Gamma instabus. Technical product information

Similar documents
Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

K-BUS Dimmer Module User manual-ver. 1

ABB i-bus EIB Universal dimmer 6155 EB for Installation

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

15 Series - Dimmer

Ordering details. Approval. Classification

02/11/2015

LED Driver Compact dimming

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Product Manual. ABB i-bus EIB / KNX Switch/Dim Actuators SD/S. Intelligent Installation Systems ABB

Webinar Competence Center Europe Building Automation. Ilija Zivadinovic, Martin Wichary, Juergen Schilder, Thorsten Reibel, Stefan Grosse

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Figure 1: Device components

IP Roombox. Hotel Room Management

Datasheet - SRB301LC 24VAC/DC

LED MODULES READYLINE DL

KNX Dimmer RGBW - User Manual

LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

INSTALLATION & USER GUIDE

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Electrical connection

KNX 1-10V dimmer 4 channels

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

LED Driver Compact fixed output

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Electrical connection

Manual for WMR-252 built-in receiver with universal dimmer

Datasheet - SRB-E-201ST

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Operating Instructions Dimmer for V Incandescent Lamps

Instruction manual. DALI Gateway art Installation manual

DIN Power Module - Phase Adaptive

STX Stairs lighting controller.

Switching Power Module

High performance circuit breakers

Electrical connection

Catalogue Ignitors and power switches for HID

Multi-functional safety relay modules PROTECT SRB-E

LED Driver Linear / area fixed output

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

multi-function meters

SH2RE16A4. Output relay module. Benefits. Description

Product Manual. ABB i-bus KNX DALI Gateway DG/S

Series CT7N Bimetallic Overload Relays

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Luminaire installation box Surface-mounted box Ceiling installation box

OPTOTRONIC Intelligent

MICROMASTER Encoder Module

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Capacitors and banks 50 Hz 0 400/415 V network voltage

LED control gear Compact fixed output

Operating instructions III / 2004

Operating instructions Electronic preset counter Type series 717

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Generator protection relay

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Transponder Reader TR22A01KNX TR22A11KNX. Product Handbook

QTi DALI 2X14/24/ DIM

Photoelectrics Through-beam Type PA18C.T..., DC

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.


2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

MAP110 AC-DC Series Data Sheet

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

TRF STEP-DOWN TRANSFORMER USER MANUAL

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

SceneStyle2 User Guide

Amplifier for fiber optics. Dimensioned drawing

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

CAMTO LTD. Arc detecting system DC/AC

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Capacitance Limit Detection nivotester FTC 420/421/422

Process transmitter RMA422

Standard signal metering in wall-mounting case

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

llen-bradley 194R-HM4-NFPA3

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

PowPak Dimming Module with 0 10 V Control

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Modular pulse operated latching relay 16 A

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Benefits. Applications

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

PowPak Dimming Module with 0 10 V- Control

Transcription:

Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output capacity: 4 x 300 VA, with channel bundling up to 1000 VA Protection against short circuit, overload and over temperature Direct operation for efficient installation Functions with configuration with ETS Configurable dimming curves for optimal dimming behavior Operating hours counter with threshold overrun warning Integrated 8-bit scene control and assign of each output to up to 8 scenes

Type overview Type Description Article number N 554D31 Universal dimmer 5WG1554-1DB31 Use The universal dimmer is used for switching, dimming and scene control in building automation. Device control is conducted via KNX. The universal dimmer can be used to switch and dim resistive, inductive and capacitive loads. At each output channel of the universal dimmer, a load of up to 300 VA can be connected. Neighboring outputs can be bundled (connected in parallel). With channel bundling of all four outputs, a load of up to 1000 VA can be connected to the universal dimmer. The universal dimmer is designed for installation on a DIN rail. Technical design Position and function of the connections and labeling 3 4 5 6 2 RLC 1 Pos. Element Function 1 KNX bus terminal blocks, screwless Connect KNX bus 2 Product label field Write individual address 3 Connection terminals Connect loads (phases and neutral conductors) 4 Labeling of the connections to channel A and B 5 Labeling of the connections to channel C and D 6 Membrane keypad Execute direct operation Configure channel bundling Display status of the universal dimmer 2 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Position and function of the operating and display elements 7 6 5 4 3 2 8 9 10 11 1 RLC Pos. Operating or display elements Function 1 LED (red) Button: Learn mode Short press of button (< 1 s): Activate learn mode, display status (LED on = active) Very long press of button (> 20 s) Reset to delivery state (LED starts blinking after 20 s) 2 Button: Deactivate direct operation Deactivate direct operation for all channels 3 LED (yellow): Direct operation active 4* Button: Switch off Dim darker Channel A 5* Button: Switch on Dim brighter Channel A LED flashes when direct operation is active for at least one channel. Short press of button (< 1 s): Switch off channel A and activate direct operation for channel A Long press of button (> 1 s): Dim channel A darker and activate direct operation for channel A Short press of button (< 1 s): Switch on channel A and activate direct operation for channel A Long press of button (> 1 s): Dim channel A brighter and activate direct operation for channel A 6* LED (red): Channel A LED lit: Channel switched on (dimming value > 0). LED off: Channel switched off (dimming value = 0). LED lights up with brief interruptions: Channel switched on in direct operation. LED flashing: Channel switched off in direct operation. 7* LED (red): Channel bundling A + B LED lit: Channels A and B are bundled and higher output values can be achieved. LED off: Channel A and B are not bundled. 8 Button: + Preselection button for bundling / separating neighboring channels in combination with button 5 of channel A, B or C (only in delivery state) 9 LED (red): Short circuit Short circuit detected at load output 10 LED (red): Overtemperature, overload Overtemperature or overload detected at the load output 3 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Pos. Operating or display elements Function 11 LED (red): Channel failure Power failure, error detected on channel (channel not ready) *The description of channels 4, 5, 6 and 7 applies analogously for the corresponding buttons/leds of channels B, C and D. 4 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Connection example with and without channel bundling At each channel of the universal dimmer, loads of up to 300 VA can be connected. Neighboring channels can be bundled into groups of 2, 3, or 4 channels (connected in parallel). With channel bundling of all four outputs, loads of up to 1000 VA can be connected to the universal dimmer. In the delivery state, channel bundling can be conducted directly on the device without software. Ultimately the configuration of the channel bundling is defined via the ETS software. The following channel bundling options are possible: A+B C D A+B C+D A B+C D A B C+D A+B+C D A B+C+D A+B+C+D The following circuit diagrams show four of the possible bundling variants. DANGER Make sure that it is always the same load types that are connected to a channel! Ensure that it is always only one phase (L1, L2 or L3) that is connected to the single channel or bundled channels! Example Description Maximum connection capacity 1 Operation without channel bundling of the outputs A, B, C, D: 300 VA 2 Channel A and B with channel bundling A + B: 500 VA C, D: 300 VA 3 Channels A, B and C with channel bundling A + B + C: 750 VA D: 300 VA 4 Channels A, B, C and D with channel bundling A + B + C + D: 1000 VA Example 1: No channel bundling U n ~ 230/400 V L1 L2 L3 N :B16 A A B C D + KNX- KNX+ 5 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Example 2: Channel bundling of channel A and B U n ~ 230/400 V L1 L2 L3 N :B16 A A B C D + KNX- KNX+ Example 3: Channel bundling of channel A, B and C U n ~ 230/400 V L1 L2 L3 N In In In :B16 A A B C D + KNX- KNX+ Example 4: Channel bundling of channel A, B, C and D U n ~ 230/400 V L1 L2 L3 N :B16 A A B C D + KNX- KNX+ 6 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Technical data Power supply KNX bus voltage DC 24 V (DC 21 V... 30 V) KNX bus current Voltage Supply frequency 7.5 ma AC 230 V 50... 60 Hz Outputs Rated voltage AC 230 V Rated current (per output) 1.3 A @ cosφ = 1.0 Rated frequency Power loss (per output with rated output) 50 Hz... 60 Hz 1.7 W (maximum) Connection capacity With channel bundling of Load type Per channel 2 channels 3 channels 4 channels Incandescent lamps 300 W 500 W 750 W 1000 W High voltage halogen lamps 300 W 500 W 750 W 1000 W Low voltage halogen lamps with electronic transformers Low voltage halogen lamps with magnetic transformers Dimmable energy-saving lamps (CFL) Dimmable LED Operating mode: Trailing edge operation Dimmable LED Operating mode: Leading edge 300 VA 500 VA 750 VA 1000 VA 240 VA 400 VA 600 VA 800 VA 45 VA 80 VA 120 VA 160 VA 200 VA*) 300 VA*) 450 VA*) 550 VA*) 60 VA*) 100 VA*) 140 VA*) 180 VA*) *) The max. total power depends on the lamp type and control mode. All information refers to the main installation location of the universal dimmer. Load terminals top, KNX terminals bottom. For all other installation locations, the power must be reduced to 80% of the specified values. Physical specifications Housing material Dimensions Weight Fire load Plastic Rail-mounted device in N dimension Width 8 TE (1 TE = 18 mm) Length 90 mm Height 61 mm 310 g 6 MJ 7 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Environmental conditions Ambient temperature in operation -5 C... +45 C Storage temperature -20 C... +70 C Transport temperature -25 C... +70 C Rel. humidity (non-condensing) 5 %... 95 % Climatic withstand capability EN 50428 Protection settings Degree of pollution (according to IEC 60664-1) 2 Overvoltage category (according to IEC 60664-1) III Protection class (according to EN 60529) IP 20 Electrical safety, bus Safety extra low voltage SELV DC 24V Electrical safety, device fulfills EN 50428 EMC compatibility EN 50428 Reliability Failure rate (at 40 C) 940 fit 8 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Functions Building site function The building site function makes it possible to switch building site lighting on and off without the universal dimmer having to be configured with the ETS. In the delivery state, the building site function of the universal dimmer is activated. Direct operation via the membrane keypad After the installation, the individual channels of the dimmer can be tested directly on the universal dimmer. Prior configuration via the software is not necessary for this. In the delivery state, direct operation is activated without a time limit. After configuration, direct operation is limited to the configured time limit. Operation mode for load control The universal dimmer supports two kinds of operation modes: Leading edge: For inductive or resistive loads. To achieve a better or more uniform dimming behavior with LED. Prescribed for inductive loads. Trailing edge: For capacitive or resistive loads. For controlling more lamps and higher loads as less power loss is generated. Automatic load detection When initializing the control electronics and when loading the ETS parameters, automatic load detection is executed. The universal dimmer automatically adapts the type of operating mode at an output to the connected load. Resetting the universal dimmer to factory default settings A very long push of the programming button (> 20 s) resets the universal dimmer to the factory settings. The building site function and direct operation are re-activated. Channel bundling can now again be conducted directly on the universal dimmer. Protection against short circuit In a short-circuit condition the universal dimmer turns the load off for 3 seconds and automatically tries to switch the output on to the currently set dimming value. If the short-circuit condition still persists the output is turned off permanently. Turn the output on again by receiving a telegram on or dimming value > 0. With channel bundling, there is no automatic attempt to switch back on. Protection against overload/overtemperature In case the maximum permissible temperature is exceeded, which also can indicate an overload, the universal dimmer turns off immediately. If after 1 minute the universal dimmer has cooled down sufficiently, it automatically dims back to the currently set dimming value, if there was received a telegram turn on or a dimming value > 0. Immunity to ripple control signals and electrical grid frequency fluctuations The influence of ripple control signals is compensated in order to reduce flickering of the lamps. In order to ensure mostly undisturbed operation in electrical systems without a synchronous connection to the power grid, the universal dimmer is less sensitive to frequency fluctuations in the system. 9 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Functions with configuration with ETS Version of the Engineering Tool Software and application program Application Engineering Tool Software (ETS) Application program Version ETS 4.2 and up 9A0401 Behavior with bus voltage failure/recovery When bus voltage is lost, the current switch status and dimming value status are permanently saved. When bus voltage is recovered, these values are restored. On bus voltage recovery, for each channel the configured actions are executed and, if applicable, new status values are reported. Behavior on unloading the application program If the application program is unloaded by the universal dimmer with ETS, the universal dimmer has no further function and must be reprogrammed. Timer functions When configuring the dimmer with ETS, 2 different times and night mode can be programmed. It is possible to set delayed switching on/on and a warning before switching off occurs. Overrides Via ETS it is possible to activate up to seven different override function blocks for the universal dimmer to override the automation functions. Switch cycle and operating hours count To monitor use, with the right configuration it is possible to count and display the switch cycles and operating hours of the dimmer. 8-bit scene control Using 8-bit scene control, current brightness values or switching states can be assigned to a scene and activated again later through the scene. Adjusting the dimming behavior of LED lamps With the parameter settings the dimming behavior of LEDs can be adapted to the behavior of incandescent lamps. - With minimum dimming value and maximum dimming value, the area ion which the LEDs are to be visibly dimmed can be set for each channel. - Some LEDs can only be dimmed if the maximum dimming value is set to lower than 100 %. - Some LED can be only turned on with a higher brightness value, so the LED driver gets enough power to turn on the light. This can be achieved with the parameter Start on value. Then the brightness can be dimmed down to a lower dimming value. - The dimmer contains preconfigured dimming curve with which the behavior of LED lamps can be enhanced. It is also possible to adjust the dimming curves freely if none of the preset dimming curves produce the desired result. 10 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Diagnosis functions Override functions Control functions Schematic design of a dimming channel: The following schema shows the functions of the dimmer in a logical overview. Send status value Control value Switching 0 1 Control value input Logic operation 1/2 Logic operation 1/2 Central switching 8-bit scene 8-bit scene control t Normal mode/flashing t Normal mode/ flashing Dimming Dimming value 1/2 Flashing 0 1 Night mode 0 1 Timer period day mode Timer period night mode Timer (day) 1-fold/2-fold Timer (night) Normal mode Flashing Override 1 2 Override 1 2 Status override 1 2 Global dimming Global dimming Override 3 7 Override 3 7 Status override 3 7 Direct operation lock Direct operation Status direct operation Min./Max. dimming value Min./Max. dimming value Status load adaptation Load adaptation leading/trailing edge Status Status switching Status dimming value Error Number of switch cycles Operating hours Status failure (...) Status number of switching cycles Status operating hours 11 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Notes Safety DANGER The universal dimmer should only be installed and put into operation by a certified electrician. Ensure that the universal dimmer can be activated. Do not open the housing of the universal dimmer. Only use loads that are approved for dimming operation. Only use conventional transformers that comply with the relevant standards and contain a thermal fuse. For planning and construction of electricc installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Do not operate inductive loads in trailing edge mode. Ensure that it is always only one phase (L1, L2 or L3) that is connected to the single channel or parallel-connected channels! Installation notes The universal dimmer can be used for fixed installations in interior spaces, for installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35. Dimmable LEDs and energy saving lamps (ESLs) When connecting LED lamps, LED drivers and energy-saving lamps, it must be ensured that they are designed for dimming and which operating mode (leading edge mode or trailing edge mode) is used. Manufacturers indicate whether a lamp is dimmable or not with a symbol on the package. Manufacturers also specify the recommended operating mode on the package. Irrespective of which operating mode is set by the device for automatic load detection, the operating mode specified by the manufacturer must always be selected. 12 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Commissioning and decommissioning Connecting loads Cu 0.5 2.5 mm² 2.5 mm² Connecting KNX Cu 0.6 0.8 mm Test of KNX 24VDC type SELV This test can be used to check whether the bus connection cable is connected with the correct polarity and whether the universal dimmer is supplied with bus voltage. 13 / 15 2018 P.O. Box 10 09 53, D-93009 Regensburg

Dimensions 55 mm [2.17 in] 44 mm [1.73 in] 90mm [3.54in] RLC 144 mm [5.67 in] 61 mm [2.40 in] 14 / 15 P.O.Box 10 09 53, D-93009 Regensburg 2018

Product documentation Support Related documents such as the operating and mounting instructions, application program description, product database, additional software, product image, CE declaration etc. is available at the following internet address: http://www.siemens.com/gamma-td General information The operating instructions must be handed over to the client. A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. If you have further questions concerning the product, please contact our technical support. & +49 911 895-7222 6 +49 911 895-7223 ) support.automation@siemens.com http://www.siemens.com/automation/support-request Published by P.O. Box 10 09 53, D-93009 Regensburg 2018 Copyright