Reference: For use with LED light engines Geometry (l x w x h): Line voltage, nominal Perm. voltage fluctuations Line current, nominal Inrush current, typical Line frequency Protection Class Output operating voltage range Max. Output Voltage peak data PrevaLED Linear Slim, PrevaLED Area, PrevaLED Bar 280 x 30 x 21 mm 220 240 V AC 198 264 V AC 390 ma @ 230 V / 50 Hz / full load 40 A peak (up to 11 devices on B16 circuit breaker) 50/60 Hz I 50-120 V DC 420 V Nominal output current 700 ma +/- 5% Nominal output power 80 W Power factor 0,95 Full load efficiency > 92% Maximum power losses Control 5 W @ 80W Power Output DALI Dimming range 3% - 100% PWM frequency 400 Hz Max. case temperature on Tc 75 C Temperature range Ta Storage temperature Nominal Lifetime at Tc max No-load proof Short circuit proof Overload protection Overheating protection Approvals -20 C to +45 C -40 C to +80 C 50.000 h Yes Yes Autom. shutoff, reversible Autom. shutoff, reversible Page 1 of 6
Safety Performance Radio interference Harmonic content Immunity: Wiring: EN 61347-1, EN 61347-2-13 EN 62384 EN 55015 EN 61000-3-2 EN 61547 Connection, primary Push-in terminals Wago 250 Cross section, primary 0.5 1.5 mm² Connection, secondary Push-in terminals Wago 250 Cross section, secondary 0.5 1.5 mm² Cable connection It is recommended to use AWG 20 (0.5-1.5 mm²) solid wire for connection If you establish the connection by means of other wire sizes (AWG 18-19) (or you use a flexible wire) you should use bootlace ferrules for the connection on the ECG secondary side. Note: insulation diameter for the connection wires max 2.0 (±0.05) mm Earth connection Earth connection is mandatory in class I luminaires and improves EMI compliance according EN 55015. CLASS I CONNECTION Page 2 of 6
Geometry Connection of LED modules ** digital DALI signal Page 3 of 6
1 driver OTp DALI 80/700 LS operates: A) Prallel circuit Product name Modularity Circuit Current Luminous flux Current Luminous N Diagram typical typical provided flux provided LEP-4000-840-LS-560 2 A 2 832 8000 lm 700 ma 6880 LEP-4000-830-LS-560 2 A 2 852 8000 lm 700 ma 6560 LEP-2000-840-LS 4 A 4 832 8000 lm 700 ma 6880 LEP-2000-830-LS 4 A 4 852 8000 lm 700 ma 6560 LEP-2000-840-LS-560 4 A 4 720 8000 lm 700 ma 7780 LEP-2000-830-LS-560 4 A 4 816 8000 lm 700 ma 6720 LEP-1000-850-LS 8 A 8 720 8000 lm 700 ma 7780 LEP-1000-840-LS 8 A 8 720 8000 lm 700 ma 7780 LEP-1000-830-LS 8 A 8 816 8000 lm 700 ma 6720 LEP-1000-840-A 8 A 8 752 8000 lm 700 ma 7440 LEP-1000-830-A 8 A 8 848 8000 lm 700 ma 6600 LEP-1000-840-B 8 A 8 768 8000 lm 700 ma 7280 LEP-1000-830-B 8 A 8 864 8000 lm 700 ma 6480 LEP-630-840-LS 12 A 12 648 7560 lm 700 ma 8160 LEP-630-830-LS 12 A 12 696 7560 lm 700 ma 7600 Installation notes The luminaire manufacturer is responsible for providing the required clearances and creepage distances and also for the protection against electrical shock, especially for the line and load wires according to EN 60598-1. Metal reflector must be earthed. Distance between the module edge and the nearest conductive path on PrevaLED Linear SLIM module is 3,1mm (around M3 holes) and 2,9mm (around M4 holes) incl. tolerances. CTI value for the module insulation layer 600 (basis insulation). Page 4 of 6
All values are in mm. Red keep-out area, green available space for mounting. Please consider the creepage and clearance distance values according to EN 60598-1. This value equals 2.52mm for max output voltage of 420V in case of OTp DALI 80/220-240/350LS and CTI 600 (basis insulation). This value is valid, if the module is used within luminaire of min. IP20 or higher protection class. To keep specified creepage distance of 2.52mm following screw and insulation washer standards are recommended: Creepage distance acc. to DIN60598-1: basis insulation PTI>=600 Uoutmax=420V:2.52mm M3 M4 Screw standard DIN920 ISO 4762 ISO 7380 DIN 920 DIN 7984 Washer standard ISO7093 ISO7093 ISO7093 ISO7089 ISO7093 ISO7093 Resulted creepage, mm 3.15 2.99 2.8 2.7 3.85 3.1 If the listed components are used, all requirements of EN 60598-1 are fulfilled. Clamps and clips can be applied taking into concideration clearance and creepage distances according to the drawing and the table. Immunity tests EN 61547 To meet immunity requirements it is recommended to implement a block trap in the input wires of the OTp DALI 80 driver in applications with PrevaLED Linear Slim light engine (LEP-xxxx-xxx-LS). Page 5 of 6
Ordering code Product group Product name EAN * S-Unit ** OPTOTRONIC 4008321 824905 25 *) EAN: Ordering number per single driver **) S-Unit: products per shipping unit Sales and Support OSRAM GmbH Hellabrunner Strasse 1 D - 81536 München Deutschland www.osram.com +49 89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. Related and Further PrevaLED Application Guide www.osram.com/prevaled-linear OPTOTRONIC Guide www.osram.com/ecg-downloads OPTOTRONIC Data Sheets http://catalog.myosram.com Page 6 of 6