Self--powered Time Counter

Similar documents
Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Self-powered Totalizer

Self-powered Totalizer New H7E

Multifunction Digital Timer

Solid-State Digital Timer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

02/11/2015

Absolute Rotary Encoder E6CP

Photoelectric Sensors E3F2

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Model Number Structure

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Cylindrical Photoelectric Sensor CY-100 SERIES

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Features. Digital Time Switch H5S. Easier and More Convenient to Use

02/11/2015

Frequency/Rate Meter

Indoor Linear 80W Driver SI-C215280N2KR

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Solution Selection Guide

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Type Contact form Model

Digital Time Switch H5S. Features. Easier and More Convenient to Use

H8GN. Model Number Structure. Ordering Information. Preset Counter/Timer (48 24) Model Number Legend. List of Models

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Photoelectrics Through-beam Type PA18C.T..., DC

K3NX Process Meter OPERATION MANUAL

Input type NPN/Voltage pulse PNP 240 VAC

Preset Counter & Timer combined in one body in "G" format FIRST Double display: PV & SV, in "G" format FIRST Serial communication in "G" format FIRST

GC61 Digital Pressure Gauge. Operation Manual

Pulse Counters, electronic

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Assembly. Front view. LEDs. Parametrization interface. Power Bus

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

GC30 Digital Differential Pressure Gauge Operation Manual

Installation Guide VL-MV10. Model No.

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Electrical connection

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

LH1D Series Surface Mount Indicators

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Ordering details. Approval. Classification

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Operating instructions Electronic preset counter Type series 717

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Process Transmitter RMA 422

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Datasheet - SRB301LC 24VAC/DC

LONWORKS Fibre Optic Router

Multifunction devices

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

Hour Meters / Timers, electronic

SA1J-F: Full Color Fiber Optic Sensors

USER S MANUAL. FX2N-8AD Analog input block

ODW-621. RS-232 Point-to-point applications

Proportional output thumbwheels - sprung to centre

CM1-AD08V 0~5V, 1~5V, -10~10V, 0~10V An input signal is converted to a digital value from 0 to or from 8000 to 8000.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

Model Number Structure

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

Product Data Sheet 4656 ZW

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Operating Instructions

Flexible Counter Series in DIN size 24 x 48 mm

Transcription:

Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to 3999d23.9h Key-protect switch to prevent front resetting Selectable time range: 999999.9h or 3999d23.9h and 999h59m59s or 9999h59.9m NEMA 4/IP66 front Replaceable battery New black case Ordering Information TIME COUNTERS Count Display Time range 999999.9h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) PNP/NPN universal DC 7-segment LCD -NV-BH -NV1-BH voltage with backlight 7-segment LCD -NV-B -NV1-B AC/DC multi-voltage 7-segment LCD -NFV-B -NFV1-B No-voltage 7-segment LCD -N-B -N1-B MODEL NUMBER LEGEND - N - 1 2 3 4 1. Count Input None: No-voltage V: PNP/NPN universal DC voltage FV: AC/DC multi-voltage 2. Time Range None: 999999.9h/3999d23.9h 1: 999h59m59s/9999h59.9m 3. Case Color B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight

ACCESSORIES (ORDER SEPARATELY) Item Replacement Battery Wire-wrap Terminal (set of two terminals) Part number Y92S-36 Y92S-37 Flush Mounting Adapter 26 mm 45 mm Y92F-75 Specifications GENERAL Item -NV-B -NV-BH UP type Flush mounting 24.8 mm 48.8 mm Y92F-77B -NFV-B -N-B -NV1-B -NV1-BH -NFV1-B Operating mode Mounting method External connections Screw terminals, optioinal wire--wrap terminals (See Note 3.) External/Manual reset Display 7-segment LCD with or without backlight (character height: 8.6 mm) (See Note 1.) Number of digits 7 Time range 0.0h to 999999.9h or 0.0h to 3999d23.9h (switchable with switch) Count PNP/NPN universal DC voltage Black AC/DC multi-voltage No-voltage 0s to 999h59m59s or 0.0m to 9999h59.9m (switchable with switch) PNP/NPN universal DC voltage AC/DC multi-voltage Case color Attachment Waterproof packing, flush mounting bracket, time unit labels (See Note 2.) Approved standard UL508, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category ) Conforms to VDE0106/P100 -N1-B No-voltage Note: 1. Only PNP/NPN universal DC voltage models (-H models) are available with a backlight. 2. -hours, -d-h, -h-m, and -h-m-s labels are included. 3. wire--wrap terminals (Y925--37) can be ordered separately RATINGS Item -NV-B, -NV-BH -NFV-B -N-B Supply voltage Backlight model: 24 VDC (for Not required (powered by battery) backlight) No-backlight model: Not required (powered by battery) Count High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kω) 10 kω max. Minimum pulse width system Terminal screw tightening torque 2 High (logic) level: 24 to 240 VAC/ VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/ VDC, 50/60 Hz No voltage Maximum short-circuit impedance: 10 kω max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kω min. 1s External reset and manual reset: Minimum signal width of 20 ms 0.98 N mmax. Ambient temperature Operating: --10 C to55 C (with no condensation or icing) Storage: --25 C to65 C (with no condensation or icing) Ambient humidity Operating: 25% to 85% No voltage Maximum short-circuit impedance: Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kω min.

CHARACTERISTICS Item Time accuracy Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Battery life -NV- -NV-H ±100 ppm (25 C) 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed, and between the backlight power supply and count terminals/reset terminals for backlight models 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed and between the backlight power supply and count terminals/reset terminals for backlight models 4.5 kv between current-carrying terminal and exposed Between terminals: ±600 V in normal mode, ±1.5 kv in command mode For backlight power supply (backlight model): ±480 V in normal mode, ±1.5 kv in command mode ±8 kv (malfunction) -NFV- 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed and between count terminals and reset terminals 3,700 VAC, 50/60 Hz for 1 min between count terminals and exposed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between count terminals and reset terminals 4.5 kv between current-carrying terminal and exposed 3 kv between terminals and reset terminals Between count terminals: ±1.5 kv in normal mode, ±1.5 kv in command mode Between reset terminals: ±500 V in normal mode, ±1.5 kv in command mode -N- Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Malfunction: 200 m/s 2 {approx. 20G} 3 times each in 6 directions Destruction: 300 m/s 2 {approx. 30G} 3 times each in 6 directions 10 years min. with continuous at 25 C (lithium battery) EMC (EMI) EN50081-1 Emission Enclosure: EN55022 class B (EMS) EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204: 20 V/m (900 MHz ± 5MHz)(level3) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3) Immunity Burst: EN61000-4-4: 2-kV power line (level 3) 2-kV I/O signal line (level 4) Enclosure rating Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 Weight (see note) Non-backlight model: Approx. 60 g Backlight model: Approx. 65 g Approx. 60 g Approx. 60 g 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed 4.5 kv between current-carrying terminal and exposed ±500 V in normal mode, ±1.5 kv in command mode Note: Weight includes waterproof packing and flush mounting bracket. 3

Nomenclature TIME COUNTER Front view Key the count value. Not operable under key-protect. Time-range switch If the switch setting is changed, press the Key on the front panel. Key-protect Switch Setting (see note) Key-protect Front panel Setting (see note) -N- Time range -N1- Bottom view OFF (default setting) Front panel 0.0h to 3999d23.9h (default setting) 0s to 999h59m59s (default setting) ON Terminal block 0.0h to 999999.9h 0.0m to 9999h59.9m Terminal block Note: Perform switch setting before mounting to a control panel. Operation OPERATING MODES Time Counter Incrementing Operation (Up) Timer Internal clock timer value Full-scale (Full-scale --0.1 (1)) Timer display values 4

Dimensions Unit: mm (inch) -N 44.8 (1.76) Panel Cutout Separate mounting 60 min. 24 (0.94) 22 (0.87) 48 (1.89) 48.5 (1.91) 60 min. 45 +0.5 0 22.2 +0.5 0 Dimensions with Flush Mounting Bracket Joint mounting (48 Units - 2.5) +10 0 44.8 Waterproofing is not possible for joint mounting 22.2 +0.5 0 35 (1.38) 24 37 (1.46) When mounting, insert the Counter into the cutout. Insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. When several Counters are installed, ensure that the ambient temperature will not exceed specifications. The appropriate thickness of the panel is1to5mm. Installation TERMINAL ARRANGEMENT Bottom view: View of the Time Counter rotated horizontally 180 Backlight Model Non-backlight Model Backlight 24 VDC Timer Timer 5

Connections PNP/NPN UNIVERSAL DC VOLTAGE INPUT MODEL WITH BACKLIGHT 1. Contact Input (Input by a Contact) 2. Solid-state Input Backlight 24 VDC Open collector of a PNP transistor Backlight 24 VDC Open collector of a PNP transistor Input Input or Open collector of an NPN transistor or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 ( circuit and reset circuit) are functionally isolated. 2. Select transistors according to the following: Dielectric strength of the collector 50 V Leakage current < 1 µa 6

PNP/NPN UNIVERSAL DC VOLTAGE INPUT MODEL WITHOUT BACKLIGHT 1. Contact Input (Input by a Contact) NO-VOLTAGE INPUT MODEL 1. Contact Input (Input by a Contact) Input Input Terminals 2 and 4 are internally connected. 2. Solid-state Input Open collector of a PNP transistor Input Open collector of a PNP transistor Note: Use s and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is as small as approx. 10 µa. OMRON s G3TA-IA/ID is recommended as the SSR. 2. Solid-state Input (Open Collector Input of an NPN Transistor) Open collector of an NPN transistor Input Open collector of an NPN transistor or Open collector of an NPN transistor or Open collector of an NPN transistor Terminals 2 and 4 are internally connected. Note: 1. Terminals 2 and 4 ( circuit and reset circuit) are functionally isolated. 2. Select transistors according to the following: Dielectric strength of the collector 50 V Leakage current < 1 µa AC/DC MULTI-VOLTAGE INPUT MODEL Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is as small as approx. 10 µa, allowing easy connection. 2. Select transistors according to the following: Dielectric strength of the collector 50 V Leakage current < 1 µa Input or Open collector of an NPN transistor 7

Accessories (Order Separately) An is supplied with a mounting bracket and nut. In addition, the Flush Mounting Adapters shown here allow the H7ER to be fitted to existing panel cutouts. Y92F-75 FLUSH MOUNTING ADAPTER FOR 26 45 RECTANGULAR CUTOUT Must be used with mounting bracket supplied with the Counter Two 3.5 dia. mounting holes Panel Cutout Two M3 31 24.2 22.2 (1.22) 26 (1.02) 26 45.2 48.2 63 72 (2.83) 4 45 63 (2.48) Y92F-77B FLUSH MOUNTING ADAPTER FOR 24.8 48.8 RECTANGULAR CUTOUT Must be used with mounting bracket supplied with the Counter Panel cutout 28.8 (1.13) 24.2 22.2 24.8 (0.98) 45.2 48.2 53.8 (2.12) 4 48.8 (1.92) Y92S-37 Wire-Wrap Terminal (Set of Two Terminals) 44.8 (1.76) Wire-wrap terminal (1 1 mm) 24 (0.94) 22 48 (1.89) 2 5 48.5 65.6 17.1 (2.58) The wire--wrap terminals have a cross sectional dimension of 1x1 mm. Select one of three guages of wire from the table at right. Also listed in the table is the appropriate wiring hardware Wire Bit Sleeve Wrapped state AWG22 2-A 2-B Normal AWG24 1-A 1-B Normal AWG26 1-B 1-B Normal 8

Y92S-36 REPLACEMENT (LITHIUM) BATTERY (3 V) 24.5 dia. 7.7 Precautions! WARNING This product has a built-in lithium battery. Do not short-circuit the + and -- terminals, charge, disassemble, deform, or expose the battery to fire. The battery may explode (break), catch fire, or cause liquid leakage.! Caution Do not use any battery other than the specified one (Y92S-36). Using another battery may cause liquid leakage or breakage, resulting in malfunction or injury. BEFORE USE An insulation sheet has been inserted to maintain the quality of the Totalizer in the event of a long period without use. Be sure to remove this sheet before attempting to use the product. Remove the insulation sheet and press the Key on the front panel of the Counter. (With the -N,-NV(-H),-NV1(-H), models, 0 or 0.0 will be displayed after 1 s.) Insulation Sheet! Caution If a voltage other than the rated one is applied, internal elements may be damaged. Do not use the Counter in the following places: Locations subject to direct sunlight. Locations subject to corrosive gases. Locations subject to dust. Key Switch settings on the Counter must be performed before mounting it to a control panel. Do not use the Counter in locations subject to: Severe changes in temperature. Condensation as the result of high temperatures. MOUNTING PRECAUTIONS FOR FLUSH MOUNTING Although the operating section is watertight (conforming to NEMA4, IP66), rubber packing is provided to avoid water leakage through the gap between the Counter and panel cutout. Unless this rubber packing is tightly squeezed on, water may permeate inside the panel. For this reason, be sure to tighten the screws for fixing the Flush Mounting Bracket. Screw for the Flush Mounting Bracket The wider side must face the panel. Adapter Adapter screw section 0.5to1mm Panel Tighten the screw until the distance is within the range shown above. 9

RESET INPUT AND COUNT INPUT The operates using a Battery. If the is connected to a device that has +V and OUT terminals that are connected with a diode as shown in the circuit diagram, the circuit indicated by the arrow 1 or 2 will be formed when the device is turned OFF. As a result, the may be reset or count by one. Such devices should not be connected to the H7ER. Internal circuit Count or reset INPUT AND POWER SUPPLY Do not apply voltage on the Counter if the Counter is a model that operates with no-voltage, or the internal circuit of the Counter may be damaged. Do not connect any single signal in parallel to Counter models operating with no-voltage and those operating with voltage, to avoid malfunction. When connecting a sensor to the Counter that operates with no-voltage, make sure that the sensor has open collector output. Sensor If an excessive voltage is applied to the count or reset terminals, the internal elements may be damaged. Ensure that the following voltages are not exceeded: PNP/NPN universal voltage model: 30 VDC AC/DC voltage model: At count : 240 VAC (peak voltage: 338V) 240 VDC At reset : 3 VDC (no-voltage ) No-voltage model: 3 VDC Do not remove the outer case when voltage is being applied to the power supply terminals or to the terminals. The for the H7E-NFV- is a high-impedance circuit so influence from an induced voltage may result in malfunction. When the signal wiring is longer than 10 m (stray capacitance of 120 pf/m, at room temperature), a CR filter or a bleeder resistor should be connected. The operation of the Counter may be affected if the line voltage of the power supply exceeds 500 pf (about 10 m, with parallel wires of 2 x 2 mm). Keep all wires as short as possible. When using shielded wire, stray capacitance may occur. When connecting an open collector from a transistor to the Counter that operates with no-voltage, make sure that the leakage current of the transistor is 5 µa maximum. When connecting count from an SSR to the Counter that operates with AC/DC voltage, use OMRON s G3TA-IA or G3TA-ID SSR. Otherwise, make sure that the leakage current of the SSR is 0.1 ma maximum or connect a bleeder resistor in parallel to the circuit of the Counter. COUNT INPUT OR RESET INPUT TO MORE THAN ONE COUNTER AT ATIME PNP/NPN Universal DC Voltage Input or or Leakage current: 0.1 ma max. or *Bleeder resistor The voltage between terminals 1 and 2 must be 1.5 V maximum when the SSR is OFF. or BACKLIGHT POWER SUPPLY To reduce variation in the brightness of the backlight when using more than one with a backlight, use the same power supply for all the backlights. or Note: H ( ON) level must be 4.5 V minimum. 4.7 (kω)/n + V H= 4.7 (kω)/n + R No-voltage Input Note: 1. The leakage current of the transistor used for must be less than 1 µa. 2. The forward voltage of the diode must be as low as possible (i.e., 0.1 V maximum with an I F of 20 µa) so the voltage between terminals 3 and 4 will be 0.5 V when the reset is ON. or When connecting the DC power supply for the backlights, be sure to connect the polarities correctly. INPUT VERIFICATION WITH THE TIME COUNTER The decimal point of the LCD blinks every other second while an signal is being applied. If the decimal point is not blinking, the signal is not being received correctly. Check the signal connections. 10

UNIT LABEL FOR TIME COUNTER AND TACHOMETER A unit label has been packed with the Counter. Use in accordance with the application. BATTERY REPLACEMENT Remove the wiring when replacing the Battery. Do not come in contact with any item to which high voltage is being applied. Doing so may result in electric shock. Before changing the Battery, be sure that you are not carrying any static electric charge. EN/IEC STANDARDS The counter, reset, and backlight power supply terminals of the no-voltage or PNP/NPN universal DC voltage models (H7E-N,-N1, H7E-NV(-H),-NV1(-H)) are not isolated. A SELV power supply conforming to Appendix H of IEC61010-1 should be used for the counter, reset and backlight power supply terminals. A SELV power supply is a power supply for which the and output have double or reinforced insulation, and for which the output voltage is 30 Vrems with 42.4 V peak or 60 VDC max. (Only the H7E-NV-H has a backlight.) The terminals for counter and reset for AC/DC multi-voltage models have basic insulation. Connect the reset terminals to a device that does not have exposed current-carrying parts and has basic insulation for 240 VAC. Procedure for replacing the Battery (refer to the diagrams below): 1. Using the tool, pry open the lift-tab on the case. (1) 2. Pull the body out of its outer case. (2) 3. Lift the Battery up by the edge and remove it. (3) When removing the Battery, do not come in contact with the display area or any internal parts. 4. Wipe the back of the new Battery before inserting it. 5. Ensure that the + and -- terminals are correctly oriented. 6. After replacing the Battery, re-insert the body into its case. (4) Check that the case is securely held in by the lift-tab. 7. Press the Key before use (not necessary for -N,-NV,-NV1). (5) When the internal Battery nears expiration, the display may flicker. (1) Tool (2) (1) (3) (4) (5) 11

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OneEastCommerceDrive Schaumburg, IL 60173 1-800-55-OMRON OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. M064C-E3-1 8/99 Specifications subject to change without notice. Printed in U.S.A.