Quickly converts glass slides into high-definition digital data by high-speed scanning!

Similar documents
High-speed, high-resolution digital slide scanner with network features

All-in-one solutions For applications with imaging challenges, we offer a wide range of TDI solutions.

UV-LED MODULE. UV Irradiation Intensity Distribution Graphs

Short wavelength type APD. Effective photosensitive area (mm) Effective photosensitive area size* 2

Low bias operation, for 800 nm band

Optics modules. Absorbance measurement module with built-in photodiode array, optical elements, current-tovoltage. C13398 series.

Photosensitive area size (mm) Reverse voltage VR max (V) R to +60

Application OCT. Dimensions (mm) Weight (g) Operating temperature* 1 Storage temperature* 1 λ=1.55 μm (V) (mw)

Effective photosensitive area. Photosensitive area size

Photon counting module

Peak emission wavelength: 3.9 μm

MPPC modules. MPPC array modules for very-low-level light detection, 16 ch analog output. C13368/C13369 series (Analog output type)

Driver circuit for CCD linear image sensor

Driver circuit for InGaAs linear image sensor

InGaAs multichannel detector head

InAsSb photovoltaic detector

Effective photosensitive area (mm)

Effective photosensitive* 2 area size. Storage temperature Tstg (mm) ( C) ( C) S φ0.2 φ0.5 S φ to to +100 S9075

Driver circuit for InGaAs linear image sensor

Effective photosensitive area (mm) Photosensitive area size

Parameter Symbol Specification Unit Photosensitive area - ɸ0.8 mm Package mm

Power supply for MPPC

Driver circuits for CCD image sensor

Peak emission wavelength: 4.3 μm

Driver circuit for CMOS linear image sensor

InAsSb photovoltaic detectors

Accessories for infrared detector

Peak sensitivity wavelength λp (nm) Photosensitive area (mm)

Driver circuit for CCD linear image sensor

MPPC (Multi-Pixel Photon Counter)

Signal processing circuit for 2-D PSD

MPPC (multi-pixel photon counter)

Signal processing circuit for 1-D PSD

Driver circuit for MPPC

RGB color sensor. Effective photosensitive area. Green, Red: 2.25 Blue : 4.5

These Si photodiodes have sensitivity in the UV to near IR range. They are suitable for low-light-level detection in analysis and the like.

Si PIN photodiodes. High-speed detectors with plastic package. Structure. Absolute maximum ratings

Infrared detector modules with preamp

Parameter Specification Unit Photosensitive area mm Package Glass epoxy - Seal material Silicone resin -

Photosensitive area (mm) 4 4. Peak sensitivity wavelength (nm) Supply voltage Dark state. Max. Vcc max. Tstg Min. Max. (ma) (V)

Photo IC diode. Plastic package shaped the same as metal package. S SB. Features. Applications

Si PIN photodiodes. High-speed detectors with plastic package. Structure. Absolute maximum ratings

Power supply for MPPC

APD modules. Operates an APD with single 5 V supply (standard type, short-wavelength type) C12702 series.

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram

Photosensor with front-end IC

M=100, RL=50 Ω λ=800 nm, -3 db

Reverse voltage VR max. Electrical and optical characteristics (Typ. Ta=25 C, unless otherwise noted) Short. Temp. S coefficient (A/W) of

Signal processing circuit for 2-D PSD

Driver circuit for CMOS linear image sensor

Signal processing circuit for 1-D PSD

16-element Si photodiode arrays

Suppressed IR sensitivity

16-element Si photodiode arrays

Driver circuit for CCD linear image sensor

InAsSb photovoltaic detector

PbSe photoconductive detectors

Si photodiode. Applicable to lead-free solder reflow and wide temperature range. S9674. Absolute maximum ratings

1-D PSD with small plastic package

Photo IC diode. Plastic package shaped the same as metal package. S SB. Absolute maximum ratings (Ta=25 C)

InGaAs PIN photodiode arrays

New product of near infrared (to 900 nm) detection

NMOS linear image sensor

InAsSb photovoltaic detectors

16-element Si photodiode arrays

Parameter Specification Unit Photosensitive area mm Package Glass epoxy - Seal material Epoxy resin -

Photo IC diode. Wide operating temperature: -40 to +105 C. S MT. Absolute maximum ratings (Ta=25 C)

Applications. Photosensitive area size. Storage temperature Tstg (mm) (mm 2 ) (V) ( C) ( C) S

Photodiode modules. C10439 series. Integrates photodiode for precision photometry with low-noise amp.

Non-discrete position sensors utilizing photodiode surface resistance

MCT photoconductive detectors

Mini-spectrometer. SMD series C14384MA-01. High sensitivity in the near infrared region (to 1050 nm), ultra-compact grating type spectrometer

High-speed photodiodes (S5973 series: 1 GHz)

Variable gain and stable detection even at high gains

MPPC (Multi-Pixel Photon Counter)

MCT photoconductive detectors

Driver circuit for CCD image sensor

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

Applications. l Image input devices l Optical sensing devices

Mini-spectrometer. TF series. Compact and thin, built-in high-sensitivity CMOS image sensor for Raman spectroscopy C14214MA. Applications.

APD module. Variable gain, stable detection even at high gain. C Applications. Features. Sensitivity vs.

Photo IC for optical switch

mini-spectrometer TG series Long-wavelength type (to 2.55 μm) nearinfrared C11118GA Optical characteristics (Ta=25 C)

TM series TM-UV/VIS-MOS

S P. Ultra-miniature, high performance Electromagnetically driven laser scanning MEMS mirror. Features.

Mini-spectrometer. TM series. Trigger function and a high sensitivity CMOS image sensor included. C11697MB. Optical characteristics

Reduced color temperature errors

16-element Si photodiode arrays

Driver circuits for photodiode array with amplifier

WAFER PROBER MODEL. IR-OBIRCH analysis system Infra Red - Optical Beam Induced Resistance CHange AMOS -200

Near infrared image sensor (0.9 to 1.7 µm) with high-speed data rate

Mini-spectrometer. TG series. Enhanced near infrared sensitivity type. C9405CB. High sensitivity in near infrared region

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Photo IC diode. COB (chip on board) type, small package. S CT. Absolute maximum ratings

CMOS linear image sensors

Mini-spectrometers. TM series. High sensitivity type (integrated with backthinned type CCD image sensor) C10082CA/C10083CA series

MPPC modules. Photon counting module with built-in MPPC. C series C10751 series. Selection guide

Between elements measure. Photosensitive area (per 1 element)

Cardiomyocyte in-vitro Toxicity Assay

Mini-spectrometers. TG series. High sensitivity type (integrated with backthinned type CCD image sensor) Optical characteristics

Transcription:

Quickly converts glass slides into high-definition digital data by high-speed scanning! Views the entire image of a sample and magnifies images to any size or detail just the same as by microscope observation. The NanoZoomer Series is a family of digital slide scanners that convert glass slides into high-resolution digital data by high-speed scanning. The NanoZoomer comes with a variety of functions such as image acquisition of fluorescence samples and multilayer acquisition. Scanned data can be viewed on a PC monitor by using the dedicated viewer software, and patented navigation map technique* delivers slide viewing environment just as if operating a microscope. *US Patent RE42,220E Digital slides have many advantages! Digitizing slides opens up a variety of new possibilities. Copying and Sharing Databases Digitized slides can be copied and shared. This feature of digital slides can be used in a variety of applications. For example, a large group of people can observe and discuss a single sample. Large numbers of digital slides can be stored into a database and incorporated into a laboratory information system. You can share data and construct slide libraries with distant facilities and research institutes. Slide Storage Digital data does not deteriorate, and it is more secure from damages and losses than glass slides. You can view digital data in its original quality anytime and anywhere. Networks Using the Internet or a local area network, you can observe and evaluate slides from a distant location. 2 * The NanoZoomer series as medical devices may be subject to government regulations where they are used. Hamamatsu makes no representation with regard to the conformity of these products to these regulations. Please consult your local Hamamatsu representative for more information.

High-end model NanoZoomer -XR Comes with rapid automatic processing of up to 320 slides, dynamic focus, and image quality judgment functions The NanoZoomer-XR is the next generation of digital slide scanners that delivers rapid yet high-quality scanning and also easy operation via automatic control. It quickly processes a huge volume of slides and the auto focus judgment function detects all types of scanning errors. Standard model NanoZoomer 2.0 -HT HT Automatic processing of up to 210 slides and a solid history of stable performance The NanoZoomer 2.0-HT is a user-friendly scanner designed to process up to 210 slides automatically. Just set the slides and press the start button, and all tasks from transferring the samples to acquiring their images are performed automatically. Since its launch on the market the NanoZoomer 2.0-HT has earned itself a high reputation from our many users. XR Compact model NanoZoomer 2.0 -RS RS Automatically process up to 6 slides of regular size or 2 slides of double size The NanoZoomer 2.0-RS is compact and affordable. It maintains the performance of the NanoZoomer 2.0-HT except for the number of slides processed automatically. It processes up to 6 slides of regular size (76 mm 26 mm) or 2 slides of double size (76 mm 52 mm) automatically. (The processing of double size slides is an optional feature.) Newly installed scan function XR This function delivers high-quality scanning along with smooth and easy operation. It is incorporated only into our top-end model - the NanoZoomer-XR. Sharp focus on entire specimen: Dynamic Pre-Focusing The NanoZoomer-XR uses its unique Dynamic Pre-Focusing Sample method (patent pending) to track and keep specimens in focus while scanning. It analyzes focus status right before capturing Glass slides an image and adjusts the objective lens to focus the image in real time. It keeps sharp focus on the entire specimen to generate high quality digital slides even from specimens which are difficult for the traditional focus mapping method. UP object lens object lens Analyze focus status Acquire focus image Focus status is analyzed right before imaging in real time. The focus status is used to control an objective lens in real time to acquire focused image. Free from time consuming manual slide quality check: Automatic focus scoring Manual slide quality check is often conducted after scanning to avoid scanning failure caused by dirt on a slide or sample folding. The NanoZoomer-XR evaluates scanned digital slides automatically and generates a focus score of each slide's quality for your review. Focus check points within a scanned slide are automatically determined, at each check point, focus is analyzed. Then a focus score is generated and displayed on a monitor screen. This score can be used for automated rescan. Optimized system condition whenever you scan: Automatic system calibration To maintain optimized condition of the scanner, routine calibrations of light intensity, white balance and shading are required. The NanoZoomer-XR automatically and periodically conducts a system calibration using a calibration slide located in a slide cassette, and keeps the system optimized. Whenever you scan, you will get the best digital slides it can deliver. Light intensity changes over time or due to environment temperature. Auto calibration 3

Digital slide scanner NanoZoomer series scan principle The scan units in the NanoZoomer Series employ "line scan" and "TDI mode" to scan sample tissues on glass slides at high speed and convert them into high-definition digital images. TDI mode line scan XR HT RS Variety of superior scan features from the expertise of Hamamatsu sensor technology. TDI combines both high speed and high sensitivity 3-chip TDI camera provides superior color reproduction The NanoZoomer series uses time delay integration (TDI) to provide high speed and high sensitivity simultaneously. Hamamatsu technology allows synchronizing TDI sensor signal with the movement of a microscopic sample object being scanned. The NanoZoomer series uses a 3-chip TDI camera to accurately reproduce sample colors. It enables observing minute variations in the colors of the sample. The 3-chip TDI camera has red, green and blue channels, and they are used to produce a single RGB image. Line scanning makes scanning faster Traditional CCD tiling Dedicated system design makes the NanoZoomer series user friendly and highly reliable. The NanoZoomer series is a specialized machine designed for routine use. It is user friendly and highly reliable. It employs a variety of sensors monitoring mechanical operations to ensure the safety of your slides. TDI Line Scanning Image composition Relatively slow scan and 2D composition of tiles Image composition The image is scanned line by line. Fast scanning and 1D composition Z-stack feature for thick samples There are samples which have 3D structures such as clumps of cells and thick tissues. They require focus adjustment during observation. To handle these kinds of slides, the NanoZoomer series is equipped with the Z-stack feature that allows you to focus on different depths in the sample. The NDP.view2 viewer software lets you adjust the focus on a Z-stack slide much like you would adjust the focus of a microscope. You can also point to an area of interest and let NDP.view2 apply autofocus for maximum clarity. X-axis Z-axis Y-axis +2.5 μm Unique TDI sensors realizes both high sensitivity and high speed simultaneously TDI sensor: Four steps (the actual NanoZoomer 2.0 sensors have 64 steps) The scanned object moves constantly, and the signal is reinforced at each stage by integrating the signal. This leads to fast and sensitive scanning. TDI sensor (Four steps) Signal level Depth direction +2.50 μm +2.00 μm +1.50 μm +1.00 μm +0.50 μm ±0.00 μm 0.50 μm 1.00 μm 1.50 μm 2.00 μm 2.50 μm +1.5 μm 1st stage 2nd stage 3rd stage 4th stage -2.5 μm -1.5 μm ±0.0 μm 4

Examples Toxicity test using H&E staining NanoZoomer is available for a wide range of applications including toxicity evaluation. Liver in mouse with a dose of acetaminophen in 4 hours (Whole Image) Liver in mouse with a dose of acetaminophen in 4 hours (Magnified Image) Provision of Glass Slide Courtesy of Dr.June Kanno Division of Toxicology, Biological Safety Research Center, National Institute of Health Sciences, Japan Application for ips cells research Protein localization analysis using immunostaining NanoZoomer is great for testing ips cell differentiation ability by observation of teratoma tissue samples ranging from overall views to high-magnification images. NanoZoomer is ideal for observing localization of various types of proteins by using immunostaining techniques and so opens a host of diverse new applications. Teratoma formation by using mouse ips cells (HE-stain). Courtesy of Center for ips Research and Application, Kyoto University Specimen of needle biopsy stained by IHC(HER2) Courtesy of Dr.Kurozumi M, the Department of Pathology, Saitama Cancer Center, Japan Conferences using digital slides With digital slides, you can share the same sample among many people without worrying about sample deterioration. Observing H&E stained samples This is the basic staining method for tissue samples and is widely used for pathological examinations and tissue anatomy. PAS stained kidney biopsy sample Courtesy of Department of Pathology, The University of Tokyo Hospital, Hiroshi Uozaki, M.D., Ph.D. Pancreatic AVM with anisakiasis, resulting in pancreatic bleeding Courtesy of KobeCity Medical Center General Hospital, Department of Pathology, Yukihiro Imai, MD Ph.D. 5

Option Fluorescence imaging modules L12225 / L11600 Digitization of fluorescence samples enables long-term observation with no worries about fading, discoloration, or photobleaching. The Fluorescence Imaging Modules combined with the NanoZoomer Series are able to scan the entire image of fluorescence-stained samples at high speed and high resolution. The scanned images are saved as digital data which allows long-term observation without photobleaching which has been a difficult problem on conventional fluorescence microscopes. These modules also permit flexible observation of the overall sample image as well as the magnified or reduced images. The L12225-02 and L11600-21/-22 come supplied with a filter wheel that automatically select and switches 6 filters for excitation and fluorescence wavelengths to sequentially acquire multiple fluorescence images. The L12225-01 and L11600-11/-12 support fluorescence scanning in single, double and triple bands by simply replacing the filter cube. All models of the Fluorescence Imaging Modules use the L11600-05 light source optimized for fluorescence microscopes that features high power, high stability, and long service life. NanoZoomer-XR + L12225-01/-02 Features of fluorescence imaging modules XR HT RS NanoZoomer 2.0-HT + L11600-11/-21 Adding a Fluorescence Imaging Module captures a diverse range of fluorescence images Scans samples stained with multiple fluorescence probes The Fluorescence Imaging Modules scan and generate digital data for samples stained with multiple fluorescence probes such as Q- dots, fluorochromes, fluorescence proteins, and others. The filter wheel unit automatically selects and switches 6 filters for excitation and fluorescence wavelengths to allow sequential image acquisition at single or multiple wavelengths. NanoZoomer 2.0-RS + L11600-11/-12/-21/-22 Uses dark field illumination for sample identification Superimposes images of entire tissues The Fluorescence Imaging Modules can superimpose a bright field image and a fluorescence image or superimpose two or more fluorescence images at tissue levels. This allows observing target protein localization and expression levels across the entire image. Uses high-power and long-life light source that needs no optical axis alignment The Fluorescence Imaging Modules use the L11600-05 light source optimized for fluorescence microscopes. It offers an extremely long service life of 2000 hours as well as high power and high stability. No optical axis alignment is required even when the lamp is replaced. Fluorescence sample locations on a slide are usually difficult to find using transmitted illumination, so the Fluorescence Imaging Modules use dark field illumination * to pinpoint sample locations. This makes it easy to extract samples of interest. *Patent registered Features highly efficient optics ideal for TDI sensors To improve excitation light level density, the Fluorescence Imaging Modules efficiently condense a light flux onto the elongated area on a TDI line sensor that activates in transfer integration mode. This allows capturing even very weak fluorescence at high speed and also reduces the effect of photobleaching on samples since no excitation light is irradiated onto unwanted areas. Fluorescence module specifications Products number L12225-01 L12225-02 L11600-11 L11600-12 L11600-21 L11600-22 Applicable model XR XR HT/RS RS HT/RS RS Light source L11600-05*1 200W Ultrahigh-pressure mercury lamp Number of filter cubes installed*2 3 3 1 2 1 2 Filter wheel - 6Ex/6Em - - 6Ex/6Em 6Ex/6Em *1 See the table below for L11600-05 specifications. *2 Filter cubes and filters are sold separately. Please consult us. 6 FL-illumination lamp unit L11600-05 specification Dimensional outline / Weight Power consumption 180 mm(w) 299 mm(d) 227 mm(h) Approx. 6.8 kg 300 VA

Examples Rapid and High-Fidelity Imaging of Fluorescence-Labeled Q-dots Human pancreas Nucleus: Hoechst 33342 Chromogranin (endocrine gland, islets of Langerhans): Qdot655 Cytokeratin (exocrine gland): Qdot565 Courtesy of the Department of Pathology, Keio University School of Medicine Horizontal Section of the Nile Rat Brain Showing the Crossing of Retinal Axons in the Optic Chiasm Left eye was injected with Cholera Toxin B conjugated to Alexa 488; Right eye with Cholera Toxin B conjugated to Alexa 596. Images show the axon bundles as they cross to the opposite sides of the brain. Courtesy of the Harvey Karten, University of California-San Diego, USA; Yves Sauve, University of Alberta, Canada; Frederic Gaillard, Universite de Poitiers, Poitiers, France Observing multi-wavelength fluorescence image of TMA TMA images were acquired in the course of joint research with the National Cancer Center Research Institute, Department of Chemotherapy and Department of Pathology. 7

ERROR BUSY POWER Specifications Product name Product number Scanning method 20 mode (15 mm 15 mm) Scanning speeds 40 mode (15 mm 15 mm) Objective lens Scanning range Slide loader 20 mode Scanning resolution 40 mode Focusing method Z-stack feature Fluorescence imaging module Barcode reader Image compression Slide format Power supply voltage Power consumption NanoZoomer-XR C12000 Approx. 35 s Approx. 45 s 26 mm 76 mm Automatic, max. 320 slides Dynamic Pre-Focus Pre-Foucus map NanoZoomer 2.0-HT NanoZoomer 2.0-RS C9600 C10730 TDI (Time Delay Integration) Approx. 60 s Approx. 60 s Approx.150 s Approx. 150 s 20 (NA 0.75) User can select 20 or 40 mode at start of scanning. 26 mm 76 mm 26 mm 76 mm 52 mm 76 mm (Option) Automatic, max. 210 slides Standard size: 6 slides, Double size: 2 slides 0.46 μm 0.23 μm Pre-Foucus map Pre-Foucus map Acquires Z-stack images over entire scan area Option 1D barcode (standard feature), 2D barcode (option) JPEG compression JPEG compressed image + slide information AC 100 V to AC 240 V 300 VA 400 VA Dimensional outlines NanoZoomer-XR C12000 (Dedicated rack supplied as standard equipment) Weight Main unit: Approx.142 kg, Dedicated rack: Approx. 67 kg NanoZoomer 2.0-HT C9600 Weight Approx. 94 kg (Unit: mm) 636.5±5 742.5±5 738±3 623±5 860±10 1000±3 731±3 NanoZoomer 2.0-RS C10730 Weight Approx. 72 kg 637±5 1000±5 660±5 540±5 641.5±5 * The NanoZoomer series as medical devices may be subject to government regulations where they are used. Hamamatsu makes no representation with regard to the conformity of these products to these regulations. Please consult your local sales representative for more information. NanoZoomer is a registered trademark of Hamamatsu Photonics K.K.. The university, institute, or company name of the researchers, whose measurement data is published in this brochure, is subject to change. Product and software package names noted in this documentation are trademarks or registered trademarks of their respective manufacturers. Subject to local technical requirements and regulations. Availability of products included in this promotional material may vary. Please consult with your local sales representative. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications and external appearance are subject to change without notice. 2014 Hamamatsu Photonics K.K. HAMAMATSU PHOTONICS K.K. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Systems Division 812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-435-1574, E-mail: export@sys.hpk.co.jp U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: info@hamamatsu.de France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: info@hamamatsu.it China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: hpc@hamamatsu.com.cn Cat. No. SBIS0043E04 MAR/2014 HPK Created in Japan