TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

Similar documents
Low Frequency Gyrotrons for Fusion

CPI Gyrotrons For Fusion EC Heating

Development of high power gyrotron and EC technologies for ITER

Recent ITER-Relevant Gyrotron Tests

A New 4MW LHCD System for EAST

RF Power Generation II

Experimental results and recent developments on the EU 2 MW 170 GHz coaxial cavity gyrotron for ITER

Detailed Design Report

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

High-power klystrons. The benchmark in scientific research. State-of-the-art RF sources for your accelerator

IOT RF Power Sources for Pulsed and CW Linacs

RF Solutions for Science.

Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

DEVELOPMENT OF X-BAND KLYSTRON TECHNOLOGY AT SLAC

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

X-Band Klystron Development at

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Status of BESSY II and berlinpro. Wolfgang Anders. Helmholtz-Zentrum Berlin for Materials and Energy (HZB) 20th ESLS-RF Meeting

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

DESIGN AND TECHNOLOGICAL ASPECTS OF KLYSTRON DEVELOPMENT

INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Improvements to Siemens Eclipse PET Cyclotron Penning Ion Source

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

SRS and ERLP developments. Andrew moss

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

Department of Electronics and Communication Engineering Shrinathji Institute of Technology & Engineering, Nathdwara (Raj.)

A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Design Studies For The LCLS 120 Hz RF Gun Injector

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

TOSHIBA Industrial Magnetron E3328

CEBAF 8 kw CW KLYSTRON SPECIFICATION EE0043, Rev. H January 15, 1998

Klystron Tubes. Two forms of such a device, also called linear beam klystron, are given in the following figure.

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

Karin Rathsman, Håkan Danared and Rihua Zeng. Report from RF Power Source Workshop

Elements of a Television System

INFN School on Electron Accelerators. RF Power Sources and Distribution

CEPC Klystron Development

Lecture 17 Microwave Tubes: Part I

RF Upgrades & Experience At JLab. Rick Nelson

DC ELV Accelerators: Development and Application

A SHEET-BEAM KLYSTRON PAPER DESIGN

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Spear3 RF System Sam Park 11/06/2003. Spear3 RF System. High Power Components Operation and Control. RF Requirement.

Review of Diamond SR RF Operation and Upgrades

DELIVERY RECORD. Location: Ibaraki, Japan

A Unique Power Supply for the PEP II Klystron at SLAC*

RF considerations for SwissFEL

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Optical Cryostat - Omniplex TM

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

25W 9xxnm Uncooled Multimode Laser Diode Module

Chris Gilmour Studies into the Design of a Higher Efficiency Ku Band ring-loop Travelling Wave Tube SWS using the CST PIC Software.

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

Investigation of Radio Frequency Breakdown in Fusion Experiments

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

The PEFP 20-MeV Proton Linear Accelerator

Design of a 50 MW Klystron at X-Band*

Solid State Modulators for X-Band Accelerators

650MHz/800kW Klystron Development at IHEP

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

The Construction Status of CSNS Linac

Quality produced by means of electron beam

Photo cathode RF gun -

Next Linear Collider. The 8-Pack Project. 8-Pack Project. Four 50 MW XL4 X-band klystrons installed on the 8-Pack

Pulses inside the pulse mode of operation at RF Gun

Status and Plans for PEP-II

SLS RF operation report 2003

4.4 Injector Linear Accelerator

Cyclotron Institute upgrade project. H. L. Clark, F. Abegglen, G. Chubarian, G. Derrig, G. Kim, D. May, B. Roeder and G. Tabacaru

RF Design of the LCLS Gun C.Limborg, Z.Li, L.Xiao, J.F. Schmerge, D.Dowell, S.Gierman, E.Bong, S.Gilevich February 9, 2005

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

Cathode Studies at FLASH: CW and Pulsed QE measurements

An RF Excited Plasma Cathode Electron Beam Gun Design

Technology Challenges for SRF Guns as ERL Sources in View of Rossendorf work

This work was supported by FINEP (Research and Projects Financing) under contract

Optical Cryostat - Economy

!"!3

These tests will be repeated for different anode positions. Radiofrequency interaction measurements will be made subsequently. A.

K800 RF AMPLIFIER TUBE UPGRADE

3B SCIENTIFIC PHYSICS

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

Transcription:

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON V.I. Belousov, A.A.Bogdashov, G.G.Denisov, V.I.Kurbatov, V.I.Malygin, S.A.Malygin, V.B.Orlov, L.G.Popov, E.A.Solujanova, E.M.Tai, S.V.Usachov Gycom Ltd, Nizhny Novgorod branch Bildg.7, Larina street, Nichny Novgorod, 603107, Russia e-mail: tai@gycomnn.nnov.ru Information about produced in 2003 CW gyrotrons is presented. 84 GHz gyrotron is designed for operation in two regimes: 200 kw / CW and 500 kw / 10 s. During tests in NIFS, Japan following regimes was achieved: 200 kw / 180 s and 400 kw / 10 s after MOU. 82.7 GHz gyrotron is intended for operation in IPR, India. During it s factory acceptance tests 200 kw, 1500 s regimes were demonstrated. Besides gyrotrons the systems include magnets, matching optic units (MOU), dummy loads and transmission lines. Main characteristics of this components are shown. Activity of GYCOM during two last years was connected with production 200 kw CW gyrotrons intended for plasma heating experiments in National Institute for Fusion Science, Japan and in Institute for Plasma Research, India. At the fig.1 the external view and main dimensions of the 84 GHz CPD gyrotron are shown. Gyrotron uses the brazed diamond window disk from de Beers. It s setting diameters in cryomagnet equal 139 / 140 mm. Gyrotron has diode-type electron gun with cathode diameter 69 mm, power depression lens is located after cavity-radiator unit, all mirror of quasioptic converter are grounded. CPD insulator is placed under the cryomagnet, during CW operation it is cooled by oil. Cavity operating mode is TE 12.5, the stray radiation inside the tube is absorbed by inner absorbers with developed surface. The gyrotron has 12 circuits of water cooling, for CW operation achievement all elements of tube including the body are designed with one s own cooling. In June, 2003 the gyrotron was finally tested at the GYCOM s site factory in N.Novgorod. The designed output parameters was 200 kw in CW operating regime and 500 kw in 10 s operating regime.

At the Fig.2 the dependencies of gyrotron output power and efficiency on the beam current are shown. The graphs were taken off in long pulse regime. Calculated accelerating (kw) η (%) voltage equals 68 kv. Output power about 200 500 kw was obtained at beam current 9 A, cathode 400 voltage U c =-46 kv, anode voltage Ua=+22 kv with 300 efficiency almost 49.5%. Power 500 kw was η obtained at the current 21 200 60 A at the same beam 55 voltage with efficiency 100 50 52%. Optimum regime of 45 oscillation was 360 kw 0 output power at beam 3 5 7 9 11 13 15 17 19 21 Ibeam (A) current 13.5 A with efficiency 58%. Fig.2 Output power and efficiency η vs. electron beam current I beam. The power losses were measured in different gyrotron system units. The result is: 11% is loosed in inner gyrotron absorbing surface, including gyrotron body, 0.75% is loosed in diamond window unit, not only in the disk. Gaussian wave beam purity after the output window appeared to be about 93%, 9% of penetrated through the window power is absorbed in MOU. The gyrotron in November 2003 and January 2004 was tested at the customer site in NIFS at the vacuum system conditions. Additionally the system consists of GYCOM s vacuum MOU with pair mirrors for 31.75 mm in diameter wavequide transmission line feeding, magnet without liquid helium filling provided by the NIFS, dummy load and wavequide line, produced by General Atomic. In the Table 1 the demonstrated operating regimes are shown. The system worked as in dummy load and in LHD machine. Operation in machine was more reliable and useful for gyrotron because of power reflection from it was less than from dummy load. But long work in CW regime with waveguide line caused the waveguides overheating and pressure rise as result. This reason limits the gyrotron system operation at the present stage. Table 1. Demonstrated in NIFS operating regimes (during tests in NIFS the efficiency of operation was less than during factory tests because of the operating regime did not optimized). n, kw τ, s U c +U a, kv U c, kv I, A Note Reason of operation stop 1 145 690 67 51 9.2 In dummy load Pressure rise

2 200 240 67.5 51 9.5 In LHD machine Pressure rise 3 400 10 67 49 19 In dummy load Arc-detector At the Fig.3 oscillograms of gyrotron CW operation on the 200 kw output power level are shown. The oscillorams confirm that stabilization of the gyrotron operation was achieved. Full thermal balance takes place after about 4 minutes, during this time the beam current stops to growth and it deviation does not exceed 5% (about 0.5 A on the 10 A level). The current of ion pump does not growth after about I beam U a I a U c I pump several hundred Fig.3 Oscillograms of 84 GHz gyrotron milliseconds. CW operation. The photos 1, 2 show view of gyrotron lower part prepared for installation into the oil tank and the gyrotron installed in magnet with side view of MOU. Photo 1. Gyrotron lower part. Photo 2. Gyrotron in magnet and MOU. The design of second produced 200 kw CW gyrotron little differs from the previous description. The main are: 157 / 158 mm setting diameters in the cryomagnet, relief window for stray radiation remove, cavity operating mode TE 10.4, cathode diameter 51 mm. Designed regime is 200 kw CW operation after transmission line. Testing longevity of operation equals 1000 s. All gyrotron system components - gyrotron, cryomagnet, MOU for waveguide transmission

line with diameter 63.5 mm feeding and calorimetric load - were elaborated and manufactured in GYCOM. The system is able for operation with over pressure about 0.5 atm. The dependencies of the output power and efficiency on the beam current at the optimized regimes are shown at Fig.4. Measured output power losses distribution is: gyrotron inner absorbed surface 6%, relief window 5%, diamond window unit 0.55% (it is less than in 84 GHz gyrotron due to the more narrow output wavebeam), MOU 12% and transmission line 6%. 300 200 100 0 (kw) 0 5 10 P η η(%) 60 50 40 I beam (A) Fig.4 Output power and efficiency η vs. electron beam current I beam. Oscillorams at Fig.5 of the 1000 s gyrotron operation with continues output power measurement by calorimetric load confirm the gyrotron stable and reliable operation. During factory acceptance test the regime with 1500 s continues operation was demonstrated, maximum HF energy in the tube switching on was about 0.3 GJ. I beam U a I a Uc I pump Fig.5 Oscillograms of 82.7 GHz gyrotron 1000 s operation. Modification of 82.7 GHz CW gyrotron with BN window and lowered up to 30 kv cathode voltage, 15 kv anode voltage operates with output power 35 kw in Guardian Industries company since 2003. The photos 3, 4, 5 show gyrotron in cryomagnet with the relief load, MOU and side view of the transmission line fragment.

Photo 3. Gyrotron in magnet Photo 4. MOU Photo 5. Waveguide line The conclusions are: two CW gyrotrons with 200 kw output power were produced and tested up to 1500s operation longevity, full thermal stabilization in the gyrotron system was achieved during about 4 5 minutes, utilization of relief window and stray radiation absorbers successfully decreases the thermal load in the gyrotron body at mentioned power level. But the rise of CW output power up to 500 kw and more in existing gyrotron design will cause the problems, which can be resolved by launcher utilization. At the present time GYCOM specialists fulfilled cold experiment with cavity operating mode TE 12.5 launcher, which demonstrated about 95-97% mode converter efficiency. Design of 84 GHz gyrotron is modified for 500 kw CW operation with tested launcher utilization. For purpose of production 170 GHz / 1 MW CW gyrotron the operating mode TE 25.10 launcher was calculated, manufactured and tested in short pulse experimental gyrotron in IAP. The result confirms 95-97% mode converter efficiency.