Operating and indicating elements. 4 x LED green Lighting LED = power and

Similar documents
Operating instructions Flow monitor. SAxxx / / 2015

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx / / 2004

Technical data. General specifications. Indicators/operating means

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Assembly. Front view. LEDs. Parametrization interface. Power Bus

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Luminaire installation box Surface-mounted box Ceiling installation box

Amplifier for fiber optics. Dimensioned drawing

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Operating instructions Capacitive level sensor KNQ

Electrical connection

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

SU17 Series Fiber Optic Sensors

Electrical connection

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Amplifier for fiber optics. Dimensioned drawing

Photoelectrics Through-beam Type PA18C.T..., DC

Gamma instabus. Technical product information

Model IQ4-PC User Manual Revision Date:

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

KNX Dimmer RGBW - User Manual

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

WELDING CONTROL UNIT: TE 450 USER MANUAL

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Absolute Encoders Multiturn

Operating instructions Electronic preset counter Type series 717

Single Axis Position Controller

Operating Instructions

HS-509 VIBRATION TRIP MODULE

Dimming actuators GDA-4K KNX GDA-8K KNX

Laser Loop E Z Setup. Blake Bourque. Contents. Coil Control

02/11/2015

REGO Start&Go USER MANUAL

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

W100L: Laser Sensor in Mini- Format

MOONRING MULTIPLES INSTALLATION INSTRUCTIONS MOONRING MULTISTAK TM STACKED CANOPY. A nd Avenue, Unit 1 Oakland,

Electrical connection

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Standard signal metering in wall-mounting case

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

DCS-2800LH and DCS-H100. User s Manual

INSTALLATION & USER GUIDE

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Revision 1.2d

Motion detector theluxa P300 KNX Motion detector theluxa P300 KNX

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Programming Manual for ETA25PM and MABxxAPM series

Radio Thermostat Clock

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

of Loewe E 2.10_m1 1

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Dohse Aquaristik GmbH & Co. KG

User Manual. SafeShield Safety Light Curtain Hardware

Electrical connection

Safety Light Curtain C 4000 Basic/Micro

Automatic Transfer Switch Control PLC Operator s Manual

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Optical Technologies Micro Motion Absolute, Technology Overview & Programming

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

PicoSpot 20 LED moving head. user manual

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Filter Control FS-201

Analogue Inputs Resolution Assignment

Electronic Pulse Counter Combination device

Flow Sensor SFAB. 1.2 Characteristics Feature Order code Design. Festo AG & Co. KG. Postfach D Esslingen ++49/711/

GreenParking. Commissioning guide. GreenParking

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Instruction manual. DALI Gateway art Installation manual

KNX Technical Reference Manual Busch-EnergyControl

Position transmitter SDAT-MHS f [ ]

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Transponder Reader TR22A01KNX TR22A11KNX. Product Handbook

Wall-/Pipe-Mount Level Indicator

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

MICROMASTER Encoder Module

1440/2880 HP RGB+WW+CW

Smart-Encoder : Optical Incremental

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Selection matrix for electronic pressure switches

Multifunction devices

Process transmitter RMA422

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

PQ-Box 100 Quick Start Instructions

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Transcription:

Functions and features The optical distance sensor measures distances of 0.2...10 m indicates the measured value on the 10-segment display generates 2 output signals according to the set output function Operating and indicating elements POWER mm m inch OUT1 OUT2 1 2 3 5 4 ODE ENTER ET 1 2 3 4 5 4 x LED green Lighting LED = power and 4 x LED yellow (two not used) 4-digit alphanumeric display Programming button et Programming button ode / Enter set display unit (mm, m, inch) Indication of the switching status, lights if the corresponding output is switched. Indication of the measured distance, the parameters and parameter values. etting of the parameter values (scroll by holding down, increment by pressing briefly). election of the parameters and acknowledgement of the parameter values ENGLIH 17

witching functions The outputs 1 and 2 can be set separately as normally open / normally closed, output 2 can also be configured as 4 20 ma analogue output. Analogue output (only output 2) Output 1 Output 2 I: 4... 20mA witching function (output 1 and output 2; function can be set separately per output) witching logic (applies to both switching outputs) normally open (Hno) normally closed (Hnc) p-switching (PnP) Electrical connection The unit must only be connected by a skilled electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN50178, ELV, PELV. Disconnect power before connecting the unit. 2: OUT2 4: OUT1 2 x p-switching 1 2 4 3 BN WH BK BU L+ L 1 x p-switching / 1 x analogue 2: OUT2 4: OUT1 1 2 4 3 BN WH BK BU L+ L Core colours of ifm sockets: 1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black). 18

Operating modes Run mode Normal operating mode After power on the unit is in the Run mode. It carries out its monitoring function and generates output signals according to the set parameters. The display indicates the current distance, the yellow LEDs signal the switching status of the outputs. Display mode Indication of the parameters and the set parameter values After a short press of the "ode/enter" button the unit goes to the Display mode. Internally it remains in the operating mode. Irrespective of this the set parameter values can be read: Press the "ode/enter" button briefly to scroll the parameters. Press the "et" button briefly to indicate the corresponding parameter value for 15 s. After another 15 s the unit returns to the Run mode. Programming mode etting of the parameter values The unit goes to the programming mode when a parameter has been selected and the "et" button is then pressed for over 5 s (the indicated parameter value flashes and is then incremented continuously). Internally the unit remains in the operating mode. It continues its monitoring function with the existing parameters until the change has been terminated. You can change the parameter value by pressing the "et" button and confirm it by pressing the "ode/enter" button. The unit returns to the Run mode if no button is pressed for over 15 s. ENGLIH 19

Programming The sensor is programmed using the two buttons "ode/enter" and "et". First call a parameter with the "ode/enter" button, select the requested value with the "et" button and confirm it pressing again the "ode/enter" button. 1 ODE ENTER ET Press the ode/enter button until the requested parameter is displayed. 2 ODE ENTER ET Press the et button and keep it pressed. The indicated current parameter value flashes for 5 s, then it is increased* (incremental by pressing briefly or scrolling by holding pressed). 3 ODE ENTER ET Press the ode/enter button briefly (= acknowledgement). The parameter is displayed again, the new parameter value becomes effective. 4 Change more parameters: tart again with step 1. Finish programming: Wait for 15 s or press the ode/ Enter button until the current measured value is displayed again. * Decrease the value: Let the display move to the maximum setting value. Then the cycle starts again at the minimum setting value. 20

elect the display unit (UniT) before you define the values for the parameters P1, P2, AP, AEP. This avoids rounding errors during internal conversion to other units and enables exact setting of the values. When delivered: mm. If no button is pressed for 15 s during the setting procedure, the unit returns to the Run mode with unchanged values. The unit can be electronically locked to prevent unwanted adjustment of the set parameters: Press the two programming buttons in the Run mode until is displayed. For unlocking press the buttons until is displayed. On delivery: Unlocked. When the unit is locked, is briefly displayed when you try to change parameter values. et-up / Operation After mounting, wiring and programming check whether the unit operates correctly. Align the unit (laser beam) to the object to be detected. If correctly set up, the distance to the object is indicated. Faults displayed during operation: ++ too much light, e.g. reflective surfaces -- not enough light far measured object outside the measuring range > 10m near measured object outside the measuring range < 0.2m C1 short circuit in switching output 1 C2 short circuit in switching output 2 C short circuit in both switching outputs ENGLIH Life of the laser diode: 50000 hours. 21

Technical information / Operation / Parameters Adjustable parameters witch point 1 / 2 Limit values at which the outputs change their switching status. P2 is only active if OU2 = Hno or Hnc. Configuration for output 1 2 switching functions are adjustable: - Hno = hysteresis function / normally open - Hnc = hysteresis function / normally closed Configuration for output 2 2 switching functions and 1 analogue signal can be set: - Hno = hysteresis function / normally open - Hnc = hysteresis function / normally closed - I = analogue output 4... 20mA Analogue start point easured value at which 4 ma is provided. AP is only active if OU2 = I. Analogue end point easured value at which 20 ma is provided. inimum distance between AP and AEP = 100 mm. AEP is only active if OU2 = I. The error message "IZE" is displayed if you try to enter a distance which is below the minimum distance. Teach election "sampling rate" or "repeatability" etting ranges: ampling rate 1...50 Hz Accuracy 1...100 mm The sampling rate influences the accuracy and vice versa. High sampling rate low accuracy. High accuracy low sampling rate. Extended functions This menu point includes a submenu with more parameters. Press the et button briefly to access these parameters which will be explained on the following pages. 22

Delay for the switching outputs dx = switch-on delay; drx = switch-off delay. The output does not immediately change its switching status when the switching condition is met but only after the delay has elapsed. If the switching condition is no longer met after the delay has elapsed, the switching status of the output does not change. etting range: 0 / 0.1... 5 s in steps of 0.1 s (0 = delay is not active); Indication in seconds d2 and dr2 are not effective if OU2 = I. Display setting 7 settings can be selected: d1 = update of the measured value every 50 ms d2 = update of the measured value every 200 ms d3 = update of the measured value every 600 ms The update of the measured value only refers to the display. It has no effect on the outputs. rd1, rd2, rd3 = display like d1, d2, d3, but rotated by 180. OFF = The measured value display is deactivated in the Run mode. Press one of the buttons to indicate the current measured value for 15 s. If the ode/enter button is pressed once again, the display mode is activated. The LEDs remain active even if the display is deactivated. Indication of the signal strength in % Check the sensor alignment, if necessary. ENGLIH 23

Display unit easured value and values for P1, P2, AP, AEP can be indicated in the following units: mm, m, inch elect the display unit before you define the values for the parameters P1, P2, AP, AEP. This avoids rounding errors during internal conversion to other units and enables exact setting of the values. When delivered: mm, the selected unit is indicated by a green LED on the display. Restore basic settings (factory settings) - Press the "ode/enter" button until re is displayed. - Press the "et" button and keep it pressed until - - - - is displayed. - Press the "ode/enter" button briefly ( the unit passes into the Run mode). The unit is delivered with the following factory settings: Unit of mesurement mm p1: 1000 mm p2: 2000 mm OU1: Hno (normally open) OU2: Hno (normally open) AP: 0 mm AEP: 9999 mm ampling rate: 50 Hz Delay: 0 s Display update d3 (600 ms) Display of the software version number 24

Hysteresis function: The hysteresis is calculated from the repeatability (see table below) with a safety factor 1.5. Example: ampling rate 50 Hz, distance to the object 1200 mm, grey value (18 % remission): Repeatability according to the table 20 mm x factor 1.5 = 30 mm Reset point 1200 mm + (30 mm / 2) = 1215 mm et point 1200 mm - (30 mm / 2) = 1185 mm The reset point is always greater than the set point. For sensing ranges up to 6000 mm the hysteresis is calculated for a 18 % remission, for sensing ranges over 6000 mm for a 90 % remission. Table for sampling rate 50 Hz: Distance [mm] white 90% remission Repeatability grey 18% remission Range on black (6 % remission) 4000 mm white 90% remission Accuracy grey 18% remission 200...1000 10 mm 15 mm ± 15 mm ± 18 mm 1000...2000 11 mm 20 mm ± 15 mm ± 20 mm 2000...4000 35 mm 45 mm ± 25 mm ± 32 mm 4000...6000 55 mm 80 mm ± 35 mm ± 50 mm 6000...10000 120 mm ± 70 mm The values apply at - constant ambient conditions (23 C / 960 hpa) - extraneous light of max. 8 klx - only after unit powered up for 10 minutes. ENGLIH 25

caling of the measuring range (analogue output) With the parameter analogue start point (AP) you define at which measured value the output signal is 4 ma. With the parameter analogue end point (AEP) you define at which measured value the output signal is 20 ma. The analogue end point (AEP) can be selected so that it is located before the analogue start point (AP). This implements a falling edge. Current output 4... 20 ma Factory setting I [ma] 20 I [ma] 20 easuring range scaled 4 4 0(AP) 10000(AEP) mm 0 AP AEP EW mm EW = final value of the measuring range In the set measuring range the output signal is between 4 and 20 ma. It is also signalled: Distance value outside the analogue start point (AP): 3.5 ma Distance value outside the analogue end point (AEP): 20.5 ma 26

Overview main menu (for programming see page 6) = ode/enter = et Distance display 4261 witch point 1 Configuration for switch point 1 P1 1000 200...9999 mm OU1 Hno Hno Hnc Enter value elect Hno or Hnc Configuration for switch point 2 OU2 Hno Hno Hnc I elect Hno or Hnc or analogue current output witch point 2 P2 2000 200...9999 mm Enter value if output 2 = Hno oder Hnc Analogue start point Analogue end point AP 0 AEP 9999 0...9999 mm 0...9999 mm Enter values if output 2 = I ENGLIH Teach mode Extended functionss TEAC EF rate 50 repr 23 ee submenu Teach ee submenu extended functions 27

Overview submenu "extended functions" Extended functions EF witch-on delay switching output 1 wich-off delay switching output 1 witch-on delay switching output 2 wich-off delay switching output 2 etting display d 1 0 0...0,1...5s dr 1 0 0...0,1...5s d 2 0 0...0,1...5s dr 2 0 0...0,1...5s di d3 d 1 d 2 d 3 r d 1 r d 2 r d 3 OFF Update: - every 50 ms - every 200 ms - every 600 ms Display rotated by 180, update: - every 50 ms - every 200 ms - every 600 ms Display deactivated Indication of the signal strength in % election unit of measurement ALIG + 096 Uni mm mm m inch Restore basic settings Display of the software version number 28 re re ---- W r20c

Overview submenu 'Teach' accuracy / sampling rate Teach TEAC Alternating display rate / accuracy WAIT 50 1...50 Hz rate 50 repr 2.3 WAIT 2.3 1...100 mm * * Repeatabilities are selectable that can be achieved in the current situation (depending on the object) The repeatability must be calculated internally before the alternating display. If this calculation has not yet been completed, WAIT appears. etting of the sampling rate (influences the accuracy) etting of the accuracy (influences the sampling rate) cale drawing ENGLIH 1: Programming button ET 2: Programming button ODE / Enter 3: 4-digit alphanumeric display LED function display 29

Remarques sur la sécurité Avant la mise en service de l'appareil, veuillez lire la description du produit. Assurez-vous que le produit est approprié pour l'application concernée sans aucune restriction d'utilisation. Le non-respect des remarques ou des données techniques peut provoquer des dommages matériels et/ou corporels. Lumière laser visible; classe de protection laser 2. Ne pas regarder le faisceau laser! Les étiquettes jointes (avertissement laser) doivent être affichées à proximité immédiate de l'appareil. Veuillez prendre en compte les avertissements sur l'étiquette du produit. Contenu Remarques sur la sécurité................................... 30 Caractéristiques et fonctionnement............................ 31 Eléments de service et d'indication............................. 31 Raccordement électrique.................................... 32 odes de fonctionnement................................... 33 Programmation........................................... 34 ise en service / Fonctionnement.............................. 35 Informations techniques / fonctionnement / paramètres Paramètres réglables.................................... 36 Tableau taux de mesure / précision / répétabilité................ 39 enu principal........................................ 41 ous menu fonctions étendues............................ 42 ous menu Teach...................................... 43 chéma d'encombrement................................ 43 30