Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Similar documents
Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Philips StressVue Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

GWL/ Power Group Technology Solutions Stay Powered for the Future

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

RF Solution for LED Display Screen

Honeywell HomMed Wireless Scale Quick Reference Guide

Quick Start Guide Building and Scheduling a Show

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

2 Connect your video source

EEG A1452 SCTE-104 Inserter Frame Card

Calibrating and Profiling Your Monitor

Data Acquisition Instructions

2 Connect your video source

Any feature not specifically noted as supported is not supported.

SignalTap: An In-System Logic Analyzer

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

1 Synchronising Xsens with the Delsys Trigno EMG System

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

VNS2200 Amplifier & Controller Installation Guide

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Camera Setup Instructions

Using LightSpace CMS for User Created Calibration LUTs

Cablecast Server. Setup Guide. c Tightrope Media Systems For Cablecast version Build 74

RADIO FREQUENCY SYSTEMS

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Amino. Digital Television. Sun City & Hilton Head Island

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

Weschler AMT Software for the Enhanced Version Transformer Advantage

Interface sheet - Edan ST-1212 Stress - CPET ergometer

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

Installation Note. Agilent 89441A Option AYC Installation Kit

2 Connect your video source

Operating Instructions

Installation & Operational Manual

Modbus for SKF IMx and Analyst

June/July 2016 Med Tips

Audio Design Associates (ADA)

Med Tips. PRODUCT INFORMATION FreeStyle Battery Warranty. Q: What is the warranty for my FreeStyle Battery?

Scan Converter Quick Installation Guide

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Receiver Integration Note

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

R4 AIS Class B Transponder

22" Touchscreen LED Monitor USER'S GUIDE

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

FSI Calibration Guide Using I1 / LightSpace / Resolve

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

IMPORTANT! This instruction guide explains how to install your CCTV system.

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

SXGA096 DESIGN REFERENCE BOARD

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

Transmitter Interface Program

Integration of the Zetasizer µv and OmniFACE into an SEC system

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

Agilent 87075C Multiport Test Set Product Overview

PXL2760MW LED LCD Monitor

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Setup Guide. Panasonic BT-4LH310. Rev. 1.1

COLOR TFT LCD MONITOR. Manual

P XGA TFT Monitor. User s Manual

VNS2210 Amplifier & Controller Installation Guide

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

PLASMA MONITOR (PT20 UVVis) USER GUIDE

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

WQ Series Water Quality Bench top Meters

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Quick Setup 1 Unpack the projector

Cablecast SX. Setup Guide. c Tightrope Media Systems For Cablecast version Build 206

DXP A0808 Quick Start

1 OVERVIEW 2 WHAT IS THE CORRECT TIME ANYWAY? Application Note 3 Transmitting Time of Day using XDS Packets 2.1 UTC AND TIMEZONES

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0) on the disk sent with the printer. Follow the steps (see the picture):

YAMAHA 03D SERIAL AUDIO MIXER

CHAPTER 3 EXPERIMENTAL SETUP

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Setup Guide. Murideo SIX-G. Digital Video Generator. Rev. 1.6

PLL1920M LED LCD Monitor

Transcription:

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes To setup Tango M2 with the XScribe cardiac stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with the XScribe. This cable enables the XScribe to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the XScribe display and reports. o SunTech Part Number = 91-0013-01 o Connection Ends: XScribe Connection 9 pin female Tango M2 Connection 9 pin female ECG Trigger Cable provides the ECG signal from the XScribe to the Tango M2. o SunTech Part Number = 91-0011-01 o Connection Ends: XScribe Connection BNC male Tango M2 Connection BNC male Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 1 of 6

Tango M2 Monitor RS-232 Connection Part # 91-0013-01 ECG Trigger Connection Part # 91-0011-01 SunTech Tango M2 BP Monitor TTL (BNC) Cable from M12RFXXX-USB Unit Power Cord Microphone Mortara M12RFXXX- USB RS232 Data Cable (Com2) BP Cuff Mortara XScribe Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 2 of 6

Mortara USB Interface M12RFXXX-USB ECG Trigger TTL 2. Connect the RS-232 Cable From: the RS-232 connection on the rear panel of the Tango M2. To: the COM 2 port on the back of the XScribe. If a second serial port is not available, a PC board to provide this 2 nd serial port may be required (contact Mortara for details). 3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the TTL output connection on the back of the Mortara M12RFXXX-USB module. *Note If this port is already in use a BNC Splitter may be needed, SunTech Part Number = 64-0080-00. 4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. d. Using the UP or DOWN arrows, scroll through the list until X-Scribe is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 3 of 6

5. X-Scribe V3.xx System Setup a. Highlight and click on Settings from the X-Scribe main menu. The Configuration Settings window will be displayed. b. In the Exercise Options Tab, click on the NIBP drop down menu. c. Select SunTech Tango. d. Highlight and click on the Save Profile button. e. Select Yes when prompted by This profile will be overwritten Do you want to continue? f. Repeat steps b through e for each Profile that you wish to utilize the SunTech Tango M2 automatic BP monitor. 6. XScribe V5.xx System Setup g. Select the System Configuration icon from the XScribe main menu. The System Configuration window will be displayed. h. Select the Modality Settings button and then the Miscellaneous tab to open dialog allowing you to click on the Automatic radio button. Click on Save Changes to set automatic BP as default for all stress exams, and then Exit. i. After starting a stress test, select Local Conf/F2 in the observation phase and click on the BP Equipment drop down list to select SunTech BP. Note: The XScribe Blood pressure entry control for Exercise and Recovery phases will now automatically initiate and acquire BP readings from the SunTech Tango BP Monitor. Mortara Instrument, Inc. Technical Support - (888) MORTARA FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 4 of 6

Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. 2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). 3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 5 of 6

Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com Mortara XScribe Version 3 and Version 5, Tango M2 Interface Notes Page 6 of 6