KGS-1 START UP TRANSFORMER

Similar documents
INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

TRF STEP-DOWN TRANSFORMER USER MANUAL

FIB Operating Procedure. Effective Date: 08/14/2012 Author(s): Jiong Hua Phone:

AUTO-LIT. vs advertisers. Catalogue of OLUMINESCENT COMMERCIAL PURPOSE.

Intelligent solutions for Onshore Power Supply

ELECTRICAL SAFETY INSPECTION REPORT

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

V25 V25+ WS WS WS WS V27 WS-65517

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Early Literacy Programme. Early Literacy Programme

Table of Contents - 2 -

Digital Economy Seven Programmer

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

ULTRALOW TEMPERATURE FREEZERS -86 C

Transmission App for Real Time Monitoring and Growth

Light Emitting Diodes (LEDs)

MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Logic Controls LV3000 VGA Connected Virtual Pole Display

Matthew Flinders Theatre

TV2K - TXT SERVICE MANUAL COLOUR TELEVISION RECEIVER SECIFICATION

12 Channel Media Splitter MS12 Mk2 User manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Logo Usage Guide. CADD Centre Corporate Identity

Electrical Depth Work

Target Interface / Construction Compliance Inspection Checklist

Mewar University Chittorgarh, Rajasthan. Ph.D Thesis Preparation Manual

Entry Level Assessment Blueprint Television Production

Dr. Fred Speckeen Theatre. Information and Technical Specifications

APPENDIX A SITE: MAT WAS IT? The Indian Satellite Instructional Television Experiment (SITE) was

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

Instructions and answers for teachers

2. ARRANGEMENT OF THE CONTENTS OF THESIS

RESOLUTION MSC.95(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR DAYLIGHT SIGNALLING LAMPS

AREA CODE EXHAUST AND RELIEF. Questions and Answers

Explorations 2: British Columbia Curriculum Correlations Please use the Find function to search for specific expectations.

AT&T January, 2012 Revised December, 2018 TABLE OF CONTENTS SECTION 1--INTRODUCTION...1-1

Asia-Europe Meeting (ASEM)

Off Site Maintenance Goes Mobile Electronic Cellular Time Switch

ICS Digital Menu. Installation Guide Version 1.1

Flicker Caused by Operation of Industrial Technology

Installation Guide VL-MV10. Model No.

BRAND STANDARDS GUIDE

INTERNATIONAL STANDARD

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

THE NOVA PHONOMENA MUSICAL SURROUNDINGS PRESENTS: PHONOGRAPH PREAMPLIFIER OWNER S MANUAL. Musical Surroundings. status

clipping; yellow LED lights when limiting action occurs. Input Section Features

Broadcast LCD Displays

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Fluke 279 FC True-rms Thermal Multimeter

Obtained from Omarshauntedtrail.com

GATES AMPLIFIERS. Plug -in. Audio. Solid- Statesman Series HARRIS INTERTYPE CORPORATION. Six Premium Quality Transistorized Products

LOGO MANUAL. Definition of the basic use of the logo

INSTRUMENT CATHODE-RAY TUBE

LUT Luminescence scanners: Seeing what no-one else can

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

PRINCIPLES AND APPLICATIONS

The Martin Wood Lecture Theatre. Notes for Speakers on the use of the Audio/Visual equipment

Indoor Linear 80W Driver SI-C215280N2KR

FAQ for Tropicana Field:

Faiveley DT Xebra Mobile DVR

User Manual. Digital Stroboscope Tachometer. Model and Model

1. Product Summary. 2. Features, Performance Characteristics. 3. Block Diagram

Model: DT-X92H 2. 9 Rack Mount Broadcast 3GSDI LCD Monitor. User Manual. Ver:V1.0.0V01. Please read this User Manual throughout before using.

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Model Camera System (CCTV) User Manual

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

Instrumentation Cables

Projectors EFFORTS FOR PROJECTOR QUALITY

Multifunction Digital Timer

MF-4000 WEIGHT BENCH OWNER S MANUAL

DIGITUS WALL MOUNT ENCLOSURE

The science class. Wednesday, September 5

Sample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology

Compact Module. Category 6 FTP Cabling System

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

CHM 110 / Guide to laboratory notebooks (r10) 1/5

Operation and Maintenance Guide Electric Needle Scalers

SM-10 SAT Level Meter User s Manual

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Specification. NGTS Issue 1 October 1993

Heating thermostat Series AMHs B Operating Instructions 11.06/

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Digital Display Monitors

ISLAND HALL TECHNICAL INFORMATION

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

HOUSE / TECHNICAL / FESTIVAL RULES

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

3M Sensored Termination (15 kv) QX-T15I-vi1-E

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Assembly. Front view. LEDs. Parametrization interface. Power Bus

USER & ENGINEER INSTRUCTION MANUAL

Surface-mounting thermostats ATH series

Standard Method of Test for Random Method of Sampling Hot Mix Asphalt (HMA) SCDOT Designation: SC-T-101 (08/13)

Transcription:

Template for item no. 1.i. Heading: white background with blue fonts & logo, rest: blue background with white fonts. KGS-1 START UP TRANSFORMER HV - 24.5 / 35 MVA, LV1,LV2-14 / 20 MVA, IV - 8.4 / 12 MVA 220 / 6.9 / 6.9 / 11KV HV - 64.3 / 91.9 Amps, LV1 & LV2 1172 / 1675 Amps, IV 629 / 440 Amps Y n y n 0y n 0 (d1) 25.26 KL 101.25 Tons SL.NO. OF TRANSFORMER: 120315-1 DATE OF COMMISSIONING: 23-10-1997 Template for item no. 1.ii. Heading: white background with blue fonts & logo, Rest: blue background with white fonts. KGS-1 GENERATOR TRANSFORMER 260 MVA 235 / 16.5KV HV - 639 Amps, LV - 9098 Amps Y n d11 IMPEDANCE: 14% OFWF 42 KL 233 Tons SL.NO. OF TRANSFORMER: 140101-1 DATE OF COMMISSIONING: 20-09-2000

Template for item no. 1.iii. Heading: white background with blue fonts & logo, Rest: blue background with white fonts. KGS-1 UNIT TRANSFORMER Dy n 1y n 1 M/s BHEL, BHOPAL, MADHYA PRADESH HV 24.5 / 35 MVA, LV1, LV2-14 / 20 MVA 16.5 / 6.9/ 6.9 KV HV - 858.3 / 1226.1 Amps, LV1, LV2-1172.8 / 1675.5 Amps TYPE OF COLLING: 19.75 KL 70.1 TONS SL.NO. OF TRANSFORMER: 6005330 DATE OF COMMISSIONING: 05-10-2000 Template for item no. 1.iv. Heading: white background, green fonts & blue logo,rest: green background with white fonts. KGS-2 GENERATOR TRANSFORMER 260 MVA 235 / 16.5KV HV - 639 Amps, LV - 9098 Amps Y n d11 IMPEDANCE: 14% OFWF 42 KL 233 Tons SL.NO. OF TRANSFORMER: 140101-2 DATE OF COMMISSIONING: 17-07-1999

Template for item no. 1.v. Heading: white background, green fonts & blue logo,rest: green background with white fonts. KGS-2 START UP TRANSFORMER HV-24.5 / 35 MVA, LV1,LV2 14 / 20 MVA, IV 8.4 / 12 MVA 220 / 6.9 / 6.9 / 11KV HV 64.3 / 91.9 Amps, LV1 & LV2 1172 / 1675 Amps, IV 629 / 440 Amps Y n y n 0y n 0 (d1) 25.26 KL 101.25 Tons SL.NO. OF TRANSFORMER: 120315-2 DATE OF COMMISSIONING: 06-11-1998 Template for item no. 1.vi. Heading: white background, green fonts & blue logo,rest: green background with white fonts. KGS-2 UNIT TRANSFORMER Dy n 1y n 1 M/s BHEL, BHOPAL, MADHYA PRADESH HV 24.5 / 35 MVA, LV1, LV2-14 / 20 MVA 16.5 / 6.9/ 6.9 KV HV - 858.3 / 1226.1 Amps, LV1, LV2-1172.8 / 1675.5 Amps TYPE OF COLLING: 19.75 KL 70.1 TONS SL.NO. OF TRANSFORMER: 6005332 DATE OF COMMISSIONING: 20-09-1999

Template for item no. 2 Quantity required: 10 nos. in English, 10 nos. in Hindi and 10 nos. in Kannada language. Colour: Red background with white fonts. ENTRY RESTRICTED PROHIBITED AREA Template for item no. 3, 4, 5 and 6. District language will include Hindi & Kannada. Colour: White background with signal red fonts.

Template for item no. 7. Quantity required: 25 nos. in English, 25 nos. in Hindi and 25 nos. in Kannada language. Colour: White background and black fonts.

Template for item no. 10. Quantity required: 30 nos. in English & 30 nos. in Hindi. White background, green fonts for DO S column texts, red fonts for DONT S column texts, black fonts for the rest. DO S BATTERY ROOM INSTRUCTIONS DONT S 1. USE PERSONAL PROTECTIVE EQUIPMENT WHILE WORKING ON BATTERIES LIKE GOGGLES, GLOVES, BOOTS ETC 2. ACID CARBUOY SHOULD BE HANDLED WITH SPECIAL CARE TO PRVENT BREAKAGES 3. USE A SIPHON TO TRANSFER ACID SAFELY 4. KEEP THE EXHAUST FANS RUNNING 5. MONITOR HYDROGEN CONCENTRATION IN BATTERY ROOM WHILE BOOST CHARGING IS ON 6. ENSURE PROPER POSITIONING OF BATTERIES ON THE RACK 7. STORE THE ACID CARBUOY ON ACID RESISTANT FLOORS ONLY 1. DO NOT STORE TOOLS AND LOOSE METALS NEAR BATTERIES 2. DO NOT CARRY METALLIC LADDERS OR LARGE METAL OBJECTS 3. DO NOT USE METAL BRUSH, EMERY PAPER ETC, TO CLEAN OBJECTS 4. DO NOT MAKE OR BREAK SERIES CONNECTION UNLESS BATTERY IS OPEN CIRCUITED 5. DO NOT ALLOW HYDROGEN CONCENTRATION TO EXCEED 1% V/V (25% OF LOWER EXPLOSION LIMIT) 6. DO NOT POUR WATER IN TO SULPHURIC ACID 7. DO NOT PERMIT OPEN FLAMES AND SMOKING BY ORDER, SME (E)