PROPORTIONAL VALVES Sentronic plus

Similar documents
Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331i / DMP 333i LMP 331 i

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Pressure transmitter For applications in hazardous areas Model IS-3

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Mechanical flow switch for On/Off control

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

82540/ /2-way diaphragm valves

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Pendant Light Fitting IEC Series 6470/2

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

EXPlora. Introduction

Solenoid valves VZWD, directly actuated

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Connecting cables for valves, round plug connectors Product range overview

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Inductive sensor NI3-EG08K-Y1-H1341

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Process Transmitter RMA 422

Model JDF Field Indicator

Pendant Light Fittings Series 6050

Inductive sensor NI10-M18-Y1X-H1141

Solenoid valves VZWD, directly actuated

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Linear flow control with actuator IFC

Inductive sensor With analog output BI15-M30-LI-EXI

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Single Point Flow Monitor SW118 SW119

TFR5 Room or outdoor temperature sensor. CombiTemp TM

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Veilux User Manual SVEX-Q18 Intelligence Camera Set

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Selection matrix for electronic pressure switches

2291 Guided Wave Radar Level Transmitter

TFRN Industrial RTD temperature sensor. CombiTemp TM

Inductive sensor BI1.5-EG08K-Y1

TUC: Universal thermostat

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

TFRN Industrial RTD temperature sensor. CombiTemp TM

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Connecting cables for valves, Sub-D Type codes

RSCC. Load cells. Special features. Data sheet

I Ex-protected connectors exlink I

Digital Flow Switch for Air/Water

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Linear flow controls VFC Linear flow controls with actuator IFC

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

ATEX-manual for units

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Lt DELTA USA, Inc

Installation instructions Cable transit device Roxtec RS ES Ex

Process transmitter RMA422

Micro-Machined Silicon Transducers

Magnetic Sensor - Incremental EHP

Digital Flow Switch for Water

Operating instructions

Size B INDUSTRIAL STANDARD

Horn loudspeaker, Ex proof, short/long flare

3 -color/2 -screen display

TELEDYNE HASTINGS INSTRUMENTS

Nessie Coils for VDH and VDHT valves

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

IONIVAC Transmitter ITR 90

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Electromagnetic Digital Flow Switch

7 Lighting Technology

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Digital Flow Switch for Large Flow

IMPAC Infrared Thermometers

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Capacitance Level Measurement Electronic insert FEC 12

Photoelectrics Through-beam Type PA18C.T..., DC

Transcription:

04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital communication and control Direct operated valve Dynamic behaviour (high speed) A special feature of the Sentronic plus is its DaS software supplied for optimum adjustment over PC and viewing of setpoint and feedback signals. Other functions are valve diagnostics, parameter setting and maintenance. GENERAL Fluids Air or neutral gases, filtered at 50 µm, condensate-free, lubricated or unlubricated Ports G/ - G/4 - G/ - G Max. allowable pressure See table below Pressure range See table below Fluid temperature 0... C Ambient temperature 0... C Setpoint - analog 0-0 V (impedance 00 KΩ) 0-0 ma/4-0 ma (impedance 50 Ω) Hysteresis 0,5 % of span Linearity / pressure measurement ± 0,5 % of span Repeatability EXPLOSION SAFETY Safety code EC type examination certificate no.: CONSTRUCTION ± 0,5 % of span q II D Ex tb IIIC T5 C Db q II G Ex na IIC T4 Gc, 0 Ta +50 C IBExU07ATEX7 Direct operated poppet valve Body See table below Internal parts Stainless steel and brass Seals FPM and NBR ELECTRICAL CHARACTERISTICS nominal diameter max. power max. current stabilised voltage * DN (W) (ma) 500 6 4 V = 4 V = 4 ) 000 ) +/-0% 4 400 0 44 00 * Max. ripple: 0 % SPECIFICATIONS pipe size orifice size (mm) insulation class F degree of protection IP65 Digital Control electrical connection 5-pin M connector or 7-pin DIN connector coefficient Kv (Nm /h) G / 0, 0 G /4 6 0, 700 G /,0 400 G 0 4,0 50 CATALOGUE NUMBER 6 4 5 9 B A S I D P P B: CONTROL PANEL D = M with display - non-explosionproof E = M without display - explosionproof (ATEX) F = DIN connector, 7-pin, with display - non-explosionproof G = DIN connector, 7-pin without display - non-explosionproof A: VERSION (ports), body 0 = DN6 (G /4), Alu 7 = DN (G /), Brass = DN (G /), Alu = DN6 (G /4), Brass = DN0 (G ), Alu 9 = DN (NPT /), Brass 4 = DN6 (NPT /4"), Alu A = DN6 (NPT /4"), Brass 5 = DN (NPT /"), Alu C = DN6 (G /4), St. steel 6 = DN0 (NPT "), Alu H = DN6 (G /4), Brass ) S: SETPOINT 0 = 0... 0 Volt = 0... 0 ma = 4... 0 ma Notes: ) Only for DN and DN 6 ) Only for DN6, brass /, A 44 W Other versions available on request. I: FEEDBACK = Feedback output 0... 0 Volt = Feedback output 0... 0 ma = Feedback output 4... 0 ma PP: PRESSURE RANGE Relative pressure 40 = 0-00 mbar 50 = 0-500 mbar = 0 - bar 0 = 0 - bar 0 = 0 - bar 05 = 0-5 bar 06 = 0-6 bar 0 = 0-0 bar = 0 - bar 6 = 0-6 bar ) 0 = 0-0 bar ) H = 0-0 bar ) 5H = 0-50 bar ) flow at 6 bar (l/min - ANR) / Series 64 Max. allowable pressure (bar) Vacuum (relative) V = 0... - bar shut-off valve (vacuum at port ) V = 0... - bar bypass version V = 0... - bar shut-off valve 4 (vacuum at port ) 40 D: DIGITAL OUTPUT = Pressure switch output PNP ± 5 % Proportional Valves - 9

x G/ - 4 x G/4 - x G/ - PROPORTIONAL VALVES Sentronic plus WITH M CONNECTION SERIES 64 G / Weight: 0,700 kg M connector; 5 pins 95, 0,5 x M4-0 5 6,6 0 5 5 5 4 9 75 5 G /4 Weight:,000 kg aluminium /,700 kg brass M connector; 5 pins 4,7 05, x Ø 4, 6 55,, 0 0 6 54 6 G / M connector; 5 pins Weight:,00 kg,5 5 7 0 4,5 6 9, 6,5 5 5 4 5 5 57,5 70 x Ø 5 40 04GB-06/R0 0 - Proportional Valves

x G - 4 PROPORTIONAL VALVES Sentronic plus WITH M CONNECTION SERIES 64 G Weight:,550 kg M connector; 5 pins, 4,7 x Ø 7 0 5,5 4 00 0,74 6 6 5 79 96 CONNECTOR PINNING / CABLE WIRING 04GB-06/R0 4 5 Pin Description 5-wire cable ( m) 6-wire cable (5 m, 0 m) 4 V voltage supply brown brown Analog setpoint input white white Supply ground blue green Analog ground - yellow 4 Analog output (Feedback) black pink 5 Digital output (Pressure switch) grey grey Body EMC screen shield shield ) A 6-wire cable with separate analog ground is used for cable lengths over m to set off the voltage drop for the setpoint. Proportional Valves -

PROPORTIONAL VALVES Sentronic plus WITH 7-PIN DIN-CONNECTOR SERIES 64 G / Weight: 0,700 kg max. x M4-0 5 0.5 0 xg/ - 6.6 5 5 9 5 4 4. 75 G /4 Weight:,000 kg aluminium /,700 kg brass max.75 - Proportional Valves xg/4-6 05. 55. 0 6 4. 4 54 5 6,06 0 xø4,..0 04GB-06/R0

PROPORTIONAL VALVES Sentronic plus WITH 7-PIN DIN-CONNECTOR SERIES 64 G / Weight:,00 kg max.5 x Ø 5 xg/ 4 6 6.5 4.5 40 5 5 7 4. 57.5 70 0 G Weight:,550 kg 04GB-06/R0 max.97 6 6.5 xg - 00 4 4. 79 96 5 0 0,7 x Ø 7 Proportional Valves -

PROPORTIONAL VALVES Sentronic plus SERIES 64 ACCESSORIES description catalogue number Straight M female connector, 5 pins, with screw terminals 0056 Right-angle M female connector, 5 pins, with screw terminals 0075 Supply cable m; 5x0,5 mm ; straight connector 0076 Supply cable m; 5x0,5 mm ; right-angle connector 0077 Supply cable 5 m; 6x0,50 mm ; straight connector 007 Supply cable 5 m; 6x0,50 mm ; right-angle connector 0079 Supply cable 0 m; 6x0,50 mm ; straight connector 0070 Supply cable 0 m; 6x0,50 mm ; right-angle connector 007 RS cable converter; m cable with 9-pin Sub-D (plug connector) 007 RS cable converter; m cable with 9-pin Sub-D (screw connector) 00970 DaS Light: Data Acquisition Software for Sentronic plus - basic parameters - CD-ROM 99000 DaS Expert: Data Acquisition Software for Sentronic plus - full parameters - CD-ROM 9900 4 - Proportional Valves 04GB-06/R0