WECON LX3V-2PT2DA BD Board

Similar documents
WECON LX3V-2TC2DA BD Board

WECON LX3V-2PT-BD Module

LX3V-2PT-BD User manual

WECON LX3V-2TC-BD Module

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

USER S MANUAL. FX2N-8AD Analog input block

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

C200H-AD002/DA002 Analog I/O Units Operation Guide

FX2N-2AD SPECIAL FUNCTION BLOCK

MicroLogix 1200 Thermocouple/mV Input Module

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Analogue output module DAO 081

FX2N-2DA SPECIAL FUNCTION BLOCK

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

MELSEC iq-f FX5 User's Manual (Analog Control - Intelligent function module)

FX0N-3A SPECIAL FUNCTION BLOCK

T775U Series 2000 Electronic Stand-Alone Controller

Panel-mounting thermostats, type series EM

T775U Series 2000 Electronic Stand-Alone Controller

User s Manual Model WF100 Extension Cable for EXA100

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

SAFETY PRECAUTIONS. (Read these precautions before using this product.)

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

10 SERIES. Light dependent relays A

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Type: DILM25 10(24V50HZ) Article No.:

90 Series - Sockets and accessories for 60 series relays

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Process Transmitter RMA 422

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

MELSEC-L Digital-Analog Converter Module User's Manual -L60DA4 -L60DAVL8 -L60DAIL8

SA1J-F: Full Color Fiber Optic Sensors

263 Series LED Bargraph Indicator and Controllers

CM1-AD08V 0~5V, 1~5V, -10~10V, 0~10V An input signal is converted to a digital value from 0 to or from 8000 to 8000.

Set Point Controller OC557. Operator s Manual

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

It will cause malfunction if the monitor is operating with unspecified power supply

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER

Capacitive sensor BCT5-S18-UP6X2T-H1151

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Displacement Measuring System for Cylinder Series OSP-P

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

CC-Link IE Field Network Analog-Digital Converter Module User's Manual -NZ2GF2BN-60AD4 -NZ2EX2B-60AD4

Product Specifications

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Signet 2250 Hydrostatic Level Sensor

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Datasheet - SRB-E-201ST

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD


E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Minicontactorrelay,2NO/2NC,DCoperated

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

AS09..S 3-pole Contactors - Spring Terminals

Sensor technologies Distance measuring sensors Series SM6. Brochure

Datasheet - SRB301LC 24VAC/DC

T775L Series 2000 Electronic Stand-Alone Staging Controller

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Magnetic Sensor - Incremental EHP

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Power Injector 1520 Series

KAA-4R4V. KNX LED actuator / dimmer

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

ArmorPOINT RTD and Thermocouple Input Modules

HS-509 VIBRATION TRIP MODULE

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Operating Instructions

LONWORKS Fibre Optic Converter

SQM40/41 Actuators for air and gas dampers

LED Driver Linear / area fixed output

Transcription:

WECON LX3V-2PT2DA BD Board Website: http://wwwwe-concomcn/en Technical Support: liux@we-concomcn Skype: fcwkkj Phone: 86-591-87868869 Technical forum: http://weconfreeforumsnet/

Ⅰ Mounting instruction Make sure to power off the PLC before mounting the 2PT2DA module and remove the top cover of PLC, screwed to the PLC Caution: when output current, make sure that the load resistance should be less than 500Ω, otherwise the output will be lower Warring: make sure to power off the PLC before mounting or removing the BD module Ⅱ The features of LX3V-2PT2DA-BD It adds two analog inputs and two analog outputs The module is mounted on top of PLC, so there is no need to change the PLC installation area Digital to analog conversion is performed by PT100 in LX3V-2PT2DA-BD, and the converted digital value is stored in a special registers However, the characteristics of the analog to digital converter can not be adjusted Address assignment in the following table Address M8112 M8113 M8114 M8115 D8112 D8113 D8114 D8115 Description The flag of RTD type in CH1 OFF: RTD Type is PT100 The flag of RTD type in CH2 OFF: RTD Type is PT100 The flag of CH3 output mode OFF: current output mode(4-20ma:0-2000) The flag of CH4 output mode OFF: current output mode(4-20ma:0-2000) CH1 s temperature at 01 units CH2 s temperature at 01 units The value of CH3 The value of CH4 ON: turn off ⅢTerminal Description and shape

The detail information of each terminal as following form table shows, IN-2PT sensor type: 2 or 3 wires PT100 L1+ First channel PT100 signal input (+) L1- First channel PT100 signal input (-) L2+ Second channel PT100 signal input (+) L2- Second channel PT100 signal input (-) VI- Common OUT - 2DA Output current range:4~20ma I1+ First channel current output (+) I1- First channel current output (-) No connection I2+ Second channel current output (+) I2- First channel current output (-) IV Specification 1 General Specifications: same as PLC main unit 2 Power Specifications: Powered by PLC 3 Performance Specifications: Item Explanation Analog circuitry Digital circuitry DC 24V ±10%, 50mA DC 5V, 90mA (From the PLC internal power supply) Celsius Read data by buffers

Analog input signal Sensor current PT100 sensor, 3 wires, 4 channels (CH1, CH2, CH3, CH4), 3850PPM/ 1mA Compensation range -100-600 Digital output -1000-6000 12 bits total, 11 bits for data and 1 bit for sign Accuracy 02-03 Overall accuracy ±1% Conversion rate 50ms Conversion characteristics - V Wiring Explanation: 2-wire PT100: when using channel 1, short-circuit L1+ and VI-, connect PT100 s 2 wires to L1+ and L1- respectively the same setting in channel 2 L1+ 3-wire PT100: when using channel 1, two same color wires, connected to the L1- and VI-, the third one connect to Warning: Please cut off the power firstly, before installation / removal of expansion boards to avoid electric shock or damage to the product Note: number 1 Stay away from high-voltage cables to avoid interference or surge; 2 Grounding is required, but please do not share the ground site with high-voltage cable 3 Do not weld any cable ends, and make ensure that the number of connecting cables, no more than a predetermined 1 Cable Connecting output device by AWG25-16 Terminal maximum tightening torque is 05 to 06 Nm Types of cables and cross-sectional area

Type Cross-sectional(mm²) End AWG26 01288 Stranded cable: Strip the sheath, matching core wire connection cable AWG16 1309 Single cable: Strip the sheath, connecting cables 2 I/O mode PT100 input mode Current output mode Ⅵ Examples The value of each chanel s PT100 is storaged in the registers(d8112, D8113) in the form of digital For output, in each "END" instruction, M8114 and M8115 converts the digital value into an analog output

1 Basic Programming Note: M8112 and M8113 are used to analog to digital conversion for CH1 and CH2; 2PT only supports PT100; 2DA only supports current analog output; When M8112-M8115 are ON, the channels will not work, all showe 0 ; Don t try to change the value in D8112 or D8113, when finished the A/D conversion; Example: The following project sets CH1 and CH2 as PT100 input, and the value is storaged in D0 and D2 The following projects set current output mode, and convert the data in D0 and D2 to analog value and output 2 Application Because LX3V-2PT2DA-BD no offset and gain function, so if the value is outside the range of values, it requires to use the four operations to complete the conversion Note: Because the use of additional programming instructions, so the accuracy and resolution of analog to digital conversion are changed; Original range of the analog output will not change; RTD input mode: In RTD input mode, 2PT covert a analog value to a digital value in degrees Celsius If in the program was degrees Fahrenheit as a unit it needs to be converted to Celsius value Fahrenheit and Celsius conversion formula, Fahrenheit = Celsius * 9/5 + 32, the unit is 01

Current output mode: In current output mode, 2DA covert digital value 0-2000 into an analog value 4-20mA If the range of digital in the program was 0-A, it must be converted to 0-2000