Flexible Counter Series in DIN size 24 x 48 mm

Similar documents
Flexible Counter Series in DIN size 24 x 48 mm

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Operating instructions Electronic preset counter Type series 717

Eaton Durant. Counters, process instruments and hour meters.

Multifunction devices

Preset counters, electronic

Preset counters, electronic

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

02/11/2015

Hour Meters / Timers, electronic

Counting and Process Technology 2009 / 2010

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Operating Instructions

Time meter electronic

Pulse Counters, electronic

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Counters. 1/32 DIN), programmable preset counter/timer with an integrated RS-485 communication port.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Solution Selection Guide

Operating Instructions

Lecture 14: Computer Peripherals

Preset counters, electronic

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

Single Axis Position Controller

DCP100 Digital Control Programmer Specifications


UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Self-powered Totalizer

Multifunction Digital Timer

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Simply clever! The digital DIN-rail time switches by Grässlin

Absolute Encoders Multiturn

Self--powered Time Counter

K3NC Panel Meter for Up/Down Counting will be Discontinued March 2006, Replaced by K3HB-C

Electronic Pulse Counter Combination device

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

ENC-CK58SN-L R-L1

A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter

48x24. Options ORDER NUMBER OF TYPE PFL B

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Agilent 5345A Universal Counter, 500 MHz

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Self-powered Totalizer New H7E

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

Counting Technology Counters, Timers, Tachometers

Solution Selection Guide

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

ALLEN BRADLEY TIMING RELAY

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

LAUREL ELECTRONICS, INC.

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

MODULAR DIGITAL ELECTRONICS TRAINING SYSTEM

Bedienungsanleitung KCT2-6ST-V KC-LED-96-1T-24VDC

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

02/11/2015

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

User s Manual of Signal Level Meter TABLE OF CONTENTS

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

EasyReader Model ER2C

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

(Cat. No IJ, -IK)

EasyReader Model ER4C

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

Magnecraft Power Relays

SCALE & WEIGHT DISPLAYS

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Solid-State Digital Timer

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of

Label Applicator HERMA 400

AF-300 E11 Adjustable Frequency Drive

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

PRINCIPLES AND APPLICATIONS

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

Process Transmitter RMA 422

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Digital (5hz to 500 Khz) Frequency-Meter

Agilent Technologies 54522A

ENC-MC58SN-L R-L1

Bimetal Temperature Switch

1.2 General Description

FRQM-2 Frequency Counter & RF Multimeter

Transcription:

Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or maintenance-free and environmentally friendly with 12-24 VDC supply also high-voltage input 12-250 VAC/VDC up to 8 different functions for each standard model: 01 Pulse counter 02 Tachometer (1/min) 03 Time counter (display in hhhh:mm:ss) 04 Time counter (display in hhhhhh,hh) 05 Numerical display for the PLC (serial) 06 Bidirectional position indicator 07 Counter with differential mode 08 Maintenance counter (on request) OVERVIEW Standard Models Type 1 Type 2 Type 3 Type 4 Type 5 Hardware 8-digit LCD 8-digit LCD 8-digit LCD 8-digit LCD 6-digit LED Supply voltage Lithium battery 12 24 VDC Lithium battery 12 24 VDC 12 24 VDC Nominal data 7 years NV-FRAM 7 years NV-FRAM NV-FRAM retention > 10 years > 10 years > 10 years x x x x x negative or positive edge programmable < 0.7 and < 0.7 and < 3 V and < 0.7 and < 0.7 and > 5 V, max. 30 V DC > 5 V, max. 30 V DC > 12 V > 5 V, max. 30 V DC > 5 V, max. 30 V DC max. 250 V DC/AC max. 7.5 khz or max. 7.5 khz or 20 Hz max. 7.5 khz or max. 7.5 khz or programmable 30 Hz attenuated 30 Hz attenuated 30 Hz attenuated 30 Hz attenuated Control inputs and Keylock and Keylock and and application input application input Keylock external input programmable external input programmable programmable depth 32 mm 32 mm 60 mm 60 mm 60 mm Software Impulse counter x x x x x Tachometer 1/min x x x x Time counter h : 1/100 hx x x x x Time counter h : min : s x x x x x Numerical display for PLC x x x Position indicator x x bi directional Counter with differencial mode x Maintenance counter (on request) x 202 Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 1 lithium battery RESET: reset input with contact (negative, 30 Hz) KEYLOCK: locking of the reset key short case Input resistance < 50 kohm (static) Supply voltage U b internal lithium battery Nominal data retention lithium battery: 7 years Inputs: reset lock voltage input up to 30 Hz: < 0.7 V and > 5 V, max 30 V DC programmable: 30 Hz (attenuated for contacts) - manual reset via keyboard (can be locked) - external reset with static behaviour, active edge negative by means of bridge on keylock input to 0 V Model 0 731 1 0 3 S 0 731 1 0 4 * * Option: with plug-in screw terminals Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 203

Technical data TYPE 2 DC supply voltage 12 24 V DC RESET: reset input with contact (negative, 30 Hz) short case Input resistance < 50 kohm (static) Supply voltage U b 12 24 V DC Current consumption DC 12 24 V DC < 5 ma Nominal data retention nonvolatile memory > 10 years Inputs: lock voltage input up to 30 Hz: < 0.7 V and > 5 V, max 30 V DC programmable: 30 Hz (attenuated for contacts) - manual reset via keyboard (can be locked) - external reset with static behaviour, active edge negative attenuated 30 Hz programmable via front key DATA CLOCK Model 0 731 2 0 3 S 0 731 2 0 4 * * Option: with plug-in screw terminals 05 numerical display for PC 204 Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 3 Lithium battery COUNT: Start input for voltage pulses 12-250 V AC/DC (20 Hz) RESET: reset input for voltage pulses 12-250 V AC/DC (20 Hz) KEYLOCK: locking of the reset key long case Input resistance < 50 kohm (static) Supply voltage U b internal lithium battery Nominal data retention lithium battery: 7 years Current consumption DC lithium battery: 7 years Inputs: lock high voltage input 20 Hz: < 3 V and > 12 V, max. 250 V DC/AC voltage input positive edge 20 Hz - manual reset via keyboard (can be locked) - external reset with static behaviour, positive circuit by means of bridge on the keylock input Typ 0 731 3 0 3 0 731 3 0 4 or Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 205

Technical data TYPE 4 12-24 V DC supply voltage INPUT 2: control input for temporary hold of display value (Hold) RESET: reset input OUT: transistor output for preset signal Long case Input resistance < 50 kohm (static) Supply voltage U b 12 24 V DC Current consumption DC 12 24 V DC < 50 ma Nominal data retention nonvolatile memory > 10 years Count input: voltage input up to 30 Hz: < 0.7 V and > 5 V, max. 30 V DC programmable: 30 Hz (attenuated for contacts) manual reset via keyboard (can be locked) external reset with static behaviour, 30 Hz attenuated same edge as with count input Input 2: Hold lock programmable via front key Transistor output signal PNP output Voltage/switching current voltage supply minus 2 V; max. 10 ma 12-24 VDC 0 V Count Input 2 Tr. out Model 0 731 4 0 3 0 731 4 0 4 05 numerical display for PLC 06 bidirectional position indicator 206 Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data TYPE 5 LED display 12-24 V DC supply voltage INPUT 2: control input for temporary hold of display value (Hold) RESET: reset input OUT: transistor output for preset signal Long case Front panel cutout 45 + 0,6 x 22 + 0,3 mm Input resistance < 50 kohm (static) 6-digit LED, 7 mm Supply voltage U b 12 24 V DC Current consumption DC 12 24 V DC < 50 ma Nominal data retention nonvolatile memory > 10 years Count input: Input 2: lock Transistor output signal Voltage/switching current voltage input up to 30 Hz: < 0.7 V and > 5 V, max. 30 V DC programmable: 30 Hz (attenuated for contacts) manual reset via keyboard (can be locked) external reset with static behaviour, 30 Hz attenuated same edge as count input Hold programmable via front key PNP output supply minus 2 V; max. 10 ma 12-24 VDC 0 V Count Input 2 Tr. out Model 0 731 5 0 3 0 731 5 0 4 05 numerical display for PLC 06 bidirectional position indicator 07 counter with differential mode (1 khz) Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 207

Special functions SPECIAL FUNCTIONS To best match your application, you can order special functions such as prescaler value, decimal point and preset value, which are permanently set by us before delivery. With the variable prescaler value you can adapt to already existing transfer ratios of your application. Small resolutions can be shown with the decimal point, e. g. for the position indicator or the tachometer. A special feature is the possibility of displaying an information text in the display, e. g. for the surveillance of maintenance cycles. In this case the desired information is shown in the display after reaching the fixed preset value. You can display any text that can be created with the 7-segment alphabet, e. g. STOP, HELP, FILTER etc. SPECIAL VERSIONS Special functions Impulse Tacho- Time Numerical Position Counter with for counter meter counter display indicator differential work Prescaler value x x x x 0,001 bis 99,999 Decimal point x x x x 0 to 3 positions behind the comma Preset value x x 0 to 99 999 999 Information text x x (on reaching the preset value) LCD = 8 characters LED = 6 characters SPECIAL VERSIONS Choose version and basic function: Model 0 731 7 * S * Option: with plug-in screw terminals only for standard model 1, 2 Standard version: 1 Standard model 1 2 Standard model 2 3 Standard model 3 4 Standard model 4 5 Standard model 5 Function: 1 Impulse counter 2 Tachometer (1/min) 1) 3 Time counter (hhhh:mm:ss) 4 Time counter (hhhhhh.hh) 6 Position indicator (2-channel) 2) 7 Counter with differential mode 3) 1) not available for standard type 3 2) not available for standard types 1, 2, 3 3) only available for standard type 5 Please state the desired special version on your order: P: (Value); D: (Value); V: (Value); T: (Text); Prescaler value: 0.001 to 99.999 4) Decimal point: 0 to 3 positions after the comma 4) Preset value: 0 to 99 999 999 5) The information text displayed on reaching the preset value can be built up as required from the 7-segment alphabet 4) not available for time counters 5) not available for tachometers and position indicator 208 Components 2001 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS