Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Similar documents
Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Cooling incubators with thermoelectric cooling

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model KT 170 Cooling incubators with thermoelectric cooling

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Forced Convection Laboratory Ovens

Cooling systems for ORBIMAT

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Label Applicator HERMA 400

Sensor technologies Proximity sensors Series ST4. Brochure

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Magnetic Stirrers Magnetic Stirr

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Product Data Sheet 8506 VW-691

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

DMP 331i / DMP 333i LMP 331 i

CTC Series. Compact Temperature Calibrator

ULTRALOW TEMPERATURE FREEZERS -86 C

Product Brochure. June M5 Series. Metal Detector

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

SMG_GB_ :55 Uhr Seite 1 C M Y CM MY CY CMY K Shakers and Mixers Probedruck

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Frequency Converter Fv

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Orbit TM DIGITAL SHAKERS

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

XPert Filtered Balance Systems

LABSONIC M The ultrasonic homogenizer for every application. Benefits

Tube Roller Shakers. User Guide. Version 1.2

Product Data Sheet 4656 EZ

POWER MOLE SERIES DA GAO RGBT RADIX

HDMI over CAT5 HDBaseT Extender - 4K

LAUREL ELECTRONICS, INC.

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Product Data Sheet 4656 ZW

Series description: Wilo-Drain VC

IKA Analytical line Calorimeters C 2000

Roof-mounted Blue e+ cooling unit Integration solution VX25

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Optical Cryostat - Omniplex TM

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)


PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

Process Transmitter RMA 422

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

120cm (4x36 Watt) incl. Splitter Instruction Manual

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K

Programat P310. Economical firing performance. Top-quality results. The user-friendly furnace. Now with new OSD display

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

SPECIAL SPECIFICATION 2344 TMC Support Equipment

TFRH Hygienic RTD temperature sensor. CombiTemp TM

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

With vibration and high speed to top quality

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

Product Data Sheet 4650 N-465

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

7.5ft Outdoor Double-Sided Interactive LCD Sign, Transit Center Kiosk Model: NISDK-550PCT, 55 Double-Sided

Ethernet to VGA over IP Converter

Engineered to meet your needs T he oldest name in stud welding,

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

User Manual RTHDBT402PT & RTHDBT402PR

Linear encoders without bearings incremental System for linear motion feedback

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

IONIVAC Transmitter ITR 90

Manual. Simrad IS80 Wind Instrument WI80. English

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

APPLICATIONS. Automatic warehouse. Trasportation lines

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Dissolved Oxygen Transmitter

Transcription:

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CB series CO 2 incubator can perform complex cultivation experiments as well as specific enviromental conditions. BENEFITS Hot air sterilization at 180 C, with sterilizable built-in CO 2 sensor minimizes the risk of contamination Homogeneous temperature distribution thanks to VENTAIR air jacket system Stable ph-values thanks to drift-free CO 2 IR sensor technology Saturated relative humidity up to 95 % RH Easy cleaning thanks to seamless, deep-drawn inner chamber MAIN FEATURES Model 160 Model 160 Temperature range: room temperature plus 7 C to 60 C Humidity range: up to 95% RH Alternative O 2 control ranges: 0.2-20 vol. % O 2 or 10-95 vol. % O 2 (O, GO versions) Auto-sterilization with hot air at 180 C Double-pan humidification system with condensation protection CO 2 gas-mixing jet with Venturi effect Hot-air sterilizable CO 2 sensor with infrared technology Display via color LCD monitor Lockable door handle Tightly-sealed inner door made of tempered safety glass Seamless, deep-drawn inner stainless steel chamber 3 perforated stainless steel shelves Units are stackable with stacking adapter Troubleshooting system with visual and audible alarms Computer interface: Ethernet Internal data recording and USB interface Zero-voltage alarm contact ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model CB 160 Standard CB160-230V 9040-0092 5.3 200 240 V 1 ph 50/60 Hz 100 120 V 1 ph 50/60 Hz with 4x divided inner door CB160-230V-G 9040-0100 with O 2 control CB160-230V-O 9040-0094 with O 2 control and with 4x divided inner door CB160-230V-GO 9040-0102 Standard CB160UL-120V 9040-0093 with 4x divided inner door CB160UL-120V-G 9040-0101 with O 2 control CB160UL-120V-O 9040-0095 with O 2 control and with 4x divided inner door CB160UL-120V-GO 9040-0103 Request more info Page 1 / 7

TECHNICAL DATA (Version 1-4 from 8) Description CB160-230V 1 CB160-230V-G 1 CB160-230V-O 1 CB160-230V-GO 1 Article Number 9040-0092 9040-0100 9040-0094 9040-0102 Performance Data Temperature Temperature range 7 C above ambient temperature to [ C] 60 60 60 60 Temperature variation at 37 C [± K] 0.3 0.3 0.3 0.3 Temperature fluctuation at 37 C [± K] 0.1 0.1 0.1 0.1 Recovery time after 30 seconds door open at 37 C [min] Performance Data Climate Humidity range [% RH] 90 95 90 95 90 95 90 95 CO 2 -Data CO 2 range [Vol.-% CO 2 ] 0 20 0 20 0 20 0 20 CO 2 measurement IR IR IR IR CO 2 Recovery time after 30 seconds door open at 5 Vol.-% CO 2 [min] O 2 -Data Standard O 2 control ranges: O 2 range [Vol.-% O 2 ] 0.2 20 0.2 10 O 2 control ranges with option: O 2 range [Vol.-% O 2 ] O 2 Recovery time after 30 seconds door open at 5 Vol.-% O 2 [min] 10 95 10 95 12 12 Electrical data Rated Voltage [V] 200 240 200 240 200 240 200 240 Power frequency [Hz] 50/60 50/60 50/60 50/60 Nominal power [kw] 1.3 1.3 1.3 1.3 Unit fuse [A] 10 10 10 10 Phase (Nominal voltage) [ph] 1 1 1 1 Outer dimensions Width net [mm] 680 680 680 680 Height net [mm] 920 920 920 920 Depth net [mm] 715 715 715 715 Wall clearance back [mm] 100 100 100 100 Wall clearance sidewise [mm] 50 50 50 50 Doors Inner doors 1 4 1 4 Unit doors 1 1 1 1 Internal Dimensions Width [mm] 500 500 500 500 Height [mm] 600 600 600 600 Depth [mm] 500 500 500 500 Measures Interior volume [L] 150 150 150 150 Net weight of the unit (empty) [kg] 107 108 106 110 permitted load [kg] 30 30 30 30 Load per rack [kg] 10 10 10 10 Environment-specific data Energy consumption at 37 C [Wh/h] 100 100 100 100 Request more info Page 2 / 7

Description CB160-230V 1 CB160-230V-G 1 CB160-230V-O 1 CB160-230V-GO 1 Article Number 9040-0092 9040-0100 9040-0094 9040-0102 Fixtures Number of shelves (std./max.) 3/6 2/2 3/6 2/2 TECHNICAL DATA (Version 5-8 from 8) Description CB160UL-120V 1 CB160UL-120V-G 1 CB160UL-120V-O 1 CB160UL-120V-GO 1 Article Number 9040-0093 9040-0101 9040-0095 9040-0103 Performance Data Temperature Temperature range 7 C above ambient temperature to [ C] 60 60 60 60 Temperature variation at 37 C [± K] 0.3 0.3 0.3 0.3 Temperature fluctuation at 37 C [± K] 0.1 0.1 0.1 0.1 Recovery time after 30 seconds door open at 37 C [min] Performance Data Climate Humidity range [% RH] 90 95 90 95 90 95 90 95 CO 2 -Data CO 2 range [Vol.-% CO 2 ] 0 20 0 20 0 20 0 20 CO 2 measurement IR IR IR IR CO 2 Recovery time after 30 seconds door open at 5 Vol.-% CO 2 [min] O 2 -Data Standard O 2 control ranges: O 2 range [Vol.-% O 2 ] 0.2 20 0.2 20 O 2 control ranges with option: O 2 range [Vol.-% O 2 ] O 2 Recovery time after 30 seconds door open at 5 Vol.-% O 2 [min] 10 95 10 95 12 12 Electrical data Rated Voltage [V] 100 120 100 120 100 120 100 120 Power frequency [Hz] 50/60 50/60 50/60 50/60 Nominal power [kw] 1.3 1.3 1.3 1.3 Unit fuse [A] 16 16 16 16 Phase (Nominal voltage) [ph] 1 1 1 1 Outer dimensions Width net [mm] 680 680 680 680 Height net [mm] 920 920 920 920 Depth net [mm] 715 715 715 715 Wall clearance back [mm] 100 100 100 100 Wall clearance sidewise [mm] 50 50 50 50 Doors Inner doors 1 4 1 4 Unit doors 1 1 1 1 Internal Dimensions Width [mm] 500 500 500 500 Height [mm] 600 600 600 600 Depth [mm] 500 500 500 500 Request more info Page 3 / 7

Description CB160UL-120V 1 CB160UL-120V-G 1 CB160UL-120V-O 1 CB160UL-120V-GO 1 Article Number 9040-0093 9040-0101 9040-0095 9040-0103 Measures Interior volume [L] 150 150 150 150 Net weight of the unit (empty) [kg] 107 108 106 110 permitted load [kg] 30 30 30 30 Load per rack [kg] 10 10 10 10 Environment-specific data Energy consumption at 37 C [Wh/h] 100 100 100 100 Fixtures Number of shelves (std./max.) 3/6 2/2 3/6 2/2 DIMENSIONS incl. fittings and connections [mm] OPTIONS AND ACCESSORIES back 30 mm 01 8012-1390 Access port with silicone plug left 30 mm 01 8012-1391 right 30 mm 01 8012-1392 Analog output 4-20 ma for temperature and CO 2 values (outputs not adjustable) 02 8012-0822 Base with casters 9051-0028 Calibration certificate O 2 for the O 2 control option; a measuring point in center of chamber at a specified O 2 percentage value 8012-0229 Calibration certificate, expanded for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1113 for temperature, measurement in center of chamber at specified temperature 8012-1132 Calibration certificate, temperature Calibration certificate, temperature and CO 2 temperature measurement incl. certificate and 27 measuring points at specified temperature 8012-1592 temperature measurement incl. certificate, 15-18 measuring points at specified temperature 8012-1571 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-1550 for temperature and CO 2, temperature measurement in center of chamber, CO 2 measurement performed using test gas at 37 C and 5 % CO 2 8012-1235 CELLROLL set modular, expandable roller bottle system for cell cultivation, 4 roller bottles 8012-0571 Electric access port 8-pin, for low voltage with LEMO socket (coverable) and LEMO plug (max. 24 V 2 A) 8012-0826 Gas cylinder connection set for CO 2, consisting of a gas tank pressure regulator with connection parts and 5-meter hose 8012-0014 for N 2, consisting of a gas tank pressure regulator with connection parts and 5-meter hose 8012-0016 for O 2, consisting of a gas tank pressure regulator with connection parts and 5-meter hose 8012-0015 Gas tank changer external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO 2, N 2 or O 2 ), with audible and visual alarms, as well as zero-voltage alarm output 8012-0408 Request more info Page 4 / 7

RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 Interface converter 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 Interface converter, USB / RS422 Interior socket O 2 control range RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) waterproof, switched flush-mounting box (LEMO) for nominal voltage in unit interior, coverable, with corresponding plug (nominal voltage; max. 3 A; protection class IP65) alternative to the standard range, for controlling O 2 concentrations between 10 and 95 vol. %, only in conjunction with option models with O 2 control 8012-0665 07 8012-0823 8012-1106 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 RS 422 interface in place of Ethernet, for communication software 8012-0824 RS 422 interface, accessories modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Shaker Professional Shaker and controller equipped with LEMO connectors, exclusively for CB with electric access port, 100 240 V, 50/60 Hz 8012-1772 Shaker Universal Shaker and controller connected via ribbon cable, universally applicable, 100 240 V, 50/60 Hz 8012-1771 Stainless steel 6004-0139 Shelf, perforated for divided inner door Stainless steel, divided 8012-0578 APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Stacking adapter, flat for thermally decoupled stacking of two identical units 9051-0035 Stacking frame stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units 9051-0020 SERVICES Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL10-0200 Instruction unit function instructions for operation and programming of the controller 18 DL10-0500 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL20-0400 Calibration services Calibration CO 2 including certificate, CO 2 measurement with analyzed test gas at 5 % or at specified value DL30-0401 Calibration O 2 calibration of O 2, including certificate (one measuring point in center of chamber at specified O 2 percentage) DL30-0402 Calibration temperature incl. certificate including certificate, one measuring point in center of chamber at specified temperature DL30-0101 Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature DL30-0118 Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature DL30-0127 Request more info Page 5 / 7

Temperature measurement 9 measuring points including certificate, 9 measuring points at specified temperature DL30-0109 Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL41-0200 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL44-0500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0876 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0963 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL02-1041 beginning with the date of delivery, wearing parts are not included DL02-1042 Request more info Page 6 / 7

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ folder. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Request more info Page 7 / 7