Danfoss Icon Programmable Room Thermostats, 230 V

Similar documents
DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Luminaire installation box Surface-mounted box Ceiling installation box

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Linear / area fixed output

LED Driver Compact fixed output

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Automatic Transfer Switch Control PLC Operator s Manual

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

LED Driver Compact fixed output

Switching Power Module

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

LED control gear Compact fixed output

Actuators IC 20, IC 30, IC 50

OP5. Preprogrammed, configurable controller for simple applications

Innovative Air Systems ABN When Calling For Support Quote:.doc

Nessie Coils for VDH and VDHT valves

Benefits. Applications

Linear flow controls VFC Linear flow controls with actuator IFC

Proportional output thumbwheels - sprung to centre

Roof-mounted Blue e+ cooling unit Integration solution VX25

Hour Meters / Timers, electronic

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LED Driver Compact fixed output

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LED Driver Compact dimming

Emergency lighting units EM powerled

Linear flow control with actuator IFC

Capacitance Limit Detection nivotester FTC 420/421/422

Level Measurement silometer FMC 420, FMC 423

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

7 Day Digital Programmer 3 Channel Surface Mount

Catalogue Ignitors and power switches for HID

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Altman Lighting AP-150 RGBW Par Specification

GB-ER series. Direct connection to LH70/71 series

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LED MODULES READYLINE DL

Master Clock Controller. User Guide. pyramidtimesystems.com

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

APPLICATIONS. Automatic warehouse. Trasportation lines

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Master Clock Controller. User Guide. pyramidtimesystems.com

multi-function meters

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Lt DELTA USA, Inc

10 SERIES. Light dependent relays A

Master Clock Controller. User Guide. pyramidtimesystems.com

FEATURES. Output 30 W Light Engine CCT, CRI Lumen Output Efficacy Peak Intensity

Digital Clock with Second Circle DA Series

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

OPTOTRONIC Intelligent

Single Point Flow Monitor SW118 SW119

Scan-Line 8. PRICE LIST 2017 EN (VAT EXCLUDED) Valid from

Model KBF 1020 Constant climate chambers with large temperature / humidity range

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

2-output DALI controller

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Emergency lighting units EM powerled

SAUTER flexotron RDT405 Manual

INSTRUCTION & INSTALLATION GUIDE

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Model KBF 115 Constant climate chambers with large temperature / humidity range

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Pulse Counters, electromechanical

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

NEA WIRING CENTRE NEA HT 230V /24 V

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Safety Light Curtains GuardShield

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Generator protection relay

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

TUC: Universal thermostat

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

DIN Power Module - Phase Adaptive

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

LARGE DIGITAL LED REAL TIME CLOCKS

Features. Specifications. Finish. Notes

Panel-mounting thermostats, type series EM

Mechanical flow switch for On/Off control

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

02/11/2015

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Transcription:

Danfoss Room Thermostats, 230 V Description Danfoss 088U1020 Danfoss Icon is a range of flush and surface mounted room thermostats for hydronic floor heating applications. Danfoss is mains powered and can be used as a stand-alone thermostat or in combination with wiring center 088H0016. The thermostat uses a triac output and can control up to 5 thermal actuators. The user can choose between 7 pre-defined heating schedules. A schedule can be temporarily overrided by using the three mode keys. The thermostat can also operature without scheduling (constant room temperature setpoint). The thermostat uses forecast (adaptive learning). The thermostat uses a touch on glass interface with a shine through display. The display is OFF in normal operation. Danfoss 088U1025 Features Accurate PW-control Compatible with 3 rd party wall frames Shine through display with mode keys 7 pre-defined schedules and forecast Range limitation via user menu eutral design and simple user interface Frost protection setting Can be used with 230V C or O actuators Can be optimized for different heatsources via service menu Valve exercise feature Can be used in systems with cooling Has input for global setback Can be used with floor sensor (optional) Very high UV-resistance Ordering Product Version Size For junction box Code no. Danfoss In-wall 80 x 80 mm Euro, Ø68 mm 088U1020 Danfoss In-wall x mm Square, 70x70 mm 088U1021 Danfoss In-wall 88 x 88 mm Swiss type 088U1022 Danfoss On-wall x mm.a. 088U1025 VDSUD202 Danfoss FHH 2016.05 1

Danfoss - Room Thermostats, 230 V Accessories Product Description Code no. Danfoss FH-WC, 230V Wiring center, 8 channels, up to 16 outputs 088H0016 Danfoss Icon Floor Sensor 47 kω, 3 m, IP 67 088U1110 Technical specifications Type User interface User interface features Display type Display features Real time clock Automatic daylight saving time Heating schedules Electronic thermostat with touch user interface Capacitive touch and shine through display Heating icon, arrow up/down, confirm key, back key, Home, Away, ight, Settings Hybrid: red single ED s and custom segment Switches OFF after 10 sec. with no interaction Yes, std. Gregorian calendar. 8 hrs. running reserve (new product) down to 1.5 hrs. running reserve in year 10 after installation. Standard, can be turned off 7 x pre-defined schedules (P0-P6) 5/2 days (weekdays and weekends) Temperature setting range 5-35 C (frost protection setting = 5 C) Ambient temperature, storage Ambient temperature, used in application Controller, type Change over, cooling Global setback/away ax. continuous load (output) ax. inrush current (actuator) Power consumption Power supply (excl. actuators) Sensor, room -20 to C 0 to + 40 C Adjustable Pulse Width odulation Yes, via 230 V input terminal Yes, via 230 V input terminal < 50 ma /10 W (= 5 pcs. Danfoss TWA actuators) 3 A 100 ms 0.2 W 220-240 V, 50/ Hz TC 47 kω Sensor, floor (optional) TC 47 kω, 3 m, IP 68 Shell material White parts: PC ASA Grey parts: PC, 10% glass IP and Protection class IP: 21 Protection class: II ErP class Approval Colour Dimensions, in-wall versions Dimensions, on-wall version (2%) CE, RohS, WEEE White RA9010 / Dark Grey RA7024 80 x 80 x 11 mm (088U1020) x x 11 mm (088U1021) 88 x 88 x 13 mm (088U1022) x x 25 mm (088U1025) 2 Danfoss FHH 2016.05 VDSUD202

Danfoss - Room Thermostats, 230 V Application examples Wiring without wiring center, neutral wire from main installation 6430 ordborg ax. load: 10W/50mA oad TC 0883454 v000 in. 3G1.5 cable to thermostat (not counting Protective earth) ax. 5 actuators, type C or O, 230V ax. 10 W / ax. 50 ma continuous load ax. 3 A inrush current 100 ms 6430 ordborg ax. load: 10W/50mA oad TC 0883452 v000 in. 4G1.5 cable to thermostat (not counting Protective earth) ax. 5 actuators, type C or O, 230V ax. 10 W / ax. 50 ma continuous load ax. 3 A inrush current 100 ms Wiring with wiring center 6430 ordborg ax. load: 10W/50mA oad TC 0883452 v000 OAD FH-WC 1) 088H0016 in. 3G1.5 cable to thermostat (not counting Protective Earth) ax. 5 actuators, type C, 230V ax. 10 W / ax. 50 ma continuous load ax. 3 A inrush current 100 ms 1) ote! Wiring center FH-WC 088H0016 only supports C actuators, and does not support cooling change-over or global setback. VDSUD202 Danfoss FHH 2016.05 3

Danfoss - Room Thermostats, 230 V Application examples How to set thermostats to cooling mode from external device 6430 ordborg ax. load: 10W/50mA oad TC 0883452 v000 S S: Can be mechanical switch Summer / Winter or relay activated by external device. Use the same phase which supplies the thermostat. The thermostat/room remains in cooling mode as long as the phase is live onto the terminal. ote! Switch not delivered by Danfoss. How to set thermostats to Away (global standby) from external device 6430 ordborg ax. load: 10W/50mA oad TC 0883452 v000 S S: Can be mechanical switch Home / Away or relay activated by external device. Use the same phase which supplies the thermostat. The thermostat/room remains in Away mode as long as the phase is live onto the terminal. ote! Switch not delivered by Danfoss. How to install a floor sensor 6430 ordborg ax. load: 10W/50mA oad TC 0883452 v000 1. R > 5 cm 2. Anchor electrical pipe firmly before laying concrete 3. Concrete 4. End of pipe must be closed / sealed 1. 2. 3. 4. ote! Use Danfoss 47 KΩ TC sensor, code no.: 088U1110 Always route external sensors in a suitable electrical pipe! 4 Danfoss FHH 2016.05 VDSUD202

Danfoss - Room Thermostats, 230 V Dimensions 47 71 71 80 51 11 23 Danfoss 088U1020 80 47 80 80 51 11 23 Danfoss 088U1021 47 71 71 88 51 13 23 Danfoss 088U1022 (incl. Feller EDIZIOdue frame and adapter) 88 75 25 Danfoss 088U1025 VDSUD202 Danfoss FHH 2016.05 5

Floor Heating Hydronics Ulvehavevej 61 DK-7100 Vejle Phone: +45 7488 8500 Fax: +45 7488 8501 heating@danfoss.com www.floorheating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of. All rights reserved. 6 Danfoss FHH 2016.05 VDSUD202