Type MG-6 Auxiliary Relay Class 1E

Similar documents
ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Time-Lag Relays. User s Handbook (General Model)

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

BE3-GPR GENERATOR PROTECTIVE RELAY

Systems Pow-R Breakers Renewal Parts and Accessories

MATE3 Owner s Manual Addendum

MILLITARY SPECIFICATION SHEET

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Wall-/Pipe-Mount Level Indicator

ALLEN BRADLEY TIMING RELAY

Type Contact form Model

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

MAP110 AC-DC Series Data Sheet

263 Series LED Bargraph Indicator and Controllers

Multifunction Digital Timer

SPECIFICATION NO NOTE

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

High performance circuit breakers

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

C E R T I F I C A T E O F C O M P L I A N C E

CAMTO LTD. Arc detecting system DC/AC

Generator protection relay

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Ordering details. Approval. Classification

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Solid-State Digital Timer

Magnecraft Power Relays

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

SAL Series Wireless Clock (V1)

Part-Turn Electric Multi-Turn Electric

1900/25 Vibration Monitor

GP-500 SERIES - Low Voltage

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Definite Purpose Contactors

Active UTP Transceiver Hub Installation Guide

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

Bulletin 190 IEC Modular Starter System

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

LAUREL ELECTRONICS, INC.

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Operating instructions Electronic preset counter Type series 717

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

EVC300i. Generator Automatic Voltage Regulator Operation Manual

www. ElectricalPartManuals. com l Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

AC1036. Definite Purpose Contactors

Instruction Manual Model BlockUpconverter

Series CT7N Bimetallic Overload Relays

Power Circuit of a UL508A Panel. Typical UL489 Application

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

SCALE & WEIGHT DISPLAYS

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Type: DILM12 10(24VDC) Article No.:

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Series CDP2 Definite Purpose Contactors

EA350. Generator Automatic Voltage Regulator Operation Manual

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Datasheet - SRB301LC 24VAC/DC

HS-509 VIBRATION TRIP MODULE

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Safe Switching with Safe Contactors

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Active UTP Transceiver Hub

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Instruction Manual Model # Block Upconverter

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Model Number Structure

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Single Point Flow Monitor SW118 SW119

CONTRACTORS SPECIFICATION

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Data Sheet Definite Purpose Contactors Ex9CK Series

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Transcription:

Type MG-6 Auxiliary Relay Class 1E Product Guide Device Number: 94X, Y, Z ZPA Rating 4.2g ABB

Application MG-6 relays have been specially designed and tested to establish their suitability for Class 1E application in accordance with the ABB program for Class 1 E Qualification Testing as detailed in bulletin STR-1. The MG-6 relays are used in protective relaying or control applications where electrically independent multiple contacts are required. They have six contact circuits, each capable of carrying 12 amperes continuously or 30 amperes for one minute. Relays are available with either a self reset armature (which resets when the operating coil is de-energized), or with a latch-type mechanism which holds the armature in a closed position until the latch is tripped electrically or by hand. Class 1E is the safety classification of the electrical equipment and systems in nuclear power generating stations that are essential to emergency shutdown of the reactor, containment isolation, cooling of the reactor, and heat removal from the containment and reactor, or otherwise are essential in preventing significant release of radioactive material to the environment. - 2 -

Construction The construction of MG-6 Class 1E relays is very similar in all aspects to their equivalent commercial relays. However, on Class 1E relays, a set of retaining blocks are attached to the base of both sides of the armature. The retaining blocks mechanically retain the armature to the relay s molded base, further stabilizing it, even under severe seismic conditions. Retaining block retains armature to molded base Armature Spring Tension Adjusting Screw Latch Adjustment Screw Moving Contacts (6) Stationary Contacts (6) Manual Reset Push Rod Reset Lever Operate Coil Spring Tension Adjusting Screw Locking Screw - 3 -

Mounting Options Enclosure A Semi-Flush Mount, Rear Connected, Molded Base Figure 1 Enclosure C Surface Mount, Front Connected, Molded Base (without cover) Figure 2 Enclosure F Surface Mount, Front Connected, Molded Base (with cover) Enclosure B Projection Mount, Rear Connected, Molded Base Figure 3 Figure 4 Enclosure D Semi-Flush Mount, Rear Connected, in Flexitest FT-22 case Allows for easy removal and testing of the relay. - 4 - Figure 5

Contacts and Operation Each of the six MG-6 relay contacts will carry 12 Amps continuously, and will close and carry 30 Amps for one minute. MG-6 relay contacts can be ordered as either Make (circuit closing) or Break (circuit opening) within the following guidelines: AC Operated Relays: AC operated relays can have any combination of Make or Break contacts DC Operated Relays: In DC operated relays, the number of Break contacts is limited to four, if normal contact pressure and travel are to be maintained. If more than four Break contacts are required, please consult with the factory. See Ordering Information (on page 7). Multiples of Rated VAC Applied to Operate Coil Dropout Time Cycles (ms) Time required to make contact Cycles (ms) 1 2.0 (32 ) 1.2 (20) 2 1.0 (17) 1.2 (20) = Operate coil will withstand 2X rated VAC for 2 minutes Multiples of Rated VDC Applied to Operate Coil Dropout Time Cycles (ms) Time required to make contact Cycles (ms) 1 1.5 (24) 5.0 (83) 2-2.5 (42) 3-2.0 (32) 4-1.5 (24) 5-1.0 (17) = Operate coil will withstand 5X rated VDC for 1 minute Control Circuit Voltage Interrupting Rating (in amps) DC AC (60 Hz) 1 Contact 2 Contacts in Series 12-30 30 24-15 30 32-10 20 48-8 16 125-3 6 250-1 2 115 30 30 230 20 30 460 15 30 575 10 20-5 -

Electrical Characteristics Pickup MG-6 relays will pickup at 80% of rating (both AC and DC) Dropout DC relays will not dropout above 30% of rating AC relays will not dropout above 50% rating Coil Ratings Operate Coil Continuous: 110% of rated voltage 1 minute DC: 500% of rated voltage 10 minutes DC: 200% of rated voltage 2 minutes AC: 200% of rated voltage Reset Coil 5 minute: 100% of rating Burden Data - Operate Coil Hertz Closed Gap Open Gap Watts Volt-Amperes Watts Volt-Amperes 25 6.8 23 19.6 53 50 9.8 31 17.4 78 60 12 37 17.6 92 DC 7.8 cold - 7.8 cold - DC 6.5 hot - 6.5 hot - Burden Data - Reset Coil Hertz Closed Gap Open Gap Watts Volt-Amperes Watts Volt-Amperes 25 48 51.6 52 54 50 46 58.2 57 63.8 60 84 104.5 97 112.8 DC 66 cold - - - = Rated voltage is 115V or multples thereof Additonal Reference Meets IEEE C37.98, C37.107, 323-1983 & 344-1987 Standards. UL Listed. Instructional Leaflet 41-753.11 Descriptive Bulletin 41-803 - 6 -

Ordering Information - MG-6 Class 1E Relay Rating Coil Code NONE 00 AC Coils 12 Volts 25 Hz 18 12 Volts 50 Hz 02 12 Volts 60 Hz 01 24 Volts 25 Hz 19 24 Volts 50 Hz 04 24 Volts 60 Hz 03 48 Volts 25 Hz 07 48 Volts 50 Hz 06 48 Volts 60 Hz 05 60 Volts 50 Hz 29 60 Volts 60 Hz 23 92 Volts 60 Hz 27 115 Volts 25 Hz 20 115 Volts 50 Hz 09 115 Volts 60 Hz 08 120 Volts 60 Hz 24 = Not available for Reset Coil. = Not available for Operate Coil. Rating - 7 - Coil Code 208 Volts 50 Hz 26 208 Volts 60 Hz 10 220 Volts 50 Hz 25 230 Volts 25 Hz 21 230 Volts 50 Hz 12 230 Volts 60 Hz 11 460 Volts 25 Hz 16 460 Volts 50 Hz 22 460 Volts 60 Hz 13 575 Volts 25 Hz 17 575 Volts 50 Hz 15 575 Volts 60 Hz 14 5 Amps 60 Hz 28 DC Coils 6 Volts dc 77 12 Volts dc 64 24 Volts dc 65 28 Volts dc 66 Rating Coil Code 32 Volts dc 67 36 Volts dc 68 38 Volts dc 69 40 Volts dc 78 48 Volts dc 70 62 Volts dc 71 79 Volts dc 72 125 Volts dc 73 200 Volts dc 74 220 Volts dc 75 250 Volts dc 76 500 Volts dc 80 0.1 Amp dc 79 1 Amp dc 63 2 Amps dc 62 3 Amps dc 61 4 Amps dc 60 5 Amps dc 59

ABB 41-803.1 Rev. A April 2008 Copyright 2008 ABB. All rights reserved. ABB Inc. 4300 Coral Ridge Dr. Coral Springs, FL 33065 Tel: +1 954.752.6700 Fax: +1 954.345.5329 www.abb.us/substationautomation