Practicum 3, Fall 2010

Similar documents
Practicum 3, Fall 2012

Procedure for Acquiring 2D Inverse Detection Spectra HMQC, HMBC and HSQC

Basic 13 C Acquisition and Processing 4

Processing data with Mestrelab Mnova

Standard Operating Procedure of nanoir2-s

PulseCounter Neutron & Gamma Spectrometry Software Manual

IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface)

GS Bloch Equations Simulator 1. GS Introduction to Medical Physics IV Exercise 1: Discrete Subjects

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

NMR. picospin. Maintenance Guide

PINMRF. Checkout Quiz - Varian Inova-300 Version

cyclenoe 1D NOE Difference Experiment

MestReNova A quick Guide. Adjust signal intensity Use scroll wheel. Zoomen Z

Introduction to 1D & 2D NMR using VnmrJ

1 H HOMODECOUPLING EXPERIMENT

DektakXT Profilometer. Standard Operating Procedure

Vnmrj Training Guide. Vnmrj overview

MestReNova Manual for Chem 201/202. October, 2015.

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

Linrad On-Screen Controls K1JT

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

E X P E R I M E N T 1

PS User Guide Series Seismic-Data Display

Topic: Instructional David G. Thomas December 23, 2015

Pre-processing of revolution speed data in ArtemiS SUITE 1

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

System Requirements SA0314 Spectrum analyzer:

How to Optimize Ad-Detective

NanoTrack Cell and Particle Tracking Primer

Figure 1. MFP-3D software tray

User Manual VM700T Video Measurement Set Option 30 Component Measurements

The Measurement Tools and What They Do

Fall 2014 Chem 636 Lab #4

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

SEM- EDS Instruction Manual

Processes for the Intersection

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX

Multiparametric MRI Prostate Imaging Protocol November 2015 Full Acquisition Protocol with Parameters GE 3T Magnet with Software Version DV25

Detect Color and Shape for various inspection

Tips and Tricks Part-II: Bits and pieces

imso-104 Manual Revised August 5, 2011

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

imso-104 Manual Revised July 19, 2012

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

CMRRpack2. a collection of pulse sequences from the. University of Minnesota, Center for Magnetic Resonance Research (CMRR) Version: 2.

RAD 465 (MRI) Lecture one (Pulse Sequences) Ruba Khushaim MSc

NMR TRAINING MANUAL LINUX-BASED SPECTROMETERS. And VnmrJ 2.x TEXAS A&M UNIVERSITY DEPARTMENT OF CHEMISTRY

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

ZONE PLATE SIGNALS 525 Lines Standard M/NTSC

Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

SigPlay User s Guide

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Computer Graphics Hardware

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Torsional vibration analysis in ArtemiS SUITE 1

ISOMET. Compensation look-up-table (LUT) and Scan Uniformity

Agilent DSO5014A Oscilloscope Tutorial

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

Digital Storage Oscilloscopes 2550 Series

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Q Light Controller+ Positions and EFX explained

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Standard AFM Modes User s Manual

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

MODIFYING A SMALL 12V OPEN FRAME INDUSTRIAL VIDEO MONITOR TO BECOME A 525/625 & 405 LINE MULTI - STANDARD MAINS POWERED UNIT. H. Holden. (Dec.

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

1 Ver.mob Brief guide

PicoScope for Windows user guide Chapter 1: Overview Chapter 2: Views Chapter 3: How To.. Chapter 4: Menus Chapter 5: Dialogs

A HIGHLY INTERACTIVE SYSTEM FOR PROCESSING LARGE VOLUMES OF ULTRASONIC TESTING DATA. H. L. Grothues, R. H. Peterson, D. R. Hamlin, K. s.

Fig. 1. The Front Panel (Graphical User Interface)

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

Calibrating the timecode signal input

Liquid Chromatography- Mass Spectrometer Manual

technical note flicker measurement display & lighting measurement

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals

HX0074 DEMO Kit for METRIX Oscilloscopes

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions

Jürgen Wüst 2008 年 10 月

Chapter 7. Scanner Controls

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

OSCILLOSCOPE AND DIGITAL MULTIMETER

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

GLog Users Manual.

013-RD

Quick reference guide

Diogen 24/24 two-regime seismograph

StaMPS Persistent Scatterer Practical

Analysis of AP/axon classes and PSP on the basis of AP amplitude

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

PicoScope. User guide. Copyright 2005 Pico Technology Limited. All rights reserved. PSW044 v1.5

9070 Smart Vibration Meter Instruction Manual

Transcription:

A. F. Miller 2010 T1 Measurement 1 Practicum 3, Fall 2010 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z magnetization Knowledge of T1 enables you to make an informed choice of the duration of delay between scans. If too short a relaxation delay is chose, then the peaks of slowly recovering protons will be smaller than they should be, and it will not be possible to compare peak areas to learn about proton numbers. Also, we use the T1 as our first estimate for choosing mix times in NOESY spectra, and 3xT1 as our relaxation delay in NOESY spectra. Hence the need to know T1. Start with a beautiful 1d spectrum, and a calibrated pw90. (It turns out that the default value in the probe file is a good compromise for people in a rush or not bothered about perfection.) Under the Experiments choose 'convert current parameters to do... > Relax. Measurements > T1' This will retain your current sw, tof and pw90, but it will add a few features to the experiment to support measurement of the magnetization's recovery after inversion. To see the pulse sequence click Sequence in Figure 1. The first pulse is a 180 pulse (p1=2*pw90) that will invert magnetization. This places it in a high energy state with respect to the field, so it will 'decay' back to the resting state. Time is allowed for this process, in the form of a delay called d2 [3]. So far all magnetization is still along Z, but its amplitude is recovering with time. To determine what the amplitude is after a given time d2, we use a 90 pulse (pw) [4] to 'read' our magnetization by rotating it into the XY plane where our receiver coils detect it [5]. We cannot monitor recovery continuously, instead we repeat the experiment 6 or more times, waiting a different amount of time d2 in each repeat before executing the read pulse. Thus we end up with a series of 1d spectra, each representing a different duration of recovery after the inversion pulse. In Acquire>Defaults, a set of three boxes invites you to enter first guesses of the T1s you sample may have, and Varian uses these to set the delays in the experiment to perform a measurement (you will have to use the scroll bar on the RHS of the panel to reveal these) [6]. Set T1 Mode to inversion recovery [7] (don't worry if the bar stays blank), then set T1 min to the shortest T1 you expect to be present among your resonances (say 0.2 sec.: enter 0.2) [8], the longest T1 you anticipate (err on the long side here, say 3 (seconds)) and the time you are willing to devote to the experiment (eg. 0.1 (hours)). The min. and especially the max times will be used to choose an array of d2 values ranging from very short to something on the order of your maximum estimate. You can see these by clicking on 'Arrays'. [9]. The experiment takes a long time in part

A. F. Miller 2010 T1 Measurement 2 due to the long relaxation time allowed between scans [10]. This is chosen to be 5 times your estimated longest T1. The duration of the experiment also increases in proportion to the number of scans collected for each value of the delay d2. Therefore, we will cut back on the number of scans if possible (I will change 4 to 1 [11]). You may also want to go into the 'Array' panel and decrease the number of values of d2 used. Because we are expecting an exponential recovery, we anticipate that an exponential array will be a better choice than a linear array (Figure 2). Thus in this case successive values of d2 are 2x the previous value, rather than being some value plus the previous value. The increment is the ln(2). If you want to triple each value to get the next one, use an increment of ln(3)=1.1. If I am rushing I choose an array size of 6 (the minimum allowed) and an increment 1.1. The resulting array covers a factor of approximately 700. Thus for a longest estimate of 3 seconds I want a shortest value of 0.004. I go back and make adjustments to the first value and increment as needed to get the last value I want. Make sure that Gain is a number, not autogain (Acquire>Acquisition) As always, close the Array box, check Sequence, Show Time and then Acquire. The result should be a series of spectra in which we see that spins are initially inverted and then gradually recover as the delay d2 is made longer (Figure 3). In the LHS panel, with the 'Arrayed Spectra' tab active, change values in 'Chart Dimensions'. For Vert. Pos. use 20 (from 90) Vert Height 300 (from 900). Under Offset Vertical change this interactively (step size of 10) [3] with +10, it gives 17.7 (a good display) and in "Show" check the 'values' box [4]. You see that different peaks recover in different times. The null represents approx T1 *0.7. Divide null time by 0.7 to estimate T1 1 sec/.7 = 1.4 sec for peak at 6 ppm. 0.5 s /.7 = 0.7 S for aliphatics. In Process>T1 Analysis (Figure 4 ), click on Display Last Spectrum. It should be upright as shown. If it is not, you will have to phase it manually (after activating the additional options on the right hand side of the graphical display window [3]). Figure 4 shows a case where the software picked a ridiculous number of lines. Activate the action buttons on the RHS of the graphics display window [3] and activate threshold (Figure 5 ). Move the threshold up to be more selective. You can also use the cursors to restrict your analysis to one region of the spectrum by placing cursors around it and clicking the '+' magnifying glass [3]. Then click on 'Do T1 Analysis' [4]. All the lines the instrument picked will be in the table in the RHS box [5]. If you scroll all the way to the right edge of the box with the numbers in it [6], a second vertical scroll bar will appear inside the one visible in the figure. You may only be able to see the small down arrowhead at the bottom. Click on that to scroll up and down. First, all the picked peaks are listed and each is assigned an 'index' number, which will be used below to provide the T1 for the corresponding peak. Next there is a summary of the analysis in which each peak's T1 is provided

A. F. Miller 2010 T1 Measurement 3 along with the associated error. Finally a detailed analysis follows for each picked peak. Using the chemical shifts provided with the spectrum (Figure 6 ) in conjunction with the numerical output telling you which index number corresponds to each chemical shift value you can select a few lines and for them plot the peak amplitude vs. duration of recovery d2. Next to 'Display Selected Fits' enter the line numbers for the lines you would like information on, for example "1, 10, 36" [3]. Then <return>. A time course of magnetization recovery is produced (Figure 7). Don't believe T1 values derived from curves that don't fit the data well. Don't believe any values whose errors are more than 10% the value (read the numerical output in the summary of analysis section). Don't believe a T1 that are more than one third of the recovery time you used between scans (=d1+at). If the T1s you get are longer than (d1+at)/3, repeat the experiment with a longer d1, roughly 5 times the longest T1 you got. To get a copy of the graphical output, use the LHpanel's 1D tab (Figure 8 ), click 'Print Screen...". In window that opens (Figure 9) select PSland, ( ) file, give name with path (eg. che555/data/yourname/yourfile (omit the.ps), POSTSCRIPT, Mono/Color... Save, then Close As usual, you can save your data set as a.fid file using the diskette icon in upper left. (Figure 10) Illustration of why the relaxation delay must be longer than T 1 If you do not allow sufficient time between scans for resonances to recover, they will be smaller in subsequent scans. If the total recycle time (d1+at) is shorter than the T1s of some resonances but longer than the T1s of others, then the former resonances will be shrunken more than the others, in your spectra. Thus, peak areas will no longer be proportional to the numbers of protons associated with each peak. Figure 11 compares the results of using four different d1 values all in combination with an at of 0.5. Thus, the total recycle times were 11.5, 3.8, 1.5 and 0.8 s (for d1 values of 11, 3.3, 1.0 and 0.3 s). The results show that the 0.8 s recycle time causes aromatic resonances, in particular, to be proportionaltely smaller (Figure 12). Note that the TMS line is also much smaller compared to the other lines when recycling is fast. The above partial saturation of slow relaxing resonances can be prevented either by choosing a longer (d1 + at) or by using a smaller tip angle pulse. If you use a 45 pulse then you do not have to wait as long between scans, because magnetization does not need to recover as much.

A. F. Miller 2010 T1 Measurement 4 Using a smaller tip angle in combination with a shorter recycle time allows you to get the best data per hour of spectrometer time. This is invaluable for weak spectra such as 13 C 1ds, or samples that are not stable. Once you know T1 the software can calculate the optimal pulse width and tip angle given a choice of d1. In the command line type 'ernst(3.4, 13.6)' for the example of a case where the T1 is 3.4 s. and the pw90 is 13.6 us. Thus the general form of the command is 'ernst(t1_est, pw90)'. This causes the software will update the pulse width and tip angle of the experiment for maximal sensitivity per hour of spectrometer time, given the d1 value in your parameter set.

[3] [4] [5] T1, Figure 1 [6] [7] [8] [11] [10] [9] T1, Figure 2

T1, Figure 3 [4] [3] T1, Figure 4 [3]

T1, Figure 5 [3] [5] [6] [4] [7] T1, Figure 6 [3]

T1, Figure 7 T1, Figure 8

T1, Figure 9 T1, Figure 10

T1, Figure 11 T1, Figure 12