ART2000i Digital Dimming System. Installation guide. Stock number *8200-

Similar documents
INSTALLATION & USER GUIDE

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

INSTALLATION INSTRUCTIONS FOR

COMBINATION UNITS MARCH 2018

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Power Injector 1520 Series

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

10 PDUs 19 PDUs Zero-U PDUs

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LED-PAR200B USER MANUAL. COLORsplash 200B

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

SquareLED - Aura Bar & Matrix Beam Light 100

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

6000 Series Patch Panel Terminating Instructions

Medium Box for Cable Termination

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

TV Lift System Model CL-65 Installation Instructions

4320 SS-25 Self-Strip Terminating Block

Caution. Hanging the Screen:

Grounding-type plugs and sockets K Product information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Identification - electrical services

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

3M Locator Plate N

Figure 1: Device components

LED control gear Compact fixed output

3M Distribution Box (DDB)

Telemetry Receiver Installation Guide

LED IP65 Slimline Par RGBWA +UV 7x12W

LED-BANK4 USER MANUAL. COLORbank 4

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

24 Channel Demultiplexer

USER MANUAL Table of Contents

PEGASUS MASTER. 12-channel Digital Dimmer. User s manual. Sixth edition

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Wired Troubleshooting Manual

ENGLISH Antenna Distributor

Spectra Batten (Order code: LEDJ95)


HARTING Ethernet cabling cables and connectors, 4 wire

M1, M2GO and M2PC MIDI PCB Module Installation Guide SMPTE PCB Module Installation Guide

SQM40/41 Actuators for air and gas dampers

Stage Wash 7x 10W LED Moving Head (RGBW)

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

3 Cleaning. 4 Technical data

Recording to Tape (Analogue or Digital)...10

USER MANUAL Table of Contents

LED MODULES READYLINE DL

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Cyclo Series. user manual. MartinArchitectural

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LED Driver Compact dimming

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

FOSC 450 C6 and D6 Closures

INTRODUCTION PRODUCT CONCEPT AND DESCRIPTION

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Assembly instructions

Marine LCD Display MV-1504/1704/1904/2104

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

USER MANUAL Table of Contents

Vocia VI-6. Operation Manual

12U Quiet Office Mini Server Cabinet with Wood Finish, Casters and Fans

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Instruction Guide February 2017

Nixie Clock Type Frank 3

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

120cm (4x36 Watt) incl. Splitter Instruction Manual

Installation Manual SaVi Note Underwater LED Light

NewScope-7A Operating Manual

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

VGA Extender LR EXT-VGA-141LR. User s Manual

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Model /29S RF Splitter

DS1 Cross-Aisle Panel

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

A6 OPERATING INSTRUCTIONS

110LP MOON Series. Phono Preamplifier. Owner s Manual

3M Fiber Optic Wall Mount Enclosure 8430 Series

Transcription:

ART2000i Digital Dimming System Installation guide Stock number 8200-0159 *8200-

0159* Useful Avolites phone numbers:- Avolites England Sales and service* (+44) (0) 20 8965 8522 Service out of hours* (+44) (0) 831 17 8888 Fax (+44) (0) 20 8965 0290 Email Website name@avolites.com http://www.avolites.com Distribution of Avolites products in USA:- Avolites America Sales and service* (+1) 423 938 2057 Fax (+1) 423 938 2059 *Before contacting Avolites for service enquiry please ensure that you have the product serial number and the Software version (shown at switch on). The latest version of this manual (MS Word 2000 & PDF) and ART2000i Software can be downloaded from the Internet. The small print : No Liability for Consequential Damages Avolites has a policy of continuous product and documentation improvement. As such the detail within this manual may not match the operation of the ART2000i. In no event shall Avolites be liable for any direct, indirect, special, incidental, or consequential damages or loss whatsoever (including, without limitation, damages for loss of profits, business interruption, or other pecuniary loss) arising out of the use or inability to use the ART2000i even if Avolites Ltd. has been advised of the possibility of such damages. Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you. Reprint and revision history: First produced October 2002 by J.B.Toby, Avolites Ltd

C O N T E N T S 1. THE ART2000I INSTALLATION MANUAL 4 2. DIMMER SITE SPECIFICATIONS 4 3. UNPACKING THE DIMMER 5 4. INSTALLING 6 5. ENERGISING THE SYSTEM 10 6. APPENDICES 12

Page 4-1. The ART2000i installation manual INTRODUCTION 1. The ART2000i installation manual This manual is designed to explain the specifics about installing an ART2000i dimming system, this guide is not however a wiring regulation. Always consult the local wiring regulations before installing the system. This manual is in three parts: firstly the dimmer site specifications, then the installation guide and then an appendices section containing drawings and other useful information It is best to read the first two sections well before commencing to install dimmer system. 2. Dimmer site specifications 2.1 Dimmer site The ART2000i dimmer is intended to be wall mounted, This can be either on stage or away from the stage. It is not advisable to have the dimmer in a public are, or in a location where you cannot reach it without disrupting the show. Locating the dimmer near sound equipment is not advisable. Like any other dimmer the ART2000i dimmer generates heat, this heat needs to be vented for the system to work properly. The ART2000 system can work in a maximum ambient temperature of 40 degrees C. 2.2 Mains supply The ART20001 requires a switched and fused mains supply near the dimmer location with the following specifications: 3-phase 5-wire star mains system with TN-S wiring system (Phases L1,L2,L3 a neutral at ground potential and a protective earth) Supply cable sizes are dependant on the breakers selected and can be up to 35mm2 stranded copper wire (see: Terminating the mains supply cables ) The neutral cable should be sufficient to handle the neutral currents generated by a Phase Angle Controlled Dimmer (typically up to 130% of the Maximum Phase current). Therefore never fit reduced size neutral wires to supply a dimmer system Maximum Fuse ratings: Single frame with or without mains isolator option Double frame system without mains isolator option Double frame system with mains isolator option fitted 125A D type breaker or equivalent fuse (this may be a fuse-disconnector) Max Icu 10Ka 250A D type breaker or equivalent fuse (this may be a fuse-disconnector) Max Icu 10Ka 160A D type breaker or equivalent fuse (this may be a fuse-disconnector) Max Icu 10Ka

3. Unpacking the dimmer - Page 5 2.3 Load circuits The wiring of the load circuit should be in accordance with the local wiring regulations. The cable gauge selected should be capable of handling the current allowed trough by the channel breaker (16A C-type, 32A C-type ) and can be up to 4mm for a 16A channel in both stranded and solid copper wire and 10mm2 stranded copper wire for a 32A channel. 2.4 Ventilation The ART2000i uses two speed controlled internal fitted fan s to regulate the heat. Fresh Air is drawn in below the breakers and warm air is expelled at the top front of the unit. The ART2000i can operate in ambient temperatures up to 40 degrees. The Location for the dimmer needs to be such that the expelled heat is removed. This can be either trough ventilation or through cooling (airconditioning). If the dimmer is installed in a room without adequate ventilation the temperature will rise overtime (depending on the dimmer loading).and the dimmer may shut down if the internal temperature is to high (typically 80 C heatsink temperature). The ART2000i releases 25W per 16A channel run at full capacity, thus a whole rack can release a maximum of 600W ( 21 degrees C ambient ). The ventilation trough the dimmer displaces normally between 40 and 60 CFM per frame. This can go up to 420 CFM when running at maximum loading and ambient temperature. 3. Unpacking the dimmer 3.1 Checking for transport damage Check for damage before opening the box, and notify the shipper and the Avolites distributor or Avolites if it is direct from factory. Open the box by cutting the straps with a scissor, and remove the tape (do not use a sharp implement to prevent damage). Take the manual / installation kit out. 3.2 Contents check ART2000i frame (main or expansion) Copy off Operator s manual Copy off Installation manual Allen key for opening the front panels Fixing set (suitable for most locations)

Page 6-4. Installing 4. Installing 4.1 Preparing the parts The ART2000i is shipped with the cable entry box hooked in place, follow the procedure below to prepare for installation: Remove the mains connection terminals by unscrewing the two screws holding the DIN rail, then remove the connection block Unscrew the two M4 and M3 retainer screws and unhook the cable entry from the main frame (slide cable entry towards the breakers by 15mm and move horizontally backwards by 20mm) If the cable entry has a detachable plate for cable termination remove it now. 4.2 Mounting the cable entry box Affix the cable entry box so that it can hold at least 60Kg weight. To achieve this, use industrial type fixing (not cavity wall plugs and the like). The non patch cable entry requires 3 fixings and one for the frame. The patched version requires 4 fixings and one for the frame. In concrete/good brick wall use 6mm shield anchors (bold type) or chemical anchors (6mm) For cavity walls use the existing beams to affix or fit a load dividing cross bar to the excising vertical beams. (Ask the wall installer about the maximum load capabilities of the wall) For fixing in wooden beams use a 8mm coach screws Allow for enough space below the cable entry box to fit the dimmer frame The fixing in the bottom of the main frame will not carry any weight; it is purely there to hold the frame to the wall. The two M6 screws inside the bottom area of the dimmer frame can be used to align the frame to the cable entry See drawing below for clearances and location of the fixing holes:

4. Installing - Page 7 Avolites part number 17-82-0030 Avolites part number 17-82-0031 and 17-82-0040 L1 L2 L3 PE N Supply Cable inlet area circuit cable outlet area Ø14 Control cable area 140 465 usable apperature for cable entry all mains cable entries are PG13.5 Front of dimmer top view Front of dimmer top view 10 mm max. wall non flatness side view 1000 28 635 57 15 70 110 Supply Cable inlet area 15 250 300 circuit cable outlet area 250 Direct out mainframe front view Control cable area 70 85 720 min cieling clearance 200 mm 55 180 635 1150 70 Mains Patch mainframe front view 70 55 235 870 min cieling clearance 200 mm 180 180 180 180 210 27 normal installation height 800 minimum recommended height 600 normal installation height 800 minimum recommended height 600 4.3 Preparing the optional cable entry plate When the load cables are run through conduit or cable trays alternative holes need to be made in the cable entry. For this we have the cable plate entry. The detachable plate can be custom cut by the installer to fit the particular cable termination. Do this however in accordance with the local wiring regulations. The cable entry plate is not a suitable earth conductor for Steel Wire Armoured cable. Always connect the SWA cable gland with an earth-tag and separate earth wire to the earth bar inside the cable entry box. Fit the cable entry box prior to terminating any cables. 4.4 Terminating the 16A load circuits The load circuits can now be terminated. The Connector used can accept

Page 8-4. Installing up to 4mm2 cables both in solid core and stranded. If stranded is used no ferrules are needed (the connector uses a plate to grip the cable) Depending on the cable used it is usually best if the earth connections are made first. There are two connectors fitted to each frame, the left hand connector serves channels 1-12 and the right hand connector serves channels 13-24. Remove the connectors from the connector stands and terminate the load connections with sufficient spare cable according to the following table: Harting Pin Chan. Connection Harting pin Chan. Connection 1 Phase 1 or 13 13 Neutral 1 or 13 2 Phase 2 or 14 14 Neutral 2 or 14 3 Phase 3 or 15 15 Neutral 3 or 15 4 Phase 4 or 16 16 Neutral 4 or 16 5 Phase 5 or 17 17 Neutral 5 or 17 6 Phase 6 or 18 18 Neutral 6 or 18 7 Phase 7 or 19 19 Neutral 7 or 19 8 Phase 8 or 20 20 Neutral 8 or 20 9 Phase 9 or 21 21 Neutral 9 or 21 10 Phase 10 or 22 22 Neutral 10 or 22 11 Phase 11 or 23 23 Neutral 11 or 23 12 Phase 11 or 24 24 Neutral 11 or 24 When all connections are made fix the connector onto the connector stand so that pin 1 of the connector is on the lower left corner (pins can be seen). 4.5 Terminating the mains supply cables The mains supply terminals can accept stranded cable up to 35mm2 stranded copper wire. The only tool needed to fit this is a 4mm flat blade screwdriver. Insert the screwdriver and lever the handle to the centre of the terminal block, and push down. The screw driver can now be released and both hands are free to insert the cable (see picture) Ensure that the wires are connected properly and no strands are left outside the clamp area.

4. Installing - Page 9 The colour code used in the ART200i is: Red Yellow Blue Black Green/Yellow Phase L1 Phase L2 Phase L3 Neutral Protective earth 4.6 Hanging the dimmer module The Dimmer main frame can now be located onto the cable entry. Use two persons to do this by lifting the module vertical over the four hanging points of the cable entry box. When the mainframe is over the hook part lower it down while pushing it flat against the wall (front to back). Check that the hooks are fully engaged. (Do not feel with your fingers, as they may get trapped if the unit drops into the hooks) Fit the two M4 and M3 retaining screws, and fit the centre fixing screw into the wall. Frame hook Retaining screw 4.7 Final installation steps Fit the load connection connectors (24 pin Harting) from the power blocks to the cable entry connectors. Fix the mains input terminal block to the cable entry box (using the M4 screws supplied), and terminate the module feed wires into the mains input terminals.

Page 10-5. Energising the system 4.8 Terminating the DMX wiring Route the DMX cable between the two power-blocks from the top The two DMX inputs connect to two terminal strips on the left-hand side of the control card. The connections are: + Data - Data Gnd XLR pin 3 XLR pin 2 XLR pin 1 + Data - Data Gnd XLR pin 3 XLR pin 2 XLR pin 1 do not connect do not connect + Data XLR pin 3 - Data XLR pin 2 Gnd XLR pin 1 do not connect do not connect + Data XLR pin 3 - Data XLR pin 2 Gnd XLR pin 1 Line B Loop Line B Input Line A Loop Line A input control card STC 7060A If a termination resistor is needed (120R) for last in the line systems then fit this across the Data Loop out and +data Loop out terminals Do not use the Data input terminal as a loop out connection for Line A 5. Energising the system 5.1 Checking the supply wiring Check that the supply wiring is fixed and terminated properly, also check that the right connections have been made (see terminating the mains supply). Use a multi-meter to check for short-circuits between the phases and neutral and earth. Do not forget to switch all the breakers on during this test. 5.2 Checking the load wiring Check that all load wires are connected and have been properly terminated on the other end. Check that all the earth wires are connected properly. Use a multi-meter to check for short-circuits between the phases and neutral and earth

5. Energising the system - Page 11 5.3 Closing the box Fit all the front panels using the supplied Allen-key screws. The optional mains isolator prevents the main panel from being removed or fitted if the isolator lever and body is not in the OFF position. When closing the panels check that no cables are trapped under the panels 5.4 Energising Switch all the breakers off on the dimmer system, and switch the optional mains isolator OFF. Make sure no load is connected yet Energise the mains supply with the correct fuses fitted. Check that the 5 neon s indicate a correct mains supply The screen should now show the main menu with all channels indicating BT (Breaker Tripped) Line A 001 Dmx ok Status Running ok Line B 001 No Dmx Mode Test Off ------------BAY INPUT LEVEL-------------- Chan. 1 2 3 4 5 6 7 8 9 10 11 12 Bay 1 BT BT BT BT BT BT BT BT BT BT BT BT Bay 2 BT BT BT BT BT BT BT BT BT BT BT BT Switch the optional Bay RCB ON. Switch the channel breakers on, the corresponding channel should change the indication from BT to NL (No Load) The screen should now look like Line A 001 Dmx ok Status Running ok Line B 001 No Dmx Mode Test Off ------------BAY INPUT LEVEL-------------- Chan. 1 2 3 4 5 6 7 8 9 10 11 12 Bay 1 NL NL NL NL NL NL NL NL NL NL NL NL Bay 2 NL NL NL NL NL NL NL NL NL NL NL NL You can now connect loads and check that the NL disappears for each channel. To test the channel 5.4.1 Run testing channels Press the TEST ON button Select a channel to test using the encoder on the right, the selected channels is highlighted on the screen When the desired channel is selected press the encoder to change level of the channel.

Page 12-6. Appendices Pressing the encoder again allows you to select a different channel 5.5 Load Testing It is advisable to dry run the dimmer for at least 8 hours, with as much load as can be supplied by the mains system. Do this with persons present at the dimmer and mains supply so that if problems appear the system can be made safe. 6. Appendices 6.1 System Dimensions 6.2 Cable Sizes Mains input: Depending on protection fitted from 16 to 35mm2 stranded copper wire. Do not fit non-copper wire or solid wire. Never fit a reduced size Mains neutral input cable Load connections: Depending on the local regulations between 1.5 and 6mm2 stranded or solid copper wire for 16A channels and 4 to 10mm2 stranded copper wire for 32A channels. Do not fit non-copper cable

6. Appendices - Page 13 6.3 The components of an ART2000i Part Number Description Notes 17-82-0010 Basic Stand- Alone basic case, controller, lid, manuals installation kit Mainframe 17-82-0011 Basic Expansion Frame basic frame, lid, link cables, installation kit 17-82-0020 Full Wieland ST17 Patch 2 Panels dimmer outlet panel with 48 ST17 sockets patch outlet panel with 48 Wieland ST17 sockets terminating to 4 Harting 24 Ways connectors 17-82-0021 Half Wieland ST17 Patch 2 Panels 17-82-0022 Patch Blanking Plate 1 Panel 17-82-0030 Non Patch Pg13.5 Cable Entry 17-82-0031 Non Patch Plate Cable Entry 17-82-0040 Patch Plate Cable Entry 17-82-0050 125a Mains Switch 17-82-0051 160a Mains Switch 17-82-0052 2 Bay RCB Option 17-82-0060 12x 16A Dimmer Block 17-82-0070 6x 32A Dimmer Block dimmer outlet panel with 24 ST17 sockets patch outlet panel with 24 Wieland ST17 sockets terminating to 2 Harting 24 Ways connectors, empty patch sockets blanked blank plate to cover the dimmer patch out area cable entry with 24 half punched PG13.5 holes, 5 PG13.5 holes for mains inlet and 4 11mm holes for DMX input cable entry with a 1.5mm thick Zintex plate for custom holes(465x140mm) cable entry for patch versions only with a 1.5mm thick Zintex plate for custom holes(465x140mm) pad-lockable 125A mains switch pad-lockable 160A mains switch 12 x 16A C type breaker 100% duty cycle 240µS rise time 6x 32A C type breaker 100% duty cycle 240µS rise time 6.4 The ART2000i layout

Page 14-6. Appendices