A guide to Woolworths Limited additional requirements. for the testing of twisted pair and fibre installation.

Similar documents
SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

1.0 GENERAL. 1.2 SUMMARY.1 Section Includes:

The University of Texas at Austin September 30, 2011

DESIGN!!GUIDELINES!!!!!

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

RCIT Cable Certification Testing Revised 10/2017

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

SECTION COMMUNICATIONS HORIZONTAL CABLING

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

LCS2 Cat. 6 RJ 45 Patch panels and units

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

SECTION TESTING OF COPPER CABLES

Challenges for testing 10GBASE-T

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

The need for Encircled Flux, real or imaginary?

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

Term 1 Grade 11 -Task Sheet 2. Group: N/A (Not Applicable) Finishing Time: Make a CAT5 cable. Picture 1. Picture 2

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Mar11 Rev E

How to accelerate your cabling system approvals

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

AS/NZS 1367:2016. Australian/New Zealand Standard

CAT6Plus System. Brand-Rex Limited

Connectix Cabling Systems

Volition TM RJ45 K5e Jacks

Follow The Leader In Shielded Technology

Compact Module. Category 6 FTP Cabling System

HighBand 25. TrueNet Category 6 Solutions

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Cable harness for bodywork functions

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

SC8108-A. NetWork Cable Tester. User Operation Manual. Taking Its Source At Sanling Science & Technology Good helper to network

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Specification of Fusion Splice Loss - FIA TSD Mike Gilmore FIA Technical Director

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

Datasheet: MultiFiber Pro Update

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Australian and New Zealand Energy Performance and Marking Requirements for External Power Supplies

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

HI-DEX PRODUCT SET DATASHEET

Advanced Test Equipment Rentals ATEC (2832)

Datasheet: MultiFiber Pro

Do you know if your Cat. 6 patch cord has been tested according to standards?

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

Fiber Optic Meter Fiber Optic Source

HARTING Ethernet cabling cables and connectors, 4 wire

What really changes with Category 6

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

3M 8900 Single-mode SC Crimplok Connector

NAVSEA STANDARD ITEM. 1.1 Title: Fiber Optic Component; remove, relocate, repair, and install

HDBT Installation Guide

Draft for Public Comment

Enterprise Networks. Comms Room and Backbone. in DETAIL

Telecommunication Infrastructure Project September 20, 2002

Section Communications Optical Fiber Backbone Cabling

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

TP-5290 TRBO PANEL Emergency Display Panel

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Telecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components

Project No. # Page 1

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Datasheet: SimpliFiber Pro

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Copper Cabling Troubleshooting Handbook

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Preparing a home for TransACT fibre-to-the-premise (FTTP) services

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

STRUCTURED CABLING SYSTEMS (SCS)

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

MT Connect Pre-Terminated Fibre Cabling Systems

Arista 40G Cabling and Transceivers: Q&A

STRUCTURED CABLE SYSTEM (SCS)

ETSI ES V1.1.1 ( )

LCS 2 RJ 45 Cat. 6A HD panels and units

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

Structured Cabling Introduction & Installation Guide

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Platinum Tools Inc. All rights reserved. 5/12 Voice, Data, Video + Length GENERAL SPECIFICATIONS WARNINGS

SECTION COMMUNICATIONS HORIZONTAL CABLING

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

AES standard for audio connectors - Modified XLR-3 Connector for Digital Audio. Preview only

LAN Network Tester LAN Network Tester

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

Class E A / Cat.6A Screened Coupler

PREMIUM 5e F/UTP PRODUCTS

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Monash University. Communications Cabling Manual. (Sites running legacy PABXs)

Magic Patch Patch Leads & Accessories

Transcription:

22 nd August 2013 A guide to Woolworths Limited additional requirements for the testing of twisted pair and fibre installation. Background This document has been prepared by VTI Services and approved by Woolworth s Limited to provide guidelines to the additional requirements for the testing of Woolworth s Limited sites. Document Limitation This document is provided for guidance only. All care has been taken in the creation of the document; however no claim that any or all issues have been identified and no responsibility will be accepted for its use. This document reflects VTI Services understanding of Woolworth s Limited requirements at the time of publication; however should there be conflict between this document and the Woolworth s Limited requirements, Woolworth s Limited requirements takes precedence. The testing requirements of Woolworth s Limited may change at any time without notice. Specifications should be read to determine testing requirements before testing is undertaken. General Requirements Independent test result analysis In the interests of ensuring compliance of the performance of the installed cabling system against Australian/New Zealand and specific Woolworth s Limited standards, it is a requirement that all SCS cabling test data be verified by an approved NATA Inspection Body. This effects all installations, irrespective of the communication contractor or structured cabling system vendor installing communication cabling systems within Woolworth s Limited locations. CR004-Woolworths- Testing Guide V1.9 Page 1 of 5

Woolworth s Limited require on nominated projects that the fibre and twisted pair test results be submitted to an approved NATA accredited inspection body for evaluation. The associated Statement of Compliance and report form part of the acceptance requirements of the project. Woolworth s Limited s approved NATA Inspection body VTI Services 16 Banbury Crescent Chipping Norton.NSW.2170 Telephone: 61-2-98242412 Email: office@vti.net.au Contact: Murray Teale Woolworth s Limited requires the verification of test data to Australian and New Zealand Standards along with specified additional Woolworth s requirements Woolworth s Limited additional requirements form part of the compliance of the report and may include additional elements not associated directly with testing. 1. It is a Woolworth s Limited requirement that all reports generated against Woolworth s Limited requirements be issued from the inspection body directly to Woolworth s Limited at the time of creation This provides Woolworth s Limited a mechanism to carry out a risk assessment of a site and allow for the installation to be accepted before a Statement of Compliance has been issued. This acceptance before a Statement of Compliance has been issued minimises the potential delay in practical completion and/or acceptance of a project Test Equipment All test equipment shall be in calibration at time of testing CR004-Woolworths- Testing Guide V1.9 Page 2 of 5

Twisted Pair Requirements Test Requirements Permanent link testing shall be carried out to the compliance requirements of AS/NZS3080 Permanent Links. Correct adaptors shall be used for all testing (Channel adaptors are unacceptable for permanent link testing). Marginal/Conditional Passes (Pass*) are not acceptable Full Plot Data shall be present. Test results shall be provided electronically. Approved Testers Twisted pair testers utilised for testing of Woolworth s Limited installations shall meet defined requirements. Testers meeting these requirements which have been approved by Woolworth s Limited include: o Fluke DTX1200-Fluke DTX1800. o Wirescope 350 and Wirescope PRO. Fibre Requirements Permanent link testing shall be carried out to the compliance requirements of AS/NZS3080 for all fibre cores. LSPM testing shall be carried out in two directions and at two wavelengths on all installed links. LSPM Test results will be provided electronically in the testers native format along with VTI Services fibre reporting sheet. The Woolworth s fibre reporting sheet forms part of the Additional Criteria Form and is available on VTI Services Website www.vti.net.au under downloads. Optical fibre mated connectors shall meet the following minimum optical return loss requirements. o 20 db for Multi-mode. o 35 db for Single-mode. o Testing of ORL is not required outside of visual inspection of the interface connector. The pass fail criteria will be that specified within AS/NZS ISO/IEC 14763.3. CR004-Woolworths- Testing Guide V1.9 Page 3 of 5

Woolworth s Limited Specific Requirements Necessary reporting including Woolworths additional information, Fibre reporting Sheet and TCA1 Form, shall be provided along with Test results. Without this information assessment of test data cannot take place; deeming the site as Non- Compliant. The Woolworth s Additional Criteria Form is available on VTI Services Website www.vti.net.au under downloads. Any Backbone and MDF/IFD/TPF to BD tie cables shall be tested for wire map and the results submitted for verification. All new projects depending on store types require backbone test results be provided (This is for groups of results not individual tests). Please note- Required TP Backbone : Store type 1 -nil. Store type 2- nil. Store type 3 - Backbone 25pr (1 group of 6 [4pr] cables) Store type 4 - Backbone 25pr (2 groups of 6 [4pr] cables) Store type 5 - Backbone 25pr (3 groups of 6 [4pr] cables) Store type 6 - Backbone 25pr (4 groups of 6 [4pr] cables) Backbone will be assessed against: Wire-map. Length. Continuity. All new projects require tie cabling test results to be provided The tie cable shall be tested as single pairs. Each single pair that connects MDF/IFD/TPF to BD shall be tested for: Wire-map. Continuity. The SCS BD side of 25-pair UTP MDF/IDF/TPF Tie cables shall be terminated within the SCS BD onto a CAT6 patch panel, with each pair of the 25-pair cable terminated on a port on the CAT6 patch panel, As shown in the below table; *Please note: The 25 th Pair is required to be terminated CR004-Woolworths- Testing Guide V1.9 Page 4 of 5

25-Pair number Mate Colour CAT6 Patch panel 1 White Blue Port 1 Pin 4/5 2 White Orange Port 2 Pin 4/5 3 White Green Port 3 Pin 4/5 4 White Brown Port 4 Pin 4/5 5 White Grey Port 5 Pin 4/5 6 Red Blue Port 6 Pin 4/5 7 Red Orange Port 7 Pin 4/5 8 Red Green Port 8 Pin 4/5 9 Red Brown Port 9 Pin 4/5 10 Red Grey Port 10 Pin 4/5 11 Black Blue Port 11 Pin 4/5 12 Black Orange Port 12 Pin 4/5 13 Black Green Port 13 Pin 4/5 14 Black Brown Port 14 Pin 4/5 15 Black Grey Port 15 Pin 4/5 16 Yellow Blue Port 16 Pin 4/5 17 Yellow Orange Port 17 Pin 4/5 18 Yellow Green Port 18 Pin 4/5 19 Yellow Brown Port 19 Pin 4/5 20 Yellow Grey Port 20 Pin 4/5 21 Violet Blue Port 21 Pin 4/5 22 Violet Orange Port 22 Pin 4/5 23 Violet Green Port 23 Pin 4/5 24 Violet Brown Port 24 Pin 4/5 25* Violet Grey Port 24 Pin 1/2 CR004-Woolworths- Testing Guide V1.9 Page 5 of 5