WALKING A TIGHT ROPE

Similar documents
MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV Ph: cox.net 20 December 2018

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

C A R G O C O N T R O L. By Fritz Dahlin

WIRE AND CABLE FIRE TESTS

UNOLS Wire Pool Database. Presented by Rick Trask Woods Hole Oceanographic Institution

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

World s Thinnest Flat Panel Mounting Solutions

Aerial Cable Installation Best Practices

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

Lashing Rods NOMENCLATURE GENERAL RECOMMENDATIONS. C = D x m = D x.666. m = D x.414. m = D x.483. C = (D + m) x.850. Length.

SCHEDA TECNICA. Amarro per cavi 13,5mm Amarro per cavi 16,5mm. MS217F00 Amarro per cavi 13,5mm MS218F00 Amarro per cavi 16,5mm

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

TECHNICAL SPECIFICATION

White Paper. Discone Antenna Design

E X P E R I M E N T 1

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Simple and highly effective technology to communicate your brand s distinctive character

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

LabView Exercises: Part II

RIPPLE TANK - projection, with strobe & kit

GS122-2L. About the speakers:

Commissioning Lock Issues:

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

Monitoring Of Drag Anchor Embedment Parameters. Roderick Ruinen, Vryhof Anchors BV

Personal Protective Equipment Wear nitrile gloves, lab coat, and safety glasses as a minimum protection, unless otherwise indicated.

Distributed Design Series

Aerial Installation Guidelines for Fiber Optic Cable

TECHNICAL INFORMATION

THE OPERATION OF A CATHODE RAY TUBE

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Tension Electric Screen. CineTension Series. Users Guide USER S GUIDE. Rev. 1.1

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

REMOTE SOFTWARE USER GUIDE V1.0

TLS RGBW CUT SHEET DESCRIPTION FEATURES

TUBE AERATION NEXT GENERATION 9000 & INSTALLATION MANUAL

SPECIFICATION. Spec No : VSS-1402-CS603B

XCELLENCE SERIES X-15LTP

Bolt-A-Plate. We Support You.

TV Lift System Model CL-65 Installation Instructions

SLiC Fiber Aerial Closure System

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

SHOOT THE TARGET ACCESSORY

THE OPERATION OF A CATHODE RAY TUBE

Adapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication

NaviPac Cable Laying Utilities. Author : Ole Kristensen Company : EIVA a/s Date: April 2012

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Bridges and Arches. Authors: André Holleman (Bonhoeffer college, teacher in research at the AMSTEL Institute) André Heck (AMSTEL Institute)

All-Glass Sliding-System SF20

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Flygt Submersible Motor Cables

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Automated TV Wall Mount

SMART CLASSix 24/48 UTP Patch Panels -

GENUINE PARTS ! CAUTION

All-Glass Sliding-System SF20

The Grey Nomad s Guide to Satellite Dish Setup Procedures.

Support Frame STB Technical Instruction Manual

ROTARY ENCODER SELECTION. A Step by Step Guide

ELLIPTICAL ANTENNA E0851B11

dbtechnologies QUICK REFERENCE

TruePlate Structural Plate

Adjustable Mast Bracket Installation Guide

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

VideoClock. Quick Start

How Close Can They be Stacked? By K0CQ. How close can yagis for harmonically related bands be stacked? What are the consequences of close stacking?

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

HighBand 25. TrueNet Category 6 Solutions

Con o t n e t n e t n s t

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

VISION M OU NT. Model MF215-B1 shown

Smart Products. Ingenious Solutions.

Assembly and Operating Instructions

Innovation & Excellence. Index. Index. Innovation & Excellence. Introduction 4-5. Our Features 6-7. Applications

WIRE CABLES PULL CABLES WR CONTROLS FLEXBALL ITALIANA CONDUIT FOR PULL CABLES WIRE FOR PULL CABLES

DLMP-45/45R Installation Instructions

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

Elite Silvermax Series

A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Cable Installation Tips

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

Cable Installation Tips

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

Service manual Cantano W/T

Music-Visualization and Motion-Controlled LED Cube

Building a MidiBox LCD Cable

Part 4 High Voltage Overhead DISTRIBUTION CONSTRUCTION STANDARDS HANDBOOK

Practice, Practice, Practice Using Prototek Digital Receivers

LIVERPOOL TLX43. Custom-Engineered Drivers

NuQ102 ## ## for FOH, sidefill and delay line loudspeakers, and is an exceptional choice for wedge monitoring applications.

THE CABLE TRAY SYSTEM

Wabash Bridge Competition. Bridge Engineering. Todd Wilson, B.S., E.I.T. Traffic Engineer - DMJM Harris

PULL SUPPORT PROTECT CONNECT

Transcription:

MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV 89014 Ph: 702 547 1564 kent.goodman @ cox.net www.maximumreach.com 07 August 2013 WALKING A TIGHT ROPE Last month, I saw a video where Nik Wallenda walked a 2 diameter wire rope 1,400 long that was 1,500 above the stream bed of a gorge near the Grand Canyon. To view the video, put your cursor on the link below, press Ctrl and then click on the link to watch Nik walking the tight rope! http://www.cbsnews.com/video/watch/?id=50149503n I was intrigued, not so much by his walking ability, but by the layout of the cable across the canyon. I felt that this would be a practical application so I decided to use the Guyline Properties Program on my website and see if I could duplicate the configuration of the cable using the information above. I couldn t tell in the video what kind of anchorage was used, but rock bolts and strand jacks would work very well in a remote area. Thinking that it would be easier to walk if there wasn t too much sag in the cable and that it would be better to walk down hill if possible, I decided to limit the sag to about 25 and place the upper support 30 above the lower support. Using 80,000 lbs (36.36 Te) of horizontal tension in the cable provided a sag of 22.64. In the video, it looked like the cable sloped somewhat from the upper support down to the bottom support. Note in the guyline properties program print outs below that if the support on the starting side of the canyon is 30 higher than the support on the far side of the canyon (the end of walk side), that the cable is almost all downhill with a small climb up at the end of the walk. Piece of cake. INPUT DATA

OUTPUT DATA

By using my program and the input data and using X at 100 increments, I found that for a: X = 100 Y = -3.8 X = 200 Y = -6.8 X = 300 Y = -8.8 X = 400 Y = -9.9 X = 500 Y = 10.1 X = 600 Y = -9.3 X = 700 Y = -7.6 X = 800 Y = -5.1 X = 900 Y = -1.5 X = 950 Y = O.6 X = 1000 Y = 2.9 X = 1100 Y = 8.3 X = 1200 Y = 14.6 X = 1300 Y = 21.9 X = 1400 Y = 30.0 By plotting these values, they show that at the lower support, the cable starts off sloping down at an angle of 2.48 degrees, At about 500 it bottoms out at 10 below the lower support and starts sloping up. At about 950 it crosses the level line from the bottom support. From there it continues to slope up until it is 30 above the lower support, ie, to the level of the top support.

I also made a run with the upper support 60 above the lower support. With the horizontal tension still at 80,000 lbs., the sag was about the same but the angle at the bottom was reduced to -1.25 degrees. So the cable was pretty much downhill all the way from the upper support. The guyline properties program is used to find the properties of a cable hanging under its own weight as a catenary and does not take into account a load placed on it. I used it for the above example as the weight of a 200 lb. walker would not increase the tension in the cable very much due to the flatness of the cable and high tension required to maintain a 22.6 sag. But a 200 lb. load would increase the tension somewhat. The following steps show how to calculate how much the increase in tension would be by keeping the sag the same as in the printout above. This information came from the United States Steel Handbook, page 46, shown below.

Go to the following website to purchase a copy of this handbook: http://www.ebay.com/itm/uss-tiger-brand-wire-rope-engineering-hand- BOOK-1946-/370622836420

Reference the drawing and formulas above where the cable has an inclined span and a single load at the center. The tension in the cable is greatest when the load is at the center. Also, the tension in cable is greatest at the upper support. Notice that in the drawing that the horizontal reference line is taken at the upper support, whereas in my sketch it is taken at the lower support. The horizontal tension T in a cable with a 200 lb. load hanging at the center of the span is: T = S(2*G+w*S)/(8*Yc-4*H) where S = the 1,400 span G = the 200 lb. load w = 7.39 lb./ft of 2 ϕ cable weight Yc = the 37.6 vertical distance from the lower support to the upper support + the vertical distance from the lower support to a point down on the cable at the center of the span which = 30 between supports + 7.6 from the printout above where X = 700. H = the 30 vertical distance between the lower and upper supports = 1,400(2*200 + 7.39*1,400)/(8*37.6 4*30) = 83,210 lbs. The angle B1 at the upper support is: Tan (B1) = (G + ws)/2*/t + H/S = (200 + 7.9*1,400)/2*83,210 + 30/1,400 = 0.0848 B1 = 4.85 This closely matches the 4.93 found in the printout above The tension T1 in cable at the upper support is: T1 = T*Sec(B1) = T/Cos(B1) = 83,509 lbs. So, the increase in tension due to a 200 lb. walker is 83,509 80,296 = 3,213 lbs. The safe working load (SWl) of a 2 ϕ EIPS wire rope is: Breaking strength of a 2 ϕ EIPS wire rope = 396,000 lbs. The safety factor for a stationary wire rope ie, a guyline = 3.0:1 The safety factor for a running wire rope, ie, a hoist line = 3.5:1 So being conservative and using the 3.5:1 S.F. The SWL of the wire rope is 396,000/3.5 113,000 lbs. 113,000 lbs. > 83,509 lbs. === GOOD

It is not clear in the video how the cable is tied off or connected to the anchorage, but the worst case for a reduction in SWL for say using cable clamps would be 0.80 and a best case of 1.0 using spelter sockets. 113,000 lbs. * 0.80 90,000 lbs. ==== STILL GOOD END OF PRESENTATION