Inductive sensor NI3-EG08K-Y1-H1341

Similar documents
Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor With analog output BI15-M30-LI-EXI

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Capacitive sensor BCT5-S18-UP6X2T-H1151

Read/Write Head TN-M30-H1147

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Read/write head TN-M18-H1147

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Read/write head TN-CK40-H1147

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Read/Write Head TN-CK40-H1147

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Read/Write Head TNSLR-Q42TWD-H1147

Read/Write Head TNLR-Q80L400-H1147L

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

APPLICATIONS. Automatic warehouse. Trasportation lines

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

APPLICATIONS. Automatic warehouse. Trasportation lines

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SERIES 400 SERIES 620

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Photoelectrics Through-beam Type PA18C.T..., DC

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

TFRN Industrial RTD temperature sensor. CombiTemp TM

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

TFRN Industrial RTD temperature sensor. CombiTemp TM

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Pendant Light Fitting IEC Series 6470/2

Sensor technologies Proximity sensors Series ST4. Brochure

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

EXPlora. Introduction

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 331i / DMP 333i LMP 331 i

Pressure sensors with display

Selection matrix for electronic pressure switches

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

TFR5 Room or outdoor temperature sensor. CombiTemp TM

>Inductive and CATALOG. Capacitive Sensors

Pressure transmitter For applications in hazardous areas Model IS-3

>Inductive. REFERENCE guide. Proximity

Process transmitter RMA422

The full range of performance

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Mechanical flow switch for On/Off control

7 Lighting Technology

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Datasheet - SRB-E-201ST

PMG. Vibration Energy Harvesters

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Cylindrical Photoelectric Sensor CY-100 SERIES

PROPORTIONAL VALVES Sentronic plus

Bimetal Temperature Switch

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Quality products from a single source

3 Cleaning. 4 Technical data

>Inductive and. REFERENCE guide. Capacitive Sensors

Photoelectric Sensors E3F2

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12 x 1 male connector Type designation Ident no. 1003720 Wiring Diagram Rated switching distance Sn 3 mm Mounting conditions Non-flush Secured operating distance ð (0,81 x Sn) mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption 2-wire, NAMUR 5 khz Nom. 8.2 VDC ï 2.1 ma ð 1.2 ma Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil. Approval acc. to KEMA 02 ATEX 1090X Design Threaded barrel,m8 1 Dimensions 39 mm Housing material Stainless steel, 1.4427 SO Active area material Plastic, PA12-GF20 Max. tightening torque housing nut 5 Nm Electrical connection Connectors, M12 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 1 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Distance D Distance W Distance T Distance S Distance G Distance N 3 x B 3 x Sn 3 x B 1.5 x B 6 x Sn 2 x Sn Diameter active area B Ø 8 mm 2 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories IM1-22EX-T 7541232 Isolating switching amplifier, 2-channel; 2 transistor outputs; input NAMUR signal; selectable ON/OFF mode for wirebreak and short-circuit monitoring; switchable between NO / NC mode; removable terminal blocks; width 18 mm; universal voltage supply unit BST-08B 6947210 Fixing clamp for threaded barrel devices, with dead-stop; material: PA6 QM-08 6945100 Quick-mount bracket with dead-stop, chrome-plated brass, male thread M12 x 1. Note: The switching distance of proximity switches may be reduced through the use of quick-mount brackets. MW-08 6945008 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) BSS-08 6901322 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene 3 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories MBS80 69479 Mounting bracket for threaded barrel devices; material mounting block: Anodized aluminium IMC-DI-22EX- PNO/24VDC 7560003 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply Wiring accessories RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight, 2-pin, cable length: 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see www.turck.com RKC4.221T-10/TEB 6628422 4 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Wiring accessories WKC4.221T-2/TEB 6628427 WKC4.221T-10/TEB 6628429 5 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25 +70 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 6 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com