POLARIZED FIBER OPTIC SOURCE

Similar documents
OPTICAL POWER METER WITH SMART DETECTOR HEAD

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Lensed Fibers & Tapered Ends Description:

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

OZ Optics Limited. Polarization Maintaining Components. June 2018

Optical Component Environmental Test System

Agilent 81600B Tunable Laser Source Family

OpticalProducts. Illuminating Your Network. Testing the World s Networks

SLD. Board FC/APC Connector. TEC Control. Board. Control Circuits. Control interface DB9 (Female)

OP750. Multichannel Source Instruction Manual

Light Source. Specification & User Manual

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Fiber Type Core/Cladding (um) Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

PV Series 850 nm VCSELs. Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

HP 70950B OPTICAL SPECTRUM ANALYZER

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

ModBox-850nm-NRZ-series

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

Datasheet: CertiFiber Pro Optical Loss Test Set

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

FiberLink 3350 Series

Benchtop/Rackmount Programmable Switches. Key Features & Benefits. SB/SC/SCG Series. Applications INSTRUMENTATION CATALOGUE - 73

OSICS 8-Channel Modular Platform for DWDM Testing

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

ModBox-CBand-NRZ series C-Band, 28 Gb/s, 44 Gb/s, 50 Gb/s Reference Transmitters

Datasheet: SimpliFiber Pro

PlexBright LED Optogenetic Stimulation System

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

PONA 3000 Series Erbium Doped Fiber Amplifier

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

LIIN-25 FO Pigtail FC (0.9mm)

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

OPTICAL FIBERCONNECT. Version 3.

SatellitePlus Model OLAT/OLAR. Advanced L-Band Series. 10-4,000 MHz OPERATING MANUAL

Product Operation Manual

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Miniature, Ruggedized 20 GHz RF over Fiber Transmitter

User's Guide to the PROLITE-30B

MAP Optical Power Meter Module (mopm-b1)

PONA 3000 Series Erbium Doped Fiber Amplifier

OFI Optical Fiber Identifier User s Guide

FiberLink 3500 Series Transceivers

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Fiber-optic Video Format Converters DATA SHEET

MAFA 5000 Series Erbium Doped Fiber Preamplifier

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

PM Couplers (Polarization Maintaining Couplers)

ViaLiteHD Fibre Optic Green OEM Link Modules

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

FIBER OPTIC POSITRONIC INDUSTRIES. Interconnection Systems. RoHS Compliant Options Available! Catalog A-011 Rev.

1623A/B O-Band DWDM DFB Laser Module

P-AD ADAPTORS. Features: Low insertion loss Low back reflection loss Easy to handle Environmentally stable

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Fiber-coupled light sources

1 Gang-sized Multi-format video to Optical DVI Converter, MVDF DATA SHEET

Fiber Meter. Specification & User Manual

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

ST800K-U Optical Power Meter. User Manual V1.0

SECTION 4 TABLE OF CONTENTS

Agilent 8153A Lightwave Multimeter Technical Specifications

Optical Communications Mainframe - Laser Transmitter Module

Datasheet: MultiFiber Pro Update

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MXAN-LN series 1550 nm band Analog Intensity Modulators

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Advanced Test Equipment Rentals ATEC (2832)

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

L-Band Fiber Optic Link

LIST. Digital Video Transmitter and Receiver 11

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

MXAN-LN series 1550 nm band Analog Intensity Modulators

10Gbps SFP+ Optical Transceiver, 10km Reach

ED5229GT-E Series. Page 1 of 8

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Model 4700 Photodiode Characterizer

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

about dktcomega DKTCOMEGA s mission

Versiv makes you money every time you use it.

Datasheet: CertiFiber Pro Optical Loss Test Set

FiberLink 3355 Series

Click to edit Master title style

OTS-300 Express Series Power Meters/Sources and Testers

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

TLB-2020-L. Full L Band Tunable CW Laser. 20 mw Full Band Tunable CW Laser Butterfly. Features. Applications. Benefits

HI-DEX PRODUCT SET DATASHEET

RGB COMBINERS. 2.0 mm Narrow Key FC/PC or FC/APC Termination Excellent for Confocal. Ø900 µm Loose Hytrel Tube with the wavelength Laser Sources

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

Transcription:

219 Westbrook Rd, Ottawa, ON, Canada, K0A 1L0 Toll Free: 1-800-361-5415 Tel:(613) 831-0981 Fax:(613) 836-5089 E-mail: sales@ozoptics.com Features: High polarization extinction ratio (up to 40 db) Stable output Wide range of available wavelengths Rugged and compact design Wide range of connector receptacles available Optional high power versions Optional adjustable output power Applications: Extinction ratio measurements Polarization Dependent Loss (PDL) measurements Product manufacturing and quality control Product Description: POLARIZED FIBER OPTIC SOURCE Receptacle Style Polarized Fiber Optic Source With Rotatable Polarizer OZ Optics produces Polarized Fiber Optic Sources (PFOSS) in a variety of wavelengths. Sources are available in three versions. A receptacle version is available with the polarization axis aligned with the keyway on the receptacle. A second receptacle style version is available with a rotatable polarizer, allowing one to adjust the polarization axis to any desired angle. Finally, a pigtail style version has a polarization maintaining fiber attached, with the output polarization aligned with the slow axis of the fiber (see the Fiber Optic Laser Diode Source data sheet for details). As an option, OZ Optics can include a blocking style optical attenuator to manually change the output. Unlike electrical systems, this method of power control does not affect the spectral properties of the laser diode output. This ensures more repeatable results. While the PFOSS design is quite stable for standard measurements, sometimes reflections or temperature changes can affect the output power and wavelength for applications where stability is critical. OZ Optics recommends using angled connectors and receptacles for optimum stability. Highly Stable Polarized Fiber Optic Laser Sources (HIPFOSS), using Peltier coolers and isolators are also available. See the Highly Stable Polarized Source data sheet for details. Figure 1: Receptacle Style Polarized Fiber Optic Source With Rotatable Polarizer DTS0073 OZ Optics reserves the right to change any specifications without prior notice. 04/02 1

Ordering Information For Standard Parts: 8695 PFOSS-02-3-1550-1-ER=35 1550 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra FC receptacle and rotatable polarizer achieving up to 35 db extinction ratio 11378 PFOSS-02-3-1550-1-ER=40 1550 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra receptacle and rotatable polarizer achieving up to 40 db extinction ratio 13036 PFOSS-02-3-1310-1-ER=35 1310 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra FC/PC receptacle and rotatable polarizer achieving up to 35 db extinction ratio 13507 PFOSS-02-3-1310-1-ER=40 1310 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra FC/PC receptacle and rotatable polarizer achieving up to 40 db extinction ratio 9036 PFOSS-01-3-1550-1-ER=35 1550 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra FC/PC receptacle and fixed polarizer achieving up to 35 db extinction ratio 2737 POWER CORD - EUROPE European power cord 2736 POWER CORD - UK UK power cord 13390 PMJ-3U3U-1550-8/125-1-1-1-ER=30-G Master patchcord, Ultra FC/PC to Ultra FC/PC, 8/125um PM 1550nm fiber, 0.9mm OD jacketed, 1 meter long with connectors aligned and locked to the slow axis, ER=30dB minimum 11998 ER-100-1290/1650-ER=40 Fiber Optic Polarization Extinction Ratio Meter for wavelengths from 1290 nm to 1650 nm. ER = 40dB 13440 ER-23-1290/1650-ER=40 Super/Ultra FC removable receptacle for ER Meter adapted for wavelengths from 1290 nm to 1650 nm. ER = 40dB Standard Product Specifications 1 : Part number PFOSS-02-3-1550-1-ER=40 PFOSS-01-3-1550-1-ER=35 PFOSS-02-3-1550-1-ER=35 PFOSS-02-3-1310-1-ER=35 Bar Code # 11378 9036 8695 13036 Laser Type 2 Fabry-Perot Laser Central Wavelength 3 1550 nm ± 20 nm 1310 nm ± 20 nm Extinction Ratio 40dB 35dB Output Power 4 1 mw Polarizer Type Rotatable Fixed Rotatable Spectral Bandwidth 5 Short Term Stability 6 Long Term Stability 7 Connector Type < 5 nm ±0.05 db ±0.1 db Standard, Super, Ultra NTT-FC/PC receptacle Power Variation induced by rotatable polarizer Input Voltage Dimensions Weight Operating Temperature Storage Temperature Relative Humidity < 0.25 db N/A < 0.25 db Universal 110/220 Volt AC to DC adapter 60 x 90 x 190 mm 500 gr 0 to 40 C -20 to 60 C < 90% RH non condensing 1 Reference condition: 23 C ambient temperature after 30 minutes warm-up period 2 DFB lasers are also available as a custom order. 3 Depends on laser diode manufacturer and temperature operation. 4 For higher output power we recommend ordering a HIPFOSS to improve wavelength and power stability. 5 Measured at Full Width Half Maximum 6 15 minutes at constant temperature and after 30 minutes warm-up period 7 6 hours at constant temperature and after 30 minutes warm-up period 2

Ordering Examples For Standard Parts: A European fiber optic manufacturer wants to test the quality of their polarization maintaining jumpers at 1550nm and 1310nm. They need to order the following parts: 13507 PFOSS-02-3-1310-1-ER=40 1310 nm, 1 mw Polarized Fiber Optic Source with a Super/Ultra FC/PC receptacle and rotatable polarizer achieving up to 40 db extinction ratio 8695 PFOSS-02-3-1550-1-ER=40 1550 nm, 1 mw Polarized Fiber Optics Source with a Super/Ultra FC/PC receptacle and rotatable polarizer achieving up to 40 db extinction ratio 11998 ER-100-1290/1650-ER=40 Fiber Optic Polarization Extinction Ratio Meter. ER= 40dB for 1290 nm to 1650 nm and ER = 30dB for 850 nm to 1290 nm 13440 ER-23-1230/1650-ER-40 Super/Ultra FC removable receptacle for ER meter for wavelengths from 1280 nm to 1650 nm. ER=40. 13390 PMJ-3U3U-1550-8/125-1-1-1-ER=30-G Master Patchcord, Ultra FC/PC to Ultra FC/PC, 8/125um PM 1550nm fiber, 0.9mm OD jacketed, 1 meter long with connectors aligned and locked to the slow axis ER=30dB minimum 2737 POWER CORD - EUROPE European power cord (order one cord for each source, and for the ER meter (Total = 3 pieces) Ordering Information For Custom Parts: OZ Optics welcomes the opportunity to provide custom designed products to meet your application needs. As with most manufacturers, customized products do take additional effort so please expect some differences in the pricing compared to our standard parts list. In particular, we will need additional time to prepare a comprehensive quotation, and lead times will be longer than normal. In most cases non-recurring engineering (NRE) charges, lot charges, and a 1 piece minimum order will be necessary. These points will be carefully explained in your quotation, so your decision will be as well-informed as possible. We strongly recommend buying our standard products. Questionnaire For Custom Parts: 1. What wavelength do you need? 2. What connector type are you using? 3. How much optical power do you need launched into your fiber? 4. What should be the minimum polarization extinction ratio of the source? 5. Do you want a fixed or rotatable polarizer? Receptacle Style PFOSS: A = Source type: 1 for fixed polarization 2 for Rotable Polarization X = Connector code : 3= Standard, Super or Ultra NTT-FC/PC receptacle 3A= Angled NTT- FC/PC SC=SC SCA=Angled SC 8=AT&T-ST MU=MU type connector LC=LC type connector 1.25U=Universal Receptacle for 1.25mm OD connector ferrules (LC, MU) 2.5U=Universal Receptacle for 2.5mm OD connector ferrules (ST, FC, SC) Notes: Ordering Examples For Custom Parts: PFOSS-0A-X-W-P (-ER=YY) YY = Extinction ratio. Add this only for ER>30dB. Specify 35 or 40dB. If not specified, the extinction ratio is greater than or equal to 30dB. ER=35dB or 40dB is only available for 980nm, 1064nm, 1290-1625nm. P = Output power, in mw 1mW is standard 1. For Highly Stable Polarized Sources (HIPFOSS) which include an isolator and Peltier cooler circuit please refer to the Highly Stable Polarized Source data sheet 2. Add -BL to the part number to have blocking style attenuator added to the PFOSS 3. Add -ISOL to the part number for an isolator. For wavelengths less than 1290nm, order a HIPFOSS instead W = Wavelength in nm: 635, 650, 685, 780, 830, 850, 980, 1064, 1310,1480,1550,1625 A European manufacturer of fiber optic circulators wants to test the extinction ratio of their polarization maintaining jumpers at 980nm prior to pigtailing them to their integrated waveguides. They need to order the following parts: N/A PFOSS-02-3A-980-2- ER=40 980 nm, 2 mw Polarized Fiber Optic Source with an angled FC receptacle, rotatable polarizer, achieving over 40dB extinction ratio. N/A ER-100-980-ER=40 980 nm, Fiber Optic Polarization Extinction Ratio Meter. ER = 40dB N/A ER-23A-980-ER=40 980nm, Angled FC Removable Receptacle for ER Meter. ER = 40dB N/A PMJ-3A3A-980-6/125-1-1-1-ER=30-G Master patchcord, Angle FC/PC to Angle FC/PC, 6/125um PM 980nm fiber, 0.9 mm OD jacketed, 1 meter long with connectors aligned and locked to the slow axis ER=30dB minimum 2737 POWER CORD - EUROPE European power cord. Order one for the source and one for the meter 3

Power Drift (db) Short Term Stability of 1550nm PFOSS 0.05 0.03 0.01-0.01-0.03-0.05 0 0.1 0.2 0.3 0.4 0.5 Figure 2. PFOSS Stability Test Time (hours) 0.1 Long Term Stability Of 1550nm PFOSS Power Drift (db) 0.05 0-0.05-0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Figure 3. PFOSS Stability Test Time (hours) Frequently Asked Questions (FAQs): Q: My source has a receptacle for FC connectors. Will it work with connectors that have either FC/PC finish or FC/APC finish? A: Q: A: If you connect a fiber with an angled FC (APC) connector to your source, you should expect a significant drop in the output power. This is because the source is designed to focus light to a point in space where the tip of the fiber is supposed to be. A stop inside the receptacle stops the ferrule at the correct distance. However, because the end of the connector ferrule is angled, the fiber will not be located in the correct position.as a result the light will not be correctly focused onto the fiber, and more of the light will go into the cladding instead. While this will reduce the overall power, if the fiber is long enough to attenuate all the cladding modes, the output should remain stable during operation. Short fibers, especially those less than one meter long, will likely transmit some cladding modes, which will show up as an unstable output signal. I purchased a source with a receptacle for FC/APC connectors, and I am using a patchcord with an FC/APC connector on the end, but I still don't seem to get the same power as listed on your test report. Why? Not all APC connectors are the same. The angle at which they are polished can vary by ±0.5 degrees. The raduis at which they are polished can vary from 5 to 12mm. The tip of the connector may be cone shaped, or have straight side walls. Because of these variations, the position of the fiber core within the receptacle may vary from fiber to fiber. This will in turn reduce your coupling efficiency. Q: Do you offer 1.25mm and 2.5mm ID universal adaptors for your sources? A: We can, but we do not recommend them. Universal adaptors do not have a retaining mechanism, so the fiber can fall out if you do not hold it in place. In addition, the lack of a retaining mechanism will cause the coupled power from the source to be unstable. Universal receptacles can be used in applications where you are not concerned with the power stability, such as visible sources for fault location, or PFOSS or HIPFOSS polarized sources for PM fiber patchcords. Q: What is the maximum output power of the PFOSS? A: The maximum output power is 1 mw for the standard PFOSS. For higher power sources, refer to the Highly Stable Polarized Source data sheet. 4

Frequently Asked Questions (FAQs) Continued: Q: Does OZ Optics use DFB laser diodes in their sources? A: The standard models use a Fabry-Perot (FP) laser diode. Distributed Feedback (DFB) laser diodes feature single wavelength output. These diodes are available as an option. However they are more expensive, and are not offered at all wavelengths. Application Notes: Using Bare Fibers With PFOSS And HIPFOSS Sources In many applications it is necessary to connect fibers that do not have a connector attached (bare fiber) to an optical source. With the receptacle style polarized sources the easiest way to do this is with an FC bare fiber adapter (Part number BARE-03-126, Bar Code #1816). These adaptors are essentially an inexpensive way to temporarily put an FC connector onto the end of a fiber. To use a bare fiber adapter, one strips, cleans and cleaves the fiber end to be tested, and inserts it into the rear of the adapter. The fiber is pushed in until it is flush with the end of the ferrule, and then a clamp holds the fiber in place. The fiber can then be inserted into the receptacle like a standard FC connector. Using this technique, expect coupling efficiencies to be somewhat lower. Often coupling efficiencies are only 25% of the optimum value, although this depends somewhat on the skill of the operator. This should not affect extinction ratio measurements. Also, since the fiber is not aligned with respect to the key on the connector, the polarization angle from the source may have to be adjusted to line it up with the fiber. Finally, never use a bare fiber adaptor to connect one fiber to another fiber, or to connect a fiber to a source or detector that has a fiber stub inside. Doing so will likely scratch or damage the fiber inside the source or detector, leading to expensive repairs. 5