UTH-170 Installation and Manual

Similar documents
EPU-400 -THERMOSTAT MANUAL- ENERPIA CO., LTD

UTH-70T INSTALLATION AND MANUAL

UTH-JP MANUAL 4 HOUR S/W: S/W FOR SETTING THE WATCH (HOUR), IN CASE OF RESERVATION, SET THE HOUR UNIT OF TIME

Figure 1: Device components

Modular Lube Lubrication Systems System Controls

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Dimming actuators GDA-4K KNX GDA-8K KNX

Spectra Batten (Order code: LEDJ95)

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

1.10mm Height 1210 Package. Bi-Color (Multi-Color) Chip LED. Technical Data Sheet. Part No: S155VBC-V12B-B41B

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

SM-10 SAT Level Meter User s Manual

(RGBW)

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Features: Descriptions: Applications:

AMBIENT LIGHT SENSOR IC

3mm Round Blue LED T-1 Technical Data Sheet

Luckylight Package Pure Green Chip LED. Technical Data Sheet. Part No.: S150PGC-G5-1B

Luckylight Package Warm White Chip LED. Technical Data Sheet. Part No.: S150W-W6-1E

IP Roombox. Hotel Room Management

Luckylight. 1.10mm Height 0805 Package. Warm White Chip LED. Technical Data Sheet. Part No.: S170W-W6-1E

Quick Start Operating Instructions

Technical Data Sheet White SMD Surface Mount Device

02/11/2015

3mm Round White LED T-1. Technical Data Sheet. Part No: LL-304WC2E-W2-3TC

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Multifunction Digital Timer

LED Driver Compact fixed output

K-BUS Dimmer Module User manual-ver. 1

Datasheet - SRB-E-201ST

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

Gamma instabus. Technical product information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Operating instructions Electronic preset counter Type series 717

Bimetal Temperature Switch

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

LED Driver Compact fixed output

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

Installation Instructions

"shell" digital storage oscilloscope (Beta)

Panel-mounting thermostats, type series EM

DIGISAT MULTI USER MANUAL

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Luminaire installation box Surface-mounted box Ceiling installation box

Software Manual Control Panel for Professional Single Booster Units Models: MM3 BW3

Ordering details. Approval. Classification

Sample BD Tech Concepts LLC

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Technical Data Sheet 0805 Package White Chip LED

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

ATEA LED ACDC User Manual (0) ATEA LED

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

AUTOMATIC TAPING MACHINE INSTRUCTION MANUAL TAIYO SEIKI CO., LTD.

Series CT7N Bimetallic Overload Relays

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Solid-State Digital Timer

XT-17M-B relay - Delay-off, 1 C/O, 16 A

n Transient feature simulates voltage variations, brownouts and transient voltage conditions

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

INSTALLATION AND OPERATION M

Video Accessory IC Series Sync Separation ICs with Built-in AFC BA7046F, BA7071F Rev.A 1/9

Laboratory 8. Digital Circuits - Counter and LED Display

LED Driver Linear / area fixed output

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

TRF STEP-DOWN TRANSFORMER USER MANUAL

T Series LED Remote Controller

Multi-functional safety relay modules PROTECT SRB-E

Part No: 0805-FLWC-DHB

Manual for WMR-252 built-in receiver with universal dimmer

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

Hardware & software Specifications

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

Digital output modules

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

IEFIS G3 Inputs, outputs and Alarms

TriLIN Program Utility TPU_ TriLIN Programming Manual

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

The Importance of Projector Maintenance.

Tebis application software

multi-function meters

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Radio Thermostat Clock

Technical Data Sheet 0603 Package Chip LED (0.4mm Height)

Sentinel I24 Digital Input and Output Configuration

DCP100 Digital Control Programmer Specifications

Transcription:

UTH-170 Installation and Manual

Wiring Method #1 Method of Wiring Adhesion

Wiring Method #2 Method of Wiring Adhesion

Change of Function and Motions LAMP DISPLAY SET Lamp : This flickers at the time of changing the setting value or changing the set temp with temp set button. (Green Lamp) In case there is no motion in keys after the change of temp is over or the set is completed, the present temp is displayed again after 3sec and SET Lamp flickers. RUN Lamp : At the time of output is progressing in the side of load, Lamp flickers. (Red Lamp) This flickers when the output is progressing after SET is over, and this flickers directly after detecting error. TIMER Lamp : This flickers at the time of changing time with timer set key or in the course of time set motion. (Green Lamp) This flickers when timer motion is over or SET is terminated. BASIC MOTIONS TEMP SET : The temp on the display window displays the present temp in all times. In case of pushing the SET button or changing the SET, the window displaying temp displays the set temp. If there is no change in set temp, the present temp is displayed again and moving after 3 sec. POWER MOTION: This is used for ON/OFF of controller s power. In the state of OFF, all displays are OFF and key does not work. TIMER SET: This is the function for OFF of controller s power automatically. In SET, time flickers at the time of pushing Timer Button for the 1 st time. By pushing the button once again while it flickers, it is possible to set up to 12 hrs. at max; if set 0 hour, Timer Lamp is OFF and its motion is terminated. Timer motion is terminated automatically by OFF and ON of power with the power button; in case that main power is broken caused by power failure and others; The existing set time is maintained and running directly after reopening the power. METHOD OF SET At the time of changing in detailed set temp range, it should be set. By pushing Temp Set Up and Down buttons for 3 sec simultaneously, tn is displayed on the temp display window. At this time, by pushing Up or Down key, the menu, such as In St En, is displayed. When an item on the menu what is wished is displayed, by pushing Temp Set Up and Down buttons simultaneously, move to the next step. After completing all SETs as above method, AU message flickers for three times and the changed value is saved. It is recommended that the detailed set should not be done by a general consumer. In case of making a mistake in set, error massage is displayed and there may be malfunction.

Change of Function and Motions En : This is the method by the most common sensor. In case of sensor mode, this works by comparing the set temp of controller and the sensed temp in the point where the sensor is installed. (See Table #1) (ex : Set temp>present temp: Output ON, Set temp<present temp: Output OFF) Table # 1 (Sensor Mode) Role Display Basic Set Scope of Set Motion description Class. of Function tn S SEN, TIMER, RESET SEN(Sensor Motion Type), TIMER(Time Motion Type), RESET(Initialization) Air-Conditioning -C HH HH, CC HH(Heating Mode) CC(Cooling Mode) Min. Temp Set -L 0-20 ~ under max temp Set the lowest temp within the scope of temp Max. Temp Set -H 60 Over min temp ~80 Set the highest temp within the scope of temp Temp Deviation Set IF 2 0 ~5 ON/OFF motion in the deviation between set and present temp Output Delay Time Ly 20sec 01sec ~ 60sec At the time of ON of output, move as late as the delay time Overheating Temp Set Ht 60 Over max temp ~ 80 Error occurrence in case the overheating sensor temp is exceeding the set temp. (OPTION) Compensating Temp Set ES 00-10 ~ 10 Scope for compensating the deviation of real temp. TIMER FUNCTION * In case of using Timer Function, must disjoin the sensor. (See Table #2) By pushing, keys for 3 sec simultaneously, tn is displayed. By pushing once, EN is displayed. EN using the method of SENSOR is same to the present method. By pushing key once again, In is displayed and at this time, by pushing, keys simultaneously, the present cycle value is displayed. By using, keys, set the cycle and by pushing, keys simultaneously, AU flickers; the cycle value is saved; and the present set strength is displayed. Set method by serviceman = Push, keys simultaneously tn is displayed on the display window select tin - push, keys simultaneously Cycle value is displayed (Cycle) Select Cycle (Basic 3 min.) Set Cycle value - Push, keys simultaneously - AU flickers - Save is completed * It is recommended not to be set by a consumer. How to use by a consumer= select the strength by using, keys (basic 1 st step)

FUNCTION (TIMER MODE) In type = As timer mode, work by setting the cycle and step. (See Table #2) (if wishing to use the timer mode, must disjoin the sensor.) If sensor is down in using the sensor mode, it switches to timer mode automatically. Timer function * If wishing to use timer function, must disjoin the temp sensor. By pushing and key for 3 sec simultaneously, the tn is displayed initially. Push key for en display. EN works by Sensor as the same to the present method. By pushing key one more, In is displayed; at this time by pushing and key simultaneously, the present cycle value is displayed. With and keys, set the cycle. By pushing and key simultaneously once again, AU flickers and the cycle value is saved and the present set strength is displayed. Set method by serviceman = push and key simultaneously tn displays on the window select tin- push and key simultaneously display the cycle value (cycle) select cycle (basic unit: 3min.) - Set cycle value - push and key simultaneously - AU flickers Save is completed. * It is recommended not to be set by a consumer. How to use by a consumer= select the strength by using, keys (basic 1 st step) Table #2 Step Output (0N) Output (OFF) Remarks 1 15sec * S 45sec * S 2 20sec * S 40sec * S 3 25sec * S 35sec * S 4 30sec * S 30sec * S 5 35sec * S 25sec * S 6 40sec * S 20sec * S 7 45sec * S 15sec * S 8 50sec * S 10sec * S 9 55sec * S 5sec * S 10 60sec * S 0sec * S S selected cycle value If 1min S=1 If 3min S=3 If 5min S=5 * * (If 20min s = 20, value multiplying by 20) (If 60min s = 60, value multiplying by 60) It is the length of ON and OFF.

SPEC. Classi. Item SPECIFCATIONS Power unit Rated input voltage Output voltage Driving method Max output 85V AC ~ 265V AC (Universal voltage) 85V AC ~ 265V AC (Universal voltage) Electronic Type 2kw Load No. of circuit 1 circuit Max capacity 18A (Resistance load) Precision Temp precision ± 1 ; change condition of 1 per 30 sec (Delay Option 20sec) Power input display LCD flickers, Temp display Motion Output display Bar motion on LCD display window: ON display Range of temp Possible to select within the range between -20 ~ 80 Output delay(option) Kind 01sec ~ 60sec NTC : Negative Temperature Coefficient Epoxy molding Sensor Precision % 1 % 25 rated resistance 5000 ohm, Beta Constant = 4000 k Quantity SENSOR 1 : for sensing temp, SENSOR 2 : for checking overheat (Option) Function (Capacity) Safety Device Snapping/ Short of Sensor Line Overheating Prevention Sensor(OPTION) Snapping of temp sensing sensor: Timer auto switch motion, In case of short: ES (Error Short) displays and Buzzer for output break sounds. The temp sensed in the overheating sensor is higher than that of set overheating temp: oht (Over Heat) displays and Buzzer for output break sounds. resistance for fuse 10 ohm (protecting the inside circuit of controller) Outer case Anti-flammable Others Weight Dimension (mm) 270g 70(W) * 120(H) * 28(D) Temp used. Air temp 0 ~ 40 Air moisture Under 80 %