PRODUCT SHEET

Similar documents
PRODUCT SHEET

Multi-Parameter Monitoring Data Acquisition System for SpO 2 Signals

Supplementary Information

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

Lesson 14 BIOFEEDBACK Relaxation and Arousal

PRODUCT SHEET

PRODUCT SHEET TRANSDUCER MODULE GSR100C

JD725A Cable and Antenna Analyzer - Dual Port

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Advanced Test Equipment Rentals ATEC (2832)

Overview. Signal Averaged ECG

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

Datascope Spectrum OR With Gas Module 3 Monitor

The DataView PowerPad III Control Panel

WHALETEQ PPG Heart Rate Simulator Test System (HRS200) User Manual

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

imso-104 Manual Revised August 5, 2011

SCALE & WEIGHT DISPLAYS

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

NewScope-7A Operating Manual

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

DVO700 P FIBRE OPTIC TRANSMITTER

AC : A SMALL, HIGH-FIDELITY REFLECTANCE PULSE OXIMETER

PRODUCT DATA SHEET FEATURES

OP750. Multichannel Source Instruction Manual

NEXT/RADIUS Shelf Mount CCU

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

E X P E R I M E N T 1

Honeywell HomMed Wireless Scale Quick Reference Guide

Transmitter Interface Program

OPTICAL POWER METER WITH SMART DETECTOR HEAD

BioGraph Infiniti Physiology Suite

EAN-Performance and Latency

Extracting vital signs with smartphone. camera

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

OPTICAL DISTRIBUTION STATION -

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

MRI SAFETY CONNECTION GUIDE

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

ZX-44XL Liquid Fuel Analyzer. User s Manual Version 1.2

VGA to HDMI Scaler x1200

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

Metal Electrode Meter

FiberLink 7142 Series

013-RD

Activity P27: Speed of Sound in Air (Sound Sensor)

OWL micro+ WIRELESS ELECTRICITY MONITOR

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Development of an Oxygen Saturation Monitoring System by Embedded Electronics

imso-104 Manual Revised July 19, 2012

MAP Optical Power Meter Module (mopm-b1)

Digital Storage Oscilloscopes 2550 Series

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Analog HD video over fiber converters for smart HD CCTV

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Working with CSWin32 Software

ATSC HDTV DIGITAL TERRESTRIAL SET TOP TUNER

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

PREPAX DELUXE INTERCOM SYSTEMS

Session 1 Introduction to Data Acquisition and Real-Time Control

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Getting Started with the LabVIEW Sound and Vibration Toolkit

STB Front Panel User s Guide

Lesson 10 Manual Revision BIOPAC Systems, Inc.

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

FRQM-2 Frequency Counter & RF Multimeter

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Prisma Optical Networks Ancillary Modules

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

All headers in the table of contents are clickable. Additional links are indicated by a double underline.

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

56-23 Synopsis of Vital Signs Monitors (Project 98-35) (1/99)

Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide

HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K

Alice 5 Diagnostic Sleep System

LAUREL ELECTRONICS, INC.

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

PLASMA MONITOR (PT20 UVVis) USER GUIDE

This module senses temperature and humidity. Output: Temperature and humidity display on serial monitor.

M R X

BASIC TUTORIAL. Jocelyn Mariah Kremer, Mike Mullins Documentation BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc.

Quick Setup Guide for IntelliAg Model NTA

1215L 12 LCD Desktop Touchmonitor

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

WQ Series Water Quality Bench top Meters

USB Smart Power Sensor

Transcription:

PULSE OXIMETRY OXY100E Module (18-321 BPM) OXY200 Module (for veterinary use only, 18-450 BPM) TSD124 Series SPO2 Transducers for OXY100E or OXYSSH-SYS TSD270 Series SPO2 Transducers for OXY200 These modules measure beat-by-beat, blood oxygen saturation (SpO 2 ) level in a noninvasive fashion. The OXY100E outputs four signals simultaneously: A: SpO 2 value (Ch 1, 2, 3, or 4) B: Pulse Plethysmogram (Ch 5, 6, 7, or 8) C: Heart pulse rate (Ch 9, 10, 11, or 12) D: Module Status (Ch 13, 14, 15, or 16) These signals are directed to switchable blocks of different MP input channels. Up to four OXY modules can be used with a single MP System. The modules have built-in calibration for a simplified setup procedure. Each OXY module requires one of the TSD124 series SpO 2 transducers. The modules operate in accordance to principles outlined by the Lambert-Beer law; this is an empirical relationship that relates the absorption of light to the properties of the material through which the light is traveling. The OXY modules are noninvasive instruments that measure blood-oxygen percentage levels. The module probe incorporates light-emitting diodes (LEDs) which face photodiodes through a translucent part of the subject's body, usually a fingertip or an earlobe. One LED is red, with wavelength of 660 nm, and the other is infrared (approximately 910 nm). Light absorption at these wavelengths is different between oxyhemoglobin and its deoxygenated form. The oxyhemoglobin/deoxyhemoglobin ratio can be calculated via the ratio of the absorption of the red and infrared light. In particular, the OXY modules output (as a proportional voltage) the percentage of arterial hemoglobin in the oxyhemoglobin state. BIOPAC Hardware PULSE OXIMETRY Page 1-5 Updated: 1.18.2017

TSD124 Series SpO2 Transducers For OXY100E TSD124 Series TSD124A Finger TSD124C Flex Wrap The TSD124 series human oximetry transducers are reliable and simple to use on a wide range of subjects for both short-term and continuous noninvasive monitoring. The transducers incorporate Nonin s PureLight sensors and are backed by a six-month warranty. Use with the OXY100E oximetry amplifier or OXYSSH-SYS pulse oximetry system. Available Types: TSD124A Finger Clip Transducer Subject Range: > 30 kg (66 lbs) Preferred application: Index, middle or ring fingers TSD124B Ear Clip SpO2 Transducer Subject Range: > 40 kg (88 lbs) TSD124C Flex Wrap SpO2 Transducer (Ships with 25 RX124C adhesive wrap guides) RX124C Disposable FlexiWrap adhesive guides for use with the reusable TSD124C Flex Sensor. Sized for adults (> 20 Kg or 44 lbs) Apply to index, middle or ring finger. Qty 25 per pack Also available: OXY100E-200 EXT Pulse Oximeter extension cable 3m TSD270 Series SpO2 Transducers For OXY200 The TSD270 series veterinary oximetry transducers are reliable and simple to use on a wide range of animals for both short-term and continuous noninvasive monitoring. The transducers incorporate Nonin s PureLight sensors and are backed by a six-month warranty. Use with the OXY200 Veterinary oximetry amplifier. BIOPAC Hardware PULSE OXIMETRY Page 2-5 Updated: 1.18.2017

TSD270A Transflectance Transducer The Transflectance Sensor, the smallest probe, is ideally suited for continuous monitoring from the paw, tail, or other vascularized part of the animal. It can be conveniently placed on the underside, base of the tail or other well-perfused surfaces. It is an excellent option during dental procedures. TSD270B Small Animal Wrap Transducer The flexible wrap sensor can be placed on a small, well-perfused appendage. This sensor is easily secured making it ideal for continuous monitoring during long surgical or other procedures. It is most often used on rodents or other very small animals. TSD270A TSD270B Pulse Oximeter Calibration OXY100E/OXY200 Modules will operate with default values unless an exact calibration is performed using the recessed Cal button on the OXY module and AcqKnowledge scaling. To access the Scaling analog channel dialog, click MP menu > Set Up Channels and then click View by Channels, click Setup and click Yes when prompted. On the OXY module, use a paperclip or pen tip to press and hold the recessed Cal button. Press and hold the Cal button for ~1.5 seconds to switch between modes, as indicated by the Status LED states. BIOPAC Hardware PULSE OXIMETRY Page 3-5 Updated: 1.18.2017

Normal Status LEDS = GREEN OFF and YELLOW OFF (YELLOW may occasionally flicker due to background processing) Calibration Low Status LEDs = CONSTANT GREEN ON and YELLOW OFF Calibration High Status LEDs = GREEN OFF and CONSTANT YELLOW ON Release the Cal button as soon as the mode switches continuously holding the button in the depressed state will not lead to another mode change. Modes cycle from normal to low, then to high, then back to normal. Press and hold the Cal button for ~1.5 seconds to switch to Calibration Low mode and then click the Cal2 button in the software for any of the OXY module analog channels that are enabled. Press and hold the Cal button again for ~1.5 seconds to switch to Calibration High mode and then click the Cal1 button in the software for any of the OXY module analog channels that are enabled. Press and hold the Cal button again for ~1.5 seconds to return to Normal mode. It s best to calibrate the OXY module once, then Save As > Graph Template to save the respective scale values. OXY100E/200 Series Specifications Outputs: SpO 2, Pulse Rate, Pulse Waveform & Module Status Pulse Rate Range: OXY100E: 18-321 BPM, OXY200: 18-450 BPM Pulse Rate Output Options*: Standard (4 beat average, slew limited) Extended (8 beat average, slew limited) Beat to Beat (un-averaged, non-slew limited, beat-to-beat value) Fast (non-slew limited, 4 beat average) Standard (4 beat average, slew limited) Extended (8 beat average, slew limited) SpO 2 Range: 0-100% SpO 2 Accuracy: 70-100% ±2% Measurement Wavelengths Red: 660 nanometers @ 0.8 mw maximum average and Output Power: Infrared: 910 nanometers @ 12 mw maximum average Operating Temperature Range: 0-50 degrees C Operating Humidity Range: 10-90% (non-condensing) Compatible Sensors: BIOPAC TSD124 series Principle of Operation: Lambert-Beer law employing dual wavelengths *for un-averaged, Beat-to-Beat Pulse Rate: use AcqKnowledge Rate detector on Pulse Waveform Output. All other settings are established by dip switches shown on page 5. OXY100E and OXY200 Status Output Values Event Weight Out of Track/No 0/16*10 V (~ 0 V) sensor Artifact 1/16*10 V (~ 0.625 V) Sensor Alarm 2 /16*10 V (~ 1.25 V) Green Perfusion 16/16*10 V (~10 V) Yellow Perfusion 14 /16*10 V (~8.75 V) Red Perfusion 13 /16*10 V (~8.125 V) BIOPAC Hardware PULSE OXIMETRY Page 4-5 Updated: 1.18.2017

OXY100E and OXY200 Switches The dip switch bank on the back panel can be used to control output for the SpO 2 and HR channels. Use Calibration for exact output levels. Output is ~10 V if the sensor is out of track. Dip Switch Channel Output details 1 2 3 SpO 2 Range is 0 V (0%) to ~7.9 V (100%) OFF OFF OFF 0-127 % 4-beat average values updated every pulse beat in standard 1 mode Factory setting OFF ON ON 0-127 % 4-beat average values updated every pulse beat in standard 1 mode ON ON ON 0-127 % 4-beat average values updated every pulse beat in standard 1 mode ON OFF OFF 0-127 % 4-beat average displayed values updated every 1.5 seconds in display 2 mode OFF OFF ON 0-127 % 8-beat average values updated every pulse beat in standard 1 mode ON OFF ON 0-127 % 8-beat average displayed values updated every 1.5 seconds in display 2 mode OFF ON OFF 0-127 % Non-slew limited saturation with 4-beat averaging updated every pulse beat in standard 1 mode ON ON OFF 0-127 % Non-slew limited, not averaged, beat to beat value updated every pulse beat in standard 1 mode 4 5 HR Range is 0 V (0 BPM) to ~6.27 V (321 BPM) for human OXY100E 0 V (0 BPM) to ~8.86 V (450 BPM) for veterinary OXY200 OFF OFF 0-max 3 BPM 4-beat average values updated every pulse beat in standard 1 mode Factory setting ON OFF 0-max BPM 4- beat average displayed values updated every 1.5 seconds in display 2 mode OFF ON 0-max BPM 8-beat average values updated every pulse beat in standard 1 mode ON ON 0-max BPM 8-beat average displayed values updated every 1.5 seconds in display 2 mode 1 Standard SpO 2 and Pulse rate updated on every pulse beat. SpO 2 and Heart Rate values are set to missing data values and out of track indicated. 2 Display SpO 2 and Pulse rate updated every 1.5 seconds. Last in track values transmitted for ten seconds and out of track indicated; after ten seconds, values are set to missing data values. 3 511 BPM Output of 511 BPM (+10 V) indicates that sensor is not connected or signal is bad (out of track or sensor is not secured on the finger). The module never outputs BPM between range max (321 or 450) and 511. BIOPAC Hardware PULSE OXIMETRY Page 5-5 Updated: 1.18.2017