Certificate of Calibration

Similar documents
ISO-TECH IPM3005 Flexible AC Power Quality Tester Instruction Manual

User Manual Power and Harmonics Analyzer Model PQ3350

User Manual. Power and Harmonics Analyzer Model PQ3350

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Calibration Information

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

True RMS AC/DC Mini Clamp Meter

multi-function meters

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

SAFETY TERMS AND SYMBOLS

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ProcessMeter. Product Overview

3M Sensored Termination (15 kv) QX-T15I-vi1-E

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

ELECTRONIC HARMONICS METER RELAY

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Manual PCE-830 power anlayser

Fluke 279 FC True-rms Thermal Multimeter

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

Kuhnke Technical Data. Contact Details

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

APQ Series Type C Power Factor Correction Banks

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Operating Manual RISH OPTIMA VAF

Snap ShotTM User Manual

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

ScopeMeter 190 Series Specifications

EA350. Generator Automatic Voltage Regulator Operation Manual

Model P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Additional Instructions for the Arlec Energy Cost Meter PC222

n Transient feature simulates voltage variations, brownouts and transient voltage conditions

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

Tablet Oscilloscope Quick Guide

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

PAM-1840 Preamplifier Operation Manual

28 II Ex Digital Multimeter

Tube Rotator. User Guide. Version 1.2

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

OPERATOR S MANUAL TRUCHECK & TRUCHECK PLUS. Part Number Issue 1 Original Instructions (English)

ELECTRONIC MULTI METER

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

LED control gear Compact fixed output

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Calibration Manual. Remote Display True-rms Clamp Meter

User Manual Digital Stroboscope

CFM/CMM Thermo Anemometer

Operating instructions Electronic preset counter Type series 717

# Voltage Performance Monitor Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.

Solid-State Digital Timer

KRF EMC Filters Installation, Operation and Maintenance Manual

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

KHT 1000C HV-Probe Calibrator. Instruction Manual

FAULT MAPPER PRO GRAPHICAL TDR CA7027. User Manual

Utility Amplifier GA6A Model

4 Wiring Brochure Wiring and installation of specific control

Instructions. P MHz 1X/10X Passive Probe

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

llen-bradley 194R-HM4-NFPA3

1 Power Protection and Conditioning

Agilent 5345A Universal Counter, 500 MHz

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Indoor Linear 80W Driver SI-C215280N2KR

Model Number Structure

SM-10 SAT Level Meter User s Manual

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Advanced Digital Melting Point Apparatus

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

NS-3 RF Noise Source Operation Manual

MULTIS L72. Operating instructions

Spectra Batten (Order code: LEDJ95)

TABLE OF CONTENTS. Instructions:

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

ZoneTouch V2 Zone Control System User Manual

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

POWER FACTOR REGULATOR

By CHANNEL VISION. Flush Mount Amplifier A0350

LED Driver Compact fixed output

LED Driver Linear / area fixed output

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Operating Instructions

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

AS09..S 3-pole Contactors - Spring Terminals

LED Driver Compact dimming

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

LED Driver Compact fixed output

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Transcription:

Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Plot No. EL-60, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai - 400710 (INDIA) Tel : 0091-22-27673311-16, 27673300 (Board) Fax : 0091-22-27673310, 27673330 E-mail : sales@mecoinst.com Web : www.mecoinst.com SR. NO. : CHECKED BY : DATE : MODEL NO. : AC CLAMP-ON POWER AND HARMONICS TESTER MODEL : PHT4545 USER MANUAL 2 EN 61010-2-032 CAT III 600V Pollution Degree 2 Definition of Symbols : Caution : Refer to Accompanying Documents Caution : Risk of Electric Shock Double Insulation Over-voltage Category I (CAT I) : Equipment for connection to circuits in which measurps are taken to limit the transient over-voltages to an appropriate low level. Over-voltage Category II (CAT II) : Energy-consuming equipment to be supplied from the fixed installation. Over-voltage Category III (CAT III) : Equipment in fixed installations. WARNING : If the clamp meter is used in a manner Not specified by the manufacturer, the protection Provided by the clamp meter may be impaired. TABLE OF CONTENTS I. FEATURES... 2 II. PANEL DESCRIPTION... 3 III. OPERATING INSTRUCTIONS... 6 lll.1. Measurenment of ACA... 6 lll.1.1. True RMS value of AC Current... 7 lll.1.2. HOLD, MAX, MIN and.peakofac Current... 7 lll.1.3. Harmonics of AC Current in Magnitude (V)... 8 lll.1.4. Harmonics ofac Current in Percentage (%)... 8 lll.1.5. Total Harmonic Distortion (% THD-F)... 9 lll.1.6. Crest Factor(C.F.)... 10 lll.2. Measurement of AC Voltage... 11 lll.2.1. True RMS value of AC Voltage... 11 lll.2.3. HOLD, MAX, MIN and PEAK value of AC Voltage 12 lll.2.3. Harmonics of AC Voltage in Magnitude (V)... 13 lll.2.4. Harmonics of AC Voltage in Percentage (%)... 14 lll.2.5. Total Harmonics Distortion (% THD-F)... 14 lll.2.6. Crest Factor (C.F.)... 15 lll.3. Measurement of Single Phase AC Power Quality... 16 lll.3.1. Single Phase AC Watt and Power Factor (PF)... 17 lll.3.2. Apparent Power (VA, KVA) and Reactive Power (VAR, KVAR)... 17 lll.3.3. Phase Angle (u)... 18 lll.3.4. Horse Power (H.P)... 18 lll.3.5. Energy (WH, or KWH)... 19 lll.4 Measurement ot the Balanced 3 Phase AC Power Quality... 20 lll.5 Measurement of the Balanced 3 Phase Sequence lll.6 Measurement of Resistance and Continuity with Beeper... 23 IV. SET THE CT RATIO... 24 V. DISABLE AUTO-POWER-OFF... 24 Vl. SPECIFICATIONS (23 0 C±5 0 C)... 25 Vll. BATTERY REPLACEMENT... 30 Vlll. MAINTENANCE & CLEANING... 31 3

1. FEATURES 2. PANEL DESCRIPTION a. Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power. b. Power factor (PF), phase angle (u), and energy (WH, KWH). c. Non-interrupted AC current harmonic analysis. d. 1 to 99 th order of harmonics at 2.0% basic accuracy. e. Total harmonic distortion (%THD-F) and crest factor (CF). f. True RMS measurement of V and A at 0.5% basic accuracy. g. Fast peak function (39ms for 50 Hz, 33ms for 60Hz). h. Resistance and Continuity with Beeper Measurement of balanced 3f power. j. Measurement of balanced 3f sequence. k. Programmable CT ratio from 1 to 250. l. Max, Min and data hold functions. m. Active power in H.P. n. Auto power off function in 30 minutes. 4 5 1. Transformer Jaw Assembly This is used to pick up current signal. To measure AC current or Power/Watt, the jaw must enclose conductor completely. 2. Transformer Trigger Press the trigger to open the jaw. 3. Rotary Switch This is used to turn the power on and select measurement of current, voltage or power. 4. MAX/MIN/HOLD/PEAK In the measurement of A, or V, press this button to perform function of MAXIMUM, MINIMUM, HOLD or PEAK. If this button is hold when turning on power, the tester can perform measurement of phase sequence instead of phase angle in the balanced 3f power system. 5. s 3f Button This button is used to increment order of harmonics or CT ratio. When the rotary switch is set at W position, press this button to select measurement of balanced 3f power instead of single-phase power. 6. FUNC Button In the measurement of A, or V, press this button to select function of harmonics, THD-F, or CF. In the measurement of W with PF, press this button to select function of VA, VAR, phase angle, HP, or energy (KWH). 7. LCD This is a 4+4 digit Liquid Crystal Display. Function symbols, units, sign, decimal points, low battery symbols, max, min symbols, peak and harmonic symbols are included. 8. Symbols Those are symbols of selected functions such as, Hamonic, PEAK, MAX, MIN or HOLD. 9. Primary Digits The primary digits display the main function such as voltage, current, wattage, and apparent power. 10. Secondary Digits These digits display secondary function of measurement, such as power factor, reactive power, and the order of harmonics. 11. Symbols of Units These are unit symbols for Current, voltage, and power. The nominal frequency (50 or 60 Hz) of measurement is displayed above these unit symbols. 12. V Input Terminal This terminal is used as input for voltage and power measurements. 13. COM Terminal This terminal is used as common reference input. 14. Frequency Select Function Press this button to select nominal frequency (50 or 60Hz) 15. t button It is used to decrement the order of hamonics or CT ratio. Holding this button when turning on the power will fix the measuring frequency at 50 or 60 Hz 16. Symbol of Current Transformer (CT) If the CT ratio is not 1, this symbol will be displayed in LCD. 6 7

3. OPERATING INSTRUCTIONS 3.1 Measurement of ACA NOTE: 1. Set the rotary switch at the A position. 2. The unit will measure and display signal frequency. If users wish to fixed the frquency 50 or 60, users can hold the t button when turning on the power. 3. If the peak value of the input AC current is greater than the maximum value of the range, then symbol of OL will be displayed. NOTE : Whenever the rotary switch is set at new position, the CT ratio will be displayed first. If the CT ratio is not 1, a symbol " " will be shown in the LCD display for the measurment of A. The reading of current shown in LCD is equal to the true RMS value measured by the tester multiplied by CT ratio (A LCD = A RMS x CT). 3. 1.1. True RMS value of AC Current a. Set the rotary switch at A Then select the correct frequency conductor to be c. Read the measured value from the LCD display. 3. 1.2. HOLD, MAX, MIN and PEAK of AC Current. a. Set the rotary switch at A. Then select the correct frequency b. Press the trigger to open the jaw and fully endose the conductor to be c. The measured value from the LCD display. If the HQLD button is pressed, the symbol of HOLD, MAX, MIN or PEAK will be shown in LCD alternatively. And the value of the HOLD, MAX, MIN or PEAK function will be displayed in LCD alternatively. d. To return to the display of current measurement, hold the HOLD button for more than 2 seconds. NOTE : The PEAK function displays the maximum value of the input waveform. The sampling time for the PEAK function is WARNING : Make sure that all the test leads are disconnected 39ms (50Hz) or 33ms (60Hz). The HOLD, MAX, or MIN function from the meter's terminals for current measurement. displays the true RMS value. 8 9 3. 1.3. Harmonics of AC Current in Magnitude d. Press the s or t button to increment or decrement the order of harmonics in the upper row digits. The number will roll over when the maximum (99) or minimum (1) is reached. 3. 1.5. Total Harmonic Distortion (% THD-F) a. Set the rotary switch at A. Then select the conect frequency conductor to be c. Press the FUNC button once. The symbols of Harmonic and NO. will be shown in LCD. The n-th order (1 to 99) will be shown in the upper row digits. d. Press the s or t button to increment or decrement the order of harmonics in the upper row digits. The number will roll over when the maximum (99) or minimum (1) is reached. 3. 1.4. Harmonics of AC Current in Percentage (%) a. Set the rotary switch at A position. Then select the correct frequency by pressing the 50/60 Hz button, conductor to be c. Press the FUNC button twice. The symbols of Harmonic and NO. will be shown in LCD. The n-th order (1 to 99) will be shown in the upper row digits. a. Set the rotary switch at A. Then select the correct frequency conductor to be c. Press the FUNC button three times. The symbols of THD and % will be shown in LCD. The total harmonic distortion in percentage with respect to the fundamental frequency (50 or 60 Hz) will be measured and displayed. %THD-F = ( (V2 2 + V3 2 +... V49 2 + V50 2 ) / V1) * 100 Where, V1: magnitude at the 50 or 60 Hz V2: magnitude at the second harmonics... V50: magnitude at the 99-th harmonics. 10 11

3. 1.6. Crest Factor (C.F.) a. Set the rotary switch at A. Then select the correct frequency conductor to be c. Press the FUNC button four times. The symbols of C.F. will be shown in LCD. The crest factor (C.F.) will be measured and displayed. The crest factor (CF) is defined as following: C.F. = (peak value) / (RMS value) 3.2 Measurement of AC Voltage NOTE : 1. The unit will measure and display signal frequency. If users wish to fixed the frquency at 50 or 60, users can hold the t button when turning on the power. 2. If the peak value of the input AC voltage is greater than the maximum value of the range, then symbol of OL will be displayed. NOTE : Whenever the rotary switch is set at a new position, the CT ratio will be displayed first. If the CT ratio is not 1, a symbol of will be shown in the LCD display. WARNING : Maximum input for ACV is 600. Do not attempt to take any voltage measurement that exceeds the limits. Exceeding the limits could cause electrical shock and damage to the clamp meter. 12 13 3. 2.1. True RMS value of AC Voltage NOTE : The PEAK function displays the maximum value of the input wavefom.the sampling time for the PEAK function is 39ms (50Hz) or 33ms (60Hz). The HOLD, MAX, or MIN function displays the true RMS value. 3. 2.3. Harmonics of AC Voltage in Magnitude (V) c. Read the measured RMS value from the LCD display. 3. 2.2. HOLD, MAX, MIN and PEAK value of AC Voltage c. Press the FUNC button once. The symbols of Harmonic and NO will be shown in LCD. The n-th order (1 to 99) will be shown in the upper row digits. d. Press the s or t button to increment or decrement the order of harmonics in the upper row digits. The number will roll over when the maximum (99) or minimum (1) is reached. c. The measured value is displayed in the LCD display. If the HOLD button is pressed, the symbol of HOLD, MAX, MIN or PEAK will be shown in LCD alternatively. And the value of the HOLD, MAX, MIN or PEAK function will be displayed in LCD alternatively. d. To return to the display of current measurement, hold the 14 HOLD button for more than 2 seconds. 15

3. 2.4. Harmonics of AC Vollage in Percentage (%) c. Press the FUNC button twice. The symbols of "Hamonic" and "NO" will be shown in LCD. The n-th order (1 to 99) will be shown in the upper row digits. d. Press the s or t button to increment or decrement the order of harmonics in the upper row digits. The number will roll over when the maximum (99) or minimun (1) is reached. 3. 2.5. Total Harmonic Distortion (% THD-F) c. Press the FUNC button three times. The symbols of THD and % will be shown in LCD. The total harmonic distortion in percentage with respect to the fundamental frequency (50 or 60 Hz) will be measured and displayed. %THD-F=( (V2 2 +V3 2 +... +V49 2 +V50 2 )/V1) * 100 Where, V1: magnitude at the 50 or 60 Hz V2: magnitude at the second harmonics... V50: magnitude at the 50-th harmonics. 3. 2.6. Crest Factor (C.F.) a. Set the rotary switch at posilion V. Then select the correct c. Press the FUNC button four times. The symbols of C.F. will be shown in LCD. The crest factor (C.F.) will be measured and displayed. The crest factor (CF) is defined as following: C.F. (Crest Factor) = (Peak Value) / (RMS Value) prod s of the test leads in PARALLEL to the circuit to be 16 17 3. 3 Measurement of Single Phase AC Power Quality NOTE : 1. Set the rotary switch at the W position. 2. Select the correct fundamental frequency of current and voltage by pressing the 50/60 Hz button 3. If the peak value of the input AC current or AC voltage is greater than the maximum value of the range, then symbol of OL will be displayed. NOTE : Whenever the rotary switch is set at a new position, the CT ratio will be displayed first. If the CT ratio is not 1, a symbol of will be shown in the LCD display for the measurement of W. The reading of current shown in LCD is equal to the W, VA, and VAR values measured by the tester multiplied by CT ratio (W LCD = W x CT, VA LCD = VA x CT, VAR LCD = VAR x CT, WH LCD = WH x CT). 3. 3.1 Single Phase AC Watt and Power Factor (PF) with the load. b. Clamp on one of the wire to the load. The current should flow frcm the front of the tester to the side of the battery d. Read the values of W or KW and PF shown on LCD. The unit of watt is automatically scaled. 3. 3.2. Apparent Power (VA, KVA) and Reactive Power (VAR, KVAR) wilh the load. b. Clamp on one of the wire to the load. The current should flow from the front of the tester to the side of the battery d. The value of W, or KW and PF will be displayed in LCD. e. Press the FUNC button once to display VA or KVA and 18 VAR or KVAR. The unit is automatically scaled. 19

3. 3.3. Phase Angle (u) with the load. b. Clamp on one of the wire to the laad. The current should flow from the front of the tester to the side of the battery e. The value of W, or KW will be displayed in LCD. The unit of watt is automatically scaled. f. Press the FUNC button three times to display phase angle (u) from 180 0 to +180 0. NOTE : To display phase angle (u) from 0 to 360, hold the s button, then turn the power on. Once the tester is turned on in this way, the tester will display phase angle from 0 to 360 0 (when phase angle function is selected). 3. 3.4. Horse Power (H.P.) b. Clamp on one of the wire to the load. The current should flow from the front of the tester to the side of the battery d. The vaiue of W, or KW and PF will be displayed in LCD. The unit of watt is automatically scaled. e. Press the FUNC button four times to display power in the unit of HP. 3. 3.5. Energy (WH, or KWH) with the load. b. Clamp on one of the wire to the load. The current should flow from the front of the tester to the side of the battery d. The values of W, or KW and PF will be displayed in LCD. The unit of watt is automatically scaled. e. Press the FUNC button five times. A character of H is displayed in front of reading to indicate energy (WH or KWH). with the load. 20 21 3.4 Measurement of the Balanced 3 Phase AC Power Quality a. Connect the black test lead to the voltage L3, and connect the red test lead to L1. b. Clamp on one of the wire to L2. The cun ent should flow from the front of the tester to the side of the battery d. Press the s 3f button to select balanced 3f. Symbols of 3f3W, 3f4W and BAL will be shown in LCD. e. The value of W or KW and PF will be displayed in LCD. The unit of watt is automatically scaled. f. If the FUNC button is pressed again, the apparent power (VA) and reactive power (VAR) will be shown in LCD. g. To measure the phase angle and phase sequence, users can press the FUNC button again. h. If the FUNC button is pressed again, the true power in the unit of Horse Power (HP) will be shown in LCD. i. To measure the energy (WH), users can press the FUNC button again. The current energy (WH or KWH) will be shown in LCD. NOTE : Users can also obtain the measurements of VA, VAR, Phase Angle, phase sequence, HP, and energy (WH) for balanced 3f power system. The operations are the same as the measurements for the single-phase power system. NOTE : The reading of current shown in LCD is equal to the W, VA, and VAR value measured by the tester multiplied by CT ratio (W LCD = W x CT, VA LCD = VA x CT, VAR LCD = VAR x CT, WH LCD = WH x CT) 22 23

3.5 Measurement of the Balanced 3 Phase Sequence a. Set the rotary switch at the W position b. Connect the black test lead to the voltage L3, and connect the red test lead to L1. c. Clamp on to the wire of L2. The current should flow from the front of the tester to the side of the battery d. Press the s 3f button to select 3 phase power system. A symbol of 3f will be shown in LCD. e. Press the FUNC button to select phase angle function. The LCD will show L123 to indicate the clockwise sequence in the upper row digits of LCD. Or the LCD will show L132 to indicate counter clockwise sequence. 3.6 Measurement of Resistance and Continuity with Beeper 24 25 a. Set the rotary switch at V b. Insert the test leads into the input jack. c. Connect the test prods of the test leads to the two ends of the resistor or circuit to be d. Read the measured value from the LCD display. e. If the resistance is lower than 50 V, a beeping sound shall be heard. 4. SET THE CT RATlO To set the CT ratio, hold the FUNC button, and then turn the power on. A symbol of will be shown in LCD. The default value of CT is 1. To change the CT ratio, users can press the s or t button to increment or decrement the value by 1, Holding the s or t button will speed up the process of incrementing or decrementing. To exit the setting of CT ratio, press the FUNC button. 6. SPECIFICATIONS(23 0 C±5 0 C) AC Watt (50 or 60 Hz, PF 0.5 to 1. CT = 1, Voltage > AC 5V, Current > AC 5A, and continuous waveform) of Readings 1 >20V & >20A <20V or <20A 10.0-999.9 W 0.1W ±2% ± 20dgts ±2% ± 40dgts 1.000-9.999 KW 0.001 KW ±2% ± 20dgts ±2% ± 40dgts 10.00 99.99 KW 0.01 KW ±2% ± 20dgts ±2% ± 40dgts 100.0-999.9 KW 0.1 KW ±2% ± 20dgts ±2% ± 40dgts 1000-9999 KW 1 KW ±2% ± 20dgts ±2% ± 40dgts 1 For CTf1, the accuracy in percentage is the same (±2%). But the additional wattage should be multiplied by the CT ratio. For example, ±2.0W becomes ±2.0W * CT ratio ±4.0W becomes ±4.0W * CT ratio 5. DISABLE AUTO-POWER-OFF The tester has an auto-power-off function. The tester will turn the power off after power is turned on for 30 minutes. To disable the auto power off function, hold the FUNC button for more than 2 seconds. A beep sound will be heard to indicate that the auto power off function is disabled. 26 27

AC Apparent Power (VA, from 0.000VA to 9999 KVA) of Readings 2 >20V & >20A <20V or <20A 10.0-999.9 VA 0.1VA ±2% ± 20dgts ±2% ± 40dgts 1.000-9.999 KVA 0.001 KVA ±2% ± 20dgts ±2% ± 40dgts 10.00-99.99 KVA 0.01 KVA ±2% ± 20dgts ±2% ± 40dgts 100.0-999.9 KVA 0.1 KVA ±2% ± 20dgts ±2% ± 40dgts 1000-9999 KVA 1 KVA ±2% ± 20dgts ±2% ± 40dgts 2 For CTf1, the accuracy in percentage is the same (±2%). But the additional VA should be multiplied by the CT ratio. For example, ±2.0VA becomes ±2.0VA * CT ratio ±4.0VA becomes ±4.0VA * CT ratio AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR) of Readings 3 >20V & >20A <20V or <20A 10.0-999.9 VAR 0.1VAR ±2% ± 30dgts ±3% ± 40dgts 1.000-9.999 KVAR 0.001 KVAR ±2% ± 30dgts ±3% ± 40dgts 10.00-99.99 KVAR 0.01 KVAR ±2% ± 30dgts ±3% ± 40dgts 100.0-999.9 KVAR 0.1 KVAR ±2% ± 30dgts ±3% ± 40dgts 1000-9999 KVAR 1 KVAR ±2% ± 30dgts ±3% ± 40dgts 3 For CTf1, the accuracy in percentage is the same (±2%). But the additional VAR should be multiplied by the CT ratio. For example, ±3.0VAR becomes ±3.0VAR * CT ratio ±4.0VAR becomes ±4.0VAR * CT ratio Range of CT (Current Transformer) Ratio : 1 to 250 H.P. (Horse Power) 1 H.P. = 746 W AC Active Energy ( WH, or KWH, from 0 WH to 999,999 AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor < 4, CT=1) (Overload Protection AC 2000A) of Readings 4 10.0-1500.0 A 0.01 A ± 2% ± 5dgts 4 For CT = 1, the accuracy in percentage is the same (±2%). But the additional digits should be multiplied by the CT ratio. For example, ±5 digits becomes ±5 digits * CT ratio AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor < 4, Input Impedance 10 MV, Overload Protection AC 800V) of Readings 10.0 V - 600.0 V 0.1 V ± 0.5% ± 5dgts Harmonics of AC Voltage in Percentage (1 to 99 order, minimum voltage at the 50 or 60 Hz > AC 80V. If the voltage is 0 at 50 or 60 Hz, all the percentage (%) display is 0.) 1-20 th 0.1% ±2% 21-49 th 0.1% 4%of reading ± 2.0% 50-99 th 0.1% 6%of reading ± 2.0% Harmonics of AC Voltage in Magnitude (1 to 99 th order, minimum voltage at the 50 or 60 Hz > AC 80V) 1-20 th 0.1% ± 2.0% ± 0.5V 21-49 th 0.1% 4%of reading ± 0.5V 50-99 th 0.1% 6%of reading ± 0.5V KWH) WH = W * Time (in hours) 28 29 Harmonics of AC Current in Percentage (1 to 99 th order, minimum current at the 50 or 60 Hz o 20 A. If the current is 0 at 50 or 60 Hz, all the percentage (%) display is 0.) 1-20 th 0.1% ±2% 21-49 th 0.1% 4% of reading ± 2.0% 50-99 th 0.1% 6% of reading ± 2.0% Harmonics of AC Current in Magnitude (1 to 99 th order, minimum current at the 50 or 60 Hz > 20A) 1-20 th 0.1% ± 2% of reading ± 0.4A 21-49 th 0.1% ± 4% of reading ± 0.4A 50-99 th 0.1% ± 6% of reading ± 0.4A Power Factor (PF) >20V & >20A <20V or <20A 0.000-1.000 0.001 ± 0.04 ± 0.1 Phase Angle (u) -180 to 180 0 0.1 0 ±1 0 0 to 360 0 0.1 0 ±1 0 Total Harmonic Distortion (THD-F with respect to the 50 or 60 Hz, min. value at the 50 or 60 Hz > 80V and > 20 A, 1 to 50 Harmonics. If the voltage or current is 0 at 50 or 60 Hz, all the percentage (%) dispiay is 0) 0.0-20% 0.1% ±2.0% 20-100% 0.1% ± 6% of reading ±1% 100-999.9% 0.1% ±10% of reading ±1% Peak Value of AC Voltage (peak value > 5V) or AC Current (peak value > 20A) Range Sampling Time Accuracy of Reading 50 Hz 39 ms ± 5% ± 30 digits 60 Hz 33 ms ± 5% ± 30 digits Crest Factor (C.F.) of ACV (peak value > 5V) or ACA (peak value > 20A) of Reading 1.00-99.99 0.01 ± 5% ± 30 digits Resistance (V) and Continuity (Beep if less than 50V) 7.0-999.9 V 0.1 V ± 5 V 1000-1200 V 1 V ± 5 V If reading is less than 7V, it is displayed as 0V Frequency (RMS Value >10V) or ACA (RMS value >30A) of Readings 45-65 0.1 ± 0.2 Hz 30 31

Indoors Use Conductor Size : 55mm (approx.), 64 x 24mm (bus bar) : two 1.5V SUM-3 : 4+4 digits LCD : Auto : OL : 10mA (approx.) Battery Type Display Range Selection Overload lndication Power Consumption Low battery Indication : Auto-Power-Off : 30 minutes after power-on Update Time : 2 times/sec. (display) No. Of Samples per Period : 512 (voltage or current) 256 (power) Operating Temperature : -10 0 C to 50 0 C Operating Humidity : less than 85% relative Altitude : up to 2000M Storage Temperature : -20 0 C to 60 0 C Storage Humidity : less than 75% relative Dimension : 210 x 62 x 35.6mm (approx.) Weight : 640gms including battery (approx.) Accessories : Test leads x 1 Carrying bag x 1 Instruction manual x 1 Batteries 1.5V x 2 (installed) Option : Alligator clips 7. BATTERY REPLACEMENT When the low battery symbol is displayed on the LCD, replace the old batteries with two new batteries. A. Turn the power off and remove the test leads from the clamp meter. B. Remove the screw of the back C. Lift and remove the back D. Remove the old batteries. E. Insert two new 1.5V SUM-3 batteries. F. Place the back cover and secure the screw. 32 33 8. MAINTENANCE & CLEANING Servicing not covered in this manual should only be performed by qualified personnel. Repairs should only be performed by qualified personnel. Periodically wipe the case with a damp doth and detergent; do not use abrasives or solvents. N O T E 34