Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

Similar documents
Modular Lube Lubrication Systems System Controls

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

TROJANUVTORRENTTM. Drinking Water Disinfection

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Model KBF P 240 Humidity test chambers with ICH-compliant light source

7 Lighting Technology

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter

Wall-/Pipe-Mount Level Indicator

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

Features. Specifications. Finish. Notes

Roof-mounted Blue e+ cooling unit Integration solution VX25

Model KBF 115 Constant climate chambers with large temperature / humidity range

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow control with actuator IFC

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Series description: Wilo-Jet HWJ

Optical Cryostat - Omniplex TM

DM 50 / DM / 2- component dosing and mixing system. engineering

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P1350P1/P1500E1 50Hz

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Bimetal Temperature Switch

P Output Ratings. Dimensions and Weights. Prime Rating

AF-300 E11 Adjustable Frequency Drive

General Specifications

istep STEPPER MOTOR PUMP

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

ELE C TRO MAG N E T I C FLO W M E T E RS

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

Agilent High Capacity RV Pumps & Roots Pumping Systems

Admiss. counterpressure

Model KBF 1020 Constant climate chambers with large temperature / humidity range

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

2291 Guided Wave Radar Level Transmitter

P Output Ratings. Dimensions and Weights. Prime Rating

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

IONIVAC Transmitter ITR 90

P Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

2.9 Sigma/ 2 Plunger Metering Pumps

Cylindrical Photoelectric Sensor CY-100 SERIES

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

PURION THE BEST SOLUTION

Flow Measurement SITRANS F M

TFRH Hygienic RTD temperature sensor. CombiTemp TM

EXLUX ECOLUX 6480 Series

TFRN Industrial RTD temperature sensor. CombiTemp TM

istep STEPPER MOTOR PUMP

EXLUX ECOLUX C-LUX 6480 Series

Model KT 115 Cooling incubators with thermoelectric cooling

Type D mechanical diaphragm

TFRN Industrial RTD temperature sensor. CombiTemp TM

Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

TFR5 Room or outdoor temperature sensor. CombiTemp TM

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

ULTRALOW TEMPERATURE FREEZERS -86 C

Photoelectric Sensors E3F2

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

WCHE BTU/Hr Watts

Single Point Flow Monitor SW118 SW119

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Model KT 53 Cooling incubators with thermoelectric cooling

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

GRUNDFOS alldos product information. The solution for complex dosing tasks

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Gear Pump Units. For single-line lubrication systems

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Liner Quattro AC XB RGBW

Frequency Converter Fv

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

GENESIS Indoor Air Conditioners

Transcription:

Main Applications Disinfection of Primary, secondary and tertiary treated wastewater effluents for discharge Wastewater for reuse (e.g. for irrigation of parks, agriculture) Process water for industrial use Aquaculture applications (up to 250m³/h with PE channel) Water temperature recommended range 5 45 C (41-113 F) possible range 0 60 C (32-140 F) UV transmittance (@ 254 nm, 1 cm) min. 45 % Flow capacity Technical Description Subject to change without notice. 1/6 max. 0 m³/h max. 4,535 GPM Open UV channel system Lamp Configuration: Horizontal, parallel to flow Module Configuration : 2 to 8 lamps per module Bank Configuration: Up to 4 modules per bank Channel Configurations: Up to 2 banks per channel (Duty/Duty, Duty/ Assist, Duty/Standby) Baffle Plate to smooth out the water flow for optimum hydraulic conditions Fixed finger weir to regulate and maintain the water level in the open UV Channel. Highly efficient low pressure WEDECO ECORAY UV lamps, easily removable Options Channel Options: Concrete, (SS 304), HDPE Automatic wiping system Calibrated UV intensity monitoring system Dose Pacing Control (incl. variable lamp output) SCADA (Ethernet IP, Modbus TCP, Profibus DP) Lifting device UV CHANNEL (alternate options): Included: UV MODULE : UV Lamp - Concrete (SS inlays supplied for one module-wide configurations), - (SS 304), or - HDPE (marine grade) - Inlet-/ Outlet boxes (not with concrete) - Brackets for UV modules - Fixed finger weir - Baffle plate with attachments (standard for 2, 3 and 4 module wide configurations; optional for others) - SS liner at UV section (for 1-module wide concrete channels only) - Channel covers (provided with same material as channel construction; not included for concrete installations) stainless steel SS 3Ti (1.4571); PETP, Quartz Sealing : FPM incorporating frame and module cover plate for UV irradiation protection (additional channel cover recommended -for concrete channels only) Cylindrical, highly efficient WEDECO ECORAY -UV lamp, operated with electronic ballast UV Sensor Calibrated according to ÖVGW M5873-1, 0 measuring angle accuracy ±3 %, selectivity 240-2 nm > %, ageing stability, temperature stability up to 70 C during continuous operation

ELECTRICAL CABINET Design Single cabinet to be installed adjacent to the channel (max. distance module / electrical cabinet: 2.5 m (8 ft.)) 12/ IP55 Enclosure: Painted Sheet Steel 4X/ IP66 Enclosure: (SS 304) Ready for connection, incl. module connectors Ambient temperature range 10-40 C (41 104 F) 10-50 C (41 122 F) for outdoor cabinets with A/C Ambient humidity max. 95% @ 25 C Supply Voltage cul: 480/277 +/- 10 %, 60 Hz (5 Wire WYE; L1,L2,L3,N,GND) CE: 400/230 +/- 10 %, 50 Hz (TN-S Net) Power factor ~ 0.98 Components Customer Terminals In: Out: SCADA: Automatic Wiping System (Option) UV Dose Pacing (incl. variable lamp power) (Option) Mains isolator switch Electronic ballasts Electronic single-lamp-surveillance UV intensity measuring system with two limit switches (Optional) Enclosure fan filters (for 12/ IP54 and 4X/ IP66 enclosure) A/C option (for 4X/ IP66 enclosure) EcoTouch controller with blue illuminated operator touch panel displaying the following System status Lamp Status Alarm messages Process values Available languages: English, German, Spanish, French, Italian, Portuguese remote ON / OFF (230V or volt-free), water flow rate (4 20 ma) UV dose adjustable (4 20 ma), Volt-free contacts for: System running, high priority alarm, low priority alarm System status Lamp Status Alarm messages Process values PTFE/ Viton sandwich wipers automatically clean the quartz tubes and sensor window in adjustable intervals. Pneumatically driven by a compressed air that needs to be oil-free. WEDECO s TAK 55 Smart TM control philosophy gives assured disinfection by measuring continuously the UV-C intensity after travelling through the water. The EcoTouch Controller uses the intensity value, given by the UV-C sensor and computes along with the flow rate signal the applied dose to the water. This ensures that the specified UV-C dose is being applied and the desired disinfection level will be achieved, while energy consumption is minimized. Subject to change without notice. 2/6

TAK55 Smart (1 bank) UV Lamps ECORAY ELR 30 Lamp power (W) 315 UV-C output 254 nm (W) 150 Quantity 2 4 6 8 12 24 32 Lamp life (h) 14000 UV Module Module length (mm/in) 2,000 / 78.74 Weight per module (kg/lbs), 37/ 80 No. of modules 1 1 1 2 2 2 3 4 Lamps per module 2 4 6 4 6 8 8 8 IP 65 Electrical Cabinet 12/ IP55 w/ fan Enclosure Painted Sheet Steel 800 x 2100 x 600 (31.5 x 82.7 x 23.6) Weight (kg / lb) 481 / 1060 Power consumption (kw) 0.76 1.39 2.02 2.65 3.91 5.25 7.77 10.36 12/ IP 55 4X/ IP66 w/ fan Enclosure 976 x 2200 x 782 (38.4 x 86.6 x 30.8) Weight (kg / lb) 508 / 1120 Power consumption (kw) 0.76 1.39 2.02 2.65 3.91 5.25 7.77 10.36 4X/ IP66 4X / IP 66 w/ AC Enclosure 18 x 2200 x 600 (46 x 86.6 x 23.6) Weight (kg / lb) 580 / 1278 Power consumption (kw) 3.78 4.42 5.05 5.68 6.94 8.27 10.79 13.38 4X/ IP66 General Power losses/ heat loss (W) 336 399 462 525 651 786 1138 1399 cul: 480/277 +/- 10 %, 60 Hz (5 Wire WYE; L1,L2,L3,N,GND) Supply voltage CE: 400/230 +/- 10 %, 50 Hz (TN-S Net) Subject to change without notice. 3/6

TAK55 Smart (1 bank) SS UV Channel (Option) Piping connection for Standard (DN/ ANSI) flange. Channel weight (kg / lbs), 3240 / 128 850 / 33.5 DN1 6 132/ 2 3460/ 137 940/ 37 DN200/ 8 8/ 370 560 / 22 4010/ 158 1045/ 41 261/ 575 610 / 24 4015 (4245)*/ 158 (8)* 1070/ 42 272/ 600 930 / 36.5 5055 (7501)* / 199 (295)* 11/ 47 DN400/ 445/ 980 PE UV Channel (Option) 455 / 18 455 / 18 605 / 23.7 655 / 25.7 NA 3660 / 144 3925 / 154.5 4585 / 180.5 4585 / 180.5 NA 855 / 33.7 950 / 37.4 1055 / 41.5 1080 / 42.4 NA Piping connection Standard (DN/ ANSI) flange. DN1 6 DN200/ 8 NA Channel weight (kg / lbs), 130 / 280 205 / 450 2 / 635 310 / 685 NA Concrete UV Channel Insert (Option) Channel insert Incl. Incl. Incl. NA NA Baffle plate Please refer to the respective GA drawings Inlet baffle plate optional optional optional included included included included included *Longer channel length for high flow weir (TAK 55 Smart 2-2 /3-2 HF) Subject to change without notice. 4/6

TAK55 Smart (2 banks) UV Lamps ECORAY ELR 30 Lamp power (W) 315 UV-C output 254 nm (W) 150 Quantity 4 8 12 24 32 48 NA Lamp life (h) 14 000 UV Module Module length (mm/in) 2,000 / 78.74 NA Weight per module (kg/lbs), 37/ 80 No. of modules per bank 1 1 1 2 2 2 3 NA Lamps per module 2 4 6 4 6 8 8 NA IP 65 Electrical Cabinet 12/ IP55 w/ fan Enclosure Painted Sheet Steel 800 x 2100 x 600 (31.5 x 82.7 x 23.6) Weight (kg / lb) 508 / 1120 Power consumption (kw) 1.4 2.66 3.99 5.25 7.77 10.42 15.46 NA 12/ IP 55 4X/ IP66 w/ fan Enclosure 18 x 2200 x 600 (46 x 86.6 x 23.6) Weight (kg / lb) 580 / 1278 Power consumption (kw) 1.4 2.66 3.99 5.25 7.77 10.42 15.46 NA 4X/ IP66 4X / IP 66 w/ AC Enclosure 976 x 2200 x 782 (38.4 x 86.6 x 30.8) Weight (kg / lb) 580 / 1278 Power consumption (kw) 4.42 5.68 7.02 8.28 10.79 13.45 18.49 NA 4X/ IP66 General Power losses/ heat loss (W) 399 525 651 786 1138 1399 1912 NA cul: 480/277 +/- 10 %, 60 Hz (5 Wire WYE; L1,L2,L3,N,GND) Supply voltage CE: 400/230 +/- 10 %, 50 Hz (TN-S Net) Subject to change without notice. 5/6 NA

TAK55 Smart (2 banks) SS UV Channel (Option) Piping connection Standard (DN/ ANSI) flange. Channel weight (kg / lbs), 5684 / 223,75 850 / 33.5 DN1 6 236/ 522 56/ 232,49 940/ 37 DN200/ 8 276/ 610 560 / 22 6458/ 254,25 1045/ 41 377/ 832 610 / 24 6458 (6693)*/ 254,25 (263,5)* 1070/ 42 394/ 870 930 / 36.5 7246 (7501)*/ 285,31 (295,3)* 11/ 47 DN400/ 514/ 1136 Concrete UV Channel Insert (Option) Channel insert Incl. Incl. Incl. NA NA Please refer to the respective GA drawings Baffle plate Inlet baffle plate optional optional optional included included included included included *Longer channel length for high flow weir (TAK 55 Smart 2-2 /3-2 HF) Options/ Accessories (extra charges) ÖNORM conform germicidal UV sensor Automatic wiping system Compressor PE/ SS channels Spare module Crane for module lifting Subject to change without notice. 6/6