Analog/digital watch Multi frequency reception, 4 digit LCD, 3 hands. Preliminary Specification

Similar documents
C-MAX. TSG200 Time signal generator TSG200. Time Signal Generator. Manual TSG200. RF Technology Specialist. Version. Revision. SPEC No.

C-MAX. CMM-9301-V3.1S Bluetooth 4.0 Single Mode HCI Module. Description. 1.1 Features

INSTRUCTIONS ANALOG/DIGITAL ATOMIC WATCH GETTING STARTED. Operating buttons and display. Other symbols on the watch face

Input / Output to module

2. Unit Appearance. 3. Getting started: Open battery Cover (C2)

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Operation Guide Display Illumination. Modes and Display Screens. Hand Setting Mode. Button. Button (Mode switching) Button

Multifrequenz-Funk- Solarwerk

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

Operation Guide 3311/3356

Nixie Clock Type Nixie Maestro

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Conference Speaker Timing System. Operating Instruction Manual

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

WS-6002U Atomic Clock. Instruction Manual

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Power Supply and Watchdog Timer Monitoring Circuit ADM9690

Junghans MEGA J JUNGHANS DIE DEUTSCHE UHR

Jamar Smart Hand Dynamometer

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

/ /0708.qxd :27 Uhr S Collection Anytime

XTM72E & F Real-Time Clock Modules

Operations. BCU Operator Display BMTW-SVU02C-EN

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Nixie Clock Type Frank 3'

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Integrated Circuit for Musical Instrument Tuners

Master Time Clock MTC Users Manual

Rain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

AN1324 APPLICATION NOTE

ET BLU MIX RX-Condo-3

Digital Economy Seven Programmer

FRQM-2 Frequency Counter & RF Multimeter

LCD Thermometer / Clock S No. 1253

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Operation Guide 3459

Technical Description. Large Scale Display 4985

AL330B-DMB-A0 Digital LCD Display SOC Demo Board

Instruction Manual

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

MODEL ED32i TTL LINEAR ENCODER

RF4432 wireless transceiver module

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

REMOTE DISPLAY WIRELESS DECODER MK II

Digital Terrestrial Alignment & Installation Meter

OWL micro+ WIRELESS ELECTRICITY MONITOR

Style 5S Clock / Timer

Electronic 7 User Operating Instructions

Application Note. RTC Binary Counter An Introduction AN-CM-253

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Obsolete Product(s) - Obsolete Product(s)

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

LMH0344 3Gbps HD/SD SDI Adaptive Cable Equalizer

16-BIT LOAD CELL/DUAL STATUS INPUT

Uni700 LCD Controller

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Obsolete Product(s) - Obsolete Product(s) UM0223 User manual STEVAL-IFS001V1 evaluation kit with MEMS Introduction

VS-162 / VS-164. User Manual

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

QUAD THERMOCOUPLE INPUT

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Operation Guide 5554

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

DLP200M 2 Relay Module for Heating and Cooling Plants

C-net WIND. User s Guide

Single Axis Position Controller

Innovative Air Systems ABN When Calling For Support Quote:.doc

Nixie Clock Type IN-8 & NL840 Nixie'

ST625TX Digital Room Thermostat

SXT SXGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

SmartBox. User Manual. Turn your TV into a SmartTV! Plug n play. Wireless Dual Band

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Operation Guide 5395 (OC)

Junior Max (JR Max ) Controller

DM Segment Decoder Driver Latch with Constant Current Source Outputs

1. General Information:

Operation Guide 3464

Transmitter Interface Program

CINEGEARS MULTI AXIS FOLLOW FOCUS KIT V3 MANUAL BOOK Cine Gears INC. All Rights Reserved.

Redcare signal strength tester user manual.

Movement Caliber Cal.Z60

AY-U910 UHF Integrated Long-Range Reader Installation and User Manual

013-RD

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

MP-7424 Football Scoreboard with MP5000 Console

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

Operation Guide 5235/5414 (OC)

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

LCD Triplex Drive with COP820CJ

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

RF4432F27 wireless transceiver module

Transcription:

Analog/digital watch Multi frequency reception, 4 digit LCD, 3 hands Preliminary Specification Supplier: Asia Limited Unit 125, 1/F., Liven House, 61-63 King Yip Street, Kwun Tong, HK SAR Issued on: 20.12.2005 Issued by: Asia Limited Unit 125, 1/F., Liven House, 61-63 King Yip Street, Kwun Tong, HK SAR 1 of 15

1.0 Functional Overview Feature Motor Local Time display Date Day of the week Manual time setting Time Zone display Bond Option DST detection Radio controlled signal reception During reception Reception result indicator Low bat indication Back light Multi-frequency reception Analog module with electronic adjust Single second motor Hour:minute or second or date:day of week or time zone shown on LCD. Hands show second, minute and hour information. Can be shown on LCD together with day of the week Can be shown on LCD together with date Via electronic adjust seen on LCD Up to 24 different time zones can be manually adjusted. Time zone can be also shown on LCD Set default time zone upon power on; Set global (triple band) or local (dual or single) signal reception DST detection and update is default automatic for reception areas. For no radio control reception areas, DST is turned off by default. Can manually force DST on or off. Once DST active, icon will appear on LCD Auto reception maximum 3 times daily. Manual reception will only be performed if user manually activates RCC reception by button pressed. Signal to be received depends on time zone set Hands will move normally during auto and manual reception Hands will not move during reception after zero calibration Single button pressed show result on LCD display. If low batt detected, low bat icon will be displayed on LCD. No back light Only when time zone is set to Japan and Europe JPN : JJY40 JJY60 UK: MSF -> DCF EU: DCF -> MSF Sequence depends on previous reception result hereafter 2 of 15

2.0 LCD Display RC icon Signal Strength Indicator BSI DST icon (Active ON) COL2 COL1 DOT 15 Lo Batt icon (active LO) PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SEG 1 S3 S4 S5 S6 S7 S8 S9 0 COM0 COM0 BS3 1A BATT 2A RC -- 3A 3H DST 4A 4B COM1 COM1 B 1F 1B 2F 2B COL2 3F 3B 4F 4I 4J COM2 COM2 B 1E 1G 2E 2G COL1 3E 3G 4E 4G 4K COM3 COM3 -- 1D 1C 2D 2C DOT 3D 3C 4D 4L 4C 3 of 15

3.0 Button definition 12 Global Radio Controlled 9 3 6 4.0 Modes Overview pressed or AR = 1min Hour-Minute Mode Date-Month Mode >5s and after crown pulled out Zero calibration Mode LCD Display: 00:00 flashing Zone Mode Sec, week-day Mode > 2s Manual Reception Mode LCD Display: Normal Mode display & RC icon and signal quality indicator flashing AR = 1min > 2s Time Setting Mode LCD Display: Time Zone setting -> DST setting -> Hour setting -> Minute setting -> Year setting -> month setting -> date setting -> exit ( to switch item, to change value) 4 of 15

4.1 After reset / battery power on After hardware reset or battery power on, the user must set the hands to 0-position by operation as follows: Hardware Reset / Battery power on All hands do not move or Auto return time out = 1 min >2s Second hand move +1 second Continuous Adjust second hand at 64 pps ( max 12 hours) Single-step adjust second hand at 1 pps No Effect Start reception Second hand point to 12 o clock position until signal synchronised Reception failed Hands start time keeping from 0-position. Reception indicator = NG Reception OK Hands fast run to display received time, reception indicator = OK Automatically a receiving mode is started after the calibration mode is quitted after manually by pressing or by auto-return time out (= 1 minute ). After zero calibration, reception will synchronize minutes, seconds, and hours. If no was pressed after continuous fast adjust has started for 12 hours, the needles will stop by itself, and after 1 minute watch will start reception automatically. Bond Option for default time zone P11 P10 Default time zone Reception signal L L UTC + 9H (Japan) JJY40 -> JJY60 L H UTC 5H (USA-E) WWVB H L UTC + 0H (UK) MSF -> DCF H H UTC + 1H (EU) DCF -> MSF Note: For Japan, USA time bond option : show month-date format For other bond option : show date-month format 5 of 15

4.2 0-calibration The calibration mode can be started by pressing the button longer than 5 seconds. In 0 calibration, there are two different modes of adjustment: second hand fast adjust at 64 pps and minute adjust. Operation is as follows: Normal Time Operation Mode > 5s No Effect All hands move to 12 o clock position (second hand moves at 64 pps) After zero position in memory reached or pushed All hands stop or Auto return time out = 1min >2s Second hand move +1 second Continuous Adjust second hand at 64 pps (max 12 hours) Single-step adjust second hand at 1 pps No Effect Start reception Second hand stay at 12 o clock position until signal synchronised Reception failed Hands run to display previous time, reception indicator = NG Reception OK Hands run to display received time, reception indicator = OK Automatically a receiving mode is started after the calibration mode is quitted by autoreturn time out from any stage of the zero-calibration mode if no button is pressed for 1 minute. After zero calibration, reception will synchronize minutes, seconds, and hours. 6 of 15

4.3. Reception result indication Reception OK = Display RC icon : Reception NG = No indication = No RC icon displayed No RC icon displayed Any new reception will update the status of the reception result as follows: Possibilities for reception indication: Cases: Auto reception OK Auto reception NG - Auto reception OK Manual reception NG - Auto reception NG Auto reception OK - Auto reception NG Manual reception OK - Manual reception OK Auto reception OK - Manual reception OK Auto reception NG - Manual reception NG Auto reception OK - Manual reception NG Auto reception NG - Result: NG NG OK OK OK NG OK NG After exit time setting mode, reception indicator will show NG 7 of 15

4.4. RC Reception - During reception, RC icon will flash at 1 Hz and signal quality indicator will appear (when available) - if a signal is received the watch will be set to the new received time - if no signal is received after time out, the watch will continue running as old time and no RC icon and no waves will be displayed. - LCD will turn off RC icon and waves once reception is manually terminated. - LCD will turn on RC icon and waves once reception is succeeded. - Minute and hour hand (and second hand if any) will continue to move during reception. - During reception, the signal quality will be displayed on the LCD. No waves no signal available 1 wave weak signal available 2 waves good signal available, some interference 3 waves best signal available Reception sequence for JJY40 / JJY60 for first time reception is as diagram on right. Next dual reception (automatic or manual) starts from last successfully selected transmitter. If reception failed, next reception sequence will be reversed. Reception in JJY40 No 100ms DR in 2.5 mins Reception in JJY60 No 100ms DR in 2.5 mins 100ms DR in 2.5 mins 100ms DR in 2.5 mins Reception in JJY40 for 7 more mins Reception in JJY60 for 7 more mins Reception sequence for MSF/DCF is the same. First signal search depends on time zone selection and previous reception result. Stop reception 8 of 15

4.4.1 Manual Reception Manual reception can be started by pushing > 2s. Manual can also be cancelled by pushing >2s during reception. If any reception is cancelled, reception result will be NG. Signal to receive during manual reception depends on time zone set. For dual band time zones, this also depends on previous successful reception. 4.4.2 Automatic receiving mode The signal will be checked every night starting at a defined time (see table below) automatically. If the reception was not successful, the signal will be checked again at minute 00 of the next full hour up to 2 more times again. After the 3 rd failed reception, the watch will look again for signal in the next reception trial at the coming 3 am. Consecutive auto receptions are cancelled if the reception succeeded. AUTO RECEPTION START TIME Time Zone Auto reception start time at x o clock A.M. local time UTC +0h 3, 4, 5 UTC +1h 3, 4, 5 UTC +2h 3, 4, 5 UTC +3h 3, 4, 5 UTC +4h to UTC +7h No auto reception UTC + 8 2,3,4 UTC + 9 2, 3, 4 UTC +10h to UTC + 12h No auto reception UTC -12h to UTC -10h No auto reception UTC -9h to UTC -5h 2, 3, 4 UTC -4h to UTC -1h No auto reception With press of button > 2s, auto reception can be cancelled and the watch will display the pre-adjusted time. 9 of 15

4.5 Manual time setting Items that can be set by the manual time setting mode includes: Time Zone : 24 hour time zone from UTC+12h to UTC -12h DST control : auto (from RCC signal), always on, always off Hour : 0 to 23 Minute : 1 to 59 Year : 01 to 98 month : 1 to 12 date : 1 to 31 (28, 29 or 30 for some months) During time setting mode, the second hand will stop until exit setting mode or auto return time out after 1 minute of no action in setting mode, then second hand will fast move to catch up time. Within setting mode, press to make changes or increment, press to switch to next item and confirm present setting. Hour-Minute Mode Date-Month Mode Zone Mode Sec, DOW Mode > 2s Time Zone DST Setting Date Hour Month Minute Year 10 of 15

4.5.1 DST setting Default DST setting depends on the adjusted time zone. If time zone is changed, the DST setting will also change according to the table in the next section. Within a certain time zone, the user can also change the DST setting as below, once changed, the DST setting will be set according to the user s change until time zone is being modified again. For auto reception available areas: DST ON AUTO DST OFF (DST is forced on) (DST according to RC signal s DST bits) (DST is forced off) When DST is set to ON / OFF: - if signal synchronised is DCF / MSF / JJY40 / JJY60, the watch will detect the signal DST status and change DST display according to signal. At this time, the DST setting will also be reverted to AUTO. - if signal synchronised is WWVB, the watch will NOT detect the signal DST status and time and DST display will not change until time setting (including date, time zone, DST setting) is altered or if another signal is received. For non-reception areas (refer to section 4.5.2): Default setting of DST is off, but user can change this setting as follows: DST ON DST OFF (DST is enabled permanently until time zone change or user change of DST setting) (DST is disabled permanently until time zone change or user change of DST setting) The DST icon shows whether DST is active at the moment. Whether DST control is forced off, forced on or auto is shown in setting mode. 11 of 15

4.5.2 Time Zone setting Time Zone Symbol on LCD display Default DST setting P12 = H P12 = L P11 = L P10 = L Radio Control reception Signal P12 = L P12 = L P11 = L P11 = H P10 = H P10 = L P12 = L P11 = H P10 = H UTC -12h - 12H OFF OFF OFF OFF OFF OFF UTC-11h - 11H OFF OFF OFF OFF OFF OFF UTC -10h - 10H OFF OFF OFF OFF OFF OFF UTC -9h - 09H AUTO WWVB OFF WWVB OFF OFF UTC - 8h US-P AUTO WWVB OFF WWVB OFF OFF UTC -7h US-M AUTO WWVB OFF WWVB OFF OFF UTC -6h US-C AUTO WWVB OFF WWVB OFF OFF UTC -5h US-E AUTO WWVB OFF WWVB OFF OFF -UTC-4h - 04H OFF OFF OFF OFF OFF OFF UTC -3h - 03H OFF OFF OFF OFF OFF OFF UTC -2h - 02H OFF OFF OFF OFF OFF OFF UTC -1h - 01H OFF OFF OFF OFF OFF OFF UTC UK AUTO MSF->DCF OFF OFF MSF->DCF MSF->DCF UTC +1h EU AUTO DCF->MSF OFF OFF DCF->MSF DCF->MSF UTC +2h 2H AUTO DCF OFF OFF OFF DCF UTC +3h 3H OFF OFF OFF OFF OFF OFF UTC +4h 4H OFF OFF OFF OFF OFF OFF UTC +5h 5H OFF OFF OFF OFF OFF OFF UTC +6h 6H OFF OFF OFF OFF OFF OFF UTC +7h 7H OFF OFF OFF OFF OFF OFF UTC +8h CN OFF J6 OFF OFF OFF OFF UTC +9h JP OFF J4 -> J6 J4 -> J6 OFF OFF OFF UTC +10h 10H OFF OFF OFF OFF OFF OFF UTC +11h 11H OFF OFF OFF OFF OFF OFF UTC +12h 12H OFF OFF OFF OFF OFF OFF After a different time zone is set, the default DST setting and signal to be received may change accordingly. 12 of 15

4.6 Hands adjustment There are 4 cases that the 3-hands of the watch will fast move to adjust: 1) After successful reception of signal and time is different to existing time 2) After change of time zone 3) After change of DST setting 4) During zero calibration During fast adjustment of watch hands, manual reception function will be disabled. Settings adjustment is still possible, once in setting mode, hands will stop until exit setting mode, then it will resume fast run to set time. If auto reception time is reached during hands adjustment, the reception will be postponed until hands finished adjustment and restarted at the next second 00 after adjustment. The worst case for hands adjustment is when hands have to move 12 hours. Fast movement of second hand is at 64 Hz. Therefore worst case duration for hands adjustment is around 11 minutes. 4.7 Low battery indication If battery voltage level falls below 2.3V, the low batt icon battery is being replaced. will be turned on, until the 13 of 15

4.8 Antenna Tuning Mode After reset, LCD will show full screen display for 3 seconds: During full screen display, if is pushed once, watch will enter antenna tuning mode, all hands will not move and user can select between different reception signals to antenna frequency: 1) JP 40 : JJY40 2) JP 60 : JJY60 3) US : WWVB 4) UK : MSF 5) EU : DCF The corresponding signal will appear and flash on the LCD during selection, and by pressing, signals can be scrolled through. By pressing, the flashing signal will be selected. Upon selection, the signal abbreviation will stop flashing and from hereon, the CME8000 will be set to receive the chosen the signal and analog signal output will appear on the TEST pin if 100nF is attached to the pin connected to GND. 3 secs Show BSI and flashing antenna icon when receiving 14 of 15

Disclaimer of Warranty Information furnished is believed to be accurate and reliable. However assumes no responsibility, neither for the consequences of use of such information nor for any infringement of patents or other rights of third parties, which may result from its use. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. products are not authorized for use as critical components in life support devices without express written approval of. Note It is not given warranty that the declared circuits, devices, facilities, components, assembly groups or treatments included herein are free from legal claims of third parties. The declared data are serving only to description of product. They are not guaranteed properties as defined by law. The examples are given without obligation and cannot give rise to any liability. Reprinting this data sheet - or parts of it - is only allowed with a license of the publisher. reserves the right to make changes on this specification without notice at any time. Asia Ltd Technology Ltd (Shenzhen) Unit 125, 1/F., Room 31C, Block A, Liven House, World Finance Centre, 61-63 King Yip Street, No. 4003 Shennan East Road, Kwun Tong, Kowloon, HK SAR Luohu, Shenzhen, PR China Tel.: +852-2798-5182 Tel:+86-755-25181858 Fax: +852-2798-5379 Fax:+86-755-25181859 e-mail: inquiry@c-max.com.hk 15 of 15