OP5. Preprogrammed, configurable controller for simple applications

Similar documents
SAUTER flexotron RDT405 Manual

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

T775U Series 2000 Electronic Stand-Alone Controller

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

02/11/2015

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Level Measurement silometer FMC 420, FMC 423

T775U Series 2000 Electronic Stand-Alone Controller

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Professional-Practice

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

263 Series LED Bargraph Indicator and Controllers

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

TFRN Industrial RTD temperature sensor. CombiTemp TM

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

DATA SHEET Panorama Rudder Indicator, TRI-2

LED Driver Linear / area fixed output

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Capacitance Limit Detection nivotester FTC 420/421/422

Digital differential Pressure switch Model DPS Instruction manual

Panel-mounting thermostats, type series EM

TFRH Hygienic RTD temperature sensor. CombiTemp TM

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

EUROPEAN COMMUNITY DIRECTIVES

Arc Detecting and Protection System

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Photoelectrics Through-beam Type PA18C.T..., DC

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Process transmitter RMA422

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LED Driver Compact fixed output

Electrical connection

Enclosing the STB Island

Electronic Pulse Counter Combination device

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Catalogue Ignitors and power switches for HID

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Gamma instabus. Technical product information

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Capacitance Level Measurement Electronic insert FEC 12

LED Driver Compact fixed output

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Amplifier for fiber optics. Dimensioned drawing

Arc-fault Protection System

Material: Weight: IP Rating: Cable: Connector:

multi-function meters

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DIN Power Module - Phase Adaptive

CAMTO LTD. Arc detecting system DC/AC

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LED Driver Compact dimming

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Rack mounted telephone- and leased line modem for industrial applications

Mechanical flow switch for On/Off control

Label Applicator HERMA 400

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Datasheet - SRB301LC 24VAC/DC

Modular Lube Lubrication Systems System Controls

Luminaire installation box Surface-mounted box Ceiling installation box

Magnecraft Power Relays

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LED control gear Compact fixed output

LED MODULES READYLINE DL

Datasheet - SRB-E-201ST

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

SH2RE16A4. Output relay module. Benefits. Description

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

OT 100/ /700 P5

DLP200M 2 Relay Module for Heating and Cooling Plants

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Fibre Optic Modem ODW-622

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Heating thermostat Series AMHs B Operating Instructions 11.06/

Transcription:

sect. pos. revision 3 020 08 2007 OP5 Preprogrammed, configurable controller for simple applications Optigo 5 is a new preprogrammed, configurable controller intended for DIN-mounting that can be set to handle everything from temperature control or humidity control to CO 2 control or pressure control. Language independent Easy to configure Numeric/graphic. background illumination Pre-loaded with several application modes Simple handling with puch-/ turn knob Change-over Optigo OP5 is a new pre-programmed, configurable controller for HVAC applications. It has been designed with the main intention of replacing a number of Regin s Aqualine controllers. Optigo Optigo Regin s newest control series intended to control temperature, CO 2, pressure, humidity and tap hot water in HVAC applications. A simple stand-alone controller for smaller applications. The controller is extremely easy to install, set-up and control and are mainly intended for smaller applications. Optigo has a knob with an encoder which makes the menu system very easy to use. You can read and set values shown in the back-lit display. A value is approved by pressing the knob. Models The Optigo series comprises two different models, OP5 and OP10. OP5 has 5 in-/outputs and OP10 has 10 in-/outputs. OP5 is intended for 24 AC supply voltage. OP10 are available in versions for both 24 V AC and 230 V AC Applications OP5 and OP5 Optigo OP5 is preprogrammed with a choice of five different control modes: Temperature control CO 2 Humidity control Pressure control Outdoor temperature compensated pressure control In- and Outputs Optigo OP5 has: 1 analogue input, PT1000 1 universal input, PT1000 or digital 1 digital input 2 analogue outputs, 0 10 V DC Easy to install Optigo is suitable for DIN-rail or cabinet mounting. Since the terminals are detachable all connections can be made before Optigo is installed. Optigo has been developed according to our Ready-Steady- Go concept, which simplifies every step from installation to management.

Display handling On the display the following indications/information can be displayed. All setting and configuration is done using the display and encoder. The menu information on the display is organised in a tree fashion. Using the encoder you can move between menus, set values and actual valve. In any of the configuration menus, a click on the encoder will activate change mode. You can then turn the encoder button to move between choices or set values. A second click of the button will accept the choice. The menu system is divided into two levels: Base level - view mode 10-second level - configuration area Turn: move up/down in the menus Click: enter new menu or accept new setting Press for 10 seconds: enter the configuration menues Base Display This is an example of the Base Display, the display that is normally shown when there is no operator activity. The upper line shows which control mode has been configured, in this case control mode 1, Temperature control. The bottom line shows the actual value. There are bar-graphs showing the current output levels. In control mode there are symbols showing how the outputs have been configured (Heating, Cooling, Damper or Change-over). When the base display is shown, by turning the knob counter clockwise until the text I/O is displayed and then clicking on it, you can gain access to a menu where you can look at the values and states of all inputs and outputs. To exit this menu again, click on the knob and then turn the knob clockwise and you will be returned to the Base display. Configuration Display information Outdoor compensation configured Temperature control Menu holds changable values Configuration level Change over Menu number AO1 Graphic output signal Control mode 1 only Bargraph AO1 output level Bargraph AO2 output level Active 0...10V input signal AO2 Graphic output signal Control mode 1 only All the configuration menus lie in the 10-seconds level. This level is accessed from the Base Display by clicking and holding the encoder knob for 10 seconds. There are numerous configuration menus covering all available options and combinations. In some cases, making a certain choice in one menu will mean that you will only see certain other menus. For example, the menu for setting the damper minimum limit is only shown if you have configured AO2 to be a damper control output. Humidity control The humidity at the sensor is kept at the setpoint value

Application examples Optigo OP5 can be configured to any one of the following control modes. Temperature control The temperature at the sensor is kept at the setpoint value by controlling the output signals on AO1 and AO2. A single PI control loop is used. CO 2 -control The CO 2 -value at the sensor is kept at the setpoint value by controlling the output signal on AO1. A single PI control loop is used. The analogue outputs can be configured to the following combinations: AO1 AO2 1. Heating / - 2. Cooling / - 3. Heating / Cooling 4. Heating / Heating 5. Cooling / Cooling 6. Heating / Damper 7. Cooling / Damper 8. Change-over* / - * (Seasonal change-over between heating and cooling) The output signal will increase when the CO2-value rises above the setpoint value. The CO 2 -sensor must have a 0...10 V DC output. Use a Regin sensor according the information below: CO2RT, CO2RT-D Room sensors CO2DT Duct sensor The transmitter range cannot exceed 5000 ppm at 10 V DC output. Humidity control The humidity at the sensor is kept at the setpoint value by controlling the output signals on AO1 and AO2. AO1 is used for humidification, AO2 for dehumidification. A single PI control loop is used. Humidification and dehumidification can be used simultaneously. A neutral zone can be set between humidification and dehumidification. The humidity transmitter must have an output signal of 0...10 V DC. Use a Regin sensor according the information below: HRT, HRT250 or HRT350 Room humidity transmitters HDT2200 or HDT3200 Duct transmitters

Pressure control The pressure at the sensor is kept at the setpoint value by controlling the output signal on AO1. A single PI control loop is used. Pressure control with outdoor compensation The pressure at the sensor is kept at the setpoint value by controlling the output signal on AO1. The setpoint is automatically adjusted according to the outdoor temperature. A single PI control loop is used. The output signal will increase when the pressure signal falls below the setpoint value. The pressure transmitter must have an output signal of 0...10 V DC. Use a Regin sensor according the information below: DMD DTL-series DTK-series TTK-series Pressure ranges up to 500 kpa kan be set. The output signal will increase when the pressure signal falls below the setpoint value. The setpoint value follows a settable pressure-to-outdoor temperature relation. The pressure transmitter must have an output signal of 0...10 V DC. Use a Regin sensor according the information below: DMD DTL-series DTK-series TTK-series Pressure ranges up to 500 kpa kan be set.

Technical data Supply voltage Ambient temperature Storage temperature Ambient humidity Display Protection class Material casing Terminal blocks 24 V AC; ±15%, 50...60 Hz 0...50 C -20...70 C Max 90% RH Numeric / graphic. Background illumination IP20 Polycarbonate, PC Disconnectable, so-called lift type for cable cross-section 2.5 mm2 Weight 215 g. Colour Cover: Silver Bottom part: Dark gray This product conforms with the requirements of European EMC standards CENELEC EN 61000-6-1 and EN 61000-6-3, conforms with the requirements of European LVD standard IEC 60 730-1 and carries the CE mark Inputs Analogue input AI1 Universal Input AI or DI Digital Input DI Outputs Analogue outputs AO One PT1000-sensor, range -30 +54 C, accuracy +/- 0.2 C One analogue- or digital input 0 10 V DC, accuracy +/- 0.15 % of full output Closing potential-free contact One Closing potential-free contact Two 0 10 V DC; 8 bit D/A short-circuit protected Settings Setpoints Temperature setpoints Temperature -20..40 C Hystereses 0...10 C P-band 0 99 C I-time 0 990 sec. Min.-limit damper 0 99 % Other Settings Setpoints CO 2 0...6534 ppm (The settable range corresponds to the sensor measuring range) Humidity (RH) 0...100% (The settable range corresponds to the sensor measuring range) Pressure (Pa) 0...500 kpa (The settable range corresponds to the sensor measuring range) Hystereses 5% of max. (only humidity) P-band 0...100% corresponding to the sensor measuring range (exept pressure 0...300%) I-time 0 990 sec. Outdoor compensation, start -30 50 C Pressure at -20 C outdoor temp. 50 Pa...500kPa 5

Wiring OP5 Terminal Designation Operation 10 G 24 V AC 11 G0 Optigo 10 12 only Terminal Designation Operation 20 A GND Reference for AO1 and AO2 21 AO1 0...10 V DC output 22 AO2 0...10 V DC output 41 DI+ Reference for DI1 42 DI1 Digital input 43 UI+ Reference for UI1 Digital mode 44 UI1 Universal 0...10 V DC or digital input 50 A GND Ref. for AI1, AI2 and UI1 anologue 51 AI1 PT1000 temp.erature sensor input Dimensions 120 122 64 (mm) Product documentation Document Optigo Manual Type Manual for the Optigo OP5 All product information is available on www.regin.se Head Office Sweden Phone: +46 31 720 02 00 Web: www.regin.se Mail: info@regin.se Sales Offices France: +33 14 171 46 46 Hong Kong: +852 24 07 02 81 Singapore: +65 67 47 82 33