GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Similar documents
Philips StressVue Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Electrocardiogram (ECG) Version Date: 2017-FEB-15 Document Effective Date: 2017-MAY-15

Honeywell HomMed Wireless Scale Quick Reference Guide

1 Synchronising Xsens with the Delsys Trigno EMG System

DX-10 tm Digital Interface User s Guide

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Camera Setup Instructions

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

Integration of the Zetasizer µv and OmniFACE into an SEC system

GWL/ Power Group Technology Solutions Stay Powered for the Future

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Modbus for SKF IMx and Analyst

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

2 Connect your video source

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Activity P32: Variation of Light Intensity (Light Sensor)

June/July 2016 Med Tips

2 Connect your video source

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

22" Touchscreen LED Monitor USER'S GUIDE

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Wall Ball Setup / Calibration

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

TeamWork Kits Installation Guide

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

RF Solution for LED Display Screen

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

RADIO FREQUENCY SYSTEMS

PXL2470MW LED LCD Monitor

PXL2760MW LED LCD Monitor

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Operating Instructions

Manual Version Ver 1.0

PRECAUTIONS CONTENTS: Please follow these precautions:

REMOTE DISPLAY WIRELESS DECODER MK II

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ASSEMBLY AND CALIBRATION

PLL2210MW LED Monitor

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Med Tips. PRODUCT INFORMATION FreeStyle Battery Warranty. Q: What is the warranty for my FreeStyle Battery?

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

DIGITAL SPEAKER MANAGEMENT UK

WQ Series Water Quality Bench top Meters

AcoustiSoft RPlusD ver

PLL2710W LED LCD Monitor

USER MANUAL Full HD Widescreen LED Monitor L236VA

2 Connect your video source

EEG A1452 SCTE-104 Inserter Frame Card

LedSet User s Manual V Official website: 1 /

Amino. Digital Television. Sun City & Hilton Head Island

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

PL2410W LCD Monitor USER'S GUIDE.

Quick Setup 1 Unpack the projector

P-2 Installing the monitor (continued) Carry out as necessary

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Data Acquisition Instructions

COLOR TFT LCD MONITOR. Manual

PQ-Box 100 Quick Start Instructions

Auxiliary states devices

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

Quick Start Guide Building and Scheduling a Show

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

Instructions for Use: Video Inspection Scope with Display

USER MANUAL Full HD Widescreen LED Monitor L215IPS

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

Revision Protocol Date Author Company Description January Paul DOS REMEDIO S. Imagine Communications

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Scan Converter Quick Installation Guide

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Configuration Vestas VMP3500

Agilent 87075C Multiport Test Set Product Overview

Model KT 170 Cooling incubators with thermoelectric cooling

Transmitter Interface Program

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

IMPORTANT! This instruction guide explains how to install your CCTV system.

MANUAL ENG DT-2100 ENGLISH QPSK

Installation and Tuning Manual DAC 7000 DAC 2X

Using LightSpace CMS for User Created Calibration LUTs

Transcription:

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes To setup Tango M2 with your CardioSoft (V6.01 or higher), simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with the CardioSoft. This cable enables the CardioSoft to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the CardioSoft s display. o SunTech Part Number = 91-0013-01 o Connection Ends: GE Stress System Connection 9 pin female Tango M2 Connection 9 pin female ECG Trigger Cable provides the ECG signal from the CardioSoft to the Tango M2. o SunTech Part Number = 91-0009-01 o Connection Ends: GE Stress System Connection 9 pin male Tango M2 Connection BNC male GE CardioSoft v 6.01 and Higher Tango M2 Interface Notes Page 1 of 5

Tango M2 Monitor RS-232 Connection Part # 91-0013-01 ECG Trigger Connection Part # 91-0009-01 2. Connect the RS-232 Cable From: the RS-232 connection on the rear panel of the Tango M2. To: the COM port on the back of the computer. Notice which COM port the RS-232 is inserted into (you will need this information for Step 5.e). * Note - If all of the COM ports are occupied, a USB to RS-232 converter can be used. SunTech Part # 98-0057-00. 3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the DB 9 female connection on the CAM USB AT. 4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. GE CardioSoft v 6.01 and Higher Tango M2 Interface Notes Page 2 of 5

c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. d. Using the UP or DOWN arrows, scroll through the list until CardioSoft is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. CardioSoft Setup a. In the vertical menu bar on the right side, select System Configuration. b. In the System Configuration screen, click on the Devices tab on the top. c. Check that the TTL output is set to a Pulse Width [ms]: 50, Delay [ms]: 10, and Polarity: Positive. d. Go to BP Monitor and select SunTech. e. For Port, choose the COM port (1 or 2) that you have attached the RS 232 cable to in Step 2 above. f. Click OK to return to the main screen. FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. GE CardioSoft v 6.01 and Higher Tango M2 Interface Notes Page 3 of 5

2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). 3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 GE CardioSoft v 6.01 and Higher Tango M2 Interface Notes Page 4 of 5

Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com GE CardioSoft v 6.01 and Higher Tango M2 Interface Notes Page 5 of 5