 7612748000940 192 compact of ce EIB BK 2019800 7612748002869 192 compact of ce EIB SR 2019801 7612748002876 192 compact of ce SR 2010801 7612748002692 68 compact passage 2010090 7612748001626 72 compact passage 24V 2014090 7612748001725 94 compact passage 24V BK 2014806 7612748002838 94 compact passage 24V SR 2014807 7612748002845 94 Type Article number EA/GTI number Page compact passage BK 2010806 7612748002746 72 compact passage KX 2019290 7612748001732 192 compact passage KX BK 2019803 7612748002890 192 compact passage KX SR 2019804 7612748002906 192 compact passage SR 2010807 7612748002753 72 compact passimo BK 2010809 7612748003361 74 compact passimo KX BK 2019809 7612748003446 194 compact passimo KX SR 2019810 7612748003453 194 compact passimo KX WH 2019280 7612748003439 194 compact passimo SR 2010810 7612748003378 74 compact passimo WH 2010080 7612748003354 74 Cover 55 x 55 for BZ 9070041 4003468902004 231 Cover 72 x 72 for BZ 9070074 4003468900925 231 D Digital ush-mounted light sensor 9070456 4003468904343 236 Digital surface-mounted light sensor 9070415 4003468904268 236 Diode module UXOR 9070367 4003468903605 239 DMB 2 S KX 4910272 4003468491720 174 DME 2 S KX 4910271 4003468491713 174 DMG 2 S KX 4910270 4003468491706 174 E ECO-IR 180A 2020050 7612748000476 88 ECO-IR 180A BK 2020809 7612748002111 88 ECO-IR 180A SR 2020810 7612748002128 88 ECO-IR 180A-24V 2024050 7612748000537 98 ECO-IR 180A-24V BK 2024803 7612748002234 98 ECO-IR 180A-24V SR 2024804 7612748002241 98 ECO-IR 180EIB-AC 2029250 7612748000599 196 ECO-IR 180EIB-AC BK 2029809 7612748002357 196 ECO-IR 180EIB-AC SR 2029810 7612748002364 196 ECO-IR 360-24V 2024000 7612748000544 96 ECO-IR 360-24V BK 2024800 7612748002203 96 ECO-IR 360-24V SR 2024801 7612748002210 96 ECO-IR 360A 2020000 7612748000483 76 ECO-IR 360A BK 2020806 7612748002081 76 ECO-IR 360A SR 2020807 7612748002098 76 ECO-IR 360C T 2020400 7612748000834 78 ECO-IR 360C T BK 2020812 7612748002142 78 ECO-IR 360C T SR 2020813 7612748002159 78 ECO-IR 360EIB-AC 2029201 7612748000605 198 ECO-IR 360EIB-AC BK 2029803 7612748002296 198 ECO-IR 360EIB-AC SR 2029804 7612748002302 198 ECO-IR DUA-C T 2020401 7612748000872 80 ECO-IR DUA-C T BK 2020815 7612748002173 80 ECO-IR DUA-C T SR 2020816 7612748002180 80 ECO-IR DUA-EIB 2029200 7612748000612 198 ECO-IR DUA-EIB BK 2029800 7612748002265 198 ECO-IR DUA-EIB SR 2029801 7612748002272 198 EPA 041 0410002 4003468041000 132 EPA 047 0470002 4003468047002 132 EPA 1 0010002 4003468010518 128 EPA 3 0030002 4003468010501 128 EPA 4 0040001 4003468010457 130 EPA 6 0060002 4003468010525 128 EPA 7 0070002 4003468007006 128 EPA 8 0080002 4003468010068 130 EPA 9 0090001 4003468010129 130 EM 4 top2 6490104 4003468649008 20 EM A top2 6490900 4003468649015 20 240

Index 2010/2011 F P Type Article number EA/GTI number Page External temperature sensor 1 9070191 4003468901915 237 External temperature sensor 2 9070192 4003468901922 237 External temperature sensor IP 65 9070459 4003468903810 237 F FCA 1 KX 4920200 4003468492000 189 Flow temperature sensor 9070371 4003468903629 237 Flush-mounted light sensor UA KX 9070247 4003468902882 236 Frame RAMSES 74x 9070603 4003468904596 238 FRI 77 g 0770033 4003468070024 52 FRI 77 g-2 0770832 4003468070086 52 FRI 77 h 0770008 4003468070017 52 FRI 77 h-2 0770802 4003468070048 52 Front panel kit 9070001 4003468900109 228 Front-kit BZ 142-3 9070075 4003468900932 231 G GSM cable PHARAO-II 9070329 4003468903483 239 GSM modem 9070396 4003468903407 237 H HME 4 KX 4910211 4003468491119 184 HMG 4 KX 4910210 4003468491102 184 HMT 12 KX 4900274 4003468490549 185 HMT 6 KX 4900273 4003468490532 185 I Interface USB KX 9070397 4003468903995 209 J JME 4 24V DC KX 4900254 4003468490594 177 JME 4 S KX 4910251 4003468491515 177 JMG 4 24V DC KX 4900253 4003468490587 176 JMG 4 S KX 4910250 4003468491508 176 Junction casing 115 x 115 x 100 mm 9070689 7612748002661 233 ine coupler KX 9070398 4003468904008 209 UA 108 A 1080710 4003468108017 116 UA 108 E 1080700 4003468108000 116 UA 109 A 1090100 4003468109007 116 UA 109 E 1090200 4003468109014 116 UA 110 A 1100100 4003468111109 116 UA 110 A 1104100 4003468111161 116 UA 110 E 1100200 4003468111154 116 UA 111 top2 A 1110100 4003468111147 118 UA 111 top2 E 1110200 4003468111116 118 UA 112 top2 A 1120100 4003468112007 118 UA 112 top2 E 1120200 4003468112014 118 UA 120 top2 A 1200100 4003468120002 120 UA 120 top2 E 1200200 4003468120019 120 UA 121 top2 RC A 1210100 4003468121009 120 UA 121 top2 RC E 1210200 4003468121016 120 UA 122 top2 RC A 1220100 4003468122006 120 UA 122 top2 RC E 1220200 4003468122013 120 UA 126 star 1260701 4003468126035 122 UA 127 star 1270700 4003468127001 122 UA 128 star 1280700 4003468128008 122 UA 129 star-time 1290700 4003468129005 122 UA 130 KX A 1309200 4003468130018 201 UA 131 DDC 1319700 4003468131022 226 UA 131 S KX 1319201 4003468131039 202 UA 133 KX 1339200 4003468133002 203 UA star adpater plate 9070486 4003468907559 235 Type Article number EA/GTI number Page UXA 101-150 1010963 4003468101025 102 UXA 101-150 1010964 4003468101032 102 UXA 101-180 1010961 4003468101001 102 UXA 101-180 1010962 4003468101018 102 UXA 101-360 1010460 4003468101049 106 UXA 102-150/150W 1020961 4003468102008 104 UXA 102-150/150W 1020962 4003468102015 104 UXA 102-150/500W 1020963 4003468102022 104 UXA 102-150/500W 1020964 4003468102039 104 UXA 103-200 1030030 4003468103043 114 UXA 103-200 T 1030031 4003468103050 114 UXA 103-360 1030010 4003468103005 110 UXA 103-360 AP 1030020 4003468103029 112 UXA 103-360/2 1030011 4003468103012 110 UXA 103-360/2 AP 1030021 4003468103036 112 UXA corner angle black 9070625 4003468909522 234 UXA corner angle white 9070626 4003468909515 234 UXOR 400 4000000 4003468400005 214 UXOR 402 4020000 4003468402009 214 UXOR 404 4040000 4003468404003 214 UXOR 405 4050000 4003468405000 216 UXOR 408 4080000 4003468408001 217 UXOR 409 4090000 4003468409008 217 UXOR 411 4110000 4003468411001 218 UXOR 412 4120000 4003468412008 218 UXOR 413 4130000 4003468413005 218 UXOR 414 4140000 4003468414002 220 UXOR Set 3 4990003 4003468499030 221 UXOR Set 4 4990004 4003468499047 221 M Mast mounting weather station 9070380 4003468903742 239 MEM 190 a 1900001 4003468190050 32 MEM 198 h 1980008 4003468190135 38 Memory card OBEISK 9070165 4003468901656 230 Memory card OBEISK KX 16 K 9070223 4003468902417 229 Memory card OBEISK KX 64 K 9070320 4003468903315 230 Memory card OBEISK top2 9070404 4003468904053 230 Memory module PHARAO-II 9070328 4003468903414 239 O OBEISK KX PC set 9070305 4003468903070 229 OBEISK PC set 9070230 4003468903001 229 OBEISK top2 PC set 9070409 4003468904015 229 OSIRIA 220 AR KX 5009200 4003468500057 210 OSIRIA 230 AR KX 5009210 4003468500071 210 OSIRIA 230 SR KX 5009211 4003468500088 210 OSIRIA 232 BQ KX 5009223 4003468500293 210 OSIRIA 240 AR KX 5009230 4003468500132 210 OSIRIA 240 SR KX 5009231 4003468500149 210 OSIRIA 241 AR KX 5009240 4003468500170 210 OSIRIA 241 BR KX 5009241 4003468500187 210 OSIRIA 242 AR KX 5009250 4003468500194 210 OSIRIA 242 SR KX 5009251 4003468500200 210 OSIRIA 251 BQ KX 5009252 4003468500279 210 OSIRIA 280 B KX 5009280 4003468500217 210 OT-Center RAMSES 9070427 4003468904497 237 P PHARAO-II 10 (AC) 5750210 4003468575185 224 PHARAO-II 11 (DC) 5759211 4003468575192 224 PHARAO-II 14 (AC) 5750014 4003468575093 224 241

Q S Index 2010/2011 Type Article number EA/GTI number Page PHARAO-II 15 (DC) 5759015 4003468575109 224 PHARAO-II 24 (AC) 5750024 4003468575116 224 PHARAO-II 25 (DC) 5759025 4003468575123 224 PHARAO-II Upgrade 4AR (AC) 5759102 4003468575154 224 PlanoCentro 000-EBK 2040103 7612748003286 82 PlanoCentro 000-ESR 2040104 7612748003293 82 PlanoCentro 000-EWH 2040102 7612748003279 82 PlanoCentro 000-UBK 2040203 7612748003323 82 PlanoCentro 000-USR 2040204 7612748003330 82 PlanoCentro 000-UWH 2040202 7612748003316 82 PlanoCentro 101-EBK 2030103 7612748002463 82 PlanoCentro 101-ESR 2030104 7612748002470 82 PlanoCentro 101-EWH 2030102 7612748002456 82 PlanoCentro 101-UBK 2030203 7612748002500 82 PlanoCentro 101-USR 2030204 7612748002517 82 PlanoCentro 101-UWH 2030202 7612748002494 82 Plug-in socket BZ 9070042 4003468900697 231 Plunge sensor RAMSES 9070379 4003468903711 238 Power unit 24 V DC 9079330 4003468903520 239 Power unit CO2 sensor 9070494 4003468904534 236 Power unit DCF77 9070182 4003468901694 229 Power unit top2 GPS 9070892 4003468904718 229 Power supply KX 160 ma 9070701 4003468904558 208 Power supply KX 320 ma 9070699 4003468904541 208 Power supply KX 640 ma 9070364 4003468903582 208 Programming cable PHARAO 9070252 4003468902851 239 Programming software PHARAO 9070251 4003468902844 239 Presenceight 180 2000050 7612748001602 86 Presenceight 180 BK 2000803 7612748002050 86 Presenceight 180 SR 2000804 7612748002067 86 Presenceight 360 2000000 7612748001107 64 Presenceight 360 BK 2000800 7612748002029 64 Presenceight 360 SR 2000801 7612748002036 64 Q QuickFix circular cover 9070517 7612748000568 233 QuickFix concrete circular cover 9070519 7612748000964 232 QuickFix concrete ush-mount box 9070521 7612748000742 233 QuickFix concrete ush-mount housing 9070522 7612748000551 233 QuickFix concrete square cover 9070518 7612748000971 232 QuickFix square cover 9070516 7612748000575 233 QuickSafe 9070531 7612748000582 233 QuickSet plus 9070532 7612748000926 234 R RAMSES 366/1 top 3660002 4003468360217 146 RAMSES 366/2 top 3660052 4003468360293 146 RAMSES 701 7010001 4003468701140 154 RAMSES 702 7020001 4003468702055 154 RAMSES 703 7030001 4003468703052 154 RAMSES 704 7040001 4003468704028 154 RAMSES 705 7050001 4003468705032 154 RAMSES 706 7060001 4003468706022 154 RAMSES 707 7070001 4003468707029 154 RAMSES 708 7080001 4003468708026 154 RAMSES 709 7090001 4003468709030 154 RAMSES 712 KX 7129200 4003468712009 183 RAMSES 713 FC KX 7139202 4003468713020 188 RAMSES 713 S KX 7139201 4003468713013 182 RAMSES 714 7140002 4003468714126 158 Type Article number EA/GTI number Page RAMSES 714 A 7140016 4003468714133 158 RAMSES 714 A/FH 7140017 4003468714270 158 RAMSES 721 7210030 4003468721018 150 RAMSES 722 7220030 4003468722015 150 RAMSES 722 S 7220801 4003468722022 148 RAMSES 725 7250030 4003468725016 150 RAMSES 741 7410130 4003468741023 156 RAMSES 741 RA 7410131 4003468741030 156 RAMSES 746 7460130 4003468746028 156 RAMSES 746 RA 7460131 4003468746035 156 RAMSES 748 7480130 4003468748022 156 RAMSES 748 RA 7480131 4003468748039 156 RAMSES 751 RA 7510131 4003468751008 158 RAMSES 770 KX 7709200 4003468770009 181 RAMSES 782 7820030 4003468782019 150 RAMSES 782 S 7820801 4003468782026 148 RAMSES 784 7840030 4003468784013 150 RAMSES 784 S 7840801 4003468784020 148 RAMSES 811 top2 8119132 4003468811139 136 RAMSES 812 top2 8120132 4003468812037 138 RAMSES 813 top2 HF Set 1 8139501 4003468813218 140 RAMSES 813 top2 HF Set A 8139503 4003468813164 140 RAMSES 813 top2 HF Set S 8139505 4003468813188 140 RAMSES 831 top2 8319132 4003468831052 136 RAMSES 832 top2 8320132 4003468832035 138 RAMSES 833 top2 HF Set 1 8339501 4003468833049 142 RAMSES 833 top2 HF Set 2 8339502 4003468833056 142 RAMSES 855 top2 OT 8559132 4003468855010 144 RC lter 9070523 7612748001701 232 RME 4 C-oad KX 4910207 4003468491072 170 RME 4 I KX 4930215 4003468493090 168 RME 4 S KX 4910205 4003468491058 171 RME 8 KX 4900252 4003468490457 172 RME 8 S KX 4930225 4003468493076 169 RMG 4 C-oad KX 4910206 4003468491065 170 RMG 4 I KX 4930210 4003468493083 168 RMG 4 S KX 4910204 4003468491041 171 RMG 8 KX 4900251 4003468490440 172 RMG 8 S KX 4930220 4003468493069 169 S SEEKTA 170 top2 1700100 4003468170533 16 SEEKTA 170 top2 24V 1704100 4003468170564 16 SEEKTA 171 top2 RC 1710100 4003468171004 16 SEEKTA 171 top2 RC 24V 1714100 4003468171035 16 SEEKTA 172 top2 1720100 4003468172001 16 SEEKTA 172 top2 24V 1724100 4003468172056 16 SEEKTA 173 DCF 1730001 4003468173008 21 SendoClic 9070690 7612748002678 234 SendoPro 868-A 9070675 7612748002524 234 SME 2 S KX 4910274 4003468491744 173 SMG 2 S KX 4910273 4003468491737 173 Snap-on mounting 72 x 72 9070071 4003468900895 229 Socket RAMSES 9070605 4003468904657 238 SOTHIS 715 7150002 4003468715024 164 SPHIX 104-360 1040370 4003468104026 66 SPHIX 104-360 AP 1040360 4003468104002 66 SPHIX 104-360/2 1040372 4003468104033 66 SPHIX 104-360/2 AP 1040362 4003468104019 66 SPHIX 105-110 1050110 4003468105009 108 242

Index 2010/2011 T Z Type Article number EA/GTI number Page SPHIX 105-220 1050220 4003468105016 108 SPHIX 105-300 1050300 4003468105023 108 SPHIX 105-300 KX 1059203 4003468105030 191 SPHIX 331 KX 1079211 4003468107058 190 SPHIX 332 KX 1079212 4003468107065 190 SPHIX corner angle 9070535 4003468904398 234 SPHIX RC 104 9070538 4003468904428 235 SPHIX RC 104 Pro 9070536 4003468904404 235 SPHIX RC 105 9070539 4003468904435 235 SPHIX RC 105 Pro 9070537 4003468904411 235 SUD 228 II 2280577 4003468228012 226 SU 180 a 1800001 4003468183311 32 SU 181 d 1810011 4003468182383 34 SU 181 h 1810008 4003468180051 36 SU 181 h 12V 1817008 4003468181980 36 SU 181 h 24V 1814008 4003468182505 36 SU 188 g 1880033 4003468181003 40 SU 188 h 1880008 4003468180983 38 SU 188 hw 1880108 4003468181010 40 SU 189 hw 1890108 4003468181164 46 SU 189 s 1890801 4003468180631 42 SU 189 s 110V 1891801 4003468182093 42 SU 191 w 1910011 4003468191040 34 SU 285/1 T 2850008 4003468285015 48 SU 285/2 T 2850033 4003468285022 48 SU 289 g 2890033 4003468280096 44 SU 289 h 2890008 4003468280089 44 Surface frame compact 9070514 7612748000711 232 Surface frame ECO-IR 180 9070511 7612748000735 231 Surface frame ECO-IR 360 9070512 7612748000728 232 Surface frame Presenceight 9070513 7612748001145 232 Surface-mounted light sensor 9070008 4003468900574 235 SY 151 h 1510011 4003468151006 34 SY 160 a 1600001 4003468161609 32 SY 161 d 1610011 4003468161371 36 SY 161 h 1610008 4003468160039 36 SY 168 h 1680008 4003468160381 38 SY 169 s 1690801 4003468160633 38 SY 269 g 2690033 4003468260029 44 SY 269 h 2690008 4003468260012 44 T TA 2 KX 4969202 4003468496022 179 TA 4 KX 4969204 4003468496046 179 TA 6 KX 4969206 4003468496060 179 Temperature sensor 9070321 4003468903360 237 Terminal cover 52,5 mm 9070061 4003468900802 228 theben-eltimo 020 S 0200000 4003468022313 28 theben-eltimo 020 S DCF 0200300 4003468024034 28 theben-timer 26 0260030 4003468020821 50 theben-timer 26 IP 44 0260855 4003468020166 50 theben-timer 27 0270930 4003468020869 50 TM 171 h 1710008 4003468170038 36 TM 178 h 1780008 4003468170144 36 TM 179 h 1790008 4003468170151 46 TM 345 B 3450730 4003468340103 56 TM 345 M 3450731 4003468340110 56 TR 030 top 0300002 4003468030073 27 TR 608 top 6080002 4003468608081 14 TR 610 top 24V 6104002 4003468611746 15 Type Article number EA/GTI number Page TR 610 top2 6100100 4003468611814 10 TR 610 top2 24V 6104100 4003468613009 10 TR 610 top2 G 6100110 4003468612590 10 TR 611 top2 6110100 4003468611821 12 TR 611 top2 24V 6114100 4003468613016 12 TR 611 top2 RC 6110300 4003468611838 12 TR 611 top2 RC 24V 6114300 4003468612231 12 TR 612 S KX 6129201 4003468611203 206 TR 612 top 24V 6124002 4003468612484 15 TR 612 top2 6120100 4003468611845 10 TR 612 top2 24V 6124100 4003468613023 10 TR 622 top2 6220100 4003468611852 12 TR 622 top2 24V 6224100 4003468613030 12 TR 635 top 6350002 4003468630556 24 TR 636 top 6360002 4003468630563 24 TR 641 S 6410001 4003468641064 22 TR 641 S 12V 6419012 4003468641040 22 TR 641 S DCF 6410301 4003468641071 22 TR 641 top2 6410100 4003468641088 18 TR 641 top2 RC 6410300 4003468641026 18 TR 642 S 6420001 4003468642061 22 TR 642 S DCF 6420301 4003468642078 22 TR 642 top2 6420100 4003468642085 18 TR 642 top2 RC 6420300 4003468642023 18 TR 644 S 6440001 4003468644164 22 TR 644 S 120V 6448110 4003468644065 22 TR 644 S 12V 6448012 4003468644102 22 TR 644 S 24V 6448024 4003468644072 22 TR 644 S DCF 6440301 4003468644171 22 TR 644 S DCF KX 6449204 4003468644195 204 TR 644 S KX 6449203 4003468644188 204 TR 644 top2 6440100 4003468644232 18 TR 644 top2 RC 6440300 4003468644027 18 TR 648 S DCF KX 6489201 4003468648018 204 TR 685/2 top 6850012 4003468685136 26 V Valve adapter VA 78 9070436 4003468904220 238 Valve adapter VA 80 9070437 4003468904237 238 VARIA 824 KX 8249200 4003468824009 180 VARIA 826 KX 8269200 4003468826003 180 VARIA 826 KX 8269201 4003468826010 180 W Wall mounting kit 105 mm 9070053 4003468902363 231 Wall mounting kit 17,5 mm 9070065 4003468900833 230 Wall mounting kit 35 mm 9070064 4003468900826 230 Wall mounting kit 52,5 mm 9070050 4003468900734 230 Wall mounting kit 70 mm 9070049 4003468900727 230 Weather station basic KX 1329205 4003468132043 201 Weather station KX 1329201 4003468132029 201 Z ZS 600 DCF KX 6009200 4003468600009 207 243

0010002 2000803 Index 2010/2011 Article number Type EA/GTI number Page 0010002 EPA 1 4003468010518 128 0030002 EPA 3 4003468010501 128 0040001 EPA 4 4003468010457 130 0060002 EPA 6 4003468010525 128 0070002 EPA 7 4003468007006 128 0080002 EPA 8 4003468010068 130 0090001 EPA 9 4003468010129 130 0200000 theben-eltimo 020 S 4003468022313 28 0200300 theben-eltimo 020 S DCF 4003468024034 28 0260030 theben-timer 26 4003468020821 50 0260855 theben-timer 26 IP 44 4003468020166 50 0270930 theben-timer 27 4003468020869 50 0300002 TR 030 top 4003468030073 27 0410002 EPA 041 4003468041000 132 0470002 EPA 047 4003468047002 132 0770008 FRI 77 h 4003468070017 52 0770033 FRI 77 g 4003468070024 52 0770802 FRI 77 h-2 4003468070048 52 0770832 FRI 77 g-2 4003468070086 52 1010460 UXA 101-360 4003468101049 106 1010961 UXA 101-180 4003468101001 102 1010962 UXA 101-180 4003468101018 102 1010963 UXA 101-150 4003468101025 102 1010964 UXA 101-150 4003468101032 102 1020961 UXA 102-150/150W 4003468102008 104 1020962 UXA 102-150/150W 4003468102015 104 1020963 UXA 102-150/500W 4003468102022 104 1020964 UXA 102-150/500W 4003468102039 104 1030010 UXA 103-360 4003468103005 110 1030011 UXA 103-360/2 4003468103012 110 1030020 UXA 103-360 AP 4003468103029 112 1030021 UXA 103-360/2 AP 4003468103036 112 1030030 UXA 103-200 4003468103043 114 1030031 UXA 103-200 T 4003468103050 114 1040360 SPHIX 104-360 AP 4003468104002 66 1040362 SPHIX 104-360/2 AP 4003468104019 66 1040370 SPHIX 104-360 4003468104026 66 1040372 SPHIX 104-360/2 4003468104033 66 1050110 SPHIX 105-110 4003468105009 108 1050220 SPHIX 105-220 4003468105016 108 1050300 SPHIX 105-300 4003468105023 108 1059203 SPHIX 105-300 KX 4003468105030 191 1079211 SPHIX 331 KX 4003468107058 190 1079212 SPHIX 332 KX 4003468107065 190 1080700 UA 108 E 4003468108000 116 1080710 UA 108 A 4003468108017 116 1090100 UA 109 A 4003468109007 116 1090200 UA 109 E 4003468109014 116 1100100 UA 110 A 4003468111109 116 1100200 UA 110 E 4003468111154 116 1104100 UA 110 A 4003468111161 116 1110100 UA 111 top2 A 4003468111147 118 1110200 UA 111 top2 E 4003468111116 118 1120100 UA 112 top2 A 4003468112007 118 1120200 UA 112 top2 E 4003468112014 118 1200100 UA 120 top2 A 4003468120002 120 1200200 UA 120 top2 E 4003468120019 120 1210100 UA 121 top2 RC A 4003468121009 120 1210200 UA 121 top2 RC E 4003468121016 120 Article number Type EA/GTI number Page 1220100 UA 122 top2 RC A 4003468122006 120 1220200 UA 122 top2 RC E 4003468122013 120 1260701 UA 126 star 4003468126035 122 1270700 UA 127 star 4003468127001 122 1280700 UA 128 star 4003468128008 122 1290700 UA 129 star-time 4003468129005 122 1309200 UA 130 KX A 4003468130018 201 1319201 UA 131 S KX 4003468131039 202 1319700 UA 131 DDC 4003468131022 226 1329201 Weather station KX 4003468132029 201 1329205 Weather station basic KX 4003468132043 201 1339200 UA 133 KX 4003468133002 203 1420621 BZ 142-1 240V 4003468140086 58 1420721 BZ 142-1 4003468140017 58 1420723 BZ 142-3 4003468140024 58 1421721 BZ 142-1 110V 4003468140604 58 1424721 BZ 142-1 24V 4003468140932 58 1430721 BZ 143-1 4003468140130 58 1450000 BZ 145 4003468140918 58 1459024 BZ 145 24V 4003468141021 58 1460000 BZ 146 4003468146002 60 1470000 BZ 147 4003468147009 60 1479000 BZ 147 24V 4003468147023 60 1480000 BZ 148 4003468148006 60 1510011 SY 151 h 4003468151006 34 1600001 SY 160 a 4003468161609 32 1610008 SY 161 h 4003468160039 36 1610011 SY 161 d 4003468161371 36 1680008 SY 168 h 4003468160381 38 1690801 SY 169 s 4003468160633 38 1700100 SEEKTA 170 top2 4003468170533 16 1704100 SEEKTA 170 top2 24V 4003468170564 16 1710008 TM 171 h 4003468170038 36 1710100 SEEKTA 171 top2 RC 4003468171004 16 1714100 SEEKTA 171 top2 RC 24V 4003468171035 16 1720100 SEEKTA 172 top2 4003468172001 16 1724100 SEEKTA 172 top2 24V 4003468172056 16 1730001 SEEKTA 173 DCF 4003468173008 21 1780008 TM 178 h 4003468170144 36 1790008 TM 179 h 4003468170151 46 1800001 SU 180 a 4003468183311 32 1810008 SU 181 h 4003468180051 36 1810011 SU 181 d 4003468182383 34 1814008 SU 181 h 24V 4003468182505 36 1817008 SU 181 h 12V 4003468181980 36 1880008 SU 188 h 4003468180983 38 1880033 SU 188 g 4003468181003 40 1880108 SU 188 hw 4003468181010 40 1890108 SU 189 hw 4003468181164 46 1890801 SU 189 s 4003468180631 42 1891801 SU 189 s 110V 4003468182093 42 1900001 MEM 190 a 4003468190050 32 1910011 SU 191 w 4003468191040 34 1980008 MEM 198 h 4003468190135 38 2000000 Presenceight 360 7612748001107 64 2000050 Presenceight 180 7612748001602 86 2000800 Presenceight 360 BK 7612748002029 64 2000801 Presenceight 360 SR 7612748002036 64 2000803 Presenceight 180 BK 7612748002050 86 244

Index 2010/2011 2000804 4969202 Article number Type EA/GTI number Page 2000804 Presenceight 180 SR 7612748002067 86 2010000 compact of ce 7612748000698 68 2010001 compact of ce DIM 7612748000773 70 2010080 compact passimo WH 7612748003354 74 2010090 compact passage 7612748001626 72 2010800 compact of ce BK 7612748002685 68 2010801 compact of ce SR 7612748002692 68 2010803 compact of ce DIM BK 7612748002715 70 2010804 compact of ce DIM SR 7612748002722 70 2010806 compact passage BK 7612748002746 72 2010807 compact passage SR 7612748002753 72 2010809 compact passimo BK 7612748003361 74 2010810 compact passimo SR 7612748003378 74 2014000 compact of ce 24V 7612748001039 90 2014001 compact of ce 24V ux 7612748001121 92 2014090 compact passage 24V 7612748001725 94 2014800 compact of ce 24V BK 7612748002777 90 2014801 compact of ce 24V SR 7612748002784 90 2014803 compact of ce 24V ux BK 7612748002807 92 2014804 compact of ce 24V ux SR 7612748002814 92 2014806 compact passage 24V BK 7612748002838 94 2014807 compact passage 24V SR 7612748002845 94 2019200 compact of ce EIB 7612748000940 192 2019280 compact passimo KX WH 7612748003439 194 2019290 compact passage KX 7612748001732 194 2019800 compact of ce EIB BK 7612748002869 192 2019801 compact of ce EIB SR 7612748002876 192 2019803 compact passage KX BK 7612748002890 194 2019804 compact passage KX SR 7612748002906 194 2019809 compact passimo KX BK 7612748003446 194 2019810 compact passimo KX SR 7612748003453 194 2020000 ECO-IR 360A 7612748000483 76 2020050 ECO-IR 180A 7612748000476 88 2020400 ECO-IR 360C T 7612748000834 78 2020401 ECO-IR DUA-C T 7612748000872 80 2020806 ECO-IR 360A BK 7612748002081 76 2020807 ECO-IR 360A SR 7612748002098 76 2020809 ECO-IR 180A BK 7612748002111 88 2020810 ECO-IR 180A SR 7612748002128 88 2020812 ECO-IR 360C T BK 7612748002142 78 2020813 ECO-IR 360C T SR 7612748002159 78 2020815 ECO-IR DUA-C T BK 7612748002173 80 2020816 ECO-IR DUA-C T SR 7612748002180 80 2024000 ECO-IR 360-24V 7612748000544 96 2024050 ECO-IR 180A-24V 7612748000537 98 2024800 ECO-IR 360-24V BK 7612748002203 96 2024801 ECO-IR 360-24V SR 7612748002210 96 2024803 ECO-IR 180A-24V BK 7612748002234 98 2024804 ECO-IR 180A-24V SR 7612748002241 98 2029200 ECO-IR DUA-EIB 7612748000612 198 2029201 ECO-IR 360EIB-AC 7612748000605 198 2029250 ECO-IR 180EIB-AC 7612748000599 196 2029800 ECO-IR DUA-EIB BK 7612748002265 198 2029801 ECO-IR DUA-EIB SR 7612748002272 198 2029803 ECO-IR 360EIB-AC BK 7612748002296 198 2029804 ECO-IR 360EIB-AC SR 7612748002302 198 2029809 ECO-IR 180EIB-AC BK 7612748002357 196 2029810 ECO-IR 180EIB-AC SR 7612748002364 196 2030102 PlanoCentro 101-EWH 7612748002456 82 Article number Type EA/GTI number Page 2030103 PlanoCentro 101-EBK 7612748002463 82 2030104 PlanoCentro 101-ESR 7612748002470 82 2030202 PlanoCentro 101-UWH 7612748002494 82 2030203 PlanoCentro 101-UBK 7612748002500 82 2030204 PlanoCentro 101-USR 7612748002517 82 2040102 PlanoCentro 000-EWH 7612748003279 82 2040103 PlanoCentro 000-EBK 7612748003286 82 2040104 PlanoCentro 000-ESR 7612748003293 82 2040202 PlanoCentro 000-UWH 7612748003316 82 2040203 PlanoCentro 000-UBK 7612748003323 82 2040204 PlanoCentro 000-USR 7612748003330 82 2280577 SUD 228 II 4003468228012 226 2690008 SY 269 h 4003468260012 44 2690033 SY 269 g 4003468260029 44 2850008 SU 285/1 T 4003468285015 48 2850033 SU 285/2 T 4003468285022 48 2890008 SU 289 h 4003468280089 44 2890033 SU 289 g 4003468280096 44 3450730 TM 345 B 4003468340103 56 3450731 TM 345 M 4003468340110 56 3660002 RAMSES 366/1 top 4003468360217 146 3660052 RAMSES 366/2 top 4003468360293 146 4000000 UXOR 400 4003468400005 214 4020000 UXOR 402 4003468402009 214 4040000 UXOR 404 4003468404003 214 4050000 UXOR 405 4003468405000 216 4080000 UXOR 408 4003468408001 217 4090000 UXOR 409 4003468409008 217 4110000 UXOR 411 4003468411001 218 4120000 UXOR 412 4003468412008 218 4130000 UXOR 413 4003468413005 218 4140000 UXOR 414 4003468414002 220 4900251 RMG 8 KX 4003468490440 172 4900252 RME 8 KX 4003468490457 172 4900253 JMG 4 24V DC KX 4003468490587 177 4900254 JME 4 24V DC KX 4003468490594 177 4900273 HMT 6 KX 4003468490532 185 4900274 HMT 12 KX 4003468490549 185 4910204 RMG 4 S KX 4003468491041 171 4910205 RME 4 S KX 4003468491058 171 4910206 RMG 4 C-oad KX 4003468491065 170 4910207 RME 4 C-oadKX 4003468491072 170 4910210 HMG 4 KX 4003468491102 184 4910211 HME 4 KX 4003468491119 184 4910230 BMG 6 KX 4003468491300 178 4910231 BME 6 KX 4003468491317 178 4910250 JMG 4 S KX 4003468491508 176 4910251 JME 4 S KX 4003468491515 176 4910270 DMG 2 S KX 4003468491706 174 4910271 DME 2 S KX 4003468491713 174 4910272 DMB 2 S KX 4003468491720 174 4910273 SMG 2 S KX 4003468491737 173 4910274 SME 2 S KX 4003468491744 173 4920200 FCA 1 KX 4003468492000 189 4930210 RMG 4 I KX 4003468493083 168 4930215 RME 4 I KX 4003468493090 168 4930220 RMG 8 S KX 4003468493069 172 4930225 RME 8 S KX 4003468493076 172 4969202 TA 2 KX 4003468496022 179 245

4969204 9070042 Index 2010/2011 Article number Type EA/GTI number Page 4969204 TA 4 KX 4003468496046 179 4969206 TA 6 KX 4003468496060 179 4990003 UXOR Set 3 4003468499030 221 4990004 UXOR Set 4 4003468499047 221 5009200 OSIRIA 220 AR KX 4003468500057 210 5009210 OSIRIA 230 AR KX 4003468500071 210 5009211 OSIRIA 230 SR KX 4003468500088 210 5009223 OSIRIA 232 BQ KX 4003468500293 210 5009230 OSIRIA 240 AR KX 4003468500132 210 5009231 OSIRIA 240 SR KX 4003468500149 210 5009240 OSIRIA 241 AR KX 4003468500170 210 5009241 OSIRIA 241 BR KX 4003468500187 210 5009250 OSIRIA 242 AR KX 4003468500194 210 5009251 OSIRIA 242 SR KX 4003468500200 210 5009252 OSIRIA 251 BQ KX 4003468500279 210 5009280 OSIRIA 280 B KX 4003468500217 210 5750014 PHARAO-II 14 (AC) 4003468575093 224 5750024 PHARAO-II 24 (AC) 4003468575116 224 5750210 PHARAO-II 10 (AC) 4003468575185 224 5759015 PHARAO-II 15 (DC) 4003468575109 224 5759025 PHARAO-II 25 (DC) 4003468575123 224 5759102 PHARAO-II Upgrade 4AR (AC) 4003468575154 224 5759211 PHARAO-II 11 (DC) 4003468575192 224 6009200 ZS 600 DCF KX 4003468600009 207 6080002 TR 608 top 4003468608081 14 6100100 TR 610 top2 4003468611814 10 6100110 TR 610 top2 G 4003468612590 10 6104002 TR 610 top 24V 4003468611746 15 6104100 TR 610 top2 24V 4003468613009 10 6110100 TR 611 top2 4003468611821 12 6110300 TR 611 top2 RC 4003468611838 12 6114100 TR 611 top2 24V 4003468613016 12 6114300 TR 611 top2 RC 24V 4003468612231 12 6120100 TR 612 top2 4003468611845 10 6124002 TR 612 top 24V 4003468612484 15 6124100 TR 612 top2 24V 4003468613023 10 6129201 TR 612 S KX 4003468611203 206 6220100 TR 622 top2 4003468611852 12 6224100 TR 622 top2 24V 4003468613030 12 6350002 TR 635 top 4003468630556 24 6360002 TR 636 top 4003468630563 24 6410001 TR 641 S 4003468641064 22 6410100 TR 641 top2 4003468641088 18 6410300 TR 641 top2 RC 4003468641026 18 6410301 TR 641 S DCF 4003468641071 22 6419012 TR 641 S 12V 4003468641040 22 6420001 TR 642 S 4003468642061 22 6420100 TR 642 top2 4003468642085 18 6420300 TR 642 top2 RC 4003468642023 18 6420301 TR 642 S DCF 4003468642078 22 6440001 TR 644 S 4003468644164 22 6440100 TR 644 top2 4003468644232 18 6440300 TR 644 top2 RC 4003468644027 18 6440301 TR 644 S DCF 4003468644171 22 6448012 TR 644 S 12V 4003468644102 22 6448024 TR 644 S 24V 4003468644072 22 6448110 TR 644 S 120V 4003468644065 22 6449203 TR 644 S KX 4003468644188 204 6449204 TR 644 S DCF KX 4003468644195 204 Article number Type EA/GTI number Page 6489201 TR 648 S DCF KX 4003468648018 204 6490104 EM 4 top2 4003468649008 20 6490900 EM A top2 4003468649015 20 6850012 TR 685/2 top 4003468685136 26 7010001 RAMSES 701 4003468701140 154 7020001 RAMSES 702 4003468702055 154 7030001 RAMSES 703 4003468703052 154 7040001 RAMSES 704 4003468704028 154 7050001 RAMSES 705 4003468705032 154 7060001 RAMSES 706 4003468706022 154 7070001 RAMSES 707 4003468707029 154 7080001 RAMSES 708 4003468708026 154 7090001 RAMSES 709 4003468709030 154 7129200 RAMSES 712 KX 4003468712009 183 7139201 RAMSES 713 S KX 4003468713013 182 7139202 RAMSES 713 FC KX 4003468713020 188 7140002 RAMSES 714 4003468714126 158 7140016 RAMSES 714 A 4003468714133 158 7140017 RAMSES 714 A/FH 4003468714270 158 7150002 SOTHIS 715 4003468715024 164 7160101 AMU 716 R 4003468716250 162 7169101 AMU 716 USB 4003468716106 162 7169200 AMU 716 KX 4003468716205 187 7210030 RAMSES 721 4003468721018 150 7220030 RAMSES 722 4003468722015 150 7220801 RAMSES 722 S 4003468722022 148 7250030 RAMSES 725 4003468725016 150 7319200 CHEOPS drive KX 4003468731000 186 7329201 CHEOPS control KX 4003468732014 186 7410130 RAMSES 741 4003468741023 156 7410131 RAMSES 741 RA 4003468741030 156 7460130 RAMSES 746 4003468746028 156 7460131 RAMSES 746 RA 4003468746035 156 7480130 RAMSES 748 4003468748022 156 7480131 RAMSES 748 RA 4003468748039 156 7510131 RAMSES 751 RA 4003468751008 158 7709200 RAMSES 770 KX 4003468770009 181 7820030 RAMSES 782 4003468782019 150 7820801 RAMSES 782 S 4003468782026 148 7840030 RAMSES 784 4003468784013 150 7840801 RAMSES 784 S 4003468784020 148 8119132 RAMSES 811 top2 4003468811139 136 8120132 RAMSES 812 top2 4003468812037 138 8139501 RAMSES 813 top2 HF Set 1 4003468813218 140 8139503 RAMSES 813 top2 HF Set A 4003468813164 140 8139505 RAMSES 813 top2 HF Set S 4003468813188 140 8249200 VARIA 824 KX 4003468824009 180 8269200 VARIA 826 KX 4003468826003 180 8269201 VARIA 826 KX 4003468826010 180 8319132 RAMSES 831 top2 4003468831052 136 8320132 RAMSES 832 top2 4003468832035 138 8339501 RAMSES 833 top2 HF Set 1 4003468833049 142 8339502 RAMSES 833 top2 HF Set 2 4003468833056 142 8559132 RAMSES 855 top2 OT 4003468855010 144 9070001 Front panel kit 4003468900109 228 9070008 Surface-mounted light sensor 4003468900574 235 9070011 Analogue ush-mounted light sensor 4003468900604 236 9070041 Cover 55 x 55 for BZ 4003468902004 231 9070042 Plug-in socket BZ 4003468900697 231 246

Index 2010/2011 9070043 9079330 Article number Type EA/GTI number Page 9070043 Clamp BZ 4003468900703 231 9070049 Wall mounting kit 70 mm 4003468900727 230 9070050 Wall mounting kit 52,5 mm 4003468900734 230 9070053 Wall mounting kit 105 mm 4003468902363 231 9070061 Terminal cover 52,5 mm 4003468900802 228 9070064 Wall mounting kit 35 mm 4003468900826 230 9070065 Wall mounting kit 17,5 mm 4003468900833 230 9070071 Snap-on mounting 72 x 72 4003468900895 229 9070074 Cover 72 x 72 for BZ 4003468900925 231 9070075 Front-kit BZ 142-3 4003468900932 231 9070165 Memory card OBEISK 4003468901656 230 9070182 Power unit DCF77 4003468901694 229 9070191 External temperature sensor 1 4003468901915 237 9070192 External temperature sensor 2 4003468901922 237 9070212 Adapter plate RAMSES 714 4003468900796 236 9070223 Memory card OBEISK KX 16 K 4003468902417 229 9070230 OBEISK PC set 4003468903001 229 9070243 Antenna DCF77 4003468900512 228 9070245 Adapter RAMSES 72x/78x 4003468902059 236 9070247 Flush-mounted light sensor UA KX 4003468902882 236 9070251 Programming software PHARAO 4003468902844 239 9070252 Programming cable PHARAO 4003468902851 239 9070271 Antenna DCF77 KX 4003468903056 228 9070305 OBEISK KX PC set 4003468903070 229 9070320 Memory card OBEISK KX 64 K 4003468903315 230 9070321 Temperature sensor 4003468903360 237 9070328 Memory module PHARAO-II 4003468903414 239 9070329 GSM cable PHARAO-II 4003468903483 239 9070334 Antenna RAMES 813/833 4003468909447 237 9070364 Power supply KX 640 ma 4003468903582 208 9070367 Diode module UXOR 4003468903605 239 9070371 Flow temperature sensor 4003468903629 237 9070379 Plunge sensor RAMSES 4003468903711 238 9070380 Mast mounting weather station 4003468903742 239 9070396 GSM modem 4003468903407 237 9070397 Interface USB KX 4003468903995 209 9070398 ine coupler KX 4003468904008 209 9070404 Memory card OBEISK top2 4003468904053 230 9070409 OBEISK top2 PC set 4003468904015 229 9070410 Antenna top2 RC-DCF 4003468904077 228 9070415 Digital surface-mounted light sensor 4003468904268 236 9070416 Analogue surface-mounted light sensor 4003468904275 236 9070427 OT-Center RAMSES 4003468904497 237 9070436 Valve adapter VA 78 4003468904220 238 9070437 Valve adapter VA 80 4003468904237 238 9070438 Actuator APHA 4 230 V 4003468904244 238 9070439 Actuator APHA 4 24 V 4003468904251 238 9070456 Digital ush-mounted light sensor 4003468904343 236 9070459 External temperature sensor IP 65 4003468903810 237 9070480 Adapter plate RAMSES 70x 4003468904299 236 9070486 UA star adpater plate 4003468907559 235 Article number Type EA/GTI number Page 9070494 Power unit CO2 sensor 4003468904534 236 9070511 Surface frame ECO-IR 180 7612748000735 231 9070512 Surface frame ECO-IR 360 7612748000728 232 9070513 Surface frame Presenceight 7612748001145 232 9070514 Surface frame compact 7612748000711 232 9070515 clic 7612748000919 233 9070516 QuickFix square cover 7612748000575 233 9070517 QuickFix circular cover 7612748000568 233 9070518 QuickFix concrete square cover 7612748000971 232 9070519 QuickFix concrete circular cover 7612748000964 232 9070521 QuickFix concrete ush-mount box 7612748000742 233 9070522 QuickFix concrete ush-mount housing 7612748000551 233 9070523 RC lter 7612748001701 232 9070524 Bus coupling unit KX 7612748000629 232 9070531 QuickSafe 7612748000582 233 9070532 QuickSet plus 7612748000926 234 9070535 SPHIX corner angle 4003468904398 234 9070536 SPHIX RC 104 Pro 4003468904404 235 9070537 SPHIX RC 105 Pro 4003468904411 235 9070538 SPHIX RC 104 4003468904428 235 9070539 SPHIX RC 105 4003468904435 235 9070601 Central part RAMSES 746 4003468904572 239 9070602 Central part RAMSES 741/748 4003468904589 238 9070603 Frame RAMSES 74x 4003468904596 238 9070605 Socket RAMSES 4003468904657 238 9070610 Antenna top2 RC-GPS 4003468903254 228 9070625 UXA corner angle black 4003468909522 234 9070626 UXA corner angle white 4003468909515 234 9070675 SendoPro 868-A 7612748002524 234 9070689 Junction casing 115 x 115 x 100 mm 7612748002661 233 9070690 SendoClic 7612748002678 234 9070699 Power supply KX 320 ma 4003468904541 208 9070701 Power supply KX 160 ma 4003468904558 208 9070892 Power unit top2 GPS 4003468904718 229 9079330 Power unit 24 V DC 4003468903520 239 247

Discontinued models 2009/2010 Theben device type Art.o. Theben device type Art.o. Discontinued models Successors SUD 228 (8 h) 2280575 SUD 228 II 2280577 SUD 228 (9 h) 2280576 SUD 228 II 2280577 PHARAO-II Upgrade 4ED 5759100 no successor RAMSES 742 7420130 no successor RAMSES 742 RA 7420131 no successor RAMSES 811 top 8119032 RAMSES 811 top2 8119132 RAMSES 812 top 8120032 RAMSES 812 top2 8120132 RAMSES 813 top HF Set 1 8139401 RAMSES 813 top2 HF Set 1 8139501 RAMSES 813 top HF Set 2 8139402 RAMSES 833 top2 HF Set 2 8339502 RAMSES 813 top HF Set A 8139403 RAMSES 813 top2 HF Set A 8139503 RAMSES 813 top HF Set 4 8139404 2 x RAMSES 833 top2 HF Set 2 2 x 8339502 RAMSES 813 top HF Set S 8139405 RAMSES 813 top2 HF Set S 8139505 RAMSES 816 top 8169032 RAMSES 855 top2, depending on application also RAMSES 832 top2 possible 8559132, 8320132 RAMSES 817 top 8179032 RAMSES 855 top2, depending on application also RAMSES 832 top2 possible 8559132, 8320132 RAMSES 818 top 6 A 8180035 RAMSES 832 top2 + Floor sensor 8320132 + 9070321 RAMSES 818 top 16 A 8180036 RAMSES 832 top2 (Attention: only 6 A load instead of 16 A) + Floor sensor 8320132 + 9070321 RAMSES 831 top 8319032 RAMSES 831 top2 8319132 RAMSES 832 top 8320032 RAMSES 832 top2 8320132 RAMSES 855 top 8559032 RAMSES 855 top2 OT 8559132 RAMSES 855 top + OT-Center 8559901 RAMSES 855 top2 OT + RAMSES OT-Center 8559132 + 9070427 Cover (RAMSES 7..) 9384263 no successor TM 171 h 1710008 SY 151 h 1510011 SY 161 h 1610008, 1610802 SY 161 d 1610011 SU 181 h 1810008, 1810802, SU 181 d 1810011 1810842 MEM 198 h 1980008 SU 191 w 1910011 SY 168 h 1680008 SY 161 d 1610011 TM 178 h 1780008 SY 151 h 1510011 SU 188 h 1880008 SU 181 d 1810011 TR 641 S 6410001 TR 641 top2 6410100 TR 642 S 6420001 TR 642 top2 6420100 TR 644 S 6440001 TR 644 top2 6440100 TR 641 S DCF 6410301 TR 641 top2 RC 6410300 TR 642 S DCF 6420301 TR 642 top2 RC 6420300 TR 644 S DCF 6440301 TR 644 top2 RC 6440300 TR 685/2 top 6850012 TR 685-2 top2 6850102 DMG 2 KX 4910220 DMG 2 S KX 4910270 DME 2 KX 4910221 DME 2 S KX 4910271 DMB 2 KX 4910222 DMB 2 S KX 4910272 SMG 2 KX 4910223 SMG 2 S KX 4910273 SME 2 KX 4910224 SME 2 S KX 4910274 Power supply 320 ma 9070374 Power supply 320 ma 9070699 SEEKTA 173 DCF 1730001 TR 642 top2 RC 6420100 TR 610 top 24V 9070374 TR 610 top2 24V 6104100 TR 612 top 24V 9070374 TR 612 top2 24V 6124100 15 248

Theben AG Your specialist partner Explanation of de nitions REDUCED TEMPERATURE Reduced room temperature during the night or when unoccupied, saves energy. Recommended temperature e. g. 16 C. COECTIO TYPE Contact type for connecting cables to device. ADJUSTABE OPERATIG POIT AD THERMA CIRCUATIO If room thermostats are unfavourably located, e. g. on external walls, the device operating point can be changed. Thermal circulation prevents rooms overheating. Adjustments can be made for especially fast or slow reacting heating systems. WORKIG VOTAGE ominal voltage required for operating device. Safe operation is guaranteed in in a tolerance range of ± 10%. POWER COSUMPTIO Power draw required to operate device without switching capacity. SUPPRESSIO MEASURES Despite internal safety measures, unusually strong interference elds can exceptionally interfere with microprocessorcontrolled timers. Interference can be prevented by taking the following actions during installation: Avoid installing in the immediate vicinity of inductive consumers. ay separate mains connections and use line lters if necessary Shield inductive consumer with Varistor or RC link. FROST PROTECTIO Operating mode for room thermostats for protecting the heating and water system from frost damage, e. g. +8 C. POWER RESERVE In the event of power loss, the timer continues to run for the duration of the power reserve thanks to a built-in power reserve. This removes the need to reset the timer. The power reserve details refer to the new condition and 20 C ambient temperature. The power reserve does however diminish in relation to service life and temperature. MAUA SWITCH Priority switch switches output to "Permanent O", "Permanent OFF" or to "Auto" for automatic time control. "Perm" means manual permanent switching of mechanical timers. CHAES umber of switching outputs/inputs for timers, twilight switches, controls and actuators. PROGRESS DISPAY Visual function check for mechanical timers. AMP OADS Energy saving lamps as well as sodium and mercury vapour lamps place a particular stress on the output contacts through high switch-on peaks. In isolated cases check whether a cutoff relay or cutout is required. FU POWER RESERVE If the power reserve is provided by a rechargeable battery then the power reserve is only fully available after a certain charging time. COTACT OPEIG WIDTH With switching contacts a distinction is made between a 3 mm greater or lesser contact distance. PROGRAM Time-related operational sequence dependent on preset commands. PUSE WIDTH MODUATIO OR HYSTERESIS COTROER Thermostat with pulse width modulation clock cyclically and have varied switching periods. The cycle is adjustable. Hysteresis controllers switch on if the set hysteresis temperature range is exceeded or not achieved. SWITCHIG CAPACITY is the maximum permissible loading of the switching contacts in amperes at the nominal voltage with resistive load. The details in brackets indicate the permissible inductive load at cos ϕ 0.6 (e. g. motor load). The AX supplement indicates the permissible uorescent lamp load. SWITCHIG PRE-SEECTIO Time limited manual change to switching period by anticipating the next switching command. E. g. OFF is manually changed to O until the next successive OFF command in the time program. The automatic time program then resumes. PROTECTIO CASS Devices in Germany have to meet various protection classes to satisfy requirements against accidentally touching live components and against too high non-contact voltage. Protection class I: All metal parts that can be touched during operation or maintenance must be connected to the earth conductor. Protection class II: The devices are double or triple insulated and do not have an earth connection. Protection class III: The devices are designed to be used with safety extra-low voltage and have neither internal nor external power circuits working on other voltages. MEMORY OCATIOS They are designed to store switching times made up of information on the day of week (if necessary date) switching time and switching status. EEPROM memory is not temporary storage and retains the information even without power supply for up to 10 years. 3 OR 4 WIRE SWITCHIG With staircase light timers the 3 or 4 wire riser can be used for keys or lights from oor to oor. PERMISSIBE AMBIET TEMPERATURE Temperature range that the device can function reliably in, e. g. constant ambient temperature. COUTIG RAGE Maximum number of operating hours that can be directly read. SEV (SAFETY EXTRA-OW VOTAGE) Voltage that does not exceed 42 V between the wires or between the wires and the earth where the idling voltage does not exceed 50 V. If SEV is taken from the mains supply then this must achieved via a safety transformer or a converter with separate winding with insulation that meets the requirements of double or increased insulation. PEV (PROTECTIVE EXTRA-OW VOTAGE) An earthed electric circuit operated with SEV which is separated from other circuits by basic insulation and protective sheathing, double insulation or increased insulation. Impressum Client: Theben AG, Haigerloch Advertising Manager: Klaus Tielmann Productdatabase Manager: Arne Mohl Realisation: Theben AG, Haigerloch Design by: Theben AG Sources of pictures: Studio Majer, Theben AG Print: edigor Druck und Medien GmbH 15 249

Your specialist partner General conditions Theben AG General conditions for the supply of products and services of the electrical and electronics industry ( G )* for commercial transactions between businesses I. General provisions 1. egal relations between Supplier and Purchaser in connection with supplies and/or services of the Supplier (hereinafter referred to as Supplies ) shall be solely governed by the present G. The Purchaser s general terms and conditions shall apply only if expressly accepted by the Supplier in writing. The scope of delivery shall be determined by the congruent mutual written declarations. 2. The Supplier herewith reserves any industrial property rights and/or copyrights pertaining to its cost estimates, drawings and other documents (hereinafter referred to as Documents ). The Documents shall not be made accessible to third parties without the Supplier s prior consent and shall, upon request, be returned without undue delay to the Supplier if the contract is not awarded to the Supplier. Sentences 1 and 2 shall apply mutatis mutandis to the Purchaser s Documents; these may, however, be made accessible to those third parties to whom the Supplier has rightfully subcontracted Supplies. 3. The Purchaser has the non-exclusive right to use standard software and rmware, provided that it remains unchanged, is used within the agreed performance parameters, and on the agreed equipment. Without express agreement the Purchaser may make one back-up copy of standard software. 4. Partial deliveries are allowed, unless they are unreasonable to accept for the Purchaser. 5. The term claim for damages used in the present G also includes claims for indemni cation for useless expenditure. statutory provisions providing that a remedy period is not needed shall be unaffected. The Purchaser shall be obliged to return the Retained Goods. The fact that the Supplier takes back Retained Goods and/or exercises the retention of title, or has the Retained Goods seized, shall not be construed to constitute a rescission of the contract, unless the Supplier so expressly declares. IV. Time for supplies; delay 1. Times set for Supplies shall only be binding if all Documents to be furnished by the Purchaser, necessary permits and approvals, especially concerning plans, are received in time and if agreed terms of payment and other obligations of the Purchaser are ful lled. If these conditions are not ful lled in time, times set shall be extended reasonably; this shall not apply if the Supplier is responsible for the delay. 2. If non-observance of the times set is due to force majeure such as mobilization, war, rebellion or similar events, e. g. strike or lockout, such time shall be extended accordingly. The same shall apply if the Supplier does not receive its own supplies in due time or in due form. 3. If the Supplier is responsible for the delay (hereinafter referred to as Delay ) and the Purchaser has demonstrably suffered a loss therefrom, the Purchaser may claim a compensation as liquidated damages of 0.5 % for every completed week of Delay, but in no case more than a total of 5 % of the price of that part of the Supplies which due to the Delay could not be put to the intended use. 2. The risk shall pass to the Purchaser if dispatch, delivery, the start or performance of assembly or erection, the taking over in the Purchaser s own works, or the trial run is delayed for reasons for which the Purchaser is responsible or if the Purchaser has otherwise failed to accept the Supplies. VI. Assembly and erection Unless otherwise agreed in written form, assembly and erection shall be subject to the following provisions: 1. The Purchaser shall provide at its own expense and in due time: a) all earth and construction work and other ancillary work outside the Supplier s scope, including the necessary skilled and unskilled labor, construction materials and tools, b) the equipment and materials necessary for assembly and commissioning such as scaffolds, lifting equipment and other devices as well as fuels and lubricants, c) energy and water at the point of use including connections, heating and lighting, d) suitable dry and lockable rooms of suf cient size adjacent to the site for the storage of machine parts, apparatus, materials, tools, etc. and adequate working and recreation rooms for the erection personnel, including sanitary facilities as are appropriate in the speci c circumstances; furthermore, the Purchaser shall take all measures it would take for the protection of its own possessions to protect the possessions of the Supplier and of the erection personnel at the site, e) protective clothing and protective devices needed due to particular conditions prevailing on the speci c site. 2. Before the erection work starts, the Purchaser shall unsolicitedly make available any information required concerning the location of concealed electric power, gas and water lines or of similar installations as well as the necessary structural data. 3. Prior to assembly or erection, the materials and equipment necessary for the work to start must be available on the site of assembly or erection and any preparatory work must have advanced to such a degree that assembly or erection can be started as agreed and carried out without interruption. Access roads and the site of assembly or erection must be level and clear. 4. If assembly, erection or commissioning is delayed due to circumstances for which the Supplier is not responsible, the Purchaser shall bear the reasonable costs incurred for idle times and any additional traveling expenditure of the Supplier or the erection personnel. 5. The Purchaser shall attest to the hours worked by the erection personnel towards the Supplier at weekly intervals and the Purchaser shall immediately con rm in written form if assembly, erection or commissioning has been completed. 6. If, after completion, the Supplier demands acceptance of the Supplies, the Purchaser shall comply therewith within a period of two weeks. In default thereof, acceptance is deemed to have taken place. Acceptance is also deemed to have been effected if the Supplies are put to use, after completion of an agreed test phase, if any. 15 II. Prices, terms of payment, and set-off 1. Prices are ex works and excluding packaging; value added tax shall be added at the then applicable rate. 2. If the Supplier is also responsible for assembly or erection and unless otherwise agreed, the Purchaser shall pay the agreed remuneration and any incidental costs required, e. g. for traveling and transport as well as allowances. 3. Payments shall be made free Supplier s paying of ce. 4. The Purchaser may set off only those claims which are undisputed or nonappealable. III. Retention of title 1. The items pertaining to the Supplies ( Retained Goods ) shall remain the Supplier s property until each and every claim the Supplier has against the Purchaser on account of the business relationship has been ful lled. If the combined value of the Supplier s security interests exceeds the value of all secured claims by more than 10 %, the Supplier shall release a corresponding part of the security interest if so requested by the Purchaser; the Supplier shall be entitled to choose which security interest it wishes to release. 2. For the duration of the retention of title, the Purchaser may not pledge the Retained Goods or use them as security, and resale shall be possible only for resellers in the ordinary course of their business and only on condition that the reseller receives payment from its customer or makes the transfer of property to the customer dependent upon the customer ful lling its obligation to effect payment. 3. The Purchaser shall inform the Supplier forthwith of any seizure or other act of intervention by third parties. 4. Where the Purchaser fails to ful l its duties, fails to make payment due, or otherwise violates its obligations the Supplier shall be entitled to rescind the contract and take back the Retained Goods in the case of continued failure following expiry of a reasonable remedy period set by the Supplier; the 4. Purchaser s claims for damages due to delayed Supplies as well as claims for damages in lieu of performance exceeding the limits speci ed in o. 3 above are excluded in all cases of delayed Supplies, even upon expiry of a time set to the Supplier to effect the Supplies. This shall not apply in cases of mandatory liability based on intent, gross negligence, or due to loss of life, bodily injury or damage to health. Rescission of the contract by the Purchaser based on statute is limited to cases where the Supplier is responsible for the delay. The above provisions do not imply a change in the burden of proof to the detriment of the Purchaser. 5. At the Supplier s request, the Purchaser shall declare within a reasonable period of time whether it, due to the delayed Supplies, rescinds the contract or insists on the delivery of the Supplies. 6. If dispatch or delivery, due to Purchaser s request, is delayed by more than one month after noti cation of the readiness for dispatch was given, the Purchaser may be charged, for every additional month commenced, storage costs of 0.5 % of the price of the items of the Supplies, but in no case more than a total of 5 %. The parties to the contract may prove that higher or, as the case may be, lower storage costs have been incurred. V. Passing of risk 1. Even where delivery has been agreed freight free, the risk shall pass to the Purchaser as follows: a) if the Supplies do not include assembly or erection, at the time when the Supplies are shipped or picked up by the carrier. Upon the Purchaser s request, the Supplier shall insure the Supplies against the usual risks of transport at the Purchaser s expense; b) if the Supplies include assembly or erection, at the day of taking over in the Purchaser s own works or, if so agreed, after a fault-free trial run. VII. Receiving supplies The Purchaser shall not refuse to receive Supplies due to minor defects. 250

Theben AG Your specialist partner General conditions VIII. Defects as to quality The Supplier shall be liable for defects as to quality ( Sachmängel, hereinafter referred to as Defects,) as follows: 1. Defective parts or defective services shall be, at the Supplier s discretion, repaired, replaced or provided again free of charge, provided that the reason for the Defect had already existed at the time when the risk passed. 2. Claims for repair or replacement are subject to a statute of limitations of 12 months calculated from the start of the statutory statute of limitations; the same shall apply mutatis mutandis in the case of rescission and reduction. This shall not apply where longer periods are prescribed by law according to Sec. 438 para. 1 o. 2 (buildings and things used for a building), Sec. 479 para. 1 (right of recourse), and Sec. 634a para. 1 o. 2 (defects of a building) German Civil Code ( BGB ), in the case of intent, fraudulent concealment of the Defect or non-compliance with guaranteed characteristics (Beschaffenheitsgarantie). The legal provisions regarding suspension of the statute of limitations ( Ablaufhemmung, Hemmung ) and recommencement of limitation periods shall be unaffected. 3. oti cations of Defect by the Purchaser shall be given in written form without undue delay. 4. In the case of noti cation of a Defect, the Purchaser may withhold payments to an amount that is in a reasonable proportion to the Defect. The Purchaser, however, may withhold payments only if the subject-matter of the noti cation of the Defect involved is justi ed and incontestable. The Purchaser has no right to withhold payments to the extent that its claim of a Defect is time-barred. Unjusti ed noti cations of Defect shall entitle the Supplier to demand reimbursement of its expenses by the Purchaser. 5. The Supplier shall be given the opportunity to repair or to replace the defective good ( acherfüllung ) within a reasonable period of time. 6. If repair or replacement is unsuccessful, the Purchaser is entitled to rescind the contract or reduce the remuneration; any claims for damages the Purchaser may have according to o. 10 shall be unaffected. 7. There shall be no claims based on Defect in cases of insigni cant deviations from the agreed quality, of only minor impairment of usability, of natural wear and tear, or damage arising after the passing of risk from faulty or negligent handling, excessive strain, unsuitable equipment, defective civil works, inappropriate foundation soil, or claims based on particular external in uences not assumed under the contract, or from non-reproducible software errors. Claims based on defects attributable to improper modi cations or repair work carried out by the Purchaser or third parties and the consequences thereof are likewise excluded. 8. The Purchaser shall have no claim with respect to expenses incurred in the course of supplementary performance, including costs of travel, transport, labor, and material, to the extent that expenses are increased because the subjectmatter of the Supplies has subsequently been brought to another location than the Purchaser s branch of ce, unless doing so complies with the normal use of the Supplies. 9. The Purchaser s right of recourse against the Supplier pursuant to Sec. 478 BGB is limited to cases where the Purchaser has not concluded an agreement with its customers exceeding the scope of the statutory provisions governing claims based on Defects. Moreover, o. 8 above shall apply mutatis mutandis to the scope of the right of recourse the Purchaser has against the Supplier pursuant to Sec. 478 para. 2 BGB. 10. The Purchaser shall have no claim for damages based on Defects. This shall not apply to the extent that a Defect has been fraudulently concealed, the guaranteed characteristics are not complied with, in the case of loss of life, bodily injury or damage to health, restrictions to liberty and/or intentionally or grossly negligent breach of contract on the part of the Supplier. The above provisions do not imply a change in the burden of proof to the detriment of the Purchaser. Any other or additional claims of the Purchaser exceeding the claims provided for in this Article VIII, based on a Defect, are excluded. IX. Indusrial property rights and copyright; defects in title 1. Unless otherwise agreed, the Supplier shall provide the Supplies free from third parties industrial property rights and copyrights (hereinafter referred to as IPR ) with respect to the country of the place of delivery only. If a third party asserts a justi ed claim against the Purchaser based on an infringement of an IPR by the Supplies made by the Supplier and used in conformity with the contract, the Supplier shall be liable to the Purchaser within the time period stipulated in Article VIII o. 2 as follows: a) The Supplier shall choose whether to acquire, at its own expense, the right to use the IPR with respect to the Supplies concerned or whether to modify the Supplies such that they no longer infringe the IPR or replace them. If this would be impossible for the Supplier under reasonable conditions, the Purchaser may rescind the contract or reduce the remuneration pursuant to the applicable statutory provisions. b) The Supplier s liability to pay damages is governed by Article XI. c) The above obligations of the Supplier shall apply only if the Purchaser (i) immediately noti es the Supplier of any such claim asserted by the third party in written form, (ii) does not concede the existence of an infringement and (iii) leaves any protective measures and settlement negotiations to the Supplier s discretion. If the Purchaser stops using the Supplies in order to reduce the damage or for other good reason, it shall be obliged to point out to the third party that no acknowledgement of the alleged infringement may be inferred from the fact that the use has been discontinued. 2. Claims of the Purchaser shall be excluded if it is responsible for the infringement of an IPR. 3. Claims of the Purchaser are also excluded if the infringement of the IPR is caused by speci cations made by the Purchaser, by a type of use not foreseeable by the Supplier or by the Supplies being modi ed by the Purchaser or being used together with products not provided by the Supplier. 4. In addition, with respect to claims by the Purchaser pursuant to o. 1 a) above, Article VIII os. 4, 5, and 9 shall apply mutatis mutandis in the event of an infringement of an IPR. 5. Where other defects in title occur, Article VIII shall apply mutatis mutandis. 6. Any other claims of the Purchaser against the Supplier or its agents or any such claims exceeding the claims provided for in this Article IX, based on a defect in title, are excluded. X. Impossiblity of performance; adaption of contract 1. To the extent that delivery is impossible, the Purchaser is entitled to claim damages, unless the Supplier is not responsible for the impossibility. The Purchaser s claim for damages is, however, limited to an amount of 10 % of the value of as of June 2005 the part of the Supplies which, owing to the impossibility, cannot be put to the intended use. This limitation shall not apply in the case of mandatory liability based on intent, gross negligence or loss of life, bodily injury or damage to health; this does not imply a change in the burden of proof to the detriment of the Purchaser. The Purchaser s right to rescind the contract shall be unaffected. 2. Where unforeseeable events within the meaning of Article IV o. 2 substantially change the economic importance or the contents of the Supplies or considerably affect the Supplier s business, the contract shall be adapted taking into account the principles of reasonableness and good faith. To the extent this is not justi able for economic reasons, the Supplier shall have the right to rescind the contract. If the Supplier intends to exercise its right to rescind the contract, it shall notify the Purchaser thereof without undue delay after having realized the repercussions of the event; this shall also apply even where an extension of the delivery period has previously been agreed with the Purchaser. XI. Other claims for damages; statute of limitations 1. The Purchaser has no claim for damages based on whatever legal reason, including infringement of duties arising in connection with the contract or tort. 2. The above shall not apply in the case of mandatory liability, e. g. under the German Product iability Act ( Produkthaftungsgesetz ), in the case of intent, gross negligence, loss of life, bodily injury or damage to health, or breach of a condition which goes to the root of the contract ( wesentliche Vertragsp ichten ). However, claims for damages arising from a breach of a condition which goes to the root of the contract shall be limited to the foreseeable damage which is intrinsic to the contract, unless caused by intent or gross negligence or based on liability for loss of life, bodily injury or damage to health. The above provision does not imply a change in the burden of proof to the detriment of the Purchaser. 3. To the extent that the Purchaser has a claim for damages, it shall be timebarred upon expiration of the statute of limitations pursuant to Article VIII o. 2. The same shall apply to the Purchauser s claims in connection with actions undertaken to avoid any damage (e. g. callback). In the case of claims for damages under the German Product iability Act, the statutory statute of limitations shall apply. XII. Venue and applicable law 1. If the Purchaser is a businessman, sole venue for all disputes arising directly or indirectly out of the contract shall be the Supplier s place of business. However, the Supplier may also bring an action at the Purchaser s place of business. 2. egal relations existing in connection with this contract shall be governed by German substantive law, to the exclusion of the United ations Convention on contracts for the International Sale of Goods (CISG). XIII. Severability clause The legal invalidity of one or more provisions of this Agreement in no way affects the validity of the remaining provisions. This shall not apply if it would be unreasonable for one of the parties to be obligated to continue the contract. 15 251

Theben AG worlwide Group companies Agencies Theben AG 15 HEADQUARTERS Theben AG Hohenbergstr. 32 D-72401 Haigerloch Postfach 56 D-72394 Haigerloch Phone +49 74 74/6 92-0 Fax +49 74 74/6 92-15 0 info@theben.de www.theben.de THEBE GROUP COMPAIES Timeguard td Victory Park 400 Edgeware Road ondon W2 6D Phone +44 208 4508944 Fax +44 208 4525143 csc@timeguard.com www.timeguard.com THEBE S.A.R.. Zone Industrielle des Vignes 32 38 rue Bernard 93012 Bobigny cédex Phone +33 1 49159700 Fax +33 1 48445761 theben@theben.fr www.theben.fr Theben HTS AG Im anghag 11 8307 Effretikon Phone +41 52 355 1700 Fax +41 52 355 1701 info@theben-hts.ch www.theben-hts.ch THEBE S.R.. Via Simone de Gatti, 3 20091 Bresso Phone +39 02 66505083 Fax +39 02 66505397 info@theben.it www.theben.it Theben AG Jewelry Trade Center 919/341 Floor 27 (Building o. 1, orth) Silom Road, Silom Bangrak 10500 Bangkok Thailand Phone +66 2 63 00 530 Fax +66 2 63 00 540 Mobil +66 81 700 2500 bernd.dluzak@theben-asia.com www.theben.de WORDWIDE AGECIES ARGETIA HERTIG SA. Bolivar 1335 C1141AAD Ciudad de Buenos Aires Phone +54-11-43617136 Fax +54-11-43003372 ventas@hertig.com.ar www.hertig.com.ar AUSTRAIA OMEGA POWER EQUIPMET P/ 47 Bennet Street Dandenong Victoria 3175 Phone +61 3 9793 6111 Fax +61 3 9792 4509 sales@omega.com.au www.omegapower.com.au AUSTRIA SIBIK EEKTRIK GmbH & CO. KG Murbangasse 6 1100 Wien Phone +43 1 680060 Fax +43 1 68006543 info@siblik.com www.siblik.at BEGIUM TEMPOEC SA. 49, Route de Biesme 6530 Thuin Phone +32 71 590039 Fax +32 71 590161 info@tempolec.be www.tempolec.be BUGARIA SEO SOFIA TD. 26, ikolay Palauzov St. 5300 Gabrovo Phone +359 66 80 00 71 Fax +359 66 80 00 72 seno@senoso a.com www.senoso a.com CAADA DAVIS COTROS IMITED 2200 Bristol Circle Oakville Ontario 6H 5R3 Phone +1 905 8292000 Fax +1 905 8292630 info@daviscontrols.com www.daviscontrols.com CHIE SCHARFSTEI SA Av. Sta. Maria 0510 Providencia, Santiago Phone +56 2 550 0000 Fax +56 2 550 1000 scharfstein@scharfstein.cl www.scharfstein.cl CHIA/HOG KOG JEBSE & CO. TD. China Trade Division 30/F. ee Gardens Two 28 Yun Pin Road HK Causeway Bay Phone +852 2923 8765 Fax +852 2882 2017 raymondchiu@jebsen.com www.jebsen.com CYPRUS PAMBOS ICOAOU & SO TD. 38 Strovolos Street Tseri 2480 icosia Phone +35 22 38 03 77 Fax +35 22 38 33 68 nicha@cytanet.com.cy CZECH REPUBIC EEKTRO SYSTEM TECHIK spol. s.r.o. Pod Pekarnami 338/12 19000 Praha 9 Vysocany Phone +420 266 090711 Fax +420 266 090717 est@est-praha.cz www.est-praha.cz DEMARK GYCOM DAMARK A/S Theilgaards Torv 1 4600 Køge Phone +45 56 26 66 35 Fax +45 56 26 77 78 sales.dk@gycom.com www.gycom.com EGYPT MOUADECO EGIEERIG & TRADIG CO 241, El Hegaz Street Flat 8 Heliopolis, Cairo Phone +20 2 2451631 Fax +20 2 6383497 mounadelco@hotmail.com ESTOIA VAI BATIC AS Mäepealse 2 12618 Tallinn Phone +372 6593200 Fax +372 6593201 info@vallin.ee www.vallinbaltic.com FIAD GYCOM FIAD OY P.O. Box 62 Pakkalantie 30 A 1531 Vantaa Phone +358 9 25252100 Fax +358 9 25252177 etunimi.sukunimi@gycom.com www.gycom.com GREECE COSTATACATOS BROTHERS SA. 17 Km Ethnikis Athinon amias 145-64 Ki ssia Phone +30 210 6252001 Fax +30 210 6252012 sales@akbros.gr www.akbros.gr HUGARY KAMEITHER KFT Budapest Rákóczi Ferenc tu 189 1214 Budapest Phone +36 1 4253288 Fax +36 1 4253288 info@theben.hu www.theben.hu Elektropro Kereskedelmi KFT Albertirsai ut 3 1101 Budapest Phone +36 1 4606140 Fax +36 1 4606141 info@elektropro.hu www.elektropro.hu ICEAD REYKJAFE TD. Skipholti 35 105 Reykjavik Phone +354 1 5886010 Fax +354 1 5886088 reykjafell@reykjafell.is www.reykjafell.is IDIA IDO ASIA MARKETIG TD. B 200 Phase II oida 201 305 U. P Phone +91 120 304 2222 Fax +91 120 256 3442 sales@indoasian.com www.indoasian.com IDOESIA P. T. GUA ERA DISTRIBUSI Jl Rawa Gelam II o. 8 Jakarta Timur 13930 Phone +62 21 46825050 Fax +62 21 46824758 C-Service@GED-GAE.co.id www.gae.co.id IRA S.G. RIAZI TRADIG P.O. Box 14185/599 o. 4, Bld. 12, Parastoo St., Valiasr Ave. Tehran Phone +98 21 88890340 Fax +98 21 88918159 info@sgrtrading.net www.sgrtrading.net IREAD PEW GROUP Unit 6 orthwest Business Park Blanchardstown, Dublin 15 Phone +353 1 8610040 Fax +353 1 8853998 info@pewl.ie www.pewl.ie ISRAE GAOZ EECTROICS TD. P. O. Box 35 Rosh Ha ayin 40850 Galoz Building 15, Hameretz Street Rosh Ha ayin 48017 Phone +972 3 9023456 Fax +972 3 9021990 sales@galoz.co.il www.galoz.co.il JORDA OOR AA OOR EST. 214 Gardens Street Amman Phone +962 65561801 Fax +962 799668393 hothyfa@nooralanoor.net 252

Theben AG Theben AG worldwide Group companies Agencies KOREA MEC MAHAI EECTRIC Co., TD 792-7, Yeoksam-Dong, Kangnam-Gu, Seoul 135-080, Korea Phone +82 2 2194 3300 Fax +82 2 2194 3397 yskim@hanmec.co.kr www.hanmec.co.kr ORWAY GYCOM ORGE AS Gjerdums vei 16 0484 Oslo Phone +47 22 64 55 25 Fax +47 22 64 55 26 gycom.no@gycom.com www.gycom.com SERBIA SOBE D.O.O Miska Jovanovica 9 11000 Belgrad Phone +381 11 3087-507 Fax +381 11 3087-064 of ce@sobel.co.yu www.sobel.co.yu THAIAD TECHOOGY ISTRUMETS CO. TD 208/132-137 Pattanakarn Rd., Pravet, Bangkok 10250 Phone +662 722 2233 Fax +662 722 3047 ttic@inet.co.th www.tic.co.th EBAO EST. GARABED AYAIA & SOS P. O. Box 175-214 176 Gouraud Avenue Beirut Phone +961 1 447940 or 445096 Fax +961 1 582357 gasons@dm.net.lb ATVIA VAI BATIC SIA Maskavas str 322 1063 Riga Phone +371 6718 7204 Fax +371 6718 7205 info@vallin.lv www.vallinbaltic.com ITHUAIA VAI BATIC UAB Seimyniskiu str. 5A 09312 Vilnius Phone +370 5272 8893 Fax +370 5272 8843 info@vallin.lt www.vallinbaltic.com MAAYSIA EECTECH DISTRIBUTIO SYSTEMS SD. BHD. 16 1, Jalan 6/89 B, Kawasan Perindustrian Trisegi, Batu 3 1/2, Off Jalan Sungei Besi 57100 Kuala umpur Phone +60 3 7981 8950 Fax +60 3 7981 8953 info@edsm.com.my www.edsm.com.my MOTEEGRO Rarovac Komerc Podgorica Bracana Bracanovica 6 81000 Podgorica Phone +38 1 81609091 Fax +38 1 81609091 rarovackomerc@cg.yu MOROCCO GEERA TECHICS 22 Rue Rahal Ben Ahmed (Ex. Rue Dinant) Casablanca Phone +212 22 245877 Fax +212 22 243716 genetech@menara.ma ETHERADS DURICK B.V. Mijlweg 57 3316 BE Dordrecht Phone +31 78 617 84 19 Fax +31 78 618 25 94 durinck@durinck.nl www.durinck.nl OMA STARS IGHT..C. P.O. Box 2822 112 Ruwi Phone +968 697025 Fax +968 600217 starmail@omantel.net.om PHIIPPIES AVESCO MARKETIG CORPORATIO 810 Aurora Blvd., corner Yale St. 1109 Cubao, Quezon City Phone +63 2 9128881 Fax +63 2 9122911/9122999 avesco@avesco.bayandsl.ph www.avesco.com.ph POAD PPUH E-TEAM al. Mlodych 26 28 41-106 Siemianowice Phone +48 322 2043628 Fax +48 322 200005 el-team@el-team.com.pl www.el-team.com.pl PORTUGA D-DUARTE EVES,.DA Rua D do úcleo Empresarial de Venda do Pinheiro Quinta dos Estrangeiros, PAVIHAO 78 2665-601 Venda do Pinheiro Phone +351 219 668100 Fax +351 219 668109 info@duarteneves.pt www.duarteneves.pt RUSSIA MARBE Rizhsky passage 13 129626 Moscow Phone + 7 495 7379887 sales-msk@marbel.ru www.marbel.ru Bolshoi Sampsonievsky 32 194044 St. Petersburg Phone + 7 812 3242777 sales-spb@marbel.ru www.marbel.ru SAUDI ARABIA AWAR A-WESSAM EST. P. O. Box 23521 Gurabi Bin Shaihon Center Riyadh 11436 P.O. Box 23521 Phone +966 1 4055942 Fax +966 1 4051631 info@al-wessam.com www.al-wessam.com SIGAPORE ITE EECTRIC SYSTEMS CO PTE. TD. 1 Harrison Road #01-01, ITE Electric Building Singapore 369652 Phone +65 6 285 2233 Fax +65 6 284 3452 cseng@ite.com.sg www.ite.com.sg SOVEIA OKO tech d.o.o. Ul. Mileve Zakrajskove 9 2000 Maribor Phone +386 22509333 Fax +386 22509335 okotech@siol.net SOUTH AFRICA SUPARUE SA (PTY) TD. Units 1.26. Simba Street Sebenza, Edenvale Phone +27-(0)11-4529800 Fax +27-(0)11-4529828 steve@suparule.co.za www.suparule.co.za SPAI GUIJARRO HERMAOS S. Poligono Industrial Virgen de butarque Isaac Peral, 6 28914 eganes (Madrid) Phone +34 91 6870022 Fax +34 91 6876616 theben@guijarro-hnos.es www.guijarro-hnos.es SWEDE GYCOM SVESKA AB Box 1203 Stockholmsvägen 116 18312 Täby Phone +46 8 56201100 Fax +46 8 7920654 info@gycom.se www.gycom.com SYRIA BOUZO ERB Trading-Consulting P.O.Box 33175 Damascus Phone +963 11 3311306 Fax +963 11 3339898 bouzo_f@z&.com TAIWA CAAA EECTRIC CORP. P. O. 6F5 o. 63 Sec 2 Chang An East Rd. Taipei 104 Phone +886 2 25082331 Fax +886 2 25084744 canaano@ms15.hinet.net www.canaan-elec.com.tw TUESIA ABE AFRIQUE Zone Industrielle "Morize" T 2090 MORAG Phone +216 79350955 Fax +216 79350986 tfe.abelafrique@topnet.tn www.abeleclairage.com TURKEY GÖKHA EEKTRIK Perpa Elektrokent Is Merkezi A Blok K.8 o. 692-694 Okmeydaný/Ýstanbul Phone +90 212 221 32 36 Fax +90 212 221 32 40 ufuk@gokhanelektrik.com.tr www.gokhanelektrik.com.tr UKRAIE KVK-Electro, td. 43 Kikvidze Str. 01103 Kyiv Phone +380 44 4962883 Fax +380 44 4962885 info@kvk.kiev.ua www.kvk-elektro.com.ua UITED ARAB EMIRATES BI HAM EECTROMECH. EST. P. O. Box 4301 Dubai Phone +971 4 6742273939 Fax +971 4 2217619 bheet@emirates.net.ae URUGUAY BERO S.A. Av. Gral. San Martin 2761 esq. Burgues Montevideo Phone +598 2 2002862 Fax +598 2 2002862 beron@beron.com.uy www.beron.com.uy USA UMEITE EECTROIC CO. 2331 orth 17th. Av. Franklin Park, Illinois 60131-3475 Phone +1 847 4551450 Fax +1 847 4550127 customerservice@lumenite.com www.lumenite.com VIETAM RUDOF IETZ, IC. Representative Of ce Vietnam 162 Pasteur Street District 1, Ho Chi Minh City Phone +84 8 382 95 215 Fax +84 8 382 44 550 theben@lietz.com.vn 15 253

Theben AG worlwide Agencies and KX partners Theben AG AGECIES IDIA BE IGHTIG (DIVISIO OF BHAVAA IGHTIG PVT TD.) 10, Rose Blossom, 18, 18/A, Sitladevi Temple Road Mahim, Mumbai 400 016 Phone +91 22 2444 4441 Fax +91 22 2444 3626 sales@bellighting.net www.bellighting.net ORWAY STORK Brynsveien 100 1352 Kolsas Phone +47 67 17 64 00 Fax +47 67 17 64 01 stork@stork.no www.stork.no PARTERS UXEMBOURG MARCO ZEER 4, rue de la Foret 8065 Bertrange Phone +352 44 15 44 1 Fax +352 45 57 73 contact@zenner.lu www.zenner.lu ORWAY STORK Brynsveien 100 1352 Kolsas Phone +47 67 17 64 00 Fax +47 67 17 64 01 stork@stork.no www.stork.no UITED ARAB EMIRATES EuroSmarTech..C. P.O.Box 25 Dubai U.A.E. Phone +971 4 3390000 ext. 159 Fax +971 4 3395544 aalamin@alyousuf.com THAIAD ibuilt AUTOMATIO CO., TD. 44/78 79 M.8 Ramintra 63/1 Rd Ta-rang, Bangkhen, Bangkok 10230 Phone +66 2946 52012 Fax +66 2946 5200 patomporn@ibuilt.co.th TURKEY OSKAR EEKTRIK SA TIC TD. STI. Karman Ciftilik Yolu Kurucular Sitesi Saadept Apte. 44/18 34752 Icerenköy-Ýstanbul Phone +90 216 575 37 31 Fax +90 216 577 04 85 omural@oskarelektrik.net CETIER EEKTRIK Sureyyapaþa Cad. o: 22 34893 Pendik/Ýstanbul Phone +90 216 390 87 96 Fax +90 216 390 28 38 cetinler@cetinler.com.tr www.cetinler.com.tr 15 254

Theben AG Advertising material order Free of charge Further detailed information is available on request free of charge! FAX +49 (0) 74 74/6 92-19 9 or local office see pages 252 254 Theben General catalogue 2010 Product catalogue TIME Product catalogue IGHT Product catalogue CIMATE Product catalogue KX building system engineering eaflet Presence detectors eaflet Movement detectors eaflet Small control units PHARAO-II eaflet iving comfort control units UXOR eaflet Theben everywhere at home eaflet 12 useful energy saving tips eaflet EERGY SAVIG IDEAS Under www.theben.de you can find the leaflets above as pdf-files. In addition, you can find downloads on the Internet at: Texts for tenders Operating instructions Databases KX-manuals KX-databases OBEISK-software Supplementary lists for units not in the current range Certificates Sender Company Street Phone Fax Contacts Post code/ocation Mobile E-mail Trade Industry Wholesale Please put me in contact with one of your technical advisors. Theben AG, Hohenbergstraße 32, 72401 Haigerloch, www.theben.de, Phone +49 (0) 74 74/6 92-0, Fax +49 (0) 74 74/6 92-150 15 255

Theben AG Hohenbergstraße 32, 72401 Haigerloch, GERMAY Postfach 56, 72394 Haigerloch, GERMAY Phone +49 (0) 74 74/6 92-0 Fax +49 (0) 74 74/6 92-150 info@theben.de, www.theben.de 9900600 1010 We reserve the right to make technical modi cations and improvements.