ST800K-U Optical Power Meter. User Manual V1.0

Similar documents
Fiber tester. Optical power meter XL-FM141. Optical power meter User s Manual

OTS-300 Express Series Power Meters/Sources and Testers

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Fiber Meter. Specification & User Manual

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Light Source. Specification & User Manual

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Options: - Master Patchcord - Launch cable - Set of optical adapters

AXS-200/350 OPTICAL LOSS TEST SET. part of the SharpTESTER Line LAN Applications

DS2460Q QAM Analysis Meter

Datasheet: SimpliFiber Pro

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

JD725A Cable and Antenna Analyzer - Dual Port

Compact live fiber identifier with integrated optical power meter

LTS-1500 Fiber Optic Test Set Operating Instructions

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

OPERATIONS GUIDE OWL

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Datasheet: MultiFiber Pro Update

OPTICAL POWER METER WITH SMART DETECTOR HEAD

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

Fiber Optic Meter Fiber Optic Source

2 GENERAL DESCRIPTION

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

XCOM1002JE (8602JE) Optical Receiver Manual

Advanced Test Equipment Rentals ATEC (2832)

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Datasheet: CertiFiber Pro Optical Loss Test Set

Datasheet: MultiFiber Pro

OFI Optical Fiber Identifier User s Guide

Portable TV Meter (LCD) USER S MANUAL

Optical Channel Analyzer

FTK200. Users Guide. Optical Fiber Test Kit

User's Guide to the PROLITE-30B

Versiv makes you money every time you use it.

USER'S GUIDE TO THE FHP2P01

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Multi Application Test System

Datasheet: CertiFiber Pro Optical Loss Test Set

Advanced Test Equipment Rentals ATEC (2832)

MXAN-LN series 1550 nm band Analog Intensity Modulators

CMA4000i Optical Test System

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Product Introduction. Duplexer Box MN2555A. Signal Analyzer MS2830A. Ver.1.0

Datasheet: CertiFiber Pro Optical Loss Test Set

Sidelighter TM Optical distance to fault measurement module

Model 4700 Photodiode Characterizer

Fiber Optic GaAIAs LED OPF32_, OPF34_ Series OPF37_, OPF39_ Series OPF67_, OPF69_ Series

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

SimpliFiber Pro. Users Manual. Optical Power Meter and Fiber Test Kits

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

OP940. Insertion Loss & Return Loss Meter Instruction Manual. (Also supports the OP725 Integration)

MXAN-LN series 1550 nm band Analog Intensity Modulators

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

HDMI Extender via 4 Single-mode fibers 4 x LC Connector Extends HDMI + RS232 full-duplex up to 1500 meters

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

KI7400C/7800C Series Optical Light Source KI7600C Series Optical Power Meter KI7300C/7700C Series Optical Loss Test Set

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

User s Manual of Signal Level Meter TABLE OF CONTENTS

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

MPX and MPZ series Low frequencies to 40 GHz Phase Modulators

OLP-34/-35/-38 Optical Power Meter. Operating Manual BN 2302/ English

GFT Channel Digital Delay Generator

FIBER QUICKMAP. Users Manual. Multimode Troubleshooter

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

SECTION 4 TABLE OF CONTENTS

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Datasheet: SimpliFiber Pro

Yellow Frog. Manual Version 1.1

SHF Communication Technologies AG,

7880: A new family of TV Meters to meet the requirements of the XXI century!

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

OPTICAL TEST EQUIPMENT

MTS/T-BERD Platforms WDMPMD Module

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber

AQ2200Series. Ideal Measurement Solution for Optical Devices and Optical Transmission Systems. Multi Application Test System

MTS/T-BERD 8000 Platform

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

Ethernet Media Converters

Agilent FieldFox RF Analyzer N9912A

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

DTX. Users Manual. Fiber Test Kit

MPX / MPZ series. Low frequencies to 32 GHz Phase Modulators. Modulator. Features. Applications. MPX-LN series Performance Highlights

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

CBF500 High resolution Streak camera

OTX Optical Transmitter. Operation Instructions

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Keysight FieldFox Microwave Analyzers

Single mode 9/125µm, duplex

FTE6100 Tunable Laser Source User's Guide

DATA SHEET. Four (4) fibers Detachable HDMI Extender, HDFX-150-TR

Transcription:

User Manual V1.0

Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10. Appendix C...12

1. Summary ST800K-U Optical Power Meter, a new generation of high-performance optical network test meter, with the characteristics of excellent performance and fast field test, has adopted the latest laser exploration and processing technology. It is an integrated optical power meter aimed at optical network operation, maintenance, equipment research and development. It can be used to test optical power within the range of 800~1700nm wave length, with the unit as nw, µw, mw, db, dbm. Its display resolution level and test accuracy are high. There are 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, six kinds of wavelength calibration points. It can be used for linearity and non-linearity test and display both direct and relative test of optical power. The meter is small, light and easy to carry with large LCD screen. It can be widely used in the test of LAN, WAN, metropolitan network, CATV net or long-distance fiber net and other situations. It can be used to test fiber loss accurately, to check the fiber continuity and to help to evaluate the transmission quality of fiber chain with the laser source. 1

2. Functions ST800K-U Optical Power Meter 2.1 Multi-wavelength precise measurement 2.2 Absolute power measurement of dbm or xw 2.3 Relative power measurement of db 2.4 Auto off function 2.5 270, 330, 1K, 2KHz frequency light identification and indication 2.6 Low voltage indication 2.7 Automatic wavelength identification (with the help of light source) 2.8 1000 groups of data storage 2.9 USB port upload 2.10 Real-time clock 2.11 650nm VFL output 2.12 Applicable to versatile adapters (FC, ST, SC, LC) 2.13 Handheld, large LCD backlight display, easy-to-use 3. Specifications 3.1 Wavelength range (nm): 800~1700 3.2 Detector type: InGaAs 3.3 Measurement range (dbm): -50~+26, -70~+10 2

3.4 Uncertainty: ±5% 3.5 Resolution: Linearity display: 0.1% Logarithm display 0.01 dbm 3.6 Auto off duration (min): 10 3.7 Battery: 4 pcs AA batteries (lithium battery is optional, if you has special need please inform us in advance, or else, we just provide standard AA batteries.) 3.8 Battery-hold duration (h): no less than 75 (according to the battery volume) 3.9 Operating temperature (): -10~+50 3.10 Storage temperature (): -30~+60 3.11 Weight (g): 430 (without batteries) 3.12 Dimensions (L*W*H, mm): 200 90 43 3

4. Layout ST800K-U Optical Power Meter 4

5. Operation ST800K-U Optical Power Meter 1. Turn on/turn off To turn the meter on press the key for 3 seconds. This meter defaults to a 10 minutes Auto Off function. When this meter is on, a short press of the key switches off the Auto-off function. Pressing the key again switches the Auto-Off function back on. A Short press of the button, turns the meter off. 2. dbm key Press this button to show absolute optical power measurement value. 3. λ key: wave length choice key You can choose one of six wave lengths; The default wavelength is 1310nm the others are 850nm, 1300nm, 1490nm,1550nm,1625nm.They are selected by pressing the λ key until the chosen wavelength is displayed on the LCD screen 4. REF key Press this key, LCD shows relative power value. see Appendix A, B & C to reference test cables 5. key: open/off backlight Press this key to control the backlight on or off. 5

6. 270, 330, 1K, 2KHz frequency light identification When the entering light is 270, 330, 1K & 2KHz modulated light, the meter identifies the frequency automatically and shows it on the LCD. This function co-operates with the light source. 7. Automatic wavelength identification Works with the light source to automatically identify wavelength from the source. 8. VFL Function Cycle press shortly to realize the continuous light source output, pulse output and off function. 9. Clock Setting Long press to enter into the clock setting interface, the current set bit will blink, and then user can change time by pressing, ; choose the modified bit through λ key, REF key; press to save and exit. 10. Save Record Press shortly to enter into the record storage interface, the record number for storing will be displayed on screen; and then press to store the record and back to test state; press shortly to exit the record storage, and the record will not be stored. 6

11. Browse Record Press shortly to enter into the record browse interface; browse the record through and ; press λ key shortly to delete the current record; and press shortly to exit. 6. Maintenance 1. Please keep the sensor surface clean, do not use dirty or non-standard adapters, do not insert into the port a poorly polished connector, otherwise, it will damage the sensor end. 2. Please carefully replace adapters for different links. The spare adapters should be stored with their caps and hermetically to avoid dust contamination. 3. Please cover the dustproof cover to keep the interface clean when the optical power meter is not used. Please do not put the sensor in the air, or something of test error will be caused because of the dust. 4. Please clean the sensor end regularly. 5. In order to make the service time of battery as long as possible. Please take out the battery if it is not used for long. 7

Faults Reasons Solutions LCD display is dark. Low voltage. Replace battery or charge. Big error for test result. Sensor s surface is dirty. Low voltage Clean sensor, Replace battery or charge. There is nothing displayed when switch on this meter. The battery is under voltage/other reasons. Replace battery or charge 7. Faults & Solutions ST800K-U Series Model No. Power test range(dbm) Adapter interface ST800K-UA -50~+26 FC,ST,SC ST800K-UB -50~+26 FC,ST,SC, LC ST800K-UC -70~+10 FC,ST,SC ST800K-UD -70~+10 FC,ST,SC, LC Battery Rechargeable Li-ion Battery Rechargeable Li-ion Battery Rechargeable Li-ion Battery Rechargeable Li-ion Battery 8

8. Appendix A Testing Loss of Installed Fiber Optic Cable Plant 1) Test Diagram 2) Test Procedure --Turn on equipment and allow time to warm-up --Attach launch cable to source. This should remain connected to source for the duration of the test. --Clean all connectors and mating adapters. --Set 0 db reference by pressing REF key. Meter may be set to read 0 db. --Attach source/ref cable and meter/ref cable to the cable plant under test and make loss measurement. 9

10 ST800K-U Optical Power Meter

9. Appendix B ST800K-U Optical Power Meter Testing Loss of Fiber Optic Cables, Single-Ended 1) Test Diagram 2) Test Procedure --Turn on equipment and allow time to warm-up --Attach launch cable to source. This should remain connected to source for the duration of the test. --Clean all connectors and mating adapters. --Set 0 db reference by pressing REF key. Meter may be set to read 0 db. --Attach source/ref cable and meter/ref cable to the cable plant under test and make loss measurement. 11

--Reverse cable and test again. ST800K-U Optical Power Meter 10. Appendix C Measuring Optical Power in Fiber Optic Systems 1) Test Diagram 2) Test Procedure --Turn on equipment and allow time to warm-up 12

--Set meter to wavelength of source and dbm to measure calibrated optical power meter. --Clean all connectors and mating adapters. --Attach reference cable to source if testing source power or disconnect cable from receiver. --Attach power meter to end of cable and read measured power. Note: A reference cable or known good patchcord is used for testing source power coupled into a fiber. Receiver power is tested by disconnecting the system cable connecting to the receiver and attaching it to the power meter to measure power. 13