RECT-STx-XXX and RECT-STx13-XXX Triple Lamp Operational and Programming Instructions

Similar documents
Operational & Programming. Instructions Manual 930L. Lightbar Series

ILW2. Item ref: UK User Manual IN-LINE WIRELESS CONTROLLER FOR SINGLE COLOUR LED TAPE

Manual for WMR-252 built-in receiver with universal dimmer

SMART Blue Smart Switch

ADVANCED USER MANUAL

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

STX Stairs lighting controller.

BLOCK OCCUPANCY DETECTOR

24 CHANNEL DIMMER CONSOLE USER MANUAL

USER'S MANUAL. ADJ R Junostraat EW Kerkrade

Atlas Drop In Decoder

Lecture 14: Computer Peripherals

INSTALLATION & OPERATION MANUAL 1000/1050/1051 Series Lightbars

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

Luminaire installation box Surface-mounted box Ceiling installation box

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

Lineum Star Split Phantom. Model ULB28. Dual Color Undercover Interior LED Lightbar PLIT507 REV. B 2/19/16

A summary of all menu lines available in self-diagnostic mode is shown below.

Aspect 2 Circuit Digital Scene Control

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Gamma instabus. Technical product information

T Series LED Remote Controller

Inspire Station. Programming Guide. Software Version 3.0. Rev A

Scoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

T Series LED Remote Controller

Light Commissioning Tool (CTTOOL) Operation Instructions

Casambi Smart Switching

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

This guide gives details of the effects available on the FX selection DMX channels 15 and 17 in the MAC Aura.

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

SceneStyle2 User Guide

TEMPI FCC: Limited Warranty:

Wireless Symphony LED Remote Controller with Screen Manual

KONTROL channels DMX controller USER MANUAL. For safety, please read this user manual carefully before initial use.

Professional-Practice

Light-It Decoder p/n Lighting decoder w/built-in white LED

The feature SMART Switch makes it possible to use ordinary wall switches as dimmers or for retrieving scenes set up before.

Comfort System T-32-P Universal Thermostat. Operation Manual

Night Hawk Firing System User s Manual

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

General FAQs Status as of: 22/10/2018

Nixie Clock Type Nixie Maestro

A digital version of this document is available to download and submit online at ADDRESS POST CODE

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

American DJ. Show Designer. Software Revision 2.08

KNOBS. REPEATS Controls the feedback amount for the heads that have their feedback enabled. ECHO LEVEL

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

FWD8000 Dante enabled four wire box

RGB CONVERTER SPECIFICATION. Car Solutions -. MODEL: RGB-LE-V3 -. PRODUCT CODE : RB www. car-solutions.com

Simple Way To Brighten Up A 17 Computer Monitor Picture Tube

013-RD

Touch Panel RGB LED Controller Part No. touch-panel-rgb

Dual PAL or NTSC Video to RGB Converter (One way) with 12V Relay Switch Operation Manual

araya Light Commissioning Tool Operation Guide DISCONTINUED - NO LONGER AVAILABLE

car-solutions.com GVIF Interface v7 for Nissan & Infiniti Specification Release date : Model : QVL-GF08-V7 / Product code : GF

Access Control Keypad for MK-DV, JB-DV

STAGE 2412 DMX 24 CHANNELS DMX CONSOLE FOR CONVENTIONAL LIGHTING

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

SM DMX LIGHTING CONTROLLER OWNERS MANUAL. May 19, 2009

English. Light Operator 24 USER'S MANUAL. Please read before use

INSTALLATION AND OPERATION MANUAL

Registers type ILR7XX and ILR7XXT

POINTS POSITION INDICATOR PPI4

Revision History. SDG2000X Firmware Revision History and Update Instructions

randomrhythm Bedienungsanleitung User Guide

Valcom Wired Digital Clock

Operation Guide 6022 ENGLISH

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Smart-Encoder : Optical Incremental

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

Scoreboard Operator s Instructions MPCX Volleyball Control

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

Installation Instructions

ATTENTION YOUR NEW KEY FOBS WILL NOT WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM

Operating Manual. Basic Control BC16. two-channel for eco moon

MATE3 Owner s Manual Addendum

C O B A R 18R U s e r G u i d e P a g e 1. User Guide COBRA 18R. Wireless Firing System.

Nixie Clock Type Quattro'

Techni-Lux. COMMANDER 24&48 24&48 Ch DMX Controllers USER'S MANUAL. Please read before use V1.1

PC/HDTV to PC/HDTV converter (CP-251F)

15 Series - Dimmer

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

1ENGLISH P R O Thanks for your reliability on us having acquired a product WORK. We hope it provides you a long and reliable service. The STAGE is a l

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Star Series Star Floor Kit (CLSSFK25-50 or CLSSFK50-50) LED driven Fiber Optic Lighting

Operation Manual. Model: CFR-2027 Dimmable Energy Saving Light bulb (Receiver built-in)

PCM-24 Press Feed Controller

Arduino Nixie Clock Modular Rev3

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

BBV REAL TIME HQ DISPLAY QUAD MANUAL

21 Channel Light Show PWM LED Controller with Remote Control

GSCmini - Pneumatic Timer Based Valve-Gate Sequence Controller lnstruction Manual

OWL micro+ WIRELESS ELECTRICITY MONITOR

MultiSystem Converter with built-in TBC/Genlock ID#488

Xanura Programmeer Unit Type PUX

Transcription:

RECT-STx-XXX and RECT-STx13-XXX Triple Lamp Operational and Programming Instructions The TOMAR iled RECT-STx series LED warning lamp features 25 programmable flash rates with 9 programmable color pattern selections and can be synchronized with any of the TOMAR iled family of LED warning lamps. Wires and Functions BLACK YELLOW RED BLUE RED & BLUE WHITE Connect to GROUND Sync/Enter Programming Mode/Pattern Select Mode 1 flash pattern Mode 2 flash pattern Mode 3 flash pattern Steady Burn Electrical Input Voltage +12VDC/+24VDC Installation to be completed with wire rated for 125% of amperage draw. Current draw: Mode 12.8Vdc 24Vdc steady blue 0.75A 0.44A steady red 0.57A 0.33A steady white 0.78A 0.45A Mode 1 default (neobe 150 phase 0, Red LED) 0.21A 0.13A Mode 2 default (neobe 75 phase 0, Blue LED) 0.28A 0.19A Mode 3 default (single 120 phase 0, White LED) 0.40A 0.24A Selecting a Flash Pattern Mode For the Mode 1 Flash Pattern: Apply +12VDC/+24VDC to the RED wire. The currently selected Mode 1 flash pattern will appear. For the Mode 2 Flash Pattern: Apply +12VDC/+24VDC to the BLUE wire. The currently selected Mode 2 flash pattern will appear. For the Mode 3 Flash Pattern: Apply +12VDC/+24VDC to the RED and BLUE wires. The currently selected Mode 3 flash pattern will appear. This mode overrides the Mode 1 and Mode 2 flash patterns. Selecting Steady Burn Mode Apply +12VDC/+24VDC to the WHITE wire. The LEDs will turn on Steady. This mode overrides the Mode 1, Mode 2 or Mode 3 flash patterns, if they are active. 1

Assigning a Flash Pattern and Color Pattern for Mode 1, Mode 2 or Mode 3 Enter Programming for the desired Mode For the Mode 1 Flash Pattern: Apply +12VDC/+24VDC to the YELLOW and RED wires at the same time. All LEDs will flash 3 times in Color 1 to indicate you have entered Remove the YELLOW wire from Leave the RED wire connected to After the unit flashes 3 times, the currently selected Mode 1 flash pattern will appear. For the Mode 2 Flash Pattern: Apply +12VDC/+24VDC to the YELLOW and BLUE wires at the same time. All LEDs will flash 3 times in Color 2 to indicate you have entered Remove the YELLOW wire from Leave the BLUE wire connected to After the unit flashes 3 times, the currently selected Mode 2 flash pattern will appear. For the Mode 3 Flash Pattern: Apply +12VDC/+24VDC to the YELLOW, RED and BLUE wires at the same time. All LEDs will flash 4 times in Color 1 to indicate you have entered Remove the YELLOW wire from Leave the RED and BLUE wires connected to After the unit flashes 4 times, the currently selected Mode 3 flash pattern will appear. Select a Flash Pattern for the Mode Tap the YELLOW wire once to +12VDC/+24VDC, then release. Repeat until the desired flash rate is selected. Tap the YELLOW wire twice, in less than one second, to Repeat until the desired flash rate is selected. To RESET to Factory Default: While still in programming mode, touch and hold the YELLOW wire to +12VDC/+24VDC for at least 3 seconds. All LEDs will flash 2 times. Release the YELLOW wire. The flash pattern and color will be reset to factory default. This will also return to full brightness. 2

Select a Color Pattern for the Mode Tap the WHITE wire once to +12VDC/+24VDC, then release. Repeat until the desired color pattern is selected. Tap the WHITE wire twice, in less than one second, to Repeat until the desired color pattern is selected. Select Dimming for the Mode To toggle dimming: While still in programming mode, apply +12VDC/+24VDC to the WHITE wire. Hold for approximately 3 seconds. All LEDs will flash 2 times. Release the WHITE wire. The DIM setting will be toggled for the mode. Repeat to return to full brightness. Exit Programming Remove power from all wires Assigning a Color for Steady Burn Mode Enter Programming for the Steady Burn Mode For the Steady Mode Color: Apply +12VDC/+24VDC to the YELLOW and WHITE wires at the same time. All LEDs will flash 4 times in Color 2 to indicate you have entered Remove the YELLOW wire from Leave the WHITE wire connected to After the unit flashes 4 times, the currently selected color in Steady Burn Mode will illuminate. Select a Color for the Steady Burn Mode Tap the YELLOW wire once to +12VDC/+24VDC, then release. Repeat until the desired color is selected. Tap the YELLOW wire twice, in less than one second, to Repeat until the desired color is selected. 3

To RESET to Factory Default and Toggle Dim: While still in programming mode, apply +12VDC/+24VDC to the WHITE wire. Hold for approximately 3 seconds. All LEDs will flash 2 times. Release the YELLOW wire. The color will be reset to factory default. Additionally, this will toggle the DIM setting. Repeat the step above to return to normal brightness. Exit Programming Remove power from all wires Synchronizing Lamps: RECT-STx Series First, select a flash pattern and program each lamp to the same flash pattern. If alternating lamps are desired, program one lamp to a PHASE 0 flash pattern and the second lamp to the corresponding PHASE 1 flash pattern. See Flash Patterns below. To synchronize lamps, connect all YELLOW wires together. Only 10 devices can be connected together for synchronization. The maximum wire distance between the furthest units is 100 feet. For best results connect the BLACK wire to GROUND. Note: When synchronizing lamps, YELLOW wire is for Sync mode only. Do not connect the YELLOW wires to power or ground. Apply +12VDC/+24VDC to the RED and/or BLUE wires to activate the desired flash pattern Mode. Flash Rates SINGLE FLASH = 1 PULSE PER BURST DOUBLE FLASH = 2 PULSES PER BURST NEOBE FLASH = 5 PULSES PER BURST Flash Patterns 1. NEOBE FLASH 150 FPM PHASE 0 MODE 1 Default 2. NEOBE FLASH 120 FPM PHASE 0 3. NEOBE FLASH 75 FPM PHASE 0 MODE 2 Default 4. DOUBLE FLASH 250 FPM PHASE 0 5. DOUBLE FLASH 125 FPM PHASE 0 6. DOUBLE FLASH 75 FPM PHASE 0 7. SINGLE FLASH 375 FPM PHASE 0 8. SINGLE FLASH 150 FPM PHASE 0 4

9. SINGLE FLASH 120 FPM PHASE 0 MODE 3 DEFAULT 10. SINGLE FLASH 75 FPM PHASE 0 11. NEOBE FLASH 150 FPM PHASE 1 12. NEOBE FLASH 120 FPM PHASE 1 13. NEOBE FLASH 75 FPM PHASE 1 14. DOUBLE FLASH 250 FPM PHASE 1 15. DOUBLE FLASH 125 FPM PHASE 1 16. DOUBLE FLASH 75 FPM PHASE 1 17. SINGLE FLASH 375 FPM PHASE 1 18. SINGLE FLASH 150 FPM PHASE 1 19. SINGLE FLASH 120 FPM PHASE 1 20. SINGLE FLASH 75 FPM PHASE 1 21. STEADY BURN 22. MULTI-FLASH 1 PHASE 0 (PATTERNS 1, 4, 7, 1 REPEAT) 23. MULTI-FLASH 2 PHASE 0 (PATTERNS 3, 5, 8, 10 REPEAT) 24. MULTI-FLASH 1 PHASE 1 (PATTERNS 11, 14, 17, 11 REPEAT) 25. MULTI-FLASH 2 PHASE 1 (PATTERNS 13, 15, 18, 20 REPEAT) Color Pattern Note: When selecting a multiple color pattern, the device will cycle through the indicated colors in the shown order. For Phase 0 Flash Patterns 1. COLOR 1 (FACTORY DEFAULT MODE 1) 2. COLOR 2 (FACTORY DEFAULT MODE 2) 3. COLOR 3 (FACTORY DEFAULT MODE 3 + STEADY BURN MODE) 4. COLOR 1 & 2 5. COLOR 1 & 3 6. COLOR 2 & 3 7. COLOR 1 & 2 & 3 8. COLOR 2 & 3 & 1 9. COLOR 3 & 1 & 2 For Phase 1 Flash Patterns 1. COLOR 1 2. COLOR 2 3. COLOR 3 4. COLOR 2 & 1 5. COLOR 3 & 1 6. COLOR 3 & 2 7. COLOR 3 & 2 & 1 8. COLOR 1 & 3 & 2 9. COLOR 2 & 1 & 3 5