INSTRUCTION MANUAL. H4 PV Cable Connector Series Dual Approval (UL+IEC/TUV)

Similar documents
ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

MCX Miniature Coaxial Connectors

3M Locator Plate N

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

AMERICAN NATIONAL STANDARD

OCT 15 Rev B

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

Assembly Instructions

Amphenol RF Connectors

EXPlora. Introduction

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

Pivot Power RJ45 Modular Plug Connectors

HARTING Ethernet cabling cables and connectors, 4 wire

Non Magnetic Connectors

INSTALLATION AND OPERATION M

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

ENGINEERING COMMITTEE

Power Injector 1520 Series

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Caution. Hanging the Screen:

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Specification for F Connector, Male, Pin Type


Ultra-Grip 2 Crimp Connector Hand Tool Kit for Crimp Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

Stainless Steel SMA Connectors Product Catalog

Reverse polarity connectors

AMP+ HVA280-2phm High-Voltage Plug Connector with Shunted HVIL

Site Installation Model MP-8424

8D with High Frequency Coaxial Contact

SMA One Piece Semi-Rigid Connectors

VITALink Taped Splice Straight Through Crimp

Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC)

Head Office: T: F: Scotland: T: F:

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

PERFORMANCE SPECIFICATION SHEET

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

High Density BNC Connectors

NewScope-7A Operating Manual

Precision TNC Coaxial Calibration Kit

BNC 75 RF CONNECTORS. Simple steps to guide you in using this catalogue. Applications. Options. Ordering Codes BNC 75 RF CONNECTORS

DFLK-D37 SUB/S. Extract from the online catalog. Order No.:

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Look No Further... Materials & Finishes. Specifically made for all your: Gigabit Ethernet, HDMI, USB 2.0/3.0 Needs! onnectors

General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

LCC (Little Coaxial Connector) Installation Instructions)

Information on new products!

Table 4-1: Rating Levels

Hardware installation

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

(E-UB) UPRIGHT BIKE INSTALLATION INSTRUCTIONS

BTT rev. a Bob s TechTalk #8

Crimp & Cleave Termination Instructions for SEL ST Connectors

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

Assembly instructions

Satellite Dish Installation Manual (Ver. 2) 1

Building a MidiBox LCD Cable

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Site Installation Model MP-8433

Tools Amphenol CTL Crimp Series

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

Amphenol RF. Tools. Tools. Tools. Description. Tool Series

Proper Installation of SCR s will Extend Life Author - George A. Sites, AMETEK HDR Power Systems

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Size B INDUSTRIAL STANDARD

Instructions. Cable with Armor F CAUTION. October Rev A

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Ribbon Cable connector Compliant with MIL Standard

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Lumination TM LED Luminaire LUS Series

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

SQM40/41 Actuators for air and gas dampers

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

SUHNER QMA SUBMINIATURE CONNECTORS

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

TracVision 95W LNB Installation

Cellular Signal Booster

Wire Connectors FAX WIRE CONNECTORS. Quick, reliable splices are a snap and a squeeze

LED Backlight for Technics amplifiers

User Guide. Automated Tuner. Model MT981HL Series. MT (Rev A) 1/13

SMA - 50 Ohm Connectors

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES TNC (CABLED), PIN CONTACT, RIGHT ANGLE, CLASS 2)

TECHNICAL GUIDE. TOUGH GUN ThruArm G1 Series Robotic MIG Guns for Motoman Robots EA1400N, EA1900N and SSA2000

Amphenol LTW Innovation in Waterproof Solution

Series MCX 50 micro miniature connectors

Transcription:

H4 PV Cable Connector Series Dual Approval (UL+IEC/TUV) REVISION RECORD REV DESCRIPTION DATE A FIRST RELEASE July/28/2011 B IMPROVED LAYOUT Sep/6/2011 C UPDATE TORQUE Nov/3/2011 D UPDATE THE S&F REQUIREMENT Dec/8/2011 E ADD ENLARGE H4 REQUIREMENT July/24/2012 F UPDATE ELECTRIACL RATING Aug/22/2013 File Name: PV 692239 000 Page 1 of 8

Electrical rating: 1500V DC (IEC/TUV) 1000V DC (UL) Current rating: 32A (2.5mm²/14 AWG) 40A (4.0mm²/12 AWG) 44A (6.0mm²/10 AWG) 65A (10mm²/8 AWG) Protection degree: IP68 mated and IP2X unmated Safety class: II Operation Temperature Range: 40 to +90 CAUTION: 1) The connector must be isolated and disconnected from the power supply during the assembling or disassembling process. 2) Do not disconnect under load. 3) The use of PV cable is recommended. 4) The use of tin plated cable is recommended. 5) The connectors are IP68 rated, and can be positioned for short time under 1MT of water. 1) Product picture: File Name: PV 692239 000 Page 2 of 8

2) Connector part numbering: 3) Stamped and formed contact part numbering: Note: Machined and screw contact are supplied standard with the connectors. File Name: PV 692239 000 Page 3 of 8

4) Required tools: Crimp tool for machined contacts: H4TC0001 Crimp die for machined contacts: H4TD0001 Crimp tool stamped and formed contacts: H4TC0002 TBD Crimp die for stamped and formed contacts: H4TD0002 TBD Strip tool for 2.5/4.0/6.0mm² PV cable: H4TS0000 Wrench tool: H4TW0001 Open end back cap spanner: H4TE0000 File Name: PV 692239 000 Page 4 of 8

Socket wrench: H4TF0000 Complete tool kit for installers: H4TK0000 5) Cable preparation and stripping process: Strip cable 0.276 inches (7.0 mm ) and be careful NOT to nick conductors. Amphenol specified strip tool (H4TS0000) can be used in this step. Adjust the striper stopper and put the cable in corresponding notch to strip the length of 7mm. See below pictures 1 and 2. Picture 1 Picture 2 6) Crimp process machined contacts: Insert striped cable into contact barrel and insure all conductor strands are captured in the contact barrel and the conductors are visible in the inspection hole. See below pictures 3 and 4 Picture 3 Inspection hole Picture 4 Crimp contact barrel by using the hex or 4 ident crimping die, by putting the contact barrel with striped cable in the corresponding crimping notch or locator. See below picture 5 and 6. Amphenol specified strip tool (H4TC0001) can be used in this step. File Name: PV 692239 000 Page 5 of 8

Female contact Male contact Picture 5 Picture 6 See below pictures 7 and 8 for crimp result for hex crimp and pictures 9 and 10 for the 4 ident crimp result Picture 7 Picture 8 Picture 9 Picture 10 The pull out forces requirement will have to be the following: Cable size Cable pull out force requirement 2.5 mm² Min. 230 N 4.0 mm² Min. 310 N 6.0 mm² Min. 360 N 10.0 mm² Min. 380 N 7) Crimp process stamped and formed contacts: Insert striped cable into contact barrel and insure all conductor strands are captured in the contact barrel. See below pictures 11 and 12. Picture 11 Picture 12 Crimp contact barrel by using the crimping die, and be careful NOT to hurt the second row wings See below pictures 13 and 14 for crimping result. Picture 13 Picture 14 File Name: PV 692239 000 Page 6 of 8

Amphenol specified crimp tool (PV 692209 000) can be used in this step. If the customer wants to use the automatic crimping machine, we suggest that the die of the machine should be like the following: Cable Size Crimping Height(A) Crimping Width(B) 2.5mm 2 2.45±0.05mm 2.80±0.10mm 4.0mm 2 2.30±0.05mm 4.50±0.10mm 6.0mm 2 2.42±0.05mm 4.50±0.10mm Cable size Cable pull out force requirement 2.5 mm² Min. 230N 4.0 mm² Min. 310N 6.0 mm² Min. 360N 8) Termination process screw contacts: See below pictures 15 and 16 for screw result for Allen driver (2mm). Picture 15 Picture 16 9) Assembly process connector: Insert contact cable assembly into back of male and female connector. A click should be heard or felt when the contact cable assembly is seated in correct position. Contacts cannot be removed once seated. See below pictures 17 20. Female coupler Male Coupler Picture 17 Picture 18 Picture 19 Picture 20 H4 PV cable connector back cap must be closed using a torque between 2.6 and 2.9 N M and Enlarge H4 PV cable connector back cup must be tightening between 3.2 to 3.5 N M. Note: These torque force apply to Amphenol PV cable only. And H4 PV connector should have different torque force for different customer PV cable. File Name: PV 692239 000 Page 7 of 8

Amphenol specified wrench tool (H4TW0001) can be used in this step or electric torque controlled wrench tool with as well the Amphenol open end back cap spanner (H4TE0000). See below picture 21 and 22. Note: Pneumatic wrench tools are NOT recommended since torque control is very difficult. Picture 21 Picture 22 10) Connector mating and un mating: For mating align the 2 half connectors and mate them together by hand until a click is heard and/or felt. For un mating, since the Amphenol H4 connector complies with the NEC 2008 690.33, a tool is required to disconnect the connector once mated. Amphenol specified wrench tool (H4TW0001) or Universal tool (H4TU0000) should be can be used in this step. See below picture 23 and 24. WRENCH TOOL DISCONNECT UNIVERSAL TOOL DISCONNECT Picture 23 Picture 24 File Name: PV 692239 000 Page 8 of 8