NEA WIRING CENTRE NEA HT 230V /24 V

Similar documents
4 Wiring Brochure Wiring and installation of specific control

DLP200M 2 Relay Module for Heating and Cooling Plants

TRF STEP-DOWN TRANSFORMER USER MANUAL

DLP600M 6+1 Relay Module for Heating and Cooling Plants

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

PayMatic P2000. Installation Manual PayMatic P2000. Product Version: N/A. Version of this manual: Inepro B.V. All rights reserved

.Power Distribution Center. PD-1. Instruction Manual

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

INSTRUCTION & INSTALLATION GUIDE

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

MICROMASTER Encoder Module

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

LED control gear Compact fixed output

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

KRF EMC Filters Installation, Operation and Maintenance Manual

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Figure 1: Device components

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

LED Driver Compact dimming

OM2000N INSTALLATION MANUAL

LCD Thermometer / Clock S No. 1253

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Heating thermostat Series AMHs B Operating Instructions 11.06/

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

1440/2880 HP RGB+WW+CW

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

TVAC20000 User manual

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

CPS 505 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

LED Driver Linear / area fixed output

Power Injector 1520 Series

LED Driver Compact fixed output

User Manual. Model 979T and 979R Digital Audio Converters

16 Amp Electronic 24 Hour/7 Day Time Controller

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

3 Cleaning. 4 Technical data

Trusted 40 Channel 120 Vac Digital Input FTA

LED Driver Compact fixed output

Trusted 40 Channel 120 Vac Digital Input FTA

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

7 Day Digital Programmer 3 Channel Surface Mount

INSTALLATION AND OPERATION M

Panel-mounting thermostats, type series EM

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

Operating Instructions Dimmer for V Incandescent Lamps

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

XT-17M-B relay - Delay-off, 1 C/O, 16 A

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

TS2.8 Sub OWNER S MANUAL

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Photovoltaic Module Installation Manual (IEC)

multi-function meters

Thank you for purchasing a qualiton PHONO preamplifier!

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

User Guide. HDMI Fiber Optic Extender. DVI-7350a

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

Installation Guide VL-MV10. Model No.

10 PDUs 19 PDUs Zero-U PDUs

TUC: Universal thermostat

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

PRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

2-output DALI controller

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Programmable Room Thermostat With RF

02/11/2015

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

User guide. Preamble. unpacking

LED Driver Compact fixed output

LED MODULES READYLINE DL

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Model Number Structure

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Tube Rotator. User Guide. Version 1.2

SAUTER flexotron RDT405 Manual

I N S T R U C T I O N D A T A

Transcription:

NE WIRING CENTRE NE HT 230V /24 V

EN INSTLLTION INSTRUCTION Supplied in the packaging 1x 2x Introduction efore working with the NE wiring centre, this instruction is to be read completely and thoroughly. This instruction must be kept and handed over to future users. You can view and download these instructions and more at www.rehau.uk/neafamily. Safety Intended use Depends on the power supply of the wiring centre, the REHU NE wiring centre serves - for the installation of a single-room control up to 6 zones for heating applications. - for the installation of up to 6 NE room controllers 230 V or 24 V (do not mix 230 V and 24 V). - for the installation of up to 15 REHU (UNI) actuators 230 V or up to 15 REHU (UNI) actuators 24 V (do not mix 230 V and 24 V). - for the connection of an external timer. The REHU wiring centre only serves for fixed installations. Safety instructions ll safety notes in this instruction must be observed in order to avoid accidents with personal damage or property damage. Serious danger is present due to applied voltage at the wiring centre! - Only an authorised person may open the device. - lways disconnect from the mains and make safe before opening. - Disconnect external voltages and confirm isolation. - Only use the product if it is supplied as new. - Do not operate the device without device cover in place. - Caution when using this device persons should be knowledgeable, supervised or instructed concerning the safe use of the device and understands the resulting risks. This also applies when used or operated by children from the age of eight (8) years or persons with reduced physical, sensory or mental abilities or lack of experience. - Ensure that no children play with the product. - In case of emergency, disconnect the complete room temperature control system. 2 Requirements with regard to personnel The electrical installations must be performed according to the current national regulations as well as according to the regulations of your local energy supplier. It is recommended that persons carrying out work on this device is suitably qualified to do so. For example: - Heating and ventilation - pproved Electrical Installer - Electronics Engineer as in accordance to the profession designations officially announced in the UK, as well as according to comparable professions within the European Community Law. Device overview Connections and indications The following instructions show the full equipment. Depending on the wiring centre type several positions may be omitted. 1 2 3 4 5 6 7 8 230V L N L N 24V L1 L2 L1 L2 NO Nachlaufzeit Shut-down delay 14 HZ 3 HZ 4 HZ 5 HZ 6 HZ 7 HZ 8 HZ 9 HZ 10 8..9mm 2 3 10min 15min 2 3 HZ 2 24V T2 230V T4 H 0min 5min 2 3 NC T %H 9 9 HZ 1 90mm 2 3 13 12 11 1. oiler connection 2. Pump connection 3. Protective conductor connection 4. Voltage supply 5. Fuse 6. Temperature limiter or dew point sensor 7. Reduction channel, external timer 8. Heating/cooling change-over 9. Thermostat connection 10. LEDs 11. Strain relief 12. Connection of actuators 13. DIP switch 14. Contacts for casing cover with integrated system clock Technical data Operating voltage Wiring centre NE HT 24V 24 V ±20 %, 50 Hz Wiring centre NE HT 230V 230 V ±10 %, 50 Hz Power consumption 24 V 230 V 30 V 50 V Fuses 24 V 230 V T2 T4H Number of heating zones 6 Max. number of thermostats 6 ctuators 6 heating zones Nominal load of all actuators max. load 24 W Pump/boiler control Yes max. 15 (230V) max. 15 (24 V)

EN Switching power 2 200 V inductive Turn on delay 2 mins Follow-up time fixed/ adjustable 2 mins/ 5-15 mins Valve protection function* 14 days for 10 minutes Pump protection function* 14 days for 1 minute Control direction NC or NO supplied NC values selectable mbient temperature 0 to +50 C Storage temperature -20 to +70 C mbient humidity 80 % non-condensing Protection class 24 V 230 V Type of protection IP 20 Dimensions (H x L x D) 90 x 326.5 x 50 mm Weight 427.6 g ±35 g oiler and pump timing Comes with a standard delay of 2 minutes for both pump and boiler (on and off) i.e. jumper switches 2 and 3. III II * when used with NE H and NE HT room controllers (value is adjustable) Compliance This product is CE marked and thus is in compliance with the requirements from the guidelines: - 2004/108/EG with amendments Council Directive on the approximation of the laws of the Member States relating to Electromagnetic Compatibility - 2006/95/EG with amendments Council for Coordination of the Regulations of EU Member Countries regarding the electrical equipment for use within certain voltage limits - 2011/65/EU Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Increased protection requirements may exist for the overall installation, the compliance of which is the responsibility of the installer. Time 0 minutes 5 minutes 10 minutes 15 minutes Jumper 2 OFF OFF ON ON Jumper 3 OFF ON OFF ON Electrical connection For the connection of the mains voltage supply, the cable sections must be a minimum of 0.75 mm² for 24 V or 1.5 mm² for 230 V. The voltage supply of the 24 V version must come from a safety transformer according to EN 61558-2-6 or, for North merica, from a Class II Transformer according to UL. Depending on the voltage version of the wiring centre it is possible to tap L1 or L or L2 respect. N as well as the protective earth via the wiring centre. If no temperature limiter is connected, the connection T/%H must be bridged. Once a temperature limiter or a dew-point sensor is connected, the bridge must be removed. The temperature limiters are normally closed contacts. The wiring of the controller depends on the wiring centre used. For wiring purposes, please observe the instructions of the thermostat or of the respective component. Symbols - Installation 1 Jump switches - Three switches - Switch 1 alters the actuator control direction operation from normally open (NO) to Normally Closed (NC) - Switch 2 and 3 increases the operation time to 5, 10 and 15 minutes. 2 + Controller NE ctuator Pump ~ Voltage source Temperature limiter 2 System clock Heating/cooling change-over Cooling Heating 1. Remove the cover. 2. Installing the wiring centre. In case of wall mounting, fix the base to the wall with 2 screws Ø 4 mm and corresponding wall plugs according to the quality of the wall. In case of installation on a mounting rail, use a rail TS 35/7.5. 3. Terminate electrical connections. 4. Reinstall the cover. 5. Test the installation before applying Wiring diagram included at the end of the document. Maintenance Fuse change WRNING! ELECTRICL VOLTGE! DNGER TO LIFE 3

EN efore opening the controller disconnect the wiring centre from mains and ensure it is isolated and locked to stop it from being switched on again. Disconnect external voltages and secure against unintended activation. 1 2 3 24 V 230 V T2 T4H Cleaning Only use a dry and solvent-free, soft cloth for cleaning. Dismantling WRNING! Electrical voltage! Danger to life! - efore opening the controller disconnect the wiring centre from mains and ensure it is isolated and locked to stop it from being switched on again. - Disconnect external voltages and secure against unintended activation. - Isolate the complete installation. - Remove the wiring to all externally connected components. - Disassemble the wiring centre and if necessary dispose it properly. 4

EN 5

EN 6

EN 7

EN Follow REHU Underfloor: Our verbal and written application engineering advice is based upon experience and the best of our knowledge. However it is to be regarded as non-binding information. Working conditions and use under conditions for which the product was not intended and over which we have no influence exclude any claim resulting from our information. We recommend that a suitable check is made as to whether the REHU product is suitable for the envisaged purpose. pplication, use and processing of the products is carried out beyond the scope of our control and are therefore carried out exclusively at your own responsibility. If liability should still apply, then this is restricted, in the case of all damage, the value of the goods supplied by us and used by you. Our warranty applies to the consistent quality of our products as per our specification and in accordance with our general terms and conditions of delivery and payment. This document is protected by copyright. ll rights based on this are reserved. No part of this publication may be translated, reproduced or transmitted in any form or by any similar means, electronic or mechanical, photocopying, recording or otherwise, or stored in a data retrieval system. UK HED OFFICE Rehau Ltd, UK Head Office, Hill Court, Walford, Ross-on-Wye, Herefordshire HR9 5QN Phone: 01989 762 600 Fax: 01989 762 601 UK & IRELND SLES OFFICE London, REHU Ltd, The uilding Centre, 25 Store Street, London WC1E 7T Phone: 0207 580 6155 Fax: 0207 307 8595 Slough, Units 5 J & K, Langley usiness Centre, Station Road, Langley, Slough SL3 8DS Phone: 01753 588500 Fax: 01753 588501 Manchester, rinell Drive, Irlam, Manchester M44 5L Phone: 0161 777 7400 Fax: 0161 777 7401 Glasgow, Phoenix House, Phoenix Crescent, Strathclyde usiness Park, ellshill, North Lanarkshire ML4 3NJ Phone: 01698 503700 Fax: 01698 503701 Dublin, 9 St. Johns Court, usiness Park, Swords Road, Santry, Dublin 9 Phone: 00353 (0)1 8165020 Fax: 00353 (0)1 8165021 8 www.rehau.uk/neafamily REHU Ltd Subject to technical changes. 954619 EN 04.2016