DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

Similar documents
Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

PSC300 Operation Manual

MICROMASTER Encoder Module

Digital Ratio Controller

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Understanding VFD. Variable Frequency Drive. nfi. nfi

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

Revision 1.2d

Recording to Tape (Analogue or Digital)...10

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

1Ver.0.2OldStyle. t r i. v t o. m e. a c

Rebis Audio Ltd. RA226 Digital Sampler User Guide

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Automatic Control Panel, Type EP103 For electrically operated gates, barriers & doors

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

51109 Köln St. Asaph, Denbigshire LL17OLJ

Operating Instructions for Throttle Valves Using VRC Valve Positioner

SQM40/41 Actuators for air and gas dampers

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

SAUTER flexotron RDT405 Manual

Topic: Instructional David G. Thomas December 23, 2015

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

E R A I GATE OPENERS DEPARTMENT

ARC HEIGHT CONTROL (ARC VOLTAGE CONTROL) MODEL : HAC-01-A-1M

Low-cost labelling system

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

DLP200M 2 Relay Module for Heating and Cooling Plants

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

DLP600M 6+1 Relay Module for Heating and Cooling Plants

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Selection guide siemens.com/sirius-modular-system

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

DTV742 Installation Quick Start Guide

Digital Economy Seven Programmer

DIGITAL SYSTEM FUNDAMENTALS (ECE421) DIGITAL ELECTRONICS FUNDAMENTAL (ECE422) COUNTERS

PQ-Box 100 Quick Start Instructions

Single Axis Position Controller

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Session 1 Introduction to Data Acquisition and Real-Time Control

MODEL PA II-R (1995-MSRP $549.00)

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Transient Stability Events & Actions

Automatic Transfer Switch Control PLC Operator s Manual

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

3B SCIENTIFIC PHYSICS

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

TRF STEP-DOWN TRANSFORMER USER MANUAL

Noise Detector ND-1 Operating Manual

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

DTV744 Installation Quick Start Guide

3. Electronics and MMU2 unit assembly

Aspect 2 Circuit Digital Scene Control

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

LUNA 129 star-time

Operation and Maintenance Guide Electric Needle Scalers

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Motion Control G7 Drive Software Technical Manual

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Schneider Industries SAS MTN5812../MTN MTN Time switch

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

REGO Start&Go USER MANUAL

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

CAMTO LTD. Arc detecting system DC/AC

Pre-processing of revolution speed data in ArtemiS SUITE 1

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Reference Manual. Notes 9/16 Series H

STX Stairs lighting controller.

Installation Operation Maintenance

Syrah. Flux All 1rights reserved

Fluid Cooling P-BAR b Industrial BOL Series

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

K9123, K9134, K9135 Remote Programming Instructions and Specifications

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Bulletin 150, 154 Softstarters Quick Selection Table

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

INSTRUCTION MANUAL COMMANDER BDH MIG

Vintage Audio MSL-MK2. Quad VCA Buss Compressor

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

multi-function meters

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Transcription:

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER For the DAAB EP104 automatic control system with software version 4.07 Revision: 12 FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN, +46 435 77 95 00, support@faac.se www.faac.se

DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL Installation 1. 2. Disconnect the power to the EP104 Screw the DB409 card into place on the spacers on the EP104 using two M3x5 screws. Connection The frequency converter being connected to the DB409 must be a DELTA VFD-EL. This frequency converter is based on negative logic. Refer to the diagram on the next page for full details regarding signals and connecting electric motors. Information follows below on the action that needs to be taken before carrying out connection as described on the following pages. Take care to ensure that all cables marked as illustrated below are removed. If this is not done correctly, the frequency converter and the automatic control unit may be permanently damaged. Also note the direction in which the cable is routed through the coil. After modification as below, the incoming phase and neutral must be connected to T1 and N as shown on the wiring diagrams on the following pages. Pass the cable from T1 in this direction to the frequency converter. Remove Remove Remove Pass the cable from T1 through this hole Remove Remove 2

Wiring diagram for one motor Important: Before connection takes place, the following cables must be removed: The cable in X12 The cable in X17 Frequency converter Automatic control unit Power 3

Circuit diagram for two motors Frequency converter Important: Before connection takes place, the following cables must be removed: The cables between X4 and X11 The cable in X7 The cable in X12 The cable in X17 Frequency converter Automatic control unit Power (must not be used) 4

Installing the Delta VFD-EL frequency converter Modification of the motor winder The following criteria must be met in order to use the DAAB motor winder with the frequency converter: If mechanical limit switches are used, the limit switch cams must be wider than normal. FAAC Nordic AB recommends using encoder-type limit switches, DB405, together with the frequency converter. FAAC Nordic AB recommends using a motor with a speed of 2,800 rpm. Programming the frequency converter To program the frequency converter, press ENTER once to select programming mode. Select program group 00-xx to 11-xx using the arrow keys. Press ENTER to select program group. The program arrows now switch between the different program channels in the selected program group. Press ENTER once more at the selected program channel and select value using the arrow keys. When you have set the desired value, press ENTER again to save the new value. When all the programming has been done, you return to normal operation by pressing MODE until the display shows H for the output frequency concerned. Tip: By pressing MODE once more when stepping between the program channels, you change to stepping between the program groups instead. Channel settings in the frequency converter Channel no. Description 00.03 used to display the output frequency during operation after power is switched on. Factory setting 01.00 used to set the maximum output frequency 100.0 01.03 used to set the low frequency 7.50 01.04 used to set the low frequency voltage 60.0 01.05 used to set the start frequency 1.50 01.06 used to set the start frequency voltage 40.0 02.00 used to set where the setpoint value for speed is to be taken from 03 02.01 used to set the start method 01 02.02 used to set the type of stop 01 02.04 used to block reversing 01 03.00 used to set the multifunction output 01 03.08 used to set the internal cooling fan 01 04.04 used to set the function of input MI1 00 06.01 used to set the current limit for a speed increase 200 06.02 used to set the current limit at constant speed 170 06.06 used to set the electronic overload relay 02 09.00 selects communication address: 1 for motor 1, 2 for motor 2 1 09.01 used to set transfer speed 03 09.02 used to set error handling 0 09.07 used to set time delay between messages 0 01 Modified value 5

Channel settings in the EP104 when using an encoder, DB405 When a frequency converter is used with the EP104, load guard with personal protection cannot be used. For this reason, make the following channel settings in the automatic control unit: C230 = 0.00 - This parameter disables the personal protection for motor 1. C240 = 0.00 - This parameter disables the personal protection for motor 2. Depending on the setting in C200, the values in C232, C233, C242, C243 are adjusted so that satisfactory function and reliable mechanical protection is obtained for the gate or door. Other settings that may need to be made are: C202 = 4 - This parameter specifies that a frequency converter is being used. C252 = Highest value reading in channel C251 in opening movement. C253 = Highest value reading in channel C251 in closing movement. C262 = Highest value reading in channel C261 in opening movement. C263 = Highest value reading in channel C261 in closing movement. A new category of channels has been added in the EP104 with software version 4.07, F-channels. In these channels, settings are made for how the frequency converter is to work together with the EP104. To enable the E104 to control the frequency converters, the communication between them must also be started. This is done through the following setting: F001 = 1 Note that when F001=0 only hold-to-run works! If there are problems with communication or when communication is disabled, via F001, the frequency converters can be operated in hold-to-run at the same speed in both opening and closing, by changing channel 02-00 on the frequency converter to a 4 for the rotatory actuator or 0 to use the arrow keys to adjust the F-value. Note that when the rotatory actuator is turned clockwise the output frequency increases, so start by turning it to the maximum extent anticlockwise and then increase to a suitable output frequency. If communication errors occur or if communication is disabled, the motors can only be operated using hold-to-run. In hold-to-run in this mode, no ramping down takes place before open or closed position is reached. For this reason, adjust the speed and pay attention when the open or closed position is close. For the speed settings in F012, F013, F022 and F023 to work, the ratio of the motor winder must be specified in the following channels: F030 = motor winder connected to motor 1. F040 = motor winder connected to motor 2. Until ratio has been selected in these channels, maximum speed will be limited to 25Hz. If the ratio is not stated in the documentation belonging to the motor winder, a measurement can be done by displaying channel F031 or F041 and then letting the motor winder open or close until a value appears in these channels after approx. 6 seconds. Compare this value with the values specified in the instruction manual for channel F030 or F040 and specify the corresponding figure in both these channels. It is specified in channels F002, F003 and F004 how quickly the gate or door is to reach its opening or closing speed. F002 = Acceleration from fully closed position. F003 = Acceleration in all other starts. To obtain an even and jerk-free start in the fully open position, the time in F003 must be adjusted for this particular start. F004 = Acceleration when P500 is programmed to 2, Battery backup, and activated. It is specified in channels F005 and F006 how quickly the gate or door is to stop. F005 = Retardation time for limit switches and change of direction. F006 = Retardation time for photocell and vehicle loops. The times in these four channels refer to a speed which is 100Hz, i.e. the times apply when the speed is 100Hz. If the speed is lower, for example 50Hz, the time will be halved, but the force in deceleration and speed increase will be the same regardless of speed. If the times increase, the forces on the gate or door decrease in changes of speed. The factory settings are adapted to a hinged gate with a 6 metre opening. Check that the gate accelerates without subsequent swings from both the closed and open positions. Increased times reduce the risk of swings. Check also that the gate slows down gently and without jerking in the open and closed positions. With the photocell or vehicle loop activated, deceleration must take place so that no collision between the gate and the vehicle can occur. Check and adjust the time in F006. In the case of a sliding gate, the value must be specified in F002 and F003. Adapt the acceleration to the size and weight of the gate. A reasonable starting value is 5.0 seconds. The retardation in F005 and F006 is adjusted in the same way as above. The readout channels in L114, L115, L124 and L125 cannot be adjusted when the C202 has been chosen for 4 frequency converters. These channels show the calculated angle, before the limit, where the motors will go down to low speed in 6

accordance with F008 and F009. This calculated angle depends on speed, slow speed, retardation and chosen ratio. The angles in these channels are calculated continuously on the basis of these parameters. If stopping at the specified angle for open or closed position takes place too abruptly, there is a possibility of adding a certain angle to the values in these channels. This extra deceleration angle is specified in channels F014, F015, F024 or F025. Channel settings in the EP104 when using mechanical limit switches When mechanical limit switches are used, the ratio cannot be measured and must be checked in the attached documentation. Compare the specified value with the values specified in the instruction manual for channel F030 or F040 and specify the corresponding figure in both these channels. In the case of mechanical limit switches, no ramp-down angles are calculated and suitable ramp-down times must instead be tested in commissioning. Channels C422, C423, C432 and C433 specify how many seconds after the limit position has been activated the motor should run at low speed according to channels F008 and F009. Note, however, that if the time in F005 is long in relation to the times specified, the gate may perhaps not reach the speed specified in F008 and F009. For that reason, check the current output frequency by pressing the MODE button until the display begins with H. C422 = 1,50 - This parameter specifies a run-on time in opening movement for motor 1 C423 = 1,50 - This parameter specifies a run-on time in closing movement for motor 1 C432 = 1,50 - This parameter specifies a run-on time in opening movement for motor 2 C433 = 1,50 - This parameter specifies a run-on time in closing movement for motor 2 Note that the switches above the terminal block must be in the upward position! (NPN/AVI) 7

Channel list, Frequency converter, F-channels DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL No. Name Range Factory Setting Ref. page F001 Communication with frequency converter 0-1 0 0 Communication disabled 1 Communication activated F002 F003 F004 F005 F006 Acceleration time from closed position motor 1 and 2 (from 0-100Hz) Acceleration time in all movements except at closed position motor 1 and 2 (from 0-100Hz) Acceleration time when P500 is set to 2 and the input is activated, battery backup Retardation time with limit switch and change of direction for motor 1 and 2 (from 100-0Hz) Retardation time with photocell and vehicle loops for motor 1 and 2 (from 100-0Hz) 0.5-9.9 seconds 1.0 sec 0.5-9.9 seconds 3.0 sec 5.0-12.0 seconds 7.0 sec 0.5-9.9 seconds 3.0 sec 0.5-9.9 seconds 1.0 sec F008 Low-speed frequency for opening movement 5-20 Hz 10 Hz F009 Low-speed frequency for closing movement 5-20Hz 10 Hz F012 Opening frequency / Opening speed for motor 1 21-99Hz 60Hz F013 Closing frequency / Closing speed for motor 1 21-99Hz 30Hz F014* Increase in limit in L114 as speed will decrease during the opening movement, motor 1. (Only when using a frequency converter) F015* Increase in limit in L115 as speed will decrease during the closing movement, motor 1. (Only when using a frequency converter) 0-60 0 0-60 0 F022 Opening frequency / Opening speed for motor 2 21-99Hz 60Hz F023 Closing frequency / Closing speed for motor 2 21-99Hz 30Hz F024* Increase in limit in L124 as speed will decrease during the opening movement, motor 2. (Only when using a frequency converter) F025* Increase in limit in L125 as speed will decrease during the closing movement, motor 2. (Only when using a frequency converter) 0-60 0 0-60 0 8

F030 Choice of ratio for motor 1 0-7 0 <?> 0 Not selected, in this position the motor only rotates at 25Hz 1 MK with pulleys 40/71 (ratio 1318:1) 2 MK with pulleys 50/71 (ratio 1098:1) 3 MK with pulleys 71/71 (ratio 791:1) 4 MK with pulleys 100/71 (ratio 565:1) 5 MK with pulleys 125/71 (ratio 456:1) 6 MK with pulleys 140/71 (ratio 409:1) 7 MT (ratio 791:1) F031 Measured ratio motor 1. Only when F030=0. 0-2000 0 F040 Choice of ratio for motor 2 0-7 0 <?> 0 Not selected, in this position the motor only rotates at 25Hz 1 MK with pulleys 40/71 (ratio 1318:1) 2 MK with pulleys 50/71 (ratio 1098:1) 3 MK with pulleys 71/71 (ratio 791:1) 4 MK with pulleys 100/71 (ratio 565:1) 5 MK with pulleys 125/71 (ratio 456:1) 6 MK with pulleys 140/71 (ratio 409:1) 7 MT (ratio 791:1) F041 Measured ratio motor 2. Only when F040=0. 0-2000 0 * = Appears only when L001 and/or L002 are set to 1 encoder. 9